Loading...
HomeMy WebLinkAboutA007-9201 CSFM LISTING LPG 51"py PFIxFsq�pMjEMp, CALIFORNIA DEPARTMENT OF FORESTRY&FIRE PROTECTION �PCAL ro+ OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING-BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0378 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT(COMMERCIAL) LISTEE: Simplex50 Technology Drive,Westminster, MA 01441-0001 Contact: Steven Burgess (978)731-8483 Fax(978)731-8881 Email: steven.burgess@jci.com DESIGN: Models 4007-9101,4007-9101AR,4007-9102, 4007-9201 and 4007-9202 Commercial Fire Alarm Control Panels. Local, auxiliary, remote station, releasing and central station service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 4007-9801;Zone/Relay Module 4007-9802; 25V Regulator Module 4007-9803; IDNet+Loop Module 4007-9804; Dual Class A Isolator Module 4007-9805; 24 Zone LED Module 4007-9806; SDACT Module 4007-9807; City Circuit Module with Disconnect Switch 4007-9808; City Circuit Module without Disconnect Switch 4007-9809;Alarm Relay Module 4007-9810; Flat Network Card Interface 4007-9812; Dual RS232 Module 4007-9813;Wired Media Module 4007-9814; Fiber-Optic Media Module 4190-8001; Remote Service Gateway 0566-989; IDNAC Power Supply 0566-1023; CPU and User Interface 0566-1030; NAC Power Supply 4190-6106; Remote Service Gateway *4007-6306; ES Net NIC Dual Channel Ethernet Media Card *4007-6307; ES Net NIC Dual Channel DSL Media Car *4007-6308; ES Net NIC Dual Channel Single-mode Fiber Media Card *4007-6309; ES Net NIC Dual Channel Multi-mode Fiber Media Card *4007-9817; ES Net Network Card-Flat 4007 RATING: 2A @ 120 VAC 50/60 HZ 1A @ 240 VAC 50/60 HZ INSTALLATION: In accordance with listee's printed installation instructions, applicable codes&ordinances and in a manner acceptable to the authority having jurisdiction. *Revision 12-21-2018 dcc %—rf-, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed O` the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct '"1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division Listing No. 7165-0026:0378 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation)in accordance with NFPA 72, 2010 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: For Fire Alarm Verification Feature(delay of fire alarm signal),the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Alarm Verification shall not be implemented on initiation-device circuits thaqt have the option of releasing an extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. *Revision 12-21-2018 dcc *-';s*c;, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not O` an endorsement or recommendation of the item listed. This listing should not be used to verify correct I operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division