HomeMy WebLinkAboutB21-0241 Submittal and plans 4009-9602 CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0375 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Models 4009-9601, 4009-9601 BA, 4009-9602 and 4009-9602 BA IDNAC repeaters. Model 4009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 120V/240V INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an accessory for use with listee’s separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. 04-23-13 gt July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 4009-9602 DATASHEET.pdf4009 IDNAC Repeater; Power and Distance Extender 4009 IDNAC Repeater; Power and Distance Extender * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0553 and 7300-2269:0558 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Features 4009 IDNAC Repeaters provide enhanced power delivery to TrueAlert/TrueAlert ES addressable notification appliances controlled by IDNAC SLCs: • Output voltage in alarm is maintained by an efficient switching regulator at 29 VDC during both AC input and battery backup conditions allowing strobes to operate at lower current • With lower current strobes and regulated output voltage, wiring distance can be extended 2 to 3 times that of conventional notification, appliance loading can be increased, or smaller wire gauge can be used, all resulting in installation savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions 4009 IDNAC Repeaters receive an IDNAC SLC input and provide a repeated 3 A SLC output to extend SLC distance and power: • Appliance control and address limit remains with the host IDNAC control panel. Repeater status is communicated to the control panel for system diagnostics and also locally indicated • Repeater output extends supervisory capacity by up to 139 additional unit loads or 3 A • Input SLC connection can be Class B or Class A • Repeater output can be a Class A loop or a Class B output with internal connections for up to four (4) T-tapped output branches (Class A output requires A009-9814 Class A Adapter) • Operation requires one IDNAC SLC address; Repeaters can be connected as one in series, or up to five (5) in parallel • AC power input is 120 VAC or 220-240 VAC, 50/60 Hz, auto-select • An on-board battery charger is provided with low AC battery disconnect selectable per Repeater (required for ULC listed applications) • Operation is compatible with TrueAlert ES and TrueAlert addressable notification appliances and accessories • Available with platinum or red cabinet • Listed to UL 864 and ULC S527 Multiple wiring options are available: • Wiring options include Class B multiple branch (up to 4) output, Class A loop extension, and Class A riser to Class B branches or a Class A loop output • When the Repeater is part of a Class A loop from the IDNAC SLC source panel, up to twice the distance for the loop is available; (Class A loop repeating requires A009-9814 Class A Adapter) Figure 1: 4009 IDNAC Repeater Extends Distance and Current of IDNAC SLC Class A Adapter A009-9814: • Required when extending a Class A loop or to provide a Class A local loop SLC output • Operation provides short circuit isolation between input and output terminals for improved IDNAC SLC survivability Built-in battery Charger • Power supply charges up to 12.7 Ah batteries for in cabinet mounting and up to 25 Ah batteries with model A009-9801 external battery cabinet Available auxiliary output: • A 200 mA, 29 VDC constant auxiliary output is available; operation is maintained during battery backup UL, ULC Approved and CSFM Listed* TrueAlert Addressable Notification AC4009-0004 Rev. 6 01/2020 Introduction Repeating IDNAC SLCs Autocall fire alarm control panels with IDNAC SLC outputs provide individual address and control of TrueAlert and TrueAlert ES addressable notification appliances. When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC, use of 4009 IDNAC Repeaters extends the IDNAC SLC with an additional 3 A of SLC current and up to 139 unit loads of additional supervisory capacity. With IDNAC SLCs, a constant 29 VDC source voltage is maintained in alarm, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. Description Three wiring configurations Three wiring configurations are available to provide a variety of system solutions: Class B branch extension, Class A loop extension, and Class A riser to Class B branch extension or Class A loop output. Class B branch input wiring Class B branch input wiring allows T-tapped connections to up to five (5) parallel connected 4009 IDNAC Repeaters. Each Repeater has on-board output terminal connections for up to four (4) output branch circuits, and additional branch circuits can be externally T-tapped as required. (Refer to Wiring Reference, Class B Input with Class B Branch Circuit Outputs for additional details.) Class A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be doubled. The Repeater communicates and repeats bi-directionally allowing Class A loop operation to be maintained in the event of an open circuit. This wiring connection requires use of the A009-9814 Class A adapter. (Refer to Wiring Reference, Class A Loop Extension for additional details.) Class A Riser to Class B Branches or Class A Loops For applications requiring a combination of wiring types, a Class A riser can drive up to five (5) 4009 IDNAC Repeaters with each Repeater capable of driving either single or multiple Class B branch output(s) or a Class A loop output. In this wiring application, the Repeater does not repeat in the Class A riser loop, it is connected as an appliance with Class A in/out wiring. To create a Class A loop output, the Repeater must be equipped with a A009-9814 Class A Adapter. (Refer to Wiring Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs for additional details.) Product Selection Table 1: IDNAC Repeater Selection Model Cabinet Color Description A009-9601(BA) Platinum A009-9602(BA) Red 4009 IDNAC Repeater with cabinet; provides a single 3 A IDNAC SLC output, 200 mA auxiliary power output, and battery charger; 120/240 VAC, 50/60 Hz input, auto-select Table 2: Aftermarket Accessories (installed on-site, select per system requirements) Model Description A009-9814 Class A Adapter Module, mounts on repeater controller board; required for Class A output A2975-9813 Platinum semi-flush box trim A2975-9812 Red semi-flush box trim 1 7/16" (37 mm) wide, four corners and trim pieces for top, bottom, and sides; (will need to be cut to fit 4009 IDNAC Repeater cabinet) Table 3: External Accessories (select per system requirements) Model Description Comments A4905-9929 Remote TrueAlert Communications Isolator Refer to data sheet AC4905-0001 for details A009-9801 External Battery Cabinet for 25 Ah batteries 16 ¼" W x 13 ½" H x 5 ¾" D (413 mm x 343 mm x 146 mm); refer to data sheet AC2081-0006 for details Table 4: Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation) Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires A009-9801 External Battery Cabinet Page 2 AC4009-0004 Rev. 6 01/2020 4009 IDNAC Repeater; Power and Distance Extender Wiring Reference, Class B Input with Class B Branch Circuit Outputs Figure 2: Wiring Reference Page 3 AC4009-0004 Rev. 6 