Loading...
HomeMy WebLinkAboutA20-0003_Packet_10-21-20  Butte County Department of Development Services  Airport Land Use Commission   Lewis A20-0003  Page 1 of 3  Butte County Department of Development Services Planning Division Airport Land Use Commission October 21, 2020 Meeting AGENDA ITEM – D.1 TO: Honorable Chair and Airport Land Use Commission FROM: Mark Michelena, Senior Planner DATE: October 21, 2020 ITEM: ALUC File No. A20-0003 (William Lewis), APN 047-600-007: A height review for a proposed 90-foot tall communication facility (mono pine stealth tower) on APN 047-600-007, 4338 Shorthorn Drive – 5.65 acres. The parcel is located within Compatibility Zone C of the Chico Municipal Airport. The parcel is located on the north side of Shorthorn Drive, approximately 600 feet east of Hereford Drive, north and west of the City of Chico. SUMMARY: Staff recommends that ALUC find height review consistent with the 2017 Airport Land Use Compatibility Plan for the Chico Municipal Airport. BACKGROUND:  The project site is approximately 5.65 acres.  The parcel is developed with a single-family dwelling  The property is located in the unincorporated area of the County, north and west of the City of Chico. It is zoned VLDR /SR-1 (NCSP)/AOC (Very Low Density Residential/Suburban Residential 1-acre minimum (North Chico Specific Plan)/Airport Overlay C and has a General Plan Land Use Designation of VLDR (Very Low Density Residential).  The proposed project is a 90-foot tall communication facility (faux tree) and ground related equipment located in a 625 square foot leased area (25’ x 25’). ANALYSIS:  APN 047-600-007 is located within the C Compatibility Zone.  Butte County Department of Development Services  Airport Land Use Commission   Lewis A20-0003  Page 2 of 3   The project site area is approximately 10,160 feet northwest of runway 13L – 31R for the Chico Municipal Airport and is located approximately 5,300 feet west of the extended runway centerline.  The project site area is approximately 11,400 feet northwest of runway 13R – 31L for the Chico Municipal Airport and is located approximately 4,600 feet west of the extended runway centerline.  The C Compatibility Zone requires height review for objects greater than 70 feet.  The Butte County Airport Land Use Compatibility Plan (BCALUCP) identities Airspace Protection Policies to address structures that exceed the height maximum per the Compatibility Zone. Policy Objective – Airspace protection compatibility policies seek to prevent creation of land use features that can pose hazards to the airspace required by aircraft in flight and have the potential for causing aircraft accident. Measures of Hazardous to Airspace –  Physical hazards include tall structures that have the potential to intrude upon protected airspace as well as land use features that have the potential to attract birds or other potentially hazardous wildlife to the airport area.  Visual hazards include certain types of lights, sources of glare, and sources of dust, steam or smoke,  Electronic hazards are ones that may cause interference with aircraft communications.  The project site is located at approximately 200 feet above sea level. While the existing runways are approximately 225 and 230 feet above sea level.  The proposed communication facility exceeds Compatibility Zone C height of 70 feet by 20 feet.  The communication facility will not attract birds or other hazardous wildlife to the airport area.  The proposed communication facility will not create visual hazards, such as light, sources of glare, and sources of dust, stream or smoke. The project will generate very little land disturbance or light. No steam or smoke will be generated by the communication facility.  BCALUCP Section 3.5.1 - Evaluating Airspace Protection/Object Height Compatibility for New Development: (a) The policies of this Section, together with the Airspace Protection Surfaces Map drawn in accordance with FAR Part 77, Subpart C and reflecting the runway length, runway end locations, and approach type for each end of the runways as identified on Map CIC-4.1B for the Chico Municipal Airport (c) The Critical Airspace Protection Zone consists of the FAR Part 77 primary surface and the area beneath portions of the approach and transitional surfaces to where these surfaces intersect with the horizontal surface together with the Height Review Overlay Zone. (d) The Height Review Overlay Zone encompasses locations where the ground elevation  Butte County Department of Development Services  Airport Land Use Commission   Lewis A20-0003  Page 3 of 3  exceeds or is within 35 feet beneath the Airspace Protection Surface as defined by FAR Part 77 for the airport.  