Loading...
HomeMy WebLinkAboutHWF-2A SPEC SHEET .0m SERIES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire HWF2A-COM alarm control panel) with a built-in dialer. liewm Mu nra ° rutr Models include: HWF2A-COM(AT&T LTE&IP) HWF2V-COM(Verizon LTE&IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter(DACT). Three selectable reporting paths include:LTE cellular only,IP only,or IP primary with LTE cellular backup.All signals from the HWF2-COM Series are delivered to the AlarmNet° network control center which routes highly encrypted,cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station.The AlarmNet°network control center is fully redundant and monitored 24/7.Installation and programming are easy using the handheld 7720P Programming tool. HWF2V-COM I:a FEATURES AND BENEFITS • LTE and IP connection tested every day connection(LAN or WAN),DSL model or • Diagnostic LEDs indicate signal strength • Three selectable reporting paths:LTE cable modem and status cellular only,IP only,or IP Primary with LTE • Data transmits over standard Contact ID • Choice of LTE provider services cellular backup protocol but is secured with the industry's • QOS:Quality of Service diagnostics via • Requires no change to the existing FACP advanced encryption standard(AES 256 configuration bit) AlarmNet conveys vital communicator information including signal strength, • Connects directly to the primary and • Supports both dynamic(DHCP)or public message path used,and when the message secondary telephone ports of a DACT and private Static IP addressing was received • Plan choices range from 5 minute,60 • Reliable connection:IP and cellular • 7720P Handheld programmer for easy minute,6 hour,and 24 hour supervision connection tested every day setup intervals • Built-in,standalone power supply module. • Operates overthefollowing communication Onboard charging circuit design protocols:LTE,HSPA+(4G)HSPA(3G) accommodates battery backup.Includes • Works over any type of customer provided primary power and battery supervision Ethernet 10/100 based network Honeywell The HWF2-COM LTE/IP fire communicators operate over the most • Primary Subscriber ID(four digits),obtained from your monitoring modern and common cellular networks including LTE,4G and3G. station • Communication Module MAC ID,and MAC CRC number located on They connect to any customer provided Ethernet 10/100 base the outside of the box and inside of the module network connection(LAN or WAN),DSL or cable modem.Selectable All parameters are assigned by the monitoring station. reporting path feature allows the radios to be configured for a single or dual path,while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements.Selectable paths and supervision AlarmNet communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals.The network WELECTA DESCRIPTION SUPERVISIal 'IFprovides extensive coverage in the United States and Canada.The PATH TIMES AlarmNet Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure 2010 Cell Single path,cellular 5 Minutes support.Redundant hardware servers,real-time backup databases, 2010 IP Single path,IP 5 Minutes and generators with battery backup at all locations ensure 2010 IP&Cell Dual path,IP and cellular 24 Hours continuity of service.Signals from AlarmNet are transmitted to 2013 Cell Single path,cellular 60 Minutes central station receivers using multiple communication paths consisting of the Internet,LTE radio network,or toll free plain old 2013 IP Single path,IP 60 Minutes telephone service(POTS).Visit AlarmNet.com to learn more. 2013 IP&Cell Dual path,IP and cellular 6 Hours INSTALLATION REQUIREMENTS,UL COMPLIANCE OPERATION To meet UL864/NFPA requirements,ensure the following: When an event occurs,the FACP goes off-hook to dial the central station.The HWF2 COM Series dialer capture module detects the • HWF2-COM Series must be installed in accordance with the National off-hook condition and provides the fire panelwith a dialtone.When Fire Protection Association(NFPA)standards 70 and 72 the fire panel detects the dialtone,it begins dialing the central • HWF2-COM Series must be mounted in the same room and within station. 