01/2020 4009 IDNAC Repeater; Power and Distance Extender Wiring Reference, Class A Loop Extension Figure 3: Wiring Reference Page 4 AC4009-0004 Rev. 6 01/2020 4009 IDNAC Repeater; Power and Distance Extender Wiring Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs Figure 4: Wiring Reference 4009 IDNAC Repeater Mounting and Module Placement Reference Figure 5: Placement Reference Page 5 AC4009-0004 Rev. 6 01/2020 4009 IDNAC Repeater; Power and Distance Extender 4009 IDNAC Repeater Specifications Table 5: Input Ratings Specification Rating Voltage Range 120 VAC, 50/60 Hz, or 220/230/240 VAC, 50/60 Hz, +10%, -15%, auto-select 120 VAC Current 2.5 A 220/230/240 VAC Current 1.25 A 17 VDC minimumI DNAC Input Ratings 1 address, 4 unit loads Table 6: 24 VDC Requirements for Battery Calculations Specification Panel IDNAC Appliances Auxiliary Load Standby Currents 70 mA 0.8 mA each Output current (voltage is from battery) Alarm Currents 96 mA 4.5 A maximum with 3 A IDNAC SLC load and 200 mA Auxiliary output load (actual alarm current depends on connected and activated appliances and devices) 1.37 x output current (voltage converter is on when in Alarm) Table 7: Output Ratings Specification Rating IDNAC SLC Output 3 A maximum @ 29 VDC for Special Application appliances Compatible Special Application Appliances Autocall TrueAlert ES and TrueAlert addressable notification appliances; contact your Autocall product representative for compatible appliances Each repeater uses four unit loads on the IDNAC channel it receives power from and supports up to 139 additional unit loads. Most appliances are 1 unit load; Multi-Tone appliances are 2 unit loads; Repeaters and Isolators are 4 unit loads. Refer to individual appliance and device specifications for unit load requirements and rated SLC loading specifications. IDNAC Repeater Loading and SLC Address Usage Each repeater uses one IDNAC SLC device address - the IDNAC Repeater does not increase the IDNAC channel device address capacity. Refer to the Host IDNAC SLC specifications for the device address capacity specifications on the IDNAC channel. Current 200 mA maximum 29 VDC nominal with AC present or when Repeater is on battery standby and in Alarm Auxiliary Output Voltage 24 VDC nominal when on battery standby and not in Alarm Table 8: IDNAC SLC Wiring Specifications (refer to installation instructions for more information) Specification Rating Recommended wire type UTP , unshielded twisted pair Maximum wire length allowed with "T-Taps" for class B wiring 10,000 ft (3048 m) Maximum wire length to any appliance 4000 ft (1219 m) Wiring Connections Terminal blocks for 18 to 12 AWG Table 9: Repeater Status Indicators Specification Rating Green AC Power LED On with AC present, off during brownout or no AC condition Red Communications LED (COMM) Blinks when Repeater is communicating with the host control panel Yellow System Status LEDs 4 LEDs provide up to 16 different trouble status indications; an on-board trouble scroll button allows review should multiple troubles occur Table 10: A009-9814 Class A Adapter Module Option (required for Class A loop extension or for Class A output) Specifications Rating 3 A maximum @ 29 VDC for Special Applications appliancesI DNAC SLC Output Voltage Two connections, Port A and Port B, function varies by application (loop extension or local loop), Port A and Port B are isolated from each other Status LEDs Two yellow trouble LED indicators, one for each port Table 11: Environmental and Technical Publications Reference Specification Rating Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Operating Humidity Range Up to 93% RH at 90 °F (32 °C) 4009 IDNAC Repeater 579-1019ACInstallation Instructions Class A Adapter Module 579-1080AC AC4009-0004 Rev. 6 01/2020 © 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 4009 IDNAC Repeater; Power and Distance Extender 4090-9051 CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised IAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP IAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class ”A” ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class “B” ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee’s Installation Instruction Manual for details. NOTE: *Recert. 03-29-2006 jw July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 4090-9051 DATASHEET.pdfIDNet Communicating Devices, Individual Addressable Modules (IAMs) IDNet Communicating Devices, Individual Addressable Modules (IAMs) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0507 and 7300-2269:0567 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Features IDNet addressable communications supply both data and power over a single wire pair to provide** • Supervised Class B monitoring of normally open, dry contacts • Total wiring distance from IAM to supervision resistor(s) of up to 500 ft (152 m) • Monitored connection is compatible with Autocall A2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications • For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Autocall control panels • Model Series 4007ES, 4010ES, and 4100ES fire alarm control panels for IDNet communications Model A4090-9001 • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model A4090-9051 • Encapsulated design for extended exposure to high humidity (LED is not present on this model) • Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring • Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same circuit using one point • Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel • Contact closure status can be tracked • Momentary contact closure conditions can be selected at the panel to be latched or tracked , UL listed to Standard 864 UL listed to Standard 864 Description Individual addressable modules (IAMs) receive both power and communications from a two-wire IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. SKU A4090-9001 A4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. SKU A4090-9051 A4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. Figure 1: A4090-9001 Supervised IAM Figure 2: A4090-9051 Supervised IAM Operation Contact Closure Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status . Current Limited Operation Applications For use with IDNet communications only, these IAMs can provide quadstate sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. UL, ULC, CSFM Listed* Multi-Application Peripherals AC4090-0001 Rev. 13 1/2020 IAM Product Selection Table 1: IAM Product Selection SKU Description A4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals; see applicable options below A4090-9051 Supervised IAM, encapsulated with wire leads Table 2: Optional Trim Plates and Mounting Bracket for Model A4090-9001 SKU Description A4090-9806 For semi-flush mounted box A4090-9807 For surface mounted box Trim plate with LED viewing window, requires A4090-9810 mounting bracket, includes mounting screws; galvanized steel A4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates Table 3: End-of-Line Resistor Harnesses (ordered separately as required) SKU Reference no. Description A4081-9004 733-886 6.8 kΩ, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision A4081-9003 733-896 4.7 kΩ, 