Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ADM20-0110 - Approved
12/14/2020 LANDLORD APPROVAL Coast S[gn, IncorPoraterd Nicole "Nic" Capeci Manager of Proiect Manaclement Phone 7L4'999'L947 Mobile: 7L4-29O-5097 Nicole. Capeci @Coastsig n. com RITE AID Store #06548 Address: 14115 Lakeridg,= Circle Magalia, CA 95954 By my signature below, I hereby represent that I am the owner of the property indicated above or otherwise duly-authorized by the Lease to grant authorization for This Sign Company and/or their su$.-contractor to apply for Permits, remove existing signs and install new signs at the above referenced location. ut-L)t r&ri Ut* Address ^5,i) Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 01.01.20 01.01.20 # by descripion date 0 CL Revised per client A CL Revised per client B CL Revised per client 01.01.20 01.01.20 01.01.20 W:\Rite Aid\Art\_Rite Aid Rebrand 2020\Drawings\-R1.pdfPRJ-RTAD-147434 Reimage Sign Company: Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 09-03-20 # by descripion date 0.0 Teland A. Originator A CL Revised per client B CL Revised per client 08-31-20 1 JU Revised per client 09-03-20 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 SITE OVERVIEW E1: DIRECTIONAL - 4' - 1 1/2" x 3' E2: DIRECTIONAL - 4' - 1 1/2" x 3' E3: DIRECTIONAL - 4' - 1 1/2" x 3' E4: NORTH DTP-> 15' 9 1/8" X 13 3/8" H E5:RITE AID EMBLEM- 3'10" X 5'6 3/8" E6: RITE AID CHANNEL LETTERS-17'1 1/2" X 36 3/4" E7: THRIFTY CHANNEL LETTERS- 1'2" x 3'5 7/8" E8: PHARMACY CHANNEL LETTERS-23 5/8" X 13'8 1/4" E9: GNC LIVE WELL CHANNEL LETTERS- 1' x 10'3 3/8" E10: DRIVE THRU- 10" x 5'8 1/2" E11: RITE AID EMBLEM- 3'10 1/8"X 5'4" E12: RITE AID CHANNEL LETTERS- 17'3 3/4"X 36 1/2" E13: WEST DTP-> 15'9 1/8" X 13 3/8" H E14: DTP CHANNEL LETTERS 13'11"X 13 3/8" H E15: PICK UP WALL PLAQUE E16: CLEARANCE WALL PLAQUE E17: DROP OFF WALL PLAQUE Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 DF DIRECTIONALS E1: DIRECTIONAL - 4' - 1 1/2" x 3' E2: DIRECTIONAL - 4' - 1 1/2" x 3' E3: DIRECTIONAL - 4' - 1 1/2" x 3' PROPOSED SIGNAGE Existing Signages R2: R1: D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured R3:D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured EXISTING E2 E1 E3 E1 E2 E3 Existing Sq Ft: 37.1 Proposed Sq. Ft: 12 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 DF DIRECTIONALS E1: DIRECTIONAL - 4' - 1 1/2" x 3' PROPOSED SIGNAGE Existing Signages R1:D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured Existing Sq Ft: 12.3 Proposed Sq. Ft: 4 R1 PROPOSED 1'-4"3'-0"3'-0"4'-4"3'-0"SIDE A 1'-4"3'-0"3'-0"SIDE B Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 DF DIRECTIONALS E2: DIRECTIONAL - 4' - 1 1/2" x 3' E3: DIRECTIONAL - 4' - 1 1/2" x 3' PROPOSED SIGNAGE Existing Signages R2:D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured R3:D/S Directional Sign with Vinyl 4 Sq.Ft | Box Measured Existing Sq Ft: 24.7 Proposed Sq. Ft: 8 R2/R3 PROPOSED 1'-4"3'-0"3'-0"4'-4"3'-0"SIDE A 1'-4"3'-0"3'-0"SIDE B Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 NORTHEAST ELEVATION E5:RITE AID EMBLEM- 3'10" X 5'6 3/8" R5: NEW RA-LNR-5WH channel letters R11: NEW RA-LNR-5WH channel letters E6: RITE AID CHANNEL LETTERS-17'1 1/2" X 36 3/4" E7: THRIFTY CHANNEL LETTERS- 1'2" x 3'5 7/8" R7: NEW THRFTY-2 face-lit channel letters flush mounted E8: PHARMACY CHANNEL LETTERS-23 5/8" X 13'8 1/4" R8: NEW PHCY-1-BL face-lit channel letters flush mounted E9: GNC LIVE WELL CHANNEL LETTERS- 1' x 10'3 3/8" R9: REMOVE E10: DRIVE THRU- 10" x 5'8 1/2" R10: NEW DT-1 White 11" channel letters E11: RITE AID EMBLEM- 3'10 1/8"X 5'4" E12: RITE AID CHANNEL LETTERS- 17'3 3/4"X 36 1/2" PROPOSED EXISTING EXISTING SIGNAGES PROPOSED SIGNAGES 105.33 Sq.Ft. | Box Measured 105.33 Sq.Ft. | Box Measured 6.95 Sq.Ft. | Box Measured 31.21 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured Existing Sq Ft: 237.6 Proposed Sq. Ft: 255.6 E5 E6 E7 E9 E8 E11 E12 E10 R8 R5 R7 R11 R10 1 2Summit Gray White 1 2 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 NORTHEAST ELEVATION For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLC SLEEVE ANCHOR For use with concrete block. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with concrete. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD & BEARING PLATES For use with wood or EIFS Wall Systems 1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule R5/R11 “Shield” Face: RITE AID BLUE, 3M Trans 3630-157 Sultan Blue RITE AID Green, 3M Trans 3630-5317, White border to illuminate Substrate: Op x 7328LD White(non glare) Returns: 3” Deep, Alumet Medium Grey Trim cap: 1” Thick, Gem Trim 4310 Dove Grey Illumina on: Sloan Prism 5000K LED “RITE” Face: Op x 7328LD White(non glare) Returns: 3” Deep, Alumet Medium Grey Trim cap: 1” Thick, Gem Trim 4310 Dove Grey Illumina on: Sloan Prism 5000K LED “AID” Face: Op x 7328LD White(non glare) Returns: 3” Deep, Alumet Medium Grey Trim cap: 1” Thick, Gem Trim 4310 Dove Grey Illumina on: Sloan Prism 5000K LED RA-LNR-1-WH RA-LNR-2-WH RA-LNR-3-WH RA-LNR-4-WH RA-LNR-5-WH RA-LNR-50-WH 2’-10 ¾” 3’-7” 4’-4 ⅛” 1’-10” 4’-9 ⅜” 3’-3 ½” 13’-4” 16’-6” 20’-0” 8’-5 ¼” 22’-0 ⅛” 15’-2” 2’-4 ⅜” 2’-11 ⅜” 3’-6 ⅝“ 1’-5 ⅞” 3’-10 ⅞” 2’-8 ½” PRODUCT OVERALL HEIGHT A OVERALL WIDTH B SHIELD WIDTH C 5’-7 ⅝” 6’-11 ⅝” 8’-5 ⅜“ 3’-6 ¾” 9’-3 ⅝” 6’-2 ½” 4’-5 ⅛” 5’-5 ⅝ 6’-7 ¾“ 2’-9 ⅝” 7’-3 ¾” 5’-0 ½” “RITE” WIDTH D “AID” WIDTH E 2’-0 ¼” 2’-6” 3’-0 ⅜“ 1’-3 ⅜” 3’-4” 2’-4” 39 Sq.Ft. 60 Sq.Ft. 87 Sq.Ft. 15.44 Sq.Ft. 105.33 Sq.Ft. 49.92 Sq.Ft. CAP HEIGHT F TOTAL SQUARE FOOTAGE ‘ Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 NORTHEAST ELEVATION Face-Lit Channel Letter Set Flush Mounted For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLC SLEEVE ANCHOR For use with concrete block. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with concrete. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD & BEARING PLATES For use with wood or EIFS Wall Systems 1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule R7 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 NORTHEAST ELEVATION For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLC SLEEVE ANCHOR For use with concrete block. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with concrete. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD & BEARING PLATES For use with wood or EIFS Wall Systems 1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule R8 “PHARMACY” Face: 3M Trans 3635-157 Dual-Color Sultan Blue Substrate: .177 Op x 2447 LD Acrylic Returns: 3” Deep, Semi-Gloss White Trim cap: 1” Thick, Semi-Gloss White Illumina on: Sloan Prism 5000K LED “P” (Baseline) = 11”H,14”,18”H, 24”H Face-Lit Channel Letter Set Flush Mounted Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 NORTHEAST ELEVATION For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLCSLEEVE ANCHOR For use with concrete block.Embed a minimum of 2” ¼” DIA. HILTI HIT RODW/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT RODW/HY20 ADHESIVE For use with concrete.Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block or EIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD& BEARING PLATES For use with wood or EIFS Wall Systems1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule Face-Lit Channel Letter Set Flush Mounted R10 Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 EXISTING SIGNAGE Existing Sq Ft: 50.5 DRIVE THRU PHARMACY E4: NORTH DTP-> 15' 9 1/8" X 13 3/8" H E13: WEST DTP-> 15'9 1/8" X 13 3/8" H E14: DTP CHANNEL LETTERS 13'11"X 13 3/8" H E15: PICK UP WALL PLAQUE E16: CLEARANCE WALL PLAQUE E17: DROP OFF WALL PLAQUE EXISTING EXISTING E13E4 PROPOSED PROPOSED R13R4 PROPOSED SIGNAGE NOTE: NEW signs to include all power supplies. Proposed Sq. Ft: 136.1 R4: NEW RA-DT-SF-WS illuminated wall sign flush mounted R13: NEW RA-DT-SF-WS illuminated wall sign flush mounted R14: REMOVE R15: RA-DT-LN-1 R16: RA-DT-CL R17: RA-DT-LN-2 12 Sq.Ft. | Box Measured 12 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLCSLEEVE ANCHOR For use with concrete block.Embed a minimum of 2” ¼” DIA. HILTI HIT RODW/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT RODW/HY20 ADHESIVE For use with concrete.Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block or EIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD& BEARING PLATES For use with wood or EIFS Wall Systems1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule Ancillary Cabinet Face: RITE AID BLUE, 3M Trans 3630-157 Sultan Blue with White copy Substrate: Op x 7328LD White(non glare) Illumina on: Sloan Prism 5000K LED Illuminated Wall Sign Flush Mounted 1'-6"8'-0" R4/R13 Notes: All penetra ons to be sealed with BIOSTOP 500+ Intumescent Firestop Sealant to meet NEC #300.21, ASTM #E814, UL #1479 & UL #2079 standards 4” extruded aluminum frame able to accept aside loading face painted to match PMS 293 Op x 7328LD White(non glare) Sloan Prism 5000K LED Primary Power In Self-contained power supply 120V 20A Toggle Switch (2) 1/4” Weep holes w/ internal light baffle 3mm Di-bond laird part #79698 Anchors as required. (See hardware chart.) #12 THHN primary wire inside ½”aluminum conduit Building facade. CMU - brick. Typ. 1 2 3 4 5 6 7 8 9 10 11 Detail of Shield Logo N.T.S. WALL 4” 10 8 8 3 7 1 5 2 9 4 11 6 DRIVE THRU PHARMACY Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 DRIVE THRU PHARMACYDRIVETHRUPHARMACY EXISTING SIGNAGE Existing Sq Ft: 50.5 E4: NORTH DTP-> 15' 9 1/8" X 13 3/8" H E13: WEST DTP-> 15'9 1/8" X 13 3/8" H E14: DTP CHANNEL LETTERS 13'11"X 13 3/8" H E15: PICK UP WALL PLAQUE E16: CLEARANCE WALL PLAQUE E17: DROP OFF WALL PLAQUE PROPOSED SIGNAGE NOTE: NEW signs to include all power supplies. Proposed Sq. Ft: 136.1 R4: NEW RA-DT-SF-WS illuminated wall sign flush mounted R13: NEW RA-DT-SF-WS illuminated wall sign flush mounted R14: REMOVE R15: RA-DT-LN-1 R16: RA-DT-CL R17: RA-DT-LN-2 12 Sq.Ft. | Box Measured 12 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured 6.78 Sq.Ft. | Box Measured E15 E16 E17 E14 EXISTING R15 R16 R17 PROPOSED Colors and textures are for representational purposes only. Copyright © Integrated Image 2020.All Rights Reserved. No part of this drawing may be reproduced without Integrated Image’s express consent. Project Store #06548 14115 LAKERIDGE CIRCLE MAGALIA, CA 95954 For use with concrete, masonry & brick.Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HLC SLEEVE ANCHOR For use with concrete block. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with masonry & brick. Embed a minimum of 3 3/8 ” ¼” DIA. HILTI HIT ROD W/HY20 ADHESIVE For use with concrete. Embed a minimum of 2” ¼” DIA. HILTI HIT ROD W/HY150MAX ADHESIVE For use with concrete block, brick, or concrete.Embed a minimum of 2½” ¼” RED HEAD L.D.T. (Large Diameter Tapcon) For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD For use with wood, concrete block orEIFS Wall systems ¼” DIA. THREADED ROD & BEARING PLATES For use with wood or EIFS Wall Systems 1½” Minimum Penetration (Excluding tip) ¼” LAG SCREW Fastener Schedule R15 R17 R16 EXISTING SIGNAGE E14: DTP CHANNEL LETTERS 13'11"X 13 3/8" H E15: PICK UP WALL PLAQUE E16: CLEARANCE WALL PLAQUE E17: DROP OFF WALL PLAQUE PROPOSED SIGNAGE R4: NEW RA-DT-SF-WS illuminated wall sign flush mounted R11: NEW RA-LNR-5WH channel letters R13: NEW RA-DT-SF-WS illuminated wall