20 feet of the fire panel. • HWF2-COM Series and all equipment used for the IP connection After the dialing is completed,the dialer capture module returns a (e.g.,router,hub,modem,etc)must be UL-listed,powered from an signal to the fire panel.The fire panel then sends the Contact ID unswitched branch circuit,and be provided with appropriate standby reports to the dialer capture module,which in turn sends a signal power. after the report is successfully received from the fire panel.The • HWF2-COM Series must use the 7AH battery(not included)to dialer capture nodule sends the Contact ID reports to the HWF2- provide 24 hour backup capability COM Series communications module.When all the reports are sent, the fire panel goes on-hook.The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR/PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information.This is saved to the HWF2-COM communicator panel memory.When the HWF2-COM is installed at the site and connected to the Internet/ Intranet,it registers with the AlarmNet Receiver. For most installations,the only required parameters are: • Primary City ID(two digits),obtained from your monitoring station • Primary Central Station ID(two digits),obtained from your monitoring station Page 2 of 3—DH-62010:C•6/10/2020 HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Both models include: Transformer: • Red cabinet with key and lock AlarmNet°is a registered trademark • Primary:120VAC,60Hz,0.5A • Wall outlet box of Honeywell International Inc. • Secondary:18VDC,50VA • Dialer capture module 02019 by Honeywell International Battery: • LTE communications module Inc.All rights reserved. • One 12 V 7.0 AH lead-acid battery:(not • Antenna and mounting adapter Unauthorized use of this document supplied) • PowerBoostl power supply is strictly prohibited. • • Battery charging current:1 Amp maximum LED display board • Battery discharge current:Standby 210mA, • Transformer This document is not intended to be Active 290mA • Manual and required screws used for installation purposes.We • Cables,etc. try to keep our product information CABINET SPECIFICATIONS up-to-date and accurate.We cannot ANTENNA AND EXTERNAL cover all specific applications or • Dimensions:14.875"H x 12.75"Wx 3.0"D HARDWARE (37.8cm H x 32.4cm W x 7.6cm D) anticipate all requirements.All • Color:Red CELL-ANT3DB:3dBA gain antenna specifications are subject to change WA7626-CA:SMAto N adapter cable without notice. SHIPPING DIMENSIONS 7626-50HC:50 ft.antenna cable,low loss Country of origin:USA • Weight:5.3 lbs(6.94kg) • Dimensions:15.625"H x 13.79"W x 9.25"D Note:The WA7626-CA adapter cable and (39.7cm H x 34.9cm W x 23.9cm D) 7626-50HC antenna cable are only required when installing the CELL-ANT3DB TEMPERATURE AND HUMIDITY antenna remotely. RANGES OTHER ACCESSORIES This system meets NFPA requirements for operation at 0 49°C/32-120°F and at a 7720P:HWF2V-COM,HWF2A-COM and relative humidity 93%+-2%RH(non- IPGSM-4G handheld programmer condensing at 32°C+-2°C(90°F+ 3°F). HPTCOVER:Plug-in transformer box for However the useful life of the system's HWF2V-COM,HWF2A-COM,and IPGSM- standby batteries and the electronic 4G communicators components may be adversely affected by BAT-1270:Battery 12 Volts,7AH,sealed extreme temperature ranges and humidity. AGENCY LISTINGS AND Therefore,it is recommended that this APPROVALS system and its peripherals be installed in an environment with a normal room The listings and approvals below apply to temperature of 15-27°C/60-80°F. the HWF2-COM Series communicators.In some cases,certain modules may not be PRODUCT LINE INFORMATION listed by certain approval agencies,or listing HWF2V-COM:LTE Digital Cellular Fire may be in process.Consult the factory for Alarm Communicator and Internet Panel, latest listings. Verizon LTE/IP UL Listed:S789 HWF2A-COM:LTE Digital Cellular Fire CSFM:7300-1645:0511 Alarm Communicator and Internet Panel, FDNY:Approved AT&T LTE/IP THE FUTURE IS Honeywell Power Products WHAT 12 Clintonville Road WE MAKE IT Northford,CT 06472-1610 203.484.7161 DH-62010 I C 106/20 p www.honeywellpower.com ©2020 Honeywell International Inc. Honeywell