BCALUCP Section 3.5.2 – Object Height Criteria – The criterial for determining the acceptability of a Project with the respect height are as follows: (a) Except as provided in Paragraphs (b) and (c) of this policy, no object, including mobile object as a vehicle or temporary object such as a construction crane, shall have a height that would result in a penetration of an Airspace Protection Surface. Any object that penetrates one of these surfaces is, by FAA definition, deemed an obstruction. (e) The Critical Airspace Protection Zone consists of the FAR Part 77 primary surface and the area beneath portions of the approach and transitional surfaces to where these surfaces intersect with the horizontal surface together with the Height Review Overlay Zone. (f) The Height Review Overlay Zone encompasses locations where the ground elevation exceeds or is within 35 feet beneath the Airspace Protection Surface as defined by FAR Part 77 for the airport.  The project site elevation is 200 feet above sea level. Per BCAUCP Exhibit CIC-4.1B Airspace Protection Surfaces Map, based on FAA Part 77, the Airspace Protection Area starts at 390 feet above sea level. With the height of the communication facility (90 feet), the highest point would be 290 feet about sea level. This would be 100 feet below the Airspace Protection Area.  The project site is located in is located in the Traffic Pattern Zone, which is outside the Runway Protection Zone, Inner Approach/Departure Zone, Inner Turning Zone, Outer Approach/Departure Zone and Sideline Zone. ENVIRONMENTAL DOCUMENTATION: No environmental documentation has been completed for this project by ALUC staff. The Butte County Planning Division will determine the requirements of the California Environmental Quality Act Guidelines upon review of the Conditional Use Permit. RECOMMENDATION: Staff recommends that the Butte County Airport Land Use Commission find ALUC File No. A20- 0003 (William Lewis) consistent with the height review requirements of the 2017 Airport Land Use Compatibility Plan for the Chico Municipal Airport. Attachments: A: Findings with Conditions B: List of References C: Project Location and Compatibility Zones D: Aerial E: Application ATTACHMENT A BUTTE COUNTY AIRPORT LAND USE COMMISSION CONSISTENCY FINDINGS FOR: ALUC File No. ALUC20-0003 (William Lewis) The Airport Land Use Commission (ALUC) has prepared the following findings based on data contained in the 2017 Airport Land Use Compatibility Plan (ALUCP) for the Chico Municipal Airport, as well as site specific information submitted by the applicant and ALUC staff. The following findings have been prepared at the direction of the ALUC and are for the consideration of the Lead Agency (Butte County) when making a decision on the project. SECTION 1: ENVIRONMENTAL FINDINGS A. No environmental documentation has been completed for this project by ALUC staff. Butte County will determine the environmental Review for the proposed Use Permit. SECTION 2: CONSISTENCY FINDING FOR PROPOSED PROJECT A. The communication facility will not attract birds or other hazardous wildlife to the airport area. B. The proposed communication facility will not create visual hazards, such as light, sources of glare, and sources of dust, stream or smoke. The project will generate very little land disturbance or light. No steam or smoke will be generated by the communication facility. C. The project site elevation is 220 feet above sea level. Per BCAUCP Exhibit CIC- 4.1B Airspace Protection Surfaces Map, based on FAA Part 77, the Airspace Protection Area starts at 390 feet above sea level. With the height of the communication facility (90 feet), the highest point would be 290 feet about sea level. This would be 100 feet below the Airspace Protection Area. D. The project site is located in is located in the Traffic Pattern Zone, which is outside the Runway Protection Zone, Inner Approach/Departure Zone, Inner Turning Zone, Outer Approach/Departure Zone and Sideline Zone. ATTACHMENT B List of References Data supporting the ALUC’s findings have been generated from studies and reports prepared by recognized professionals and