1/2 W A4081-9005 733-984 1.8 kΩ, 1/2 W Use for current limited monitoring applications Specifications Table 4: Electrical Specification Rating Power and Communications IDNet, auto selected, 1 address per IAM Input Requirements Normally open, dry contacts A4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2)W ire Connections A4090-9051 Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Installation Instructions 574-331AC for A4090-9001; 579-572AC for A4090-9051 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation Table 5: Wiring Distances Specification Rating 500 ft (152 m) maximum without protectors Distance from IAM to Contacts 400 ft (122 m) maximum with A2081-9044 Overvoltage Protectors 2500 ft (762 m) maximum from fire alarm control panel Wiring Distance Reference per channel, IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Table 6: Mechanical Specification Rating A4090-9001 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) Dimensions A4090-9051 1-9/16" W x 1-9/16" H x 9/16" D (40 mm x 40 mm x 14 mm) Housing Material, A4090-9001 Black thermoplastic Encapsulation Material, A4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Page 2 AC4090-0001 Rev. 13 1/2020 IDNet Communicating Devices, Individual Addressable Modules (IAMs) Mounting Information Figure 3: Mounting Reference, Single Gang Blank Cover Plate Note: Figure 3 shows A4090-9001 IDNet supervised IAM. Figure 4: Optional Trim Plates and Mounting Bracket for Visible LED Note: Figure 4 shows the following: • A4090-9806, Trim plate for semi-flush mounted box • A4090-9807, Trim plate for surface mounted box • A4090-9810, Mounting bracket, ordered separately Page 3 AC4090-0001 Rev. 13 1/2020 IDNet Communicating Devices, Individual Addressable Modules (IAMs) A4090-9051 Mounting Information Figure 5: A4090-9051 Mounting Information Note: Figure 5 shows a A4090-9051 Encapsulated Supervised IAM. AC4090-0001 Rev. 13 1/2020 © 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). IDNet Communicating Devices, Individual Addressable Modules (IAMs) 4098-9714 CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Models 4098-9714, -9774, -9714TSP, -9714TTP, -9754 -9754TSP, -9754TTP; GSA4098-9714, and -9754 analog photoelectric type smoke detectors. Models 4098-9754, -9779, -9754TSP, -9754TTP; GSA4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (135°F fixed temperature and 120°F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee’s separately listed compatible fire alarm control units. Units are intended for use with smoke detector bases Models 4098-9789, -9789TSP, -9789TTP, -9791, -9791TSP, -9775, -9776, -9777, -9791TTP, -9792, -9792TSP, 9792TTP, -9793, 9793TSP, -9793TTP ; GSA4098-9792, and -9793 (CSFM Listing No. 7300-0026:0217); *4098--9794, -9794TSP,-9794TTP (CSFM Listing No. 7300-0026:0500). Models 4098-9714, -9714TSP and -9714TTP are listed for use with Models 4098-9750,-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:0220) and Models 4098-9755, -9755TSP and -9755TTP duct detector units (CSFM Listing No. 3240-0026:0241). Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. Refer to listee’s Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-01-18 gt July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 49AV CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0371 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Model 49AV Horn/strobe with suffixes WRFO, WRFO-BA, WWFO-BA,and APPLW-O. Model 49AVC Horn/strobe with suffixes WRFIRE-O, WWFIRE-O, WRALT-O, WWALT-O, WRFEU-O, WWFEU-O, WRBLNG-O, WWBLNG-O, WRS-O, and WWS-O. Model 49VO Strobe with suffixes WRFO, WRFO-BA, WWFO-BA, *WRSO, WRSO-BA, and APPLW-O. Model 49VOC Strobe with suffixes WRFIRE-O, WWFIRE-O, WRALT-O, WWALT-O, WRFEU-O, WWFEU-O, WRBLNG-O, WWBLNG-O, WRS-O, and WWS-O.. Refer to listee's data sheet for detailed product description and operational consideration. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired. Refer to listee’s Installation Instruction Manual for details. *Rev 09-25-13 gt July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 49AV DATASHEET.pdfAC49WP-0002_miramo.xml Wall Mount Weatherproof Notification Appliances Visible Only (VO) and Audible/Visible (A/V) * Additional listings may be applicable; contact your local product supplier for the latest status. ULC Listed TrueAlert ES Addressable Notification Appliances A49WP-0002 Rev. 4 6/2019 Features Individually addressed and controlled multi-candela TrueAlert ES weatherproof notification appliances for extended temperature and humidity range provide: • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 20, 30, or 75 cd • Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup • Wiring supervision to each appliance allowing “T-tapped” connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel • TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 3) • Magnet Test diagnostics to assist checkout and testing of appliances and wiring • Electrical test point access without removing cover LED Indicator and Magnet Test feature: • Appliance LED can be selected to display each polling cycle to indicate appliance supervision • When the controller is in diagnostic mode, the Magnet Test pulses the LED to indicate appliance address and can be set to also briefly flash the strobe and sound the A/V horn Mechanical design features include: • Rugged, high impact, flame retardant thermoplastic housing with clear lens • Standard models are red and available with FIRE or FEU lettering; configured models are available with additional lettering of FEU/FIRE, ALERT, and blank, and in white with each lettering • Mounting is to matching weatherproof boxes (required), ordered separately • Separate covers are available to change application type on-site or for replacement • In/out wiring terminals for 18 AWG to 12 AWG • Enclosure is rated NEMA 3R • Convenient wiring terminal access at front of housing Agency listings reference: • Strobe operation is listed to ULC-S526 • Horn operation is listed to ULC-S525 • Refer to data sheet A49WP-0001 for UL listed models Figure 1: Weatherproof A/V (top) and Strobe (bottom), side view of A/V on Weatherproof Mounting Boxes (right) For A/V Models with horn: • Harmonically rich output sound for either coded or steady operation • Horns sound as Temporal Code 3, March Time pattern, continuous; or Temporal Code 4, controlled separately from visible appliances on the same two-wire circuit • Selectable March Time rates of 20, 60, or 120 beats per minute • Output is “high” or “low” (~5 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance Description TrueAlert ES weatherproof addressable appliances provide visible and audible/visible notification for indoor and outdoor, extended temperature and extended humidity applications. They are individually addressed and receive power, supervision, and control signals from a Autocall fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 4.) Strobe application reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Page 2 A49WP-0002 Rev. 4 6/2019 Wall Mount Weatherproof Notification Appliances Visible Only (VO) and Audible/Visible (A/V) TrueAlert ES operation advantage TrueAlert ES addressable appliances on