HomeMy WebLinkAboutCSA 128 CF Fire Well and Pump Testing 2019 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax www.powerhydrodynamics.com Monday, August 5, 2019 Dave Woods Hereford Sub Division 20 Red Fox Ct. Chico, CA 95973 Dear Dave Woods: Enclosed are the results of your pump test. The results are based on conditions during the time of the test. If these conditions vary from the normal operation of your pump, the results shown may not describe the pump's normal performance. Some of the factors, which influence pump performance, are: - Changes in discharge pressures - Changes in water table level and well yield - Pump wear - Proper pump design for application We offer the following services to help our customers save time and money. Pump testing, irrigation system analysis, irrigation water management, and electric rate management. Visit our website at www.powerhydrodynamics.com for more information or to use our water cost calculator. Please feel free to call 209-527-2908 if you have questions about this test or on the other services that Power Services has to offer. Regards, William Thomas Power, Ill Enclosures 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax www.powerhydrodynamics.com CONFIDENTIAL/PROPRIETARY INFORMATION Dave Woods Monday, August 5, 2019 Hereford Sub Division 20 Red Fox Ct. Chico, CA 95973 SUBJECT: PUMPING COST ANALYSIS HP: 20.00 Plant: Hereford Fire Pump PUMP TEST REFERENCE NUMBER: PT-23095 PUMP TEST RUN: Run 1 Nearest Hydrant The following Pumping Cost Analysis is presented as an aid to your cost accounting. This analysis is an estimate prepared from operating criteria supplied from the pump test performed Jul 31st 2019 and information provided by you during the pump test. It is recommended and assumed that: 1. Overall plant efficiency can be improved to: 60% 2. Water requirements will be the same as for the past year. 3. All operating conditions (annual hours of operation, discharge head, and water pumping level)will remain the same as they were at the time of the pump test. EXISTING PLANT IMPROVED PLANT SAVINGS EFFICIENCY EFFICIENCY kWh/AF 263.7 216.9 46.8 Estimated Total kWh 23,791 19,570 4,221 Average Cost per kWh $0.24 $0.24 Average Cost per hour $5.66 $4.76 $0.9 Cost Per Acre Ft. $62.72 $51.59 $11.13 Estimated Acre Ft. Per Year 90.23 90.23 Run Hours 1,000.00 1,000.00 Overall Plant Efficiency 49.4% 60% Estimated Total Annual Cost $5,658.85 $4,654.89 $1,003.96 It is sincerely hoped that this information will prove helpful to you, and that your concerns over maintaining optimum pumping efficiency will be continued. If you have any questions, please contact Bill Power at(209) 527-2908. Regards, William Thomas Power, III Enclosures 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax Report ID: PT-23095 www.powerhydrodynamics.com Agricultural and Domestic Pump Test Report Hereford Sub Division - Hereford Fire Pump - Run 1 Nearest Hydrant Latitude: 39.81323W Longitude: -121.90109N Elevation: 190 ft Test Date: Jul 31st 2019 Tester: Bill Power Nameplate HP: 20.00 hp Customer Information Power Company Data Equipment Data Hereford Sub Division PG&E Motor Make: Franklin 20 Red Fox Ct. Meter#: 1006873268 Volts/Amps: 460V/26.9A Chico, CA 95973 Rate Schedule: Al Serial#: Average Cost: $0.24 Pump Make: No Name Plate Contact: Dave Woods Pump Type: Submersible Cell: 530-230-7825 Drive Type: Electric Motor Gearhead Make: Hydraulic Data Flow Data Standing Water Level (SWL): 51.50 ft Run Number: 1 of 2 Recovered Water Level (RWL): 52.00 ft Measured Flow: 490 gpm Pumping Water Level (PWL): 81.00 ft Customer Flow: 0 gpm Drawdown: 29.5 ft Flow Velocity: 4.52 ft/sec Discharge Pressure: 20.00 lb/sqft Acre Feet per 24 Hr: 2.17 Discharge Level: 46.2 ft Cubic Feet Per Second (CFS): 1.09 ft Total Lift: 127.2 ft Discharge Pressure: 20 psi Well Yield: 16.61 gpm/ft Water Source: Well Power