Loading...
HomeMy WebLinkAboutCF Fire Pump Report CSA 178 12_2019 Durham ib Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#178 -Twin Palms CUSTOMER NAME: Butte County Fire Dept. DATE: 12/13/2019 Motor Mfg: Franklin HP: 1/2 Meter#: RPM 3450 Volts 240 Phase 1 Rated Amps: 6 TM 80 Yes No Serial# PG &E Acct. # Other: Panel Mfg: Franklin 1/2 HP Control Box NEMA Size: Type:nX/L n P/W Other: Pump Mfg: Serial#: Non-Running Checks: Pump Model Type Submersible na Lubricant Levels - Service and Change if Necessary na Oiler Unit and/or Packing Electrical Leads & Connections- Repair and Tighten as Necessary Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses- Replace if Necessary Replaced Size: FRN-R-8 Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: O's to ground Excessive or Unusual Noise Ok/see comments Pressure tank: AP-80 Excessive or Unusual Vibration Ok/see comments Tank condition: ok Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: PRESS. SWITCH Amperage: Expected: 6 Pressure setting: 50-70 psi Actual: R 0.08 Y 5.6 B 5.6 Average: 3.76 Overload Underload Even Load Bowl Adjustment: N/A Yes No Comments: GPS: 39°42' 21.81"N 121° 47'43.33"W The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS& INSPECTIONS\Cal Fire CSA's\178 Twin Palms\178 Reports Durham '. Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#178 -Twin Palms CUSTOMER NAME: Butte County Fire Dept. DATE: 12/13/2019 Motor Mfg: Franklin HP: 25 Meter#: 1006782494 RPM 3450 Volts 240 Phase 3 Rated Amps: 64 TM 80 Yes No Serial# PG &E Acct. # Other: Panel Mfg: Square D NEMA Size: 3 Type: X X/L P/W Other: Pump Mfg: Serial#: Non-Running Checks: Pump Model Manufacturer Lubricant Levels - Service and Change if Necessary Discharge na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses - Replace if Necessary Replaced Size: FLNR-100-10 Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: O's to ground Excessive or Unusual Noise Ok/see comments Pressure tank: Excessive or Unusual Vibration Ok/see comments Tank condition: Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Amperage: Expected: 64 Pressure setting: PRESS SWITCH Actual: L1 62 L2 58 L3 53.7 Average: 57.9 Overload Underload Even Load Bowl Adiustment: N/A Yes No Comments: GPS: 39°42' 21.81"N 121° 47' 43.33"W The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\178 Twin Palms\178 Reports