Loading...
HomeMy WebLinkAboutCF Fire Pump Report CSA 158 12_2019 Durham : Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#158 Ishi Valley CUSTOMER NAME: Butte County Fire Dept. DATE: 12/12/19 Motor Mfg: Franklin HP: 25 Meter#: 1006908237 RPM 3450 Volts 240 Phase 3 Rated Amps: 75 TM 80 Yes No Serial# PG &E Acct. # Other: Panel Mfg: Furnas NEMA Size: 3 Type: X/L P/W Other: Discharge Mfg: Steel 6" Serial#: Non-Running Checks: Pump Model Manufacturer na Lubricant Levels -Service and Change if Necessary na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses- Replace if Necessary Replaced Size: TR9OR Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: Excessive or Unusual Noise Ok Excessive or Unusual Vibration Ok Control Devices: X H.O.A. X Start Switch (Time Clock Frost Start Time Delay Other: Pressure Switch Amperage: Expected: 65 Actual: L1: 68 L2: 75.1 L3: 61.2 Average: 68.1 Overload Underload Even Load Bowl Adjustment: N/A Yes No Comments: Slightly overloaded with uneven load but within service factor Gate is falling apart, needs to be repaired or replaced. GPS: 39°48'32.57"N 121°53'38.30"W The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\158 Ishi Valley\158 Reports Durham; '. Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#158 Ishi Valley CUSTOMER NAME: Butte County Fire Dept. DATE: 12/12/19 Motor Mfg: Franklin HP: 1 Meter#: 1006908237 RPM 3450 Volts 240 Phase 1 Rated Amps: 9.8 TM 80 Yes No Serial# PG &E Acct. # Other: Panel Mfg: Franklin control box NEMA Size: Type: X/L P/W Date code Discharge Mfg: 1 1/4 Serial#: Non-Running Checks: Tank Model WX-302 Manufacturer Well-X-Trol na Lubricant Levels - Service and Change if Necessary na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses- Replace if Necessary Replaced Size: N/A Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: Less than 1 Meg O's to ground Excessive or Unusual Noise Ok Excessive or Unusual Vibration Ok Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Pres. Sw. 30-50 Amperage: Expected: Actual: Red: 0.8 Yellow: 11.6 Black: 10.3 Average: 7.567 Overload Underload Even Load Bowl Adiustment: N/A Yes No Comments: GPS: 39°48'32.57"N 121°53'38.30"W The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS& INSPECTIONS\Cal Fire CSA's\158 Ishi Valley\158 Reports