Data Horsepower Input to Motor: 31.89 hp Percent of Rated Motor Load: 131% Brake Horsepower: 26.15 hp Kilowatt Hours per Acre Foot: 263.68 Kilowatt Input to Motor: 23.79 kW Cost to Pump an Acre Foot: $62.72 Energy Cost: $5.66/hr Overall Plant Efficiency: 49.36% Name Plate RPM: 3450 rpm Water Horsepower: 15.74 hp Run Hours: 1000 Remarks All results are based on conditions during the time of the test. If these conditions vary from the normal operation of your pump,the results shown may not describe the pump's normal performance. Motor loading may be excessive. Suggest contacting your pump serviceman. Overall efficiency of this plant is considered to be fair assuming this run represents plant's normal operating condition. Recovered water level based on 5 minutes recovery,well could still be recovering. Pump started for test, pumping water level could still be drawing down. This pump has an adequate test section. This pump did not have a flow meter. HPI measured with direct read KWI. Cost Analysis page is based on 1000 run time hours.Your savings may differ based on pumps actual usage. 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax www.powerhydrodynamics.com CONFIDENTIAL/PROPRIETARY INFORMATION Dave Woods Monday, August 5, 2019 Hereford Sub Division 20 Red Fox Ct. Chico, CA 95973 SUBJECT: PUMPING COST ANALYSIS HP: 20.00 Plant: Hereford Fire Pump PUMP TEST REFERENCE NUMBER: PT-23095 PUMP TEST RUN: Run 2 Farthest Hydrant The following Pumping Cost Analysis is presented as an aid to your cost accounting. This analysis is an estimate prepared from operating criteria supplied from the pump test performed Jul 31st 2019 and information provided by you during the pump test. It is recommended and assumed that: 1. Overall plant efficiency can be improved to: 60% 2. Water requirements will be the same as for the past year. 3. All operating conditions (annual hours of operation, discharge head, and water pumping level)will remain the same as they were at the time of the pump test. EXISTING PLANT IMPROVED PLANT SAVINGS EFFICIENCY EFFICIENCY kWh/AF 298.2 228.4 69.9 Estimated Total kWh 22,901 17,537 5,364 Average Cost per kWh $0.24 $0.24 Average Cost per hour $5.45 $4.76 $0.69 Cost Per Acre Ft. $70.94 $54.33 $16.62 Estimated Acre Ft. Per Year 76.78 76.78 Run Hours 1,000.00 1,000.00 Overall Plant Efficiency 45.9% 60% Estimated Total Annual Cost $5,447.14 $4,171.31 $1,275.84 It is sincerely hoped that this information will prove helpful to you, and that your concerns over maintaining optimum pumping efficiency will be continued. If you have any questions, please contact Bill Power at(209) 527-2908. Regards, William Thomas Power, III Enclosures 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax Report ID: PT-23095 www.powerhydrodynamics.com Agricultural and Domestic Pump Test Report Hereford Sub Division - Hereford Fire Pump - Run 2 Farthest Hydrant Latitude: 39.81323W Longitude: -121.90109N Elevation: 190 ft Test Date: Jul 31st 2019 Tester: Bill Power Nameplate HP: 20.00 hp Customer Information Power Company Data Equipment Data Hereford Sub Division PG&E Motor Make: Franklin 20 Red Fox Ct. Meter#: 1006873268 Volts/Amps: 460V/26.9A Chico, CA 95973 Rate Schedule: Al Serial#: Average Cost: $0.24 Pump Make: No Name Plate Contact: Dave Woods Pump Type: Submersible Cell: 530-230-7825 Drive Type: Electric Motor Gearhead Make: Hydraulic Data Flow Data Standing Water Level (SWL): 51.50 ft Run Number: 2 of 2 Recovered Water Level (RWL): 52.00 ft Measured Flow: 417 gpm Pumping Water Level (PWL): 78.50 ft Customer Flow: 0 gpm Drawdown: 27 ft Flow Velocity: 3.85 ft/sec Discharge Pressure: 24.00 lb/sqft Acre Feet per 24 Hr: 1.85 Discharge Level: 55.44 ft Cubic Feet Per Second (CFS): 0.93 ft Total Lift: 133.94 ft Discharge Pressure: 24 psi Well Yield: 15.44 gpm/ft Water Source: Well Power Data Horsepower Input to Motor: 30.7 hp