agencies with expertise in Airport Land Use Planning and land use compatibility. These include, but are not limited to: Butte County 2017 Airport Land Use Compatibility Plan ATTACHMENT C Project Location and Compatibility Zones ATTACHMENT D Aerial ATTACHMENT E Application BUTTE. COUNTY AIRPORT LAND USE COMMISSION 7 COUNTY CENTERDIUV;E, OROVILLE, CA 9�965. ···· . :. :APPLICATION FORCONSISTENCYiFINDn��:cs:.,: .. > ALUC Identification # I PROJECT PROPONENT . , Property Owner: William Lewis Date of Application: 9/1/20 Mailing Address: 9 Spciogbrook Ct. Phone Number: (530) 321-2919 Cit�{ Chico State: CA Zi�: 95926 E-mail Address: wmlewis@sbcglobal.net Agent (if any) SAC Wireless Phone Number: 312.690.4573 Mailing Address: E-mail Address:�eter. ferreri(ci2sacw .com 8880 Cal Center Drive, Suite 170, Sacramento, CA 95826 " '.-. Parcel Size 5.65 jPROJECT LOCATION .. Street Address: 4338 Shorthorn Court Chico CA 95973 Assessor's Parcel No. 047-600-007 Subdivision Name: jPROJECT DESCRIPT_ION Zoning: \ll DB \lecy. LrnllL Deosity. Bes SITE PLAN: Attach 2 copies of an The Commission shall identify and prioritize studies, plans and other related activities they desire to be performed in the upcoming fiscal year. accurately-scaled, detailed site plan showing location of structures, open spaces, and the height of structures and trees; include additional project description data as needed. Phrn sheets shall be no larger than 11 "xl 7" and a digital copy is encoural!ed. Flight Hazards: Does the project involve any characteristics which could create electrical interference, confusing lights, glare, smoke, or other electrical or visual hazards to aircraft flight? D Yes 51 No Does the project have the potential for attracting birds? D Yes I]! No If yes to either, explain below: Height Data: Height above Ground of Tallest Object (including antennas & trees) 90' ft. I I A20-0003 LAND USE SUMMARY Size Total Density Existing Land Use Proposed Zoning (acres) Dwelling (dwelling Units units/acre) VLDR N/A II 5.65 II N/A I IN/A I I II II I I I !II I I II I II II I Examples of Land Use: Parks, Roads. Commercial. Low Density Residential, Schools, Industrial. Open Space Reserve, Public Facilities. etc. Examples of Zoning: R-1 (Single Family Residential), PUD (Planned Unit Development), C-2 (General Commercial), A-R (Agricultural Residential). etc. For non-residential land uses, indicate the maximum number of people on site and indicate the method used to determine this number (i.e. church membership, number of parking spaces, etc.) EACILIIY IS U�MA��ED A�D �or E08 t:f lJMA� t:fABIIAIIO� ACCESSIBII IIY �QI 8EOU18ED Signature Date__gW2() (Project Proponent) REFERRING AGENCY (TO BE COMPLETED BY AGENCY STAFF) Date Received Type of project: Agency's Project Number D General Plan Amendment D Zoning Amendment Agency Name D RezoneD Subdivision Staff Contact D Use PermitD Public Facility Phone Number D Other ALUC Fee Collected$ G \PLANNING\FORMS\APPLICATJONS\DPL_Planning Forms\Word Documcnts\DPL-18_Airport Land Use Commission Consistency Review.doc NORTH 1 LE-1 LEASE EXHIBIT SITE PLAN SCALE:1" = 80'-0" (8 1/2x11) APN: 047-600-007 OWNER(S): WILLIAM M. LEWIS & JOANN LEWIS, TRUSTEES OF THE LEWIS FAMILY TRUST NEW VERIZON WIRELESS EQUIPMENT & ANTENNA AREA, REFER TO: 1 LE-2 APN: 047-600-013 PROPERTY LINE KEEFER SHEET TITLE:ISSUE STATUS 2785 MITCHELL DRIVE, BLDG 9 WALNUT CREEK, CA 94598 4338 SHORTHORN DR. CHICO, CA 95973 PSL# 491608 DESCRIPTIONDATE BYREV. 06/11/20 FA0LEASE EXHIBIT TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 08/20/20 FA1LEASE EXHIBIT EXISTING TRANSFORMER T-3080 (NEW VERIZON WIRELESS POWER P.O.C.) NEW VERIZON WIRELESS U/G ELECTRICAL ROUTE, BORING METHOD IS USED (±455 FT) SH O R T H O R N D R I V E CL NEW VERIZON WIRELESS 5'-0" WIDE UTILITY EASEMENT RIGHT-OF- WAY EXISTING RESIDENCE EXISTING 5'-0" HIGH WOOD FENCENEW VERIZON WIRELESS 17"X30" FIBER VAULT, (4) TOTAL (NEW VERIZON WIRELESS POWER P.O.C.) EXISTING TELCO RISER EXISTING TELCO RISER EXISTING U/G COMM. LINE EXISTING U/G ELEC. LINE EXISTING TREE (TYP.) NEW VERIZON WIRELESS SITE ACCESS DRIVEWAY EXISTING 5'-0" HIGH CHAIN-LINK FENCE (E) SEE TRAINEDGE OF PAVEMENT 60'-0" EASEMENT FORINGRESS, EGRESS ANDPUBLIC UTILITIES PERSER. #86-42648, O.RBUILDING SETBACK LINE BIRDSEYE COURTAPN: 047-600-010APN: 047-600-012 APN: 047-600-001 APN: 047-600-008PROPERTY LINE PROPERTY LINEPROPERTY LINE90'-0"90'-0"BUILDING SETBACK LINE EDGE OF PAVEMENT NEW VERIZON WIRELESS 12'-0" WIDE CLASS II ACCESS EASEMENT RIGHT-OF- WAY 30'-0"30'-0"EXISTING CONC. AREA 5'-0" 12'-0" NEW VERIZON WIRELESS U/G FIBER ROUTE (±415 FT)EXISTING PAVED DRIVEWAY25'-0" NORTH 1LEASE EXHIBIT LEASE AREA PLAN LE-2 SCALE:3/32" = 1'-0" (8 1/2x11) NEW VERIZON WIRELESS 625 SQ FT EQUIPMENT & ANTENNA AREA KEEFER SHEET TITLE:ISSUE STATUS 2785 MITCHELL DRIVE, BLDG 9 WALNUT CREEK, CA 94598 4338 SHORTHORN DR. CHICO, CA 95973 PSL# 491608 DESCRIPTIONDATE BYREV. 