49VO-APPLC DATASHEET
( AUTO CALL TrueAlert ES Addressable Notification Appliances UL, ULC Listed* Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49V0 Description Ceiling Mount Addressable Visible(V/O)Notification Appliances are individually powered,addressed,and controlled from an Autocall fire alarm control panel IDNAC Signaling Line Circuit(SLC).V/0 notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate • and selectable candela rating.LED and Xenon tube strobes devices • are interoperable on the same IDNAC channel.Separate appliance and • cover selection greatly simplifies the ordering and installation process. a Features Individually addressed Visible Only(V/O)notification appliances • Multi-candela LED strobe available in low(15,30 75 and 110 cd)and high(110,135 and 185 cd)range candela models. Figure 1: Indoor Ceiling Mount Strobe • Small compact design and low current draw due to energy efficient Xenon tube strobes,with LED indicators. Strobe Application Reference •Advanced addressable notification controlled by IDNAC SLCs. Proper selection of visible notification is dependent on occupancy, • IDNAC SLCs provide regulated 29 VDC allowing horns to operate with location,and local codes. lower current • Electrical test point access by removing the cover TrueAlert Addressable Wiring Isolator • Strobe intensity can be programmed from the control panel or the Isolator Model A4905-9929 device Isolator Model A4905-9929 is available for remote mounting on • Wiring supervision to each appliance allows T-tapped connections for TrueAlert addressable circuits to isolate short circuited wiring from Class B circuits to simplify wiring(Class A circuits require in/out wiring) functioning wiring.Refer to data sheet AC4905-0001 for additional • Self-Test Mode allows on-board sensors to detect the strobe output information. and then report their status to the control panel •TrueAlert Device Reports at the control panel detail appliance point ID, TrueAlert ES Diagnostics custom label,type,and candela setting • Magnet test diagnostics assist checkout and testing of appliances and Test Features wiring Controllers can be selected to pulse each appliance's LED when it • Compatibility with ADA requirements receives a supervision poll.When the controller is selected for diagnostic • Strobe operation is listed to UL Standard 1971 and ULC Standard S526 mode,the appliance magnet test feature provides a response at the individual appliance being tested. • Synchronized strobe operation on its IDNAC channel. Silent Appliance Magnet Test LED Indicator and Magnet Test feature: The appliance LED pulses sequentially to conveniently indicate the • Indicator LED indicates magnet test acknowledgment,3 digit IDNAC appliance's address when a magnet is applied. address,and candela rating • Indicator LED can be configured to blink every polling cycle to indicate Operational Appliance Magnet Test appliance supervision In this test mode,after the address is indicated by pulsing the appliance • When the controller is in diagnostic mode,the magnet test pulses the LED,the strobe will briefly flash to indicate proper operation. Indicator LED to indicate appliance address and can be set to also TrueStart Instrument Two(TSIT) briefly flash the strobe LEDs The 2nd generation of the Autocall TrueStart Test Instrument adds Mechanical design features testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability • Rugged,high impact,flame retardant thermoplastic housing in red and to test IDCs,NACs,and IDNet communications before connection to white colors the control panel.Please contact your local Autocall representative for •Various covers and lettering options available-Red with white letters additional information. or white with red letters • Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions • In/out wiring terminals for 18 AWG to 12 AWG • Mounts on 4"square or single gang USA electrical boxes.Adapter plate required for mounting on single gang electrical boxes. • Optional wire guards • Weatherproof back boxes are required for surface mounting. *Additional listings may be applicable;contact your