HomeMy WebLinkAboutCF Fire Pump Report CSA 183 12_2019 Durham . Pump PUMP CHECK REPORT
2313 Durham-Dayton Hwy.
Durham, CA 95938 530.891.4821 CSA#183 - Rare Earth Subdivision
CUSTOMER NAME: Butte County Fire Dept. DATE: 12/13/2019
Motor Mfg: Franklin HP: 1.5 Meter#:
RPM 3450 Volts 240 Phase 1 Rated Amps: 11.5 MAX
TM 80 Yes No Serial#
PG &E Acct. # Other:
Panel Mfg: NEMA Size:
Type: X X/L P/W Other:
Pump Mfg: ?Sub Serial#:
Non-Running Checks: Pump Model Manufacturer
na Lubricant Levels-Service and Change if Necessary Discharge CAST 11/4
na Oiler Unit and/or Packing
Electrical Leads & Connections - Repair and Tighten as Necessary
Incoming Idle Voltage: W/I Acceptable Limits Unacceptable
Fuses - Replace if Necessary Replaced Size: 20 AMP BREAKER
Perform General Clean-Up of Electrical Panel and Motor
Running Checks: Motor winding resistance: O s to ground
Excessive or Unusual Noise Ok/see comments Pressure tank: PC-266 TANK
Excessive or Unusual Vibration Ok/see comments Tank condition:
(Control Devices: H.O.A. Start Switch Time Clock
Frost Start nTime Delay Other: PRESS. SWITCH
Amperage: Expected: 11.5 Pressure setting: 40-60
Actual: Y 11.8 B 12.7 R 1.5 Average: 8.667
Overload Underload Even Load
Bowl Adiustment: N/A Yes No
Comments:
Gate broken
GPS:
The above readings reflect the site and pump conditions at the time of inspection.
This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system.
S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\183 Rare Earth Subd\183 Reports
Durham iik Pump PUMP CHECK REPORT
2313 Durham-Dayton Hwy.
Durham, CA 95938 530.891.4821 CSA#183 - Rare Earth Subdivision
CUSTOMER NAME: Butte County Fire Dept. DATE: 12/13/2019
Motor Mfg: Franklin HP: 60 Meter#: 1005378640
RPM ? Volts 480 Phase 3 Rated Amps: ?
TM 80 Yes No Serial#
PG &E Acct. # Other:
Panel Mfg: SIEMANS NEMA Size: 3.5
Type: X X/L P/W Other:
Pump Mfg: ? Sub Serial#:
Non-Running Checks: Pump Model Manufacturer
na Lubricant Levels -Service and Change if Necessary Discharge 6" Fab
na Oiler Unit and/or Packing
Electrical Leads & Connections - Repair and Tighten as Necessary
Incoming Idle Voltage: nW/I Acceptable Limits Unacceptable
Fuses - Replace if Necessary Replaced Size: FLSR 200 ID
Perform General Clean-Up of Electrical Panel and Motor
Running Checks: Motor winding resistance: O's to ground
Excessive or Unusual Noise Ok/see comments Pressure tank:
Excessive or Unusual Vibration Ok/see comments Tank condition:
Control Devices: H.O.A. Start Switch Time Clock
1-7 Frost Start (Time Delay Other:
Amperage: Expected: 80.5 Pressure setting: Press Sw 50-70
Actual: L1 66.4 L2 65 L3 64.2 Average: 65.2
Overload Underload Even Load
Bowl Adiustment: N/A Yes No
Comments:
Slightly high incoming voltage. 491V,492V, 490V
GPS:
The above readings reflect the site and pump conditions at the time of inspection.
This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system.
S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\183 Rare Earth Subd\183 Reports