06/11/20 FA0LEASE EXHIBIT TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 08/20/20 FA1LEASE EXHIBIT APN: 047-600-007 OWNER(S): WILLIAM M. LEWIS & JOANN LEWIS, TRUSTEES OF THE LEWIS FAMILY TRUST NEW VERIZON WIRELESS U/G ELECTRICAL ROUTE, BORING METHOD IS USED (±455 FT) NEW VERIZON WIRELESS 5'-0" WIDE UTILITY EASEMENT RIGHT-OF- WAY NEW VERIZON WIRELESS 12'-0" WIDE ACCESS EASEMENT RIGHT-OF- WAY 25'-0" NEW VERIZON WIRELESS LEASE AREA 25'-0"NEW VERIZON WIRELESS LEASE AREA5'-0"12'-0" NEW VERIZON WIRELESS U/G FIBER ROUTE (±415 FT) KEEFER PSL # 491608 4338 SHORTHORN DR. CHICO, CA 95973 T-1 TITLE SHEET PROJECT DESCRIPTION CONSTRUCTION: RADIO: VERIZON WIRELESS SIGNATURE BLOCK DISCIPLINE:SIGNATURE:DATE: EQUIPMENT: SITE ACQUISITION: MICROWAVE: TELCO: WO ADMINISTRATOR: PROJECT ADMINISTRATOR: CODE COMPLIANCE DRIVING DIRECTIONS PROPERTY INFORMATION: SITE NAME:KEEFER SITE NUMBER: 491608 SITE ADDRESS:4338 SHORTHORN DR. CHICO, CA 95973 JURISDICTION: TO:4338 SHORTHORN DR. CHICO, CA 95973 A-1 A-3 SHEET T-1 DESCRIPTION TITLE SHEET PLANNER: CONSTRUCTION: SAC WIRELESS SIGNATURE BLOCK DISCIPLINE:SIGNATURE: SITE ACQUISITION: LANDLORD: SOUTH & WEST ELEVATIONS SITE PLAN DATE: A-4 NORTH & EAST ELEVATIONS A-2 EQUIPMENT & ANTENNAS LAYOUTS GENERAL CONTRACTOR NOTES ZONING DRAWINGS DO NOT SCALE DRAWINGS IF NOT FULL SIZE (24 X 36) CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. ASSESSOR'S PARCEL NUMBER CURRENT ZONING: TYPE OF CONSTRUCTION: AREA OF CONSTRUCTION: V-B 25'-0" x 25'-0" = 625 SQ FT 047-600-007 VLDR CONSTRUCTION INFORMATION OCCUPANCY:U APPLICANT/LESSEE 2785 MITCHELL DRIVE, BLDG 9 WALNUT CREEK, CA 94598 OFFICE: (925) 279-6000 APPLICANT'S REPRESENTATIVE PROPERTY OWNER: PROJECT SUMMARYPROJECT TEAM ARCHITECT:SURVEYOR: UTILITY COORDINATOR: PLANNINGSITE ACQUISITION Call before you dig. below.Know what's R TO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN CALIFORNIA (NORTH & CENTRAL) , CALL USA NORTH 811 TOLL FREE: 1-800-227-2600 OR www.usanorth811.org CALIFORNIA STATUTE REQUIRES MIN OF 2 WORKING DAYS NOTICE BEFORE YOU EXCAVATE THIS PROJECT IS A VERIZON WIRELESS UNMANNED TELECOMMUNICATION WIRELESS FACILITY. IT WILL CONSIST OF THE FOLLOWING: ·NEW VERIZON WIRELESS 25'-0" x 25'-0" LEASE AREA ·NEW VERIZON WIRELESS 8'-0" TALL CHAIN-LINK FENCE ·NEW VERIZON WIRELESS OUTDOOR EQUIPMENT 15'-0" X 8'-0" CONCRETE PAD ·NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLON DIESEL TANK (UL142) ON NEW 5'-0" X 10'-0" CONCRETE PAD ·(1) NEW VERIZON WIRELESS GPS ANTENNA ·(1) NEW VERIZON WIRELESS ELECTRICAL METER ON NEW H-FRAME ·(1) NEW VERIZON WIRELESS INTERSECT CABINET ON NEW H-FRAME ·(1) NEW VERIZON WIRELESS TELCO BOX ON NEW H-FRAME ·(1) NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE ·(9) NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS ·(12) NEW VERIZON WIRELESS RADIOS ·(2) NEW VERIZON WIRELESS RAYCAPS 6627 ·(2) NEW VERIZON WIRELESS HYBRID CABLES VICINITY MAP EQUIPMENT ELEVATIONSA-5 BUTTE COUNTY SMITHCO SURVEYING ENGINEERING P.O. BOX 81626 BAKERSFIELD, CA 93380 CONTACT: GREG SMITH, PLS TELEPHONE: (661) 393-1217 GSMITH@SMITHCO.NET SAC WIRELESS, LLC. 8880 CAL CENTER DRIVE SUITE 170 SACRAMENTO, CA 95826 CONTACT: RAMON MORENO TELEPHONE: (916) 751-8827 RAMON.MORENO@SACW.COM ACCESSIBILITY REQUIREMENTS:FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. ACCESSIBILITY NOT REQUIRED. ·2019 CALIFORNIA ADMINISTRATIVE CODE ·2019 CALIFORNIA BUILDING CODES ·2019 CALIFORNIA ELECTRICAL CODE ·2019 CALIFORNIA FIRE CODE ·2019 CALIFORNIA ENERGY CODE ·CITY & COUNTY ORDINANCES ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. ALL WORK SHALL CONFORM TO 2019 EDITION TITLE 24, CALIFORNIA CODE OF REGULATIONS. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. 