sign flush mounted R14: REMOVE R15: RA-DT-LN-1 DRIVE THRU PHARMACY CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards November 2019STATE OF CALIFORNIA Sign LightingNRCC-LTS-E (Created 11/19) CALIFORNIA ENERGY COMMISSIONPage 1 of 5CERTIFICATE OF COMPLIANCENRCC-LTS-EThis document is used to demonstrate compliance with requirements in §110.9, §110.12, §130.0, §130.3, §140.8, and §141.0(b)2M for sign lighting scopes using the prescriptive path. Exit signs and traffic signs are not required to comply with prescriptive requirements per exceptions to §140.8 and do not need to complete this compliance document.Project Name:Rite AidReport Page:Project Address:14115 Lakeridge Cir.Date Prepared:9/15/2020A. GENERAL INFORMATION 01Project Location (city)Magalia02Climate Zone1103Building is a healthcare facilityB. PROJECT SCOPE Table Instructions: Include any illuminated signs that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in §140.8 or §141.0(b)2M for alterations. Exit signs and traffic signs are not required to comply with prescriptive requirements per exceptions to §140.8 and do not need to complete this compliance document. WARNING: Changing the Compliance Method in this table will result in the deletion of data previously input. If you need to change the compliance method, please open a new form or use "Save As".01Name or Item Tag02Complete Sign Description03Sign Status¹04Sign Type05Compliance Method²R4"Drive Thru" wall signNewOutdoorAlternate Light SourcesR5"Rite Aid" wall signNewOutdoorAlternate Light SourcesR7"Thrifty" wall signNewOutdoorAlternate Light SourcesR8"Pharmacy" wall signNewOutdoorAlternate Light SourcesR10"Drive Thru" wall signNewOutdoorAlternate Light SourcesR11"Rite Aid" wall signNewOutdoorAlternate Light SourcesR13"Drive Thru" wall signNewOutdoorAlternate Light Sources ¹FOOTNOTE: Sign alterations that increase the connected lighting load, replace and rewire more than 50% of the ballasts, or relocate the sign to a different location must comply with §140.8. See §141.0(b)2M for more details. ²The ENERGY VERIFIED Label compliance method is only applicable if the sign has a permanent, factory-installed, ENERGY VERIFIED label certified by UL or comparable, confirming the sign complies with §140.8. Note that using an ENERGY VERIFIED label is an optional compliance path, not a mandatory requirement. See the tool tips for this table for more details.C. COMPLIANCE RESULTS Table Instructions: If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance. Table Continued CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standardsNovember 2019STATE OF CALIFORNIA Sign LightingNRCC-LTS-E (Created 11/19) CALIFORNIA ENERGY COMMISSIONPage 2 of 5CERTIFICATE OF COMPLIANCENRCC-LTS-EProject Name:Rite AidReport Page:Project Address:14115 Lakeridge Cir.Date Prepared:9/15/2020Table ContinuedName or Item Tag(See Table B)01(See Table B)Complete Sign Description02(See Table F)Total Allowed (Watts) 03≥(See Table F)Total Designed (Watts) 04OR(See Table G)Compliant Light Sources05OR(See Table H)ENERGY VERIFIED Label06Compliance Results07R4"Drive Thru" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR5"Rite Aid" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR7"Thrifty" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR8"Pharmacy" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR10"Drive Thru" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR11"Rite Aid" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESR13"Drive Thru" wall sign≥ORYESORCOMPLIESControls Compliance (See Table F/G/H for Details) COMPLIESD. EXCEPTIONAL CONDITIONSThis table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. No exceptional conditions apply to this project.E. ADDITIONAL REMARKSThis