IDNAC SLCs provide separate visible and audible notification using a single two-wire circuit that also confirms connection to the individual notification appliance’s electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be “T” tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of Self-Test and Magnet Test features improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. TrueAlert ES diagnostics Test Features. When IDNAC SLCs are in diagnostic mode, Self-Test and Magnet Test features provide individual appliance testing. With the Self-Test feature, appliance operation can be confirmed without leaving the control panel. Additionally, each appliance’s LED can be selected to pulse when it receives a supervision poll during normal operation. Self-Test Details. Selecting Self-Test Mode from the control panel allows on-board sensors, depending on the device type, to detect its own strobe and/ or horn output and then report their status to the control panel. Operation is by selected VNAC appliance groups and is either automatic (all briefly simultaneously activated) or individually activated by applying a magnet. (Refer to control panel data sheet for more Self-Test information, see list on page 4.) Silent Appliance Magnet Test. In this test mode, in response to application of a magnet, the appliance LED pulses sequentially to conveniently indicate the appliance’s address. Operational Appliance Magnet Test. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash and the A/V horn will briefly sound to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Autocall representative for additional information. TrueAlert addressable wiring isolator Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Product selection Table 1: ULC listed TrueAlert ES addressable weatherproof notification appliances Type Model Cover color/lettering Description ULC intensity ratings Horn/Strobe (A/V) A49AV-APPLW-CO order cover separately ULC listed weatherproof TrueAlert ES addressable appliance; requires weatherproof box below 20, 30, or 75 cd Table 2: Separate Covers (Required when ordering A49AV-APPLW-CO) Lettering Red VO cover models Red AV cover models White VO cover models White AV cover models FIRE A49VOC-WRFIRE-O A49AVC-WRFIRE-O A49VOC-WWFIRE-O A49AVC-WWFIRE-O ALERT A49VOC-WRALT-O A49AVC-WRALT-O A49VOC-WWALT-O A49AVC-WWALT-O FEU A49VOC-WRFEU-O A49AVC-WRFEU-O A49VOC-WWFEU-O A49AVC-WWFEU-O FEU/FIRE A49VOC-WRBLNG-O A49AVC-WRBLNG-O A49VOC-WWBLNG-O A49AVC-WWBLNG-O Blank A49VOC-WRS-O A49AVC-WRS-O A49VOC-WWS-O A49AVC-WWS-O Table 3: Wall mount weatherproof boxes (required) Model Color Description Dimensions A49WPBB-AVVOWR Red A49WPBB-AVVOWW White Surface Mount Weatherproof Mounting Box (required) 5 1/2” H x 6 1/8” W x 1 5/8” D (140 mm x 156 mm x 41 mm) Page 3 A49WP-0002 Rev. 4 6/2019 Wall Mount Weatherproof Notification Appliances Visible Only (VO) and Audible/Visible (A/V) TrueAlert device reports reference Figure 2: Report example Installation references Figure 3: Weatherproof appliance installation reference *Red: A49WPBB-AVVOWR; white: A49WPBB-AVVOWW Figure 4: Dimension and mounting height reference A49WP-0002 Rev. 4 6/2019 © 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Wall Mount Weatherproof Notification Appliances Visible Only (VO) and Audible/Visible (A/V) Table 4: IDNAC SLC controller compatibility reference Compatible controllers Controller output IDNAC SLC output voltage Appliance voltage design reference 4100ES with EPS+ or EPS Power Supply 4009 IDNAC Repeater 4007ES with IDNAC Notification 4010ES with ESS Enhanced System Supply IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) Specifications Table 5: General specifications Specification Rating Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads Temperature Range -40°F to 150°F (-40°C to 66°C); 20, 30, or 75 cd setting Humidity Range up to 98%, at 104°F (40°C) UTP , unshielded twisted pair recommended Maximum wire length allowed with “T-Taps” for Class B wiring per SLC = 10,000 ft (3048 m) IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) Maximum wire length to any appliance = 4000 ft (1219 m) Wiring Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two wires per terminal for in/out wiring Table 6: A/V horn output ratings @ 10 ft (3 m) @ 23 VDC Sound type Anechoic chamber, ULC 525 test Steady/high 87.4 dB Steady/low 81.0 dB* Coded/high 87.2 dB Coded/low 80.6 dB* Note: *Settings with ratings below 85 dB should not be used for Public Notification. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a “fast” setting. Table 7: 23 VDC current ratings Model 20 cd 30 cd 75 cd A/V Model A49AV-APPLW-CO, horn on continuous, high setting 161 mA 165 mA 181 mA Level Decrease Horizontal Angle Vertical Angle +50° (to right) +55° (above axis) -3 dB -40° (to left) -70° (below axis) +85° (to right) +60° (above axis) A/V Sound Dispersion per ULC-S525 Anechoic testing performed at 3 m (10 ft); referenced to on-axis = 0° -6 dB 85° (to left) -90° (below axis) 49AV-APPLC DATASHEET.pdfAudible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/ Strobe,Model Series A49AV * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7125-2269:0520, 7300-2269:0553 and 7125-0026:0380 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Autocall product supplier for the latest status. Description Ceiling Mount Addressable Visible (A/V) Notification Appliances are individually addressed audible/visible notification appliances that receive power, supervision, and control signals from an Autocall fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. (See TrueAlert ES A/V LEGACY Compatibility Reference .) Features Individually addressed and controlled multi-candela TrueAlert ES A/V (audible/visible) notification appliances provide: • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75 or 110cd on the AV model, or 110, 135 or 185 cd on the AVH model • Advanced addressable notification controlled by IDNAC SLCs. • IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current • Wiring supervision to each appliance allowing “T-tapped” connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel • TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample in TrueAlert Device Reports Reference) • Magnet Test diagnostics to assist checkout and testing of appliances and wiring • Electrical test point access by removing the cover • Compatibility with ADA requirements; (refer to important installation information in Installation Reference) • Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see TrueAlert ES A/V LEGACY Compatibility Reference ) • Strobe operation is listed to UL Standard 1971 and ULC Standard S526; Horn operation is listed to UL Standard 464 and ULC Standard S525 LED Indicator and Magnet Test feature: • Appliance LED can be selected to display each polling cycle to indicate appliance supervision • When the controller is in diagnostic mode, the Magnet Test pulses the LED to indicate appliance address and can be set to also briefly flash the strobe and sound the horn Mechanical design features • Rugged, high impact, flame retardant thermoplastic housing in red with white letters or white with red letters, with clear lens, available with