1.HEAD NORTHEAST ON MITCHELL DR TOWARD OAK GROVE RD 2.TURN LEFT ONTO OAK GROVE RD 3.TURN LEFT ONTO TREAT BLVD 4.TURN RIGHT ONTO BUSKIRK AVE 5.TAKE THE RIGHT TOWARDS I- 680 N 6.KEEP LEFT AT THE FORK TO STAY ON I-680 N 7.TAKE EXIT 71A ON THE RIGHT TOWARD I-80 E 8.TAKE EXIT 56 FOR I-505 N 9.MERGE ONTO I-5 N 10.TAKE EXIT 569 FOR HAHN RD 11.TURN RIGHT ONTO HAHN RD 12.TURN LEFT ONTO LONE STAR RD 13.TURN RIGHT ONTO STATE HWY 20 E 14.TURN LEFT ONTO MARKET ST 15.CONTINUE ONTO CA-45 N/13TH ST 16. CONTINUE TO FOLLOW CA-45 N 17.TURN RIGHT ONTO CA-32 E/6TH ST 18. CONTINUE TO FOLLOW CA-32 E 19.TURN LEFT ONTO MERIDIAN RD 20.TURN RIGHT ONTO WILSON LANDING RD 21.TURN LEFT ONTO CA-99 N 22.TURN RIGHT ONTO GARDEN BROOK DR 23.TURN LEFT ONTO HEREFORD DR 24.TURN RIGHT INTO SHORTHORN DR 25.DESTINATION WILL BE ON THE LEFT NOT TO SCALE NORTH OWNER:WILLIAM M. LEWIS & JOANN LEWIS, TRUSTEES OF THE LEWIS FAMILY TRUST ADDRESS:9 SPRINGBROOC CT. CHICO, CA 95926 PHONE:(530) 321-2919 EMAIL:wmlewis@sbcglobal.net SAC WIRELESS, LLC. 8880 CAL CENTER DRIVE SUITE 170 SACRAMENTO, CA 95826 CONTACT: WARREN SHEW TELEPHONE: (312) 895-4977 EXT. 9555 WARREN.SHEW@SACW.COM SAC WIRELESS, LLC. 8880 CAL CENTER DRIVE SUITE 170 SACRAMENTO, CA 95826 CONTACT: WARREN SHEW TELEPHONE: (312) 895-4977 EXT. 9555 WARREN.SHEW@SACW.COM SAC WIRELESS, LLC. 8880 CAL CENTER DRIVE SUITE 170 SACRAMENTO, CA 95826 CONTACT: WARREN SHEW TELEPHONE: (312) 895-4977 EXT. 9555 WARREN.SHEW@SACW.COM FROM:2785 MITCHELL DRIVE, BLDG 9 WALNUT CREEK, CA 94598 NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING C-1 SITE SURVEY C-2 SITE SURVEYSITE SAC AE DESIGN GROUP, INC NESTOR POPOWYCH, AIA 5015 SHOREHAM PLACE SUITE 150 SAN DIEGO, CA 92122 CONTACT: JULIAN BRIANO TELEPHONE: (760) 219-9269 FAX: (619) 736-3106 JULIAN.BRIANO@SACW.COM 1-LINE DIAGRAM, PANEL SCHEDULE & UTILITY NOTESE-1 SITE PLAN A-11 NORTH 1" = 30'-0" (24x36) (OR) SCALE: 1/2" = 30'-0" (11x17) 30'15'30'0 NEW VERIZON WIRELESS EQUIPMENT & ANTENNA AREA, REFER TO: 1 A-2 1 A-3 2 A-4 2 A-3 1 A-4 APN: 047-600-007 OWNER(S): WILLIAM M. LEWIS & JOANN LEWIS, TRUSTEES OF THE LEWIS FAMILY TRUST SITE PLAN EXISTING TRANSFORMER T-3080 (NEW VERIZON WIRELESS POWER P.O.C.) LESSEE PROPOSED 12'-0" WIDE CLASS II ACCESS EASEMENT RIGHT-OF- WAY NEW VERIZON WIRELESS U/G ELECTRICAL ROUTE, BORING METHOD IS USED (±455 FT)NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING SH O R T H O R N D R I V E CL APN: 074-600-008 LESSEE PROPOSED 5'-0" WIDE UTILITY EASEMENT RIGHT-OF- WAY EXISTING RESIDENCEPROPERTY LINENEW VERIZON WIRELESS U/G FIBER ROUTE (±415 FT)EXISTING 5'-0" HIGH WOOD FENCENEW VERIZON WIRELESS 17"X30" FIBER VAULT, (4) TOTAL (NEW VERIZON WIRELESS POWER P.O.C.) APN: 074-600-001 APN: 074-600-013 APN: 074-600-012 APN: 074-600-010 BIRDSEYE COURT90'-0"90'-0" EXISTING TELCO RISER EXISTING TELCO RISER EXISTING U/G COMM. LINE EXISTING U/G ELEC. LINE EXISTING ACCESS DRIVEWAY EXISTING TREE PROPERTY LINE PROPERTY LINEPROPERTY LINE EXISTING TREE (TYP.) NEW VERIZON WIRELESS SITE ACCESS DRIVEWAY EXISTING 5'-0" HIGH CHAIN-LINK FENCE EXISTING 5'-0" HIGH CHAIN-LINK FENCE(E) SEE TRAINEXISTING CONC. AREA EXISTING PAVED DRIVEWAYEDG E O F P A V E M E N T ED G E O F P A V E M E N T EDGE OF PAVEMENT EDGE OF PAVEMENT DUI L D I N G S E T B A C K L I N E 30'-0"60'-0" EASEMENT FORINGRESS, EGRESS ANDPUBLIC UTILITIES PERSER. #86-42648, O.R50'-0"30'-0"30'-0"BUILDING SETBACK LINE BUILDING SETBACK LINE60'-0"5'-0" "GAMMA" SECTOR @ 265 ° ALPHA" SECT O R @ 8 0 ° "BE TA " SECTOR @ 150 ° MICROWAVE @ 90°MICROWAVE @ 33 0 ° 12'-0" EQUIPMENT & ANTENNA LAYOUTS 3/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3'A-21EQUIPMENT LAYOUT2PANEL ANTENNA LAYOUT 3/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3' NORTH PANEL ANTENNAS @ 81'-0" CENTERLINE NEW VERIZON WIRELESS ELECTRICAL METER, TELCO BOX & INTERSECT CABINET W/GENERATOR RECEPTACLE ON NEW H-FRAME NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE (ANTENNAS NOT SHOWN FOR CLARITY) REFER TO: NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 15'-0" X 8'-0" CONCRETE PAD NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA 2 - NEW VERIZON WIRELESS GPS ANTENNA, (1) TOTAL NEW VERIZON WIRELESS SERVICE LIGHTS W/6-HOUR TIMER, (4) TOTAL OUTLINE OF NEW VERIZON WIRELESS MONOPINE BRANCHES (SHOWN DASHED FOR CLARITY) NEW VERIZON WIRELESS KNOX BOX NEW PORTABLE FIRE EXTINGUISHER (CLASS 4A-60BC) "GAMMA" SECTOR @ 26 5 ° ALPHA" SECTO R @ 8 0 ° "BETA " SECTOR @ 1 50 ° NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS, (9) TOTAL, (3) PER SECTOR NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE NEW VERIZON WIRELESS RADIOS, (12) TOTAL, (4) PER SECTOR, (9) LICATED BEHIND ANTENNAS & (3) LOCATED ON NEW RADIO DUAL PIPE RING MOUNT