Loading...
HomeMy WebLinkAbout055-540-045 EHDR19-00347 SEPTIC REPORT CAMP FIRE Form revision: December 29, 2015 System Owner and Parcel Identification System Owner: Billson Construction, Permit #B20-2840 APN: Click here to enter text. System Address: 432 Bay Tree Drive, Paradise, CA 95969 System Components (Check all that apply): ☒ A. Septic tank  ☐ B. ATU/Packed Bed  ☐ C. Gravity Dispersal, or ☐ D. Pressure Dispersal Inspection Checklist Wastewater System Component PD OK RS N/A A. Septic Tank 1. Scum and sludge level measured ☐ ☒ ☐ ☐ 2. Tank inspected for integrity ☐ ☒ ☐ ☐ 3. Effluent filter checked ☐ ☒ ☐ ☐ B. ATU or Packed Bed (submit inspection checksheet approved by the Proprietor) C. Gravity Dispersal Drainfield (if applicable) 1. Depth of effluent ponding within trench: Click here to enter text. ☐ ☐ ☐ ☒ 2. Inspected for indication of effluent breakout or discharge to surface of the ground ☐ ☐ ☐ ☒ 3. Observation ports accessible and maintained ☐ ☐ ☐ ☒ 4. Area free from roads, structures, vehicular traffic ☐ ☐ ☐ ☒ 5. Surface water drainage and down spouts diverted from drainfield area ☐ ☐ ☐ ☒ D.1. Control Panel (if applicable) 1. Timer/digital counter readings recorded during inspection for future reference? Note: For control panels that record pump activity electronically, counter operation can be verified remotely. Yes No N/A ☒ ☐ ☐ 2. Pump cycle counter operation verified by manual operation of the pump Note: For control panels that record pump activity electronically, counter operation can be verified remotely. ☐ ☒ ☐ ☐ 3. Audible and visual alarms tested ☐ ☒ ☐ ☐ 4. Run time checked if dispersal field demand-dosed ☐ ☐ ☐ ☒ 5. Electrical box inspected for moisture and secure connections ☐ ☒ ☐ ☐ D.2. Pressure Dispersal Drainfield 1. Trench/bed checked for excessive ponding ☐ ☐ ☐ ☒ 2. Dispersal area check out for effluent breakout or surfacing ☐ ☐ ☐ ☒ 3. Observation ports accessible and maintained ☐ ☐ ☐ ☒ 4. Dispersal area free from roads, structures, vehicular traffic ☐ ☐ ☐ ☒ 5. Surface water drainage and down spouts diverted from dispersal area ☐ ☐ ☐ ☒ 6. Equal distribution confirmed by measuring distal end orifice pressure head ☐ ☐ ☐ ☒ 7. Orifices in good condition and not in need of hydroflushing ☐ ☐ ☐ ☒ Problem detected, additional service required Component inspected and in satisfactory condition Component not present or not inspected OK PD Routine service provided during service call N/A RS Form revision: December 29, 2015 Constituent Analysis Constituent Result Sample Date Lab 1. Influent BOD N/A Click here to enter a date. Click here to enter text. 2. Influent TSS N/A Click here to enter a date. Click here to enter text. 3. Effluent BOD N/A Click here to enter a date. Click here to enter text. 4. Effluent TSS N/A Click here to enter a date. Click here to enter text. Inspector Comments This septic tank pumps its effluent to a transport line that goes to the main, community system. We found no problems at this time. Certification I certified that I am an OM&M Specialist certified by Butte County Environmental Health (LEA) and the information provided in this report is based on my observations and is true to the best of my knowledge. 4/21/2021 OM&M Specialist Signature Date of Inspection Hydrotec Solutions, Inc. Company Name Return to Butte County Environmental Health with completed Operating Permit application and fee. Mailing address: 202 Mira Loma Drive Oroville, CA 95965 530-538-7281