table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. MAXIMUM ALLOWED LIGHTING POWER AND CONTROLSThis Section Does Not Apply CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standardsNovember 2019STATE OF CALIFORNIA Sign LightingNRCC-LTS-E (Created 11/19) CALIFORNIA ENERGY COMMISSIONPage 3 of 5CERTIFICATE OF COMPLIANCENRCC-LTS-EProject Name:Rite AidReport Page:Project Address:14115 Lakeridge Cir.Date Prepared:9/15/2020G. LIGHT SOURCES AND CONTROLSTable Instructions: Complete this table for illuminated signs using the Alternate Lighting Sources compliance method per §140.8(b) as indicated on Table B of this compliance document. Also demonstrate compliance with mandatory controls requirements from §130.3 by indicating control types for each sign.01Name or Item Tag02Complete Sign Description 03Compliant Light Sources¹04Shut-OffDimmingDemand Response³Mandatory Controls05Field InspectorPassFailR4"Drive Thru" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R5"Rite Aid" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R7"Thrifty" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R8"Pharmacy" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R10"Drive Thru" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R11"Rite Aid" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1R13"Drive Thru" wall signLED + pwr supply 80%+ eff. Auto Timer + PhotocontrolPwr. reduced 65%+NA 1*NOTE: Selections with a * require a note in the space below explaining how compliance is achieved. EX: Sign within tunnel illuminated day & night; EXCEPTION to §130.3(a)2A. ¹FOOTNOTE: Dropdown choices have been abbreviated, please refer to §140.8(b) to confirm compliance with the specific light source technologies listed. ² Authority having jurisdiction may ask for cutsheets to confirm compliance of light source. ³ Demand response controls are only required for an Electronic Message Center having a new connected lighting power load greater than 15 kW per §110.12(d). H. ENERGY VERIFIED LABELED SIGNS AND CONTROLSThis Section Does Not Apply CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standardsNovember 2019STATE OF CALIFORNIA Sign LightingNRCC-LTS-E (Created 11/19) CALIFORNIA ENERGY COMMISSIONPage 4 of 5CERTIFICATE OF COMPLIANCENRCC-LTS-EProject Name:Rite AidReport Page:Project Address:14115 Lakeridge Cir.Date Prepared:9/15/2020●I. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Table Instructions: Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCI/YESNOForm/TitleField InspectorPassFailNRCI-LTS-01-E - Must be submitted for all buildings.J. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCEThere are no Certificates of Acceptance applicable to sign lighting requirements. CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards November 2019STATE OF CALIFORNIA Sign LightingNRCC-LTS-E (Created 11/19) CALIFORNIA ENERGY COMMISSIONPage 5 of 5CERTIFICATE OF COMPLIANCENRCC-LTS-EProject Name:Rite AidReport Page:Project Address:14115 Lakeridge Cir.Date Prepared:9/15/2020DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and completeDocumentation Author Name:Michael FordDocumentation Author Signature:Michael FordCompany:Coast SignSignature Date:9/15/2020Address:1500 W. Embassy St.CEA/ HERS Certification Identification (if applicable):City/State/Zip:Anaheim, CA 92802Phone:(714) 520-9144RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct.2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer)3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.5.I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.Responsible Designer Name:Michael FordResponsible Designer Signature:Michael FordCompany :Coast SignDate Signed:9/15/2020Address:1500 W. Embassy St.License:654238City/State/Zip:Anaheim, CA 92802Phone:(714) 520-9144