R12'-0"MAX.R7'-0"MIN.25'-0"NEW VERIZON WIRELESS LEASE AREANEW VERIZON WIRELESS 17"X30" FIBER VAULT, (4) TOTAL 12'-6"12'-6"R12'- 0 " MAX. R 7 ' - 0 " MI N .R3'- 0 " NEW VERIZON WIRELESS ICE-BRIDGE W/(2) HYBRID CABLESFIBERRBOX INTERSECTCABINETMETERNORTH POWER/ MISC CAB. FUTURE MISC. CAB.NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING OUTLINE OF NEW VERIZON WIRELESS MONOPINE BRANCHES (SHOWN DASHED FOR CLARITY) BATTERY/ CAB.NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE 2'-0"15'-0" 9"3'-0"NEW VERIZON WIRELESS 12'-0" WIDE CHAIN-LINK ACCESS GATE 1'-0"1'-0"1'-0"8"8'-0"1'-0"3'-6"25'-0" NEW VERIZON WIRELESS LEASE AREA 8'-0"4"1'-4"LESSEE PROPOSED 12'-0" WIDE CLASS II ACCESS EASEMENT RIGHT-OF- WAY NEW VERIZON WIRELESS U/G ELECTRICAL ROUTE, BORING METHOD IS USED (±455 FT) LESSEE PROPOSED 5'-0" WIDE UTILITY EASEMENT RIGHT-OF- WAY NEW VERIZON WIRELESS U/G FIBER ROUTE (±748 FT) 8" NEW VERIZON WIRELESS CLASS II THROUGHOUT EQUIPMENT ENCLOSURE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS 15KW DC POLAR STANDBY GENERATOR W/54 GALLON DIESEL TANK (UL142) ON NEW 15'-0" X 8'-0" CONCRETE PAD 1/4" = 1'-0" (11x17) SCALE: (OR) 1/2" = 1'-0" (24x36)0 6"1'2'2MICROWAVE ANTENNA LAYOUT MICROWAVE @ 90°MICROWAVE @ 330 ° MICROWAVE ANTENNAS @ 71'-0" CENTERLINE FUTURE MISC. CAB. 2'-0"10'-0"2'-0"5'-0"STANDBY 30KW AC GENERATOR NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLON DIESEL TANK (UL142) ON NEW 5'-0" X 10'-0" CONCRETE PAD10"TYP.1'-10"TYP.1'-10"TYP.10"TYP.3'-8"TYP.NEW VERIZON WIRELESS 2'Ø MICROWAVE ANTENNA, (1) TOTAL NEW VERIZON WIRELESS 6'Ø MICROWAVE ANTENNA, (1) TOTAL NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE NORTH OUTLINE OF NEW VERIZON WIRELESS MONOPINE BRANCHES (SHOWN DASHED FOR CLARITY) 6" NORTH & EAST ELEVATIONS 2 3/32" = 1'-0" (11x17) SCALE: (OR) 3/16" = 1'-0" (24x36)0 1.5'3'5' 3/32" = 1'-0" (11x17) SCALE: (OR) 3/16" = 1'-0" (24x36)0 1.5'3'5'A-3NORTH ELEVATIONEAST ELEVATION 1 1 A-5 GROUND LEVEL ELEV. 0'-0" AGL AGL 0'-0" = 196.1' NAVD 88 TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 90'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS ELEV. 81'-0" AGL NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS, (9) TOTAL, (3) PER SECTOR NEW VERIZON WIRELESS RADIOS, (12) TOTAL, (4) PER SECTOR, (9) LICATED BEHIND ANTENNAS & (3) LOCATED ON NEW RADIO DUAL PIPE RING MOUNT NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 85'-0" AGL NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 20'-0" AGL NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING 2 A-5 GROUND LEVEL ELEV. 0'-0" AGL AGL 0'-0" = 196.1' NAVD 88 TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 90'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS ELEV. 81'-0" AGL NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS, (9) TOTAL, (3) PER SECTOR NEW VERIZON WIRELESS RADIOS, (12) TOTAL, (4) PER SECTOR, (9) LICATED BEHIND ANTENNAS & (3) LOCATED ON NEW RADIO DUAL PIPE RING MOUNT NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 85'-0" AGL NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 20'-0" AGL NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA NEW VERIZON WIRELESS 2'Ø MICROWAVE ANTENNA, (1) TOTAL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAS ELEV. 71'-0" AGL NEW VERIZON WIRELESS 6'Ø MICROWAVE ANTENNA, (1) TOTAL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAS ELEV. 71'-0" AGL NEW VERIZON WIRELESS 6'Ø MICROWAVE ANTENNA, (1) TOTAL NOTE: PAINT ALL NEW VERIZON WIRELESS EQUIPMENT ON TOWER TO MATCH MONOPINE CENTERLINE OF FUTURE PANEL ANTENNAS BY OTHERS ELEV. 61'-0" AGL CENTERLINE OF FUTURE PANEL ANTENNAS BY OTHERS ELEV. 61'-0" AGL SOUTH & WEST ELEVATIONS 123/32" = 1'-0" (11x17) SCALE: (OR) 3/16" = 1'-0" (24x36)0 1.5'3'5' 3/32" = 1'-0" (11x17) SCALE: (OR) 3/16" = 1'-0" (24x36)0 1.5'3'5'A-4WEST ELEVATION SOUTH ELEVATION NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING 3 A-5 4 A-5 NEW VERIZON WIRELESS KNOX BOX NEW VERIZON WIRELESS 12'-0" WIDE CHAIN-LINK ACCESS GATE GROUND LEVEL ELEV. 0'-0" AGL AGL 0'-0" = 196.1' NAVD 88 TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 90'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS ELEV. 81'-0" AGL NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS, (9) TOTAL, (3) PER SECTOR NEW VERIZON WIRELESS RADIOS, (12) TOTAL, (4) PER SECTOR, (9) LICATED BEHIND ANTENNAS & (3) LOCATED ON NEW RADIO DUAL PIPE RING MOUNT NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 85'-0" AGL NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 20'-0" AGL NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA GROUND LEVEL ELEV. 0'-0" AGL AGL 0'-0" = 196.1' NAVD 88 TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 90'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS ELEV. 81'-0" AGL NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS, (9) TOTAL, (3) PER SECTOR NEW VERIZON WIRELESS RADIOS, (12) TOTAL, (4) PER SECTOR, (9) LICATED BEHIND ANTENNAS & (3) LOCATED ON NEW RADIO DUAL PIPE RING MOUNT NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 85'-0" AGL NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES ELEV. 20'-0" AGL NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE NOTE: PAINT ALL NEW VERIZON WIRELESS EQUIPMENT ON TOWER TO MATCH MONOPINE NEW VERIZON WIRELESS 2'Ø MICROWAVE ANTENNA, (1) TOTAL NEW VERIZON WIRELESS 6'Ø MICROWAVE ANTENNA, (1) TOTAL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAS ELEV. 71'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAS ELEV. 71'-0" AGL CENTERLINE OF FUTURE PANEL ANTENNAS BY OTHERS ELEV. 61'-0" AGL CENTERLINE OF FUTURE PANEL ANTENNAS BY OTHERS ELEV. 61'-0" AGL GROUND LEVEL ELEV. 0'-0" AGL 3/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3'A-5SOUTH EQUIPMENT ELEVATION WEST EQUIPMENT ELEVATION 23/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3' EQUIPMENT ELEVATIONS A-5133/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3'NORTH EQUIPMENT ELEVATION 43/8" = 1'-0" (24x36) (OR) SCALE: 3/16" = 1'-0" (11x17) 0 1'2'3'EAST EQUIPMENT ELEVATION GROUND LEVEL ELEV. 0'-0" AGL GROUND LEVEL ELEV. 0'-0" AGL GROUND LEVEL ELEV. 0'-0" AGL AGL 0'-0" = 196.1' NAVD 88 AGL 0'-0" = 196.1' NAVD 88AGL 0'-0" = 196.1' NAVD 88 AGL 0'-0" = 196.1' NAVD 88 TELCO BOX INTERSECT ELEC. METER NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS GPS ANTENNA, (1) TOTAL NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL NEW VERIZON WIRELESS 90'-0" HIGH MONOPINE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS ICE-BRIDGE NEW VERIZON WIRELESS GPS ANTENNA, (1) TOTAL NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 15'-0" X 8'-0" CONCRETE PAD NEW VERIZON WIRELESS GPS ANTENNA, (1) TOTAL NEW VERIZON WIRELESS RAYCAPS, (2) TOTAL, (1) LOCATED AT TOWER, (1) LOCATED AT EQUIPMENT AREA NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 15'-0" X 8'-0" CONCRETE PAD NEW VERIZON WIRELESS HYBRID CABLES, (2) TOTAL NEW VERIZON WIRELESS ICE-BRIDGE NEW VERIZON WIRELESS SERVICE LIGHTS W/6-HOUR TIMER, (4) TOTAL NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING NEW VERIZON WIRELESS ELECTRICAL METER, TELCO BOX & INTERSECT CABINET W/GENERATOR RECEPTACLE ON NEW H-FRAME NEW PORTABLE FIRE EXTINGUISHER (CLASS 4A-60BC) TELCO RBOX POWER/ MISC CAB. BATTERY/ CAB. NEW VERIZON WIRELESS ELECTRICAL METER, TELCO BOX & INTERSECT CABINET W/GENERATOR RECEPTACLE ON NEW H-FRAME NEW VERIZON WIRELESS SERVICE LIGHTS W/6-HOUR TIMER, (4) TOTAL NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE (PARTIALLY SHOWN FOR CLARITY) NEW VERIZON WIRELESS SERVICE LIGHTS W/6-HOUR TIMER, (4) TOTAL NEW VERIZON WIRELESS ELECTRICAL METER, TELCO BOX & INTERSECT CABINET W/GENERATOR RECEPTACLE ON NEW H-FRAME NEW VERIZON WIRELESS 8'-0" HIGH CHAIN-LINK FENCE (PARTIALLY SHOWN FOR CLARITY) FUTURE MISC. CAB. FUTURE MISC. CAB. BATTERY/ CAB. NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 15'-0" X 8'-0" CONCRETE PAD STANDBY 30KW AC GENERATOR NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLON DIESEL TANK (UL142) ON NEW 5'-0" X 10'-0" CONCRETE PAD STANDBY 30KW AC GENERATOR STANDBY 30KW AC GENERATOR NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLON DIESEL TANK (UL142) ON NEW 5'-0" X 10'-0" CONCRETE PAD NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLON DIESEL TANK (UL142) ON NEW 5'-0" X 10'-0" CONCRETE PAD NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 15'-0" X 8'-0" CONCRETE PAD N.T.S. SCALE E-11 M G2P TO MISC. CABINET GG 150A 2"C-3#1/0, 1#6 GROUND, COPPER, THHN/THWN-2 CKT 22 EXISTING VERIZON WIRELESS MISC. CABINET EXISTING 48V DC POWER PLANT CKTS (1,3) (5,7) (6,8) (9,11) (13,15) (17,19) (21,23) (25,27) & (29) CKT 10 &12 NTS SCALE: NTS SCALE:2 1-LINE DIAGRAM, PANEL SCHEDULE & UTILITY NOTES 1-LINE DIAGRAM WP / J BOX SERVICE LIGHTS (TYP. OF 4) 1"C - 2#12, 1#12 GROUND COPPER, THHN/THWN-2 6-HR WIND UP TIMER SWITCH 1"C - 2#12, 1#12 GROUND, COPPER, THHN/THWN-2 4 (3/4" C - 6# 10, 1# 10 GROUND COPPER, THHN/ THWN-2) & 