FIRE, FEU, ALERT, FEU/FIRE, or blank lettering • Separate covers are available to change application type onsite or for replacement • You can use a back box to mount the appliance assembly to the wall. Mount to a 4-inch (10.16 cm) square electrical box • Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions • In/out wiring terminals for 18 AWG to 12 AWG • Optional red wire guards (see Product Selection) Audible notification appliance (horn): • Harmonically rich output sound for either coded or steady operation • Horns sound as Temporal Code 3, March Time pattern, continuous; or Temporal Code 4, controlled separately from visible appliances on the same two-wire circuit • Selectable March Time rates of 20, 60, or 120 beats per minute • Output is “high” or “low” (~5 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance Figure 1: TrueAlert ES Addressable A/V Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, and local codes. TrueAlert ES Operation Advantage TrueAlert ES addressable appliances on IDNAC SLCs provide separate visible and audible notification using a single twowire circuit that also confirms connection to the individual notification appliance’s electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be “T” tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of Self-Test and Magnet Test features improve installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. UL, ULC, CSFM Listed* TrueAlert ES Addressable Notification Appliances AC49AVC-0001 Rev. 8 01/2020 TrueAlert ES Diagnostics Test Features When IDNAC SLCs are in diagnostic mode, Self-Test and Magnet Test features provide individual appliance testing. With the Self-Test feature, appliance operation can be confirmed without leaving the control panel. Additionally, each appliance’s LED can be selected to pulse when it receives a supervision poll during normal operation. Self-Test Details Selecting Self-Test Mode from the control panel allows on-board sensors, depending on the device type, to detect its own strobe and/or horn output and then report their status to the control panel. Operation is by selected VNAC appliance groups and is either automatic (all briefly simultaneously activated) or individually activated by applying a magnet. (Refer to control panel data sheet for more Self-Test information, see list in Table 10.) Silent Appliance Magnet Test In this test mode, in response to application of a magnet, the appliance LED pulses sequentially to conveniently indicate the appliance’s address. Operational Appliance Magnet Test. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash and the horn will briefly sound to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Autocall representative for additional information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (See data sheet AC4905-0001.) Installation Reference TrueAlert Device Reports Reference Page 2 AC49AVC-0001 Rev. 8 01/2020 Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV Product Selection Ceiling Mount Addressable Audible/Visible (A/V) Appliances TrueAlert ES Addressable A/V appliance dimensions with cover: 8 ⅛ ” H x 7 ⅛” W x 3” D ( 206 mm x 180 mm x 76 mm) Table 1: Ceiling Mount Addressable Audible-Visual Only A/V Appliances SKU* Lens color Description Installation Instructions A49AV-APPLC A49AV-APPLC-BA A49AVH-APPLC A49AVH-APPLC-BA Clear A49AVH-APPLCA-BA Amber A49AVH-APPLCB-BA Blue 579-1242AC (Pending) Green (Pending) Red AV appliance only. Select cover separately. Table 2: Back boxes SKU Color A49WPBB-SVCR Red A49WPBB-SVCW White Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. Table 3: Separate Covers (Required when ordering model 49AV-APPLC(-BA)) SKU* Color Wording A49AVC-CRFIRE Red A49AVC-CWFIRE White FIRE A49AVC-CRALT Red A49AVC-CWALT White ALERT A49AVC-CRBAA Red A49AVC-CWBAA White إﻧﺬار /ALERT A49AVC-CRS Red Autocall logo only A49AVC-CK Black Blank A49AVC-CRFEU Red A49AVC-CWFEU White FEU A49AVC-CRBAF Red A49AVC-CWBAF White ﺣﺮﻳﻖ/FIRE A49AVC-CRBF Red A49AVC-CWBF White FEU/FIRE A49AVC-CWS White Autocall logo only A49AVC-CWCALT White 火警/FIRE Table 4: Wire Guards and Wire Guard Back Boxes SKU Description A49WG-SVWCR AV Ceiling Mount Red Wire Guard A49WGBB-SVCR-O AV Ceiling Mount Red Wire Guard Back Box Page 3 AC49AVC-0001 Rev. 8 01/2020 Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV TrueAlert ES A/V Specifications Table 5: Electrical Ratings Specification Rating Typical Operating Voltage Range 23 VDC to 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) IDNAC SLC Loading Maximum of 127 addresses per SLC Table 6: Sound Output Ratings @ 10 ft (3 m) (with IDNAC SLCs) Sound Type/Setting Voltage Steady/High Steady/Low Coded/High Coded/Low 23 89.0 dBA 83 dBA 85 dBA 80 dBAR everberant Chamber, UL 464 Test 31 91 dBA 85.5 dBA 87 dBA 82 dBA 23 97 dBA 92.5 dBA 97 dBA 92.5 dBAA nechoic Chamber, ULC 525 Test 31 99 dBA 95 dBA 99 dBA 95 dBA Table 7: Maximum RMS operating current 49AV Visible 49AVH Visible CandelaCandela 23-30 VDC Current 17-31 VDC Current CD amber dome CD blue dome CD clear dome Current 15 67 mA 84 mA - - - 30 92 mA 119 mA 95 75 110 300 mA 75 159 mA 214 mA 110 95 135 330 mA 110 215 mA 279 mA 135 110 185 391 mA UL rated only AO: 17 V or 23 V rating 18 mA Table 8: General Specifications Specifications Ratings Sound Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Temperature Range 32° to 120° F (0° to 49° C) Humidity Range 10% to 93%, non-condensing @ 104° F (40° C) Connections Terminal blocks on mounting plate for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring UTP , unshielded twisted pair recommended Maximum wire length allowed with “T-Taps” for Class B wiring per SLC = 10,000 ft (3048 m) IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) Maximum wire length to any appliance = 4000 ft (1219 m) Note: UL 464 test coded values are typical of the output measured with a Temporal or a March Time pattern and with a sound level meter reading on a “fast” setting. Under the same test conditions, coded horn output “peak” sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. IDNAC SLC Controller Compatibility Reference Table 9: Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 4007ES with IDNAC Notification AC4007-0002 4010ES with ESS Enhanced System Supply AC4010-0011 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) TrueAlert ES A/V LEGACY Compatibility Reference Table 10: Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum 4100ES with TrueAlert Power Supply AC4100-0031 4009 TPS, Remote TrueAlert Power Supply* AC4100-0037 TrueAlert Addressable Controller (4009T)* AC4009-0003 TrueAlert Addressable SLC 15, 30, 75, and 110 cd Continuous, Temporal Code 3, and March Time of 60 or 120 bpm 17 VDC Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Page 4 AC49AVC-0001 Rev. 8 01/2020 Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV Table 10: Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum Voltage Range 17 VDC to 31 VDC, Special Application Sound Type/Setting Steady/High Steady/Low Coded/High Coded/Low Reverberant Chamber, UL 464 Test 87.0 dBA 81.0 dBA 82.0 dBA 77.0 dBA Sound Output Ratings @ 10 ft (3 m) @ 17 VDC Anechoic Chamber, ULC 525 Test 94.5 dBA 90.0 dBA 94.5 dBA 90.0 dBA Candela Setting 