Percent of Rated Motor Load: 126% Brake Horsepower: 25.17 hp Kilowatt Hours per Acre Foot: 298.25 Kilowatt Input to Motor: 22.9 kW Cost to Pump an Acre Foot: $70.94 Energy Cost: $5.45/hr Overall Plant Efficiency: 45.95% Name Plate RPM: 3450 rpm Water Horsepower: 14.1 hp Run Hours: 1000 Remarks All results are based on conditions during the time of the test. If these conditions vary from the normal operation of your pump,the results shown may not describe the pump's normal performance. Motor loading may be excessive. Suggest contacting your pump serviceman. Overall efficiency of this plant is considered to be low assuming this run represents plant's normal operating condition. Recovered water level based on 5 minutes recovery,well could still be recovering. Pump started for test, pumping water level could still be drawing down. This pump has an adequate test section. This pump did not have a flow meter. HPI measured with direct read KWI. Cost Analysis page is based on 1000 run time hours.Your savings may differ based on pumps actual usage. 6301 Bearden Lane Power Services Inc. Modesto, CA 95357 209.527.2908/800.808.9283 209.527.2921 fax www.powerhydrodynamics.com DAVE WOODS HEREFORD SUB DIVISION 20 RED FOX CT. CHICO, CA 95973 Pump Name: HEREFORD FIRE PUMP Pump Location: Latitude: 39.81323W Longitude: -121.90109N Elevation: 190 ft HYDRAULIC TEST RESULTS PT-23095 Test Date: Jul 31st 2019 Tester: Bill Power Utility: PG&E Meter kh: 21.60 Meter#: 1006873268 Rate Sched: Al Meter Const: 1 Annual Run Hrs: 1000 Avg Cost kWh: $0.23786 Equipment Motor Make: Franklin Serial: Volts: 460 Amps: 26.9 Horsepower: 20.00 Gearhead Make: NameplateRPM: 3450 Drive Type: Electric Motor Pump Make: No Name Plate Pump Type: Submersible Water Source: Well Results Test 1 Test 2 Discharge Pressure, PSI 20.00 24.00 Standing Water Level, Feet 51.50 51.50 Drawdown, Feet 29.5 27 Discharge Head, Feet 46.2 55.44 Pumping Water Level, Feet 81.00 78.50 Total Measured Head, Feet 127.2 133.94 Measured GPM 490.00 417.00 Well Yield, GPM/ft Drawdown 16.6 15.4 Acre Feet Pumped in 24 Hours 2.168 1.845 kW Input to Motor 23.79 22.9 HP Input to Motor 31.89 30.697 Motor Load % 130.7 125.9 kWh per Acre Foot 264 298 Overall Plant Efficiency (%) 49.4 45.9 Energy Cost per Hour 5.66 5.45 Water Horsepower, hp 15.74 14.1 Flow Velocity, ft/sec 4.52 3.85 6301 Bearden Lane Power Services, Inc. Modesto, CA 95357 209.527.2908 Fax 209.527.2921 800.808.9283 August 5, 2019 Hereford Sub Division Dave Woods 20 Red Fox Ct. Chico, CA 95973 This letter is to confirm the information we gathered during the Pump Test that was performed on July 31, 2019 for the Fire Hydrants located on Red Fox Ct. in Chico, CA. On this day we measured a sustained flow of 490 GPM at 20 PSI for 60 minutes on the nearest hydrant and a flow of 417 GPM at 24 PSI for 30 minutes on the farthest hydrant. We used equipment that is accurate +/- .02% for flow measurement and +/- .005% for pressure measurement. The methodology used to test this pump was that of the California Association of Pump Test Professionals and is recognized to be accurate by the U.S. Department of Energy, the Hydraulic Institute, the California Energy Commission, Pacific Gas and Electric, Southern California Edison and the California Public Utilities Commission. This information should fulfill the requirements imposed upon you by the inspecting Fire District. Should the Fire Marshall from your District have further questions, please have them contact me directly in my office (209) 527-2908 or (800) 808-9283. Regards, \--.).'iP-- ---EZ,-\_,si. ai----}t-,-- William Thomas Power III Power Services, Inc. for Hereford Sub Division Pra��er Services, Inc_ Flow Tests July 31 , 2019 Test Location Run Measured Red Fox Ct. Chico # GPM Nearest Hydrant 1 490 Farthest Hydrant 2 417 Test conducted by: Bill Power The flow test was performed on 7/31/19