3/4" C- 2#12, 1#12 GROUND, COPPER THHN / THWN-2 1"C - 2#12, 1#12 GROUND COPPER, THHN/THWN-2 (STANDBY GENERATOR BATTERY CHARGER) 1"C - 2#12, 1#12 GROUND COPPER, THHN/THWN-2 (STANDBY GENERATOR BLOCK HEATER) NEW VERIZON WIRELESS 30KW GENERAC STANDBY GENERATOR W/210 GALLONS DIESEL TANK UL142 ANCHORED TO CONCRETE SLAB 1"C FOR ALARM WIRING TO MISC. CABINET #4 AWG PER GENERAC REQUIREMENTS MAIN GROUND RING SYSTEM 2"C - 3 #4/0, 1#6 GROUND, COPPER THHN/THWN-2 (UP TO 150 FT) PANEL SCHEDULE KEY NOTES: 2 3 200A/2P ILC 120/240 V, 1 PHASE, 3 WIRE, MAIN PANEL BY INTERSECT, INC- NEMA 3R ENCLOSURE INTERSECT LOAD CENTETR W/ 30 CIRCUIT POSITIONSNEW 3/4"-1#6 GROUND, COPPER BONDED TO MAIN GROUND SYSTEM 2 NEW INTEGRATED LOAD CENTER (PANEL A) INTERSECT INC MANUFACTURE (AA 300-3R SERIES MODEL AA 3003R - 458 - 6M - 3S) W/200AMP/2POLE, ATS, 120/208 V, 1-PHASE, 3WIRE, 42KAIC W/30 POSITIONS PROVIDED BY VERIZON WIRELESS. NEW AUTOMATIC TRANSFER SWITCH GENERAC ASCO SERIES 300L, 200 AMP, 120/208V, 1PHASE, 3 WIRE, 2 POLE, 42 KAIC ATS 3 CKT 18 CKT 20 LOAD PHASE 1 ADDITIONAL 25% CONTINUOUS LOAD = DESCRIPTION C 16,000 8 B NO.PHASE 1 6 4 2 PHASE 2 CB DESCRIPTION 15,600 TOTAL LOAD (PHASE 1 & 2) = LOAD PHASE 2 48VDC POWER PLANT RECTIFIER #1 3 16 1 14 5 18 7 9 11 31,600 TOTAL LOAD 32,000 TOTAL AMPS 134 AMPS= = CKT NO.CKT 13 15 19 20 21 22 23 24 25 26 60A 2P 27 28 29 30 17 20A 2P 2P 20A 2P 2P 2P 2P 2P 2P 20A 15A 1P SURGE SUPPRESSOR- - 2,400 - - - - - - - - - - -48VDC POWER PLANT INTERIOR OUTLET 48VDC POWER PLANT RECTIFIER #2 48VDC POWER PLANT RECTIFIER #3 48VDC POWER PLANT RECTIFIER #4 48VDC POWER PLANT RECTIFIER #5 48VDC POWER PLANT RECTIFIER #6 48VDC POWER PLANT RECTIFIER #7 48VDC POWER PLANT RECTIFIER #8 SPACE SPACE SPACE SPACE - - - - 2,400 - 400 SERVICE/ TECH LIGHTS MISC. CABINET RECEPTACLE #11P 20A 1P 1,200 3,600 3,600 2,600 2,900 20A 20A 20A 20A 20A 20A 1,200 1,200 2,000 1,800 1,200 - - 20AMISC. CABINET RECEPTACLE #21P MAIN ELECTRICAL PANEL 120/240 V, 1 PHASE, 3 WIRE, 200 AMP BUS 200 AMP/2P, ATS MAIN BREAKER MANUFACTURED BY INTERSECT, INC MODEL AA3003R SERIES 10 12 STDBY GENERATOR BATT. CHARGER STDBY GENERATOR BLOCK HEATER20A 1P1,800 -NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE: ISSUE STATUS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON WIRELESS ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 945984338 SHORTHORN DR.CHICO, CA 95973PSL# 491608KEEFER03/19/2020 FA090% ZONING DESCRIPTIONDATE BYREV. TM SAN DIEGO, CA 92122 619.736.3766 5015 SHOREHAM PLACE, STE. 150 www.sacw.com 03/27/2020 FA1100% ZONING 05/22/2020 FA2100% ZONING 08/20/2020 FA3REVISED 100% ZONING 20AMISC. CABINET RECEPTACLE #11P 20AMISC. CABINET RECEPTACLE #21P20A 1P EXISTING VERIZON WIRELESS MISC. CABINET 1"C - 2#12, 1#12 GROUND, COPPER, THHN/THWN-2 CKT 14 &16 EXISTING TRANSFORMER T-3080 (NEW VERIZON WIRELESS POWER P.O.C.) G N MMELECTRICAL SERVICE TERMINATION UNDERGROUND PULL BOX, NEMA 3R. UNISTRUT MOUNTED. 400A, 1 PHASE, 3 WIRE, 120/240 SCI = 18,000 AMPS CAT #R9000EE G N 6"X6"X36" NEMA 3R SCREW COVER WIREWAY NEW 3/4" C W/ #2 GROUND COPPER BONDED TO 5/8" X 8' LONG COPPER CLAD STEEL GROUND ROD NEW 3/4" C W/ #2 GROUND COPPER BONDED TO 5/8" X 8' LONG COPPERCLAD STEEL GROUND ROD CAT # 224MTBP 200A FUSIBLE PULL-OUT #2 GROUND COPPER (2) ELECTRICAL METERING 200 AMPERE, 120/240 VOLT, 1 PHASE, 3 WIRE NEW (1) 2" CONDUIT BY GC AND CONDUCTORS BY P.P. (± 520 FT) NEW 17"X30" HAND HOLE AS NEEDED NEW PG&E/ VERIZON WIRELESS ELECTRICAL METER 120/240 V, 1 PHASE, 3 WIRE, 100 AMP, 28 KVA, NEMA 3R ENCLOSURE. 1 1 UTILITY GENERAL NOTES: 1.ALL NEW GROUNDINGS FOR ELECTRICAL ROUTE METER MUST BE DONE PER CEC, NEC & LOCAL BUILDING & SAFETY REQUIREMENTS. 2.ALL NEW CONDUIT FROM ELECTRICAL ROUTE METER TO THE SITE MUST BE RGS CONDUITS. INSTALL WEATHERPROOF PULL BOXES AS REQD. PER CEC, NEC & LOCAL BLDG. & SAFETY REQUIREMENTS & MUST HAVE TRAFFIC COVERS. 3.ALL NEW PULL BOXES MUST BE HOT-DIPPED GALVANIZED AND WEATHERPROOF 4.ALL NEW WIRE SPLICES PULL BOXES DONE PER CEC & NEC. 5.FIELD VERIFY EXACT ELECTRICAL CONDUIT ROUTE. 6.VERIZON WIRELESS NEW METER/MAIN NEED TO BE LABELED & ALL CLEARANCE FOR ELECTRICAL EQUIPMENT BY CEC & NEC. 7.NEW GROUND RODS MAY BE USED FOR SITE GROUNDING IF DESIRED RESISTANCE IS ACHIEVED. 8.CONTRACTOR TO INSTALL UTILITY CONDUIT (LATERAL). 9.UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANY AND ARE FOR BID PURPOSES ONLY. 10.CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. NTS SCALE: NTS SCALE:3UTILITY NOTES