15 cd 30 cd 75 cd 110 cd 17 VDC RMS Current Ratings, with horn on continuousat high setting, use when connected to TrueAlertAddressable SLCs per above 74 mA 85 mA 140 mA 185 mA *Not compatible with A49AVH-APPLC. For connection to legacy fire panel models Simplex 4009T and 4100/TPS. High candela (49AVH) appliances are not compatible with Simplex models 4009T and TPS, see the fire panel compatibility charts. Page 5 AC49AVC-0001 Rev. 8 01/2020 Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV AC49AVC-0001 Rev. 8 01/2020 © 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV 49MTV-APPLW CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0380 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Models 49MTV-WRF, 49MTV-WRF-BA, 49MTV-WRS, 49MTV-WRS-BA, 49MTV-WWF, 49MTV-WWF-BA, 49MTV-WWS, 49MTV-WWS-BA, 49MTV-WRQ, 49MTV-WRQ-BA, 49MTV-APPLW, and 49MTV-APPLW-BA True Alert ES Addressable Horn/Strobes. Models 49CMTV-WRF, 49CMTV-WRF-BA, 49CMTV-WWF, 49CMTV-WWF-BA, 49CMTV-APPLW, and 49CMTV-APPLW-BA True Alert ES Non-Addressable Horn/Strobes. Models 49SV-APPLW-O, 49SV-APPLW-O-BA, and 49SV-APPLW-CO, True Alert ES Addressable wall mounted *Speaker/Strobes. *Models 49AO-APPLC-O, 49AO-APPLC-O-BA, 49AVH-APPLC-O, 49AVH-APPLC-O-BA, 49AVH-APPLC-CO, 49VOH-APPLC-O, 49VOH-APPLC-O-BA, and 49VOH-APPLC-CO True Alert ES Addressable Horn/Strobes. Models 49VO-APPLC, 49VO-APPLC-BA, 49VOH-APPLCA, 49VOH-APPLCA-BA, 49VOH-APPLCB, 49VOH-APPLCB-BA, 49VOH-APPLC, 49VOH-APPLC-BA, 49VOC-CRALT, 49VOC-CRBF, 49VOC-CRFEU, 49VOC-CRF, 49VOC-CRS, 49VOC-CWALT, 49VOC-CWBF, 49VOC-CWFEU, 49VOC-CWF, 49VOC-CWS, 49VOC-CK, 49VOC-CRBAF, 49VOC-CRBCF, 49VOC-CWBAF, 49VOC-CWBCF, 49VOC-CRBAA, 49VOC-CWBAA, 49VO-APCS, 49AV-APPLC, 49AV-APPLC-BA, 49AVH-APPLC, 49AVH-APPLC-BA, 49AVH-APPLCA, 49AVH-APPLCA-BA, 49AVH-APPLCB, 49AVH-APPLCB-BA, 49AO-APPLC, 49AO-APPLC-BA, 49AVC-CRALT, 49AVC-CRBF, 49AVC-CRFEU, 49AVC-CRFIRE, 49AVC-CRS, 49AVC-CWALT, 49AVC-CWBF, 49AVC-CWFEU, 49AVC-CWFIRE, 49AVC-CWS, 49AVC-CK, 49AVC-CRBAF, 49AVC-CWCALT, 49AVC-CWBAF, 49AVC-CRBAA, 49AVC-CWBAA, 49AOC-CRALT, 49AOC-CRBF, 49AOC-CRFEU, 49AOC-CRFIRE, 49AOC-CRS, 49AOC-CWALT, 49AOC-CWBF, 49AOC-CWFEU, 49AOC-CWFIRE, 49AOC-CWS, 49AOC-CK, 49AOC-CRBAF, 49AOC-CWCALT, 49AOC-CWBAF, 49AOC-CRBAA, 49AOC-CWBAA, 49AV-APPLW-BA, 49VO-APPLW-BA, 49AO-APPLW-BA, 49AV-APPLW-O-BA, 49VO-APPLW-O-BA, and 49VO-APPLWE-BA, Models 49PBB-SOWR, 49PBB-SOWW, 49PBB-SVWR, and 49WPBB-SVWW backboxes. Refer to listee's data sheet for additional detailed product description and operational *Revision 09-25-20 VWW July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. Listing No. Page 2 of 2 7125-0026:0380 considerations. RATING: Voltage: 16-33 Vdc Candela: 49SV-APPLW-O, 49SV-APPLW-O-BA 15, 75, 110, 185 49SV-APPLW-CO 5, 15, 30, 45, 60, 75 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn/strobes and *speaker/strobes when used with separately listed electrically compatible fire alarm control units. Units are approved for indoor use and suitable for wall or ceiling mounts. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee’s Installation Instructions Manual for details. *Revision 09-25-20 VWW July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 49MTV-APPLW DATASHEET.pdfAudible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output AC49MTV-0001 Rev. 6 7/2016 Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output * Additional listings may be applicable; contact your local Autocall product supplier for the latest status. UL, ULC Listed* TrueAlert Addressable Notification Appliances Features Individually addressed and controlled multi-tone and multi-candela TrueAlert ES A/V (audible/visible) notification appliances provide: • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, 110, 135, or 185 cd • Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup • Wiring supervision to each appliance allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel • Per appliance tone selection of: 520 Hz Horn, Broadband Horn, Bell, Chime, High/Low, Slow Whoop, or Siren; programmable from the control panel, or selected using an on-board DIP Switch (refer to Table 9) • 520 Hz tone is compliant with NFPA 72 Low Frequency Signal Requirements for Sleeping Areas • Horn, Bell, and High/Low tones can be controlled as: Temporal Code 3, Temporal Code 4, March Time (selectable as 20, 60, or 120 bpm), or Continuous • Slow Whoop, Siren, and Chime tone selections are controlled as synchronized continuous operation • Output of "high" or "low" (~6 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance • TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting • Magnet Test diagnostics to assist checkout and testing of appliances and wiring • Electrical test point access without removing cover • Compatibility with ADA requirements; (refer to Installation Reference on page 4) • Strobe operation is listed to UL Standard 1971 and ULC Standard S526; Horn operation is listed to UL Standard 464 and ULC Standard S525 LED Indicator and Magnet Test feature: • Appliance LED can be selected to display each polling cycle to indicate appliance supervision • When the controller is in diagnostic mode, the Magnet Test pulses the LED to indicate appliance address and can be set to also briefly flash the strobe and sound the horn Mechanical design features include: • Rugged, high impact, flame retardant thermoplastic housing in red with white letters or white with red letters, with clear lens, available with FIRE, ALERT, or blank lettering • Separate covers are available to change application type on-site or for replacement; covers can be easily removed without disturbing the connected housing and avoiding trouble conditions • A separate mounting plate allows wiring to be completed before appliance is mounted; use with single gang, double gang, or 4-inch square box, flush or surface mount • In/out wiring terminals for 18 AWG to 12 AWG • Optional mounting adapters are available to cover surface mounted electrical boxes and to adapt to Autocall, 2975-9145 boxes Fig 1: TrueAlert ES Multi-Tone Addressable A/Vs are Available in Red with White Lettering and White with Red Lettering Description TrueAlert ES addressable multi-tone A/Vs TrueAlert ES addressable multi-tone A/Vs are individually addressed audible/visible notification appliances that receive power, supervision, and control signals from a Autocall fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See IDNAC SLC Controller Compatibility Reference on page 5.) Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert ES Operation Advantage TrueAlert ES addressable appliances on IDNAC SLCs provide separate visible and audible notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of Self-Test and Magnet Test features improve installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Page 2 AC49MTV-0001 Rev. 6 7/2016 Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output TrueAlert ES Diagnostics Test Features. When IDNAC SLCs are in diagnostic mode, Self-Test and Magnet Test features provide individual appliance testing. With the Self-Test feature, appliance operation can be confirmed without leaving the control panel. Additionally, each appliance’s LED can be selected to pulse when it receives a supervision poll during normal operation. Self-Test Details. Selecting Self-Test Mode from the control panel allows on-board sensors, depending on the device type, to detect its own strobe and/ or horn output and then report their status to the control panel. Operation is by selected VNAC appliance groups and is either automatic (all briefly simultaneously activated) or individually activated by applying a magnet. (Refer to control panel data sheet for more Self-Test information, see IDNAC SLC Controller Compatibility Reference on page 5.) Silent Appliance Magnet Test. In this test mode, in response to application of a magnet, the appliance LED pulses sequentially to conveniently indicate the appliance’s address. Operational Appliance Magnet Test. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash and the horn will briefly sound to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (See data sheet AC4905-0001 .) Product Selection Table 1: TrueAlert ES Wall Mount Multi-Tone Addressable Audible/Visible Appliances SKU Cover Color Wording Lens Color TrueAlert ES multi-tone addressable A/V appliances include cover and matching mounting plate except as noted; Dimensions with Cover = 5 ⅛" H x 5" W x 2 ⅝" D (130 mm x 127 mm x 67 mm) A49MTV-APPLW Select cover and mounting plate separately Table 2: TrueAlert ES Wall Mount Multi-Tone Addressable Audible/Visible Appliances SKU Color SKU Color Note A49MP-AVVOWR Red A49MP-AVVOWW White Mounting Plate, select color to match cover * Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA, APPLW models, and separate mounting plates are assembled in the USA. Table 3: Separate Covers (Required when ordering model 49MTV-APPLW(-BA), uses same covers as A49AV Series fixed tone A/Vs) SKU Color Wording A49AVC-WRFIRE Red A49AVC-WWFIRE White FIRE A49AVC-WRALT Red A49AVC-WWALT White ALERT A49AVC-WRS Red Logos Only A49AVC-WWS White Logos Only Page 3 AC49MTV-0001 Rev. 6 7/2016 Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Table 4: Separate Covers (Required when ordering model 49MTV-APPLW(-BA), uses same covers as A49AV Series fixed tone A/Vs) SKU Color Wording A49AVC-WRFIRE Red A49AVC-WWFIRE White FIRE A49AVC-WRALT Red A49AVC-WWALT White ALERT A49AVC-WRS Red A49AVC-WWS White Logos Only Table 5: Mounting Adapters SKU Color Description Dimensions A4905-9937 Red A4905-9940 White Surface Mount Adapter Skirt 5 ⅜" H x 5 ¼" W x 1 ⅝" D (136 mm x 133 mm x 41 mm) Total depth with strobe = 4 ⅜" (111 mm) A4905-9931 Red Adapter Plate for mounting to Autocall, 2975-9145 Box (typically for retrofit, mount vertical or horizontal) 8 5⁄16" x 5 ¾" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires A4905-9931 Adapter Plate 7 ⅞" x 5 ⅛" x 2 ¾" D (200 mm x 130 mm x 70 mm) Page 4 AC49MTV-0001 Rev. 6 7/2016 Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Installation Reference TrueAlert ES A/V Specifications Table 6: Electrical specifications Typical Operating Voltage Range 23 VDC to 29.5 VDC, Special Application Supervisory Requirements 2 unit loads (1 unit load = 0.8 mA control panel current)Electrical Ratings A49MTV Series SLC Loading Up to 21 appliances can connect directly to the panel IDNAC SLC or to a 4009 IDNAC Repeater output, to a maximum of 127 addresses and 139 unit loads per SLC UTP , unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) IDNAC SLC Wiring Specifications (refer to control panel or power supply installation instructions for more information) Maximum wire length to any appliance = 4000 ft (1219 m) Table 7: Tone Characteristics 520 Hz Horn 520 Hz tone Broadband Horn Combination 600/3000 Hz signal Bell Synthesized Bell tone High/Low Alternating modulated tones with fundamentals of 1000 Hz and 800 Hz, 250 ms duration each These tones are compatible with control panel IDNAC commands for operation as Temporal Code 3, Temporal Code 4, March Time at 20, 60, or 120 bpm, or Continuous operation Slow Whoop Modulated 520 Hz to 1200 Hz sweep with 2 s duration Siren Modulated 600 Hz to 1200 Hz to 600 Hz sweep, with 2 s duration Chime Multi-phase signal with a peak and decay time of 1 s These tones operate as Continuous with synchronization Table 8: TrueAlert ES Multi-Tone Horn/Strobe Current Ratings RMS Current Ratings @ 23 VDC, in mA 15 cd 30 cd 75 cd 110 cd 135 cd 185 cd Tone High Low High Low High Low High Low High Low High Low 520 Hz Horn and High/Low 145 108 163 125 198 158 230 195 262 214 299 257 Page 5 AC49MTV-0001 Rev. 6 7/2016 Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Table 8: TrueAlert ES Multi-Tone Horn/Strobe Current Ratings RMS Current Ratings @ 23 VDC, in mA 15 cd 30 cd 75 cd 110 cd 135 cd 185 cd Tone High Low High Low High Low High Low High Low High Low Broadband Horn, Bell, Chime, Slow Whoop, and Siren 135 99 152 111 185 139 212 172 247 203 284 243 Table 9: TrueAlert ES Multi-Tone Horn/Strobe Horn Output UL 464 Output Ratings @ 23 VDC and 29.5 VDC (dBA)* ULC S525 Output Ratings @ 23 VDC and 29.5 VDC (dBA)* Steady High Steady Low Coded High Coded Low Steady High Steady Low Coded High Coded Low Tone Voltage 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 520 Hz Horn 80 80 74** 75 76 76 70** 71** 83† 79† 83† 78† High/Low 81 82 77 77 75 76 70** 71** 87 82† 86† 82† Broadband Horn 84 84 79 79 81 81 74** 75 88 84† 87† 83† Bell 80 80 75 75 76 76 71** 71** 85 80† 85† 80† Slow Whoop 79 80 74** 75 85 80† Siren 79 80 74** 75 85 80† Chime** 67** 67** 62** 62** these tones are not used for coded operation 82† 77† these tones are not used for coded operation * Output ratings are at 10 ft (3 m); UL 464 ratings are per UL Reverberant Chamber testing; ULC S525 ratings are per ULC Anechoic Chamber testing. The tone generator circuit is DC-DC converter powered and provides essentially constant output over the rated voltage range. ** UL output ratings below 75 dBA are for NFPA 72 Private Mode applications. † ULC output ratings below 85 dBA are for use in applications per applicable local codes. Table 10: Sound Output Dispersion per ULC S541 Anechoic Testing Horizontal -3 dBA @ ±37° -6 dBA @ ±40° -9.4 dBA @ ±90° Vertical -3 dBA @ -24°, +42° -6 dBA @ -59°, +50° -8.6 dBA @ ±90° Table 11: General Specifications Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing @ 104° F (40° C) Connections Terminal blocks on mounting plate for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring 579-1156AC for A49MTV Series A/V appliances Installation Instructions 579-1100AC for A49MP Series mounting plates IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 4007ES with IDNAC Notification AC4007-0002 4010ES with ESS Enhanced System Supply AC4010-0011 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) AC49MTV-0001 Rev. 6 7/2016 © 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 49VO-APPLC CSFM LISTING.pdf CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0371 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Steven Burgess (978) 731-8483 Fax (978) 731-8881 Email: steven.burgess@jci.com DESIGN: Model 49AV Horn/strobe with suffixes WRFO, WRFO-BA, WWFO-BA,and APPLW-O. Model 49AVC Horn/strobe with suffixes WRFIRE-O, WWFIRE-O, WRALT-O, WWALT-O, WRFEU-O, WWFEU-O, WRBLNG-O, WWBLNG-O, WRS-O, and WWS-O. Model 49VO Strobe with suffixes WRFO, WRFO-BA, WWFO-BA, *WRSO, WRSO-BA, and APPLW-O. Model 49VOC Strobe with suffixes WRFIRE-O, WWFIRE-O, WRALT-O, WWALT-O, WRFEU-O, WWFEU-O, WRBLNG-O, WWBLNG-O, WRS-O, and WWS-O.. Refer to listee's data sheet for detailed product description and operational consideration. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired. Refer to listee’s Installation Instruction Manual for details. *Rev 09-25-13 gt July 01, 2020Date Issued: Listing Expires June 30, 2021 Authorized By: Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other DAVID CASTILLO,, M.E., F.P.E. 49VO-APPLC DATASHEET.pdf49VOC-0001_miramo.xml Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49VO * Additional listings may be applicable; contact your local Autocall product supplier for the latest status. UL, ULC Listed* TrueAlert ES Addressable Notification Appliances AC49VOC-0001 Rev. 7 10/2018 Description Ceiling Mount Addressable Visible (V/O) Notification Appliances are individually powered, addressed, and controlled from an Autocall fire alarm control panel IDNAC Signaling Line Circuit (SLC). V/O notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process. Features Individually addressed Visible Only (V/O) notification appliances • Multi-candela LED strobe available in low (15, 30 75 and 110 cd) and high (110 , 135 and 185 cd) range candela models . • Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators. • Advanced addressable notification controlled by IDNAC SLCs. • IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current • Electrical test point access by removing the cover • Strobe intensity can be programmed from the control panel or the device • Wiring supervision to each appliance allows T-tapped connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) • Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the control panel • TrueAlert Device Reports at the control panel detail appliance point ID, custom label, type, and candela setting • Magnet test diagnostics assist checkout and testing of appliances and wiring • Compatibility with ADA requirements • Strobe operation is listed to UL Standard 1971 and ULC Standard S526 • Synchronized strobe operation on its IDNAC channel. LED Indicator and Magnet Test feature: • Indicator LED indicates magnet test acknowledgment, 3 digit IDNAC address, and candela rating • Indicator LED can be configured to blink every polling cycle to indicate appliance supervision • When the controller is in diagnostic mode, the magnet test pulses the Indicator LED to indicate appliance address and can be set to also briefly flash the strobe LEDs Mechanical design features • Rugged, high impact, flame retardant thermoplastic housing in red and white colors • Various covers and lettering options available – Red with white letters or white with red letters • Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions • In/out wiring terminals for 18 AWG to 12 AWG • Mounts on 4” square or single gang USA electrical boxes. Adapter plate required for mounting on single gang electrical boxes. • Optional wire guards • Weatherproof back boxes are required for surface mounting. Figure 1: Indoor Ceiling Mount Strobe Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, and local codes. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet AC4905-0001 for additional information. TrueAlert ES Diagnostics Test Features Controllers can be selected to pulse each appliance’s LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance’s address when a magnet is applied. Operational Appliance Magnet Test In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Autocall representative for additional information. Page 2 AC49VOC-0001 Rev. 7 10/2018 Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49VO Installation Reference IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire circuit that also confirms connection to the individual notification appliance’s electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be T-tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1: Ceiling Mount Addressable Visual Only V/O Appliances SKU* Lens color Description A49VO-APPLC A49VO-APPLC-BA A49VOH-APPLC A49VOH-APPLC-BA Clear VO appliance only. Select cover separately. Table 2: Surface/WP back boxes SKU Color Description Installation instructions A49WPBB-VOCR Red Surface/WP back box in red A49WPBB-VOCW White Surface/WP back box in white 579-1270AC Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. Page 3 AC49VOC-0001 Rev. 7 10/2018 Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49VO Table 3: Adapter plates SKU Description 49VO-APCS VO Ceiling Mount Adapter Plate. Required for mounting on a single gang electrical box. Table 4: V/O Covers (Required when ordering APPLC models) SKU* Color Wording A49VOC-CRALT ALERT A49VOC-CRBF FEU/FIRE A49VOC-CRFEU FEU A49VOC-CRF FIRE A49VOC-CRS Autocall logo only A49VOC-CRBAA إﻧﺬار /ALERT A49VOC-CRBCF 火警/FIRE A49VOC-CRBAF Red ﺣﺮﻳﻖ/FIRE A49VOC-CK Black Blank A49VOC-CWALT ALERT A49VOC-CWBF FEU/FIRE A49VOC-CWFEU FEU A49VOC-CWF FIRE A49VOC-CWS Autocall logo only A49VOC-CWBAA إﻧﺬار /ALERT A49VOC-CWBCF 火警/FIRE A49VOC-CWBAF White ﺣﺮﻳﻖ/FIRE Table 5: Wire Guards SKU Description A49WG-VOCR VO Ceiling Mount Red Wire Guard A49WGBB-VOCR-O VO Ceiling Mount Wire Guard Back Box Note: * (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in –BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6: Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 4100ES Flex 35, 50, and 100 Amplifiers 4100ES Constant Supervision and Signal Cards AC4100-0034 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) AC49VOC-0001 Rev. 7 10/2018 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49VO TrueAlert ES V/O LEGACY Compatibility Reference Table 7: Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum 4100ES with TrueAlert Power Supply AC4100-0031 4009 TPS, Remote TrueAlert 17 VDC Power Supply AC4100-0037 TrueAlert Addressable Controller (4009T) AC4009-0003 TrueAlert Addressable SLC 15, 30, 75, and 110 cd 17 VDC Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 cd 30 cd 30 cd 110 cd 17 VDC RMS Current Ratings, with horn on continuousat high setting, use when connected to TrueAlertAddressable SLCs per above 74 mA 85 mA 140 mA 185 mA Ceiling Mount V/O Specifications Table 8: Specifications Specification Rating Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Installation Instructions 579-1227AC (A49VO and A49VOH models). Table 9: Percentage of rated light output at room temperature On-Axis Vertical, Below Axis Horizontal, Left/Right of Axis Angle 0° 45° 90° 45° 90° UL required output 100% 45% 25% 45% 25% Typical output 327% 134% 83% 129% 47% Table 10: Appliance Specifications Specification Rating Operating Voltage Range 23 VDC to 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max 127 S/V appliances per IDNAC channel Candela Setting 15 cd 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd A49VO model 55 mA 83 mA 159 mA N/A 199 mA N/A N/A A49VOH model N/A N/A 272 mA N/A 253 mA 296 mA 377 mA A49VOH amber lens N/A N/A N/A 272 mA 300 mA 355 mA N/A Current consumption** A49VOH blue lens N/A N/A 72 mA 300 mA 355 mA mA N/A ** Measured at 23VDC on IDNAC Addressable SLC