local Autocall product supplier for the latest status. AC49VOC-0001 Rev.7 10/2018 ( AUTOCALL Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49V0 Installation Reference _% Appliance with cover(front) Appliance (rear) Mount to 4"X 4"X 1-1/2" electrical box using 8-32 screws• --- Address dip switch 0 ~ \ Note:ceiling mount only Set device address before fixing cover in c-�_ place. _= (j ) Candela flag setting ���I������'% Set flag to FACP to control ` candela rating from an FACP providing IDNAC notification. To set candela manually,setWiring terminals for strobe �--- the flag to the desired connections candela rating. accept#12-18 AWG wires Use slotted screwdriver here to remove cover IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit.This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained,even during battery standby.This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby.Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification,support for more appliances per IDNAC SLC,use of smaller gauge wiring,or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC,installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used,wiring can be T-tapped,allowing more savings in distance,wire,conduit(size and utilization),and overall installation efficiency.Use of the magnet test feature improves installation efficiency.TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1:Ceiling Mount Addressable Visual Only V/O Appliances SKU* Lens color Description A49V0-APPLC A49V0 APPLC BA Clear VO appliance only.Select cover separately. A49VOH-APPLC A49VO H-APPLC-BA Table 2:Surface/WP back boxes SKU • Color Description Installation instructions A49WPBB-VOCR [Red Surface/WP back box in red 579-1270AC A49WPBB-VOCW (White (Surface/WP back box in white Note:Use WP back boxes for surface mounting only.Using weatherproof back boxes does not make an appliance weatherproof. Page 2 AC49VOC-0001 Rev.7 10/2018 ( AUTOCALL Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49V0 Table 3:Adapter plates SKU Description 49V0 APCS VO Ceiling Mount Adapter Plate.Required for mounting on a single gang electrical box. Table 4:V/O Covers(Required when ordering APPLC models) SKU* (Color Wording ' A49VOC-CRALT ALERT A49VOC-CRBF FEU/FIRE A49VOC-CRFEU FEU A49VOC-CRF FIRE A49VOC-CRS Red Autocall logo only A49VOC-CRBAA JLuI/ALERT A49VOC-CRBCF " /FIRE A49VOC-CRBAF A49VOC-CK Black Blank A49VOC-CWALT ALERT A49VOC-CWBF FEU/FIRE A49VOC-CWFEU FEU A49VOC-CWF FIRE A49VOC-CWS White Autocall logo only A49VOC-CWBAA Jail/ALERT A49VOC-CWBCF " /FIRE A49VOC-CWBAF y,>/FIRE Table 5:Wire Guards SKU (Description ' A49WG-VOCR IVO Ceiling Mount Red Wire Guard A49WGBB-VOCR-O IVO Ceiling Mount Wire Guard Back Box Note:*(-BA)indicates model is available either with or without the-BA suffix.Model numbers ending in-BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6:Compatibility Reference Data Sheet IDNAC SLC Output Appliance Voltage Compatible Controllers Reference Controller Output Voltage Design Reference 4100ES with EPS+or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 29 VDC 23 VDC IDNAC SLC 4100ES Flex 35,50,and 100 Amplifiers AC4100-0034 (regulated) (with 6 VDC drop) 4100ES Constant Supervision and Signal Cards Page 3 AC49VOC-0001 Rev.7 10/2018 ( AUTOCALL Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series A49V0 TrueAlert ES V/O LEGACY Compatibility Reference Table 7:Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensitypp iiance Voltage Minimum 4100ES with TrueAlert Power AC4100-0031 Supply 4009 TPS,Remote TrueAlert AC4100-0037 TrueAlert Addressable SLC 15,30,75,and 110 cd 17 VDC 17 VDC Power Supply TrueAlert Addressable AC4009-0003 Controller(4009T) Electrical Ratings Differences for Legacy Applications(refer to above specifications for other ratings) Voltage Range 17 VDC to 31 VDC,Special Application Candela Setting 15 cd 30 cd 30 cd 110 cd 17 VDC RMS Current Ratings,with horn on continuousat high setting, 74 mA 85 mA 140 mA 185 mA use when connected to TrueAlertAddressable SLCs per above Ceiling Mount V/O Specifications Table 8:Specifications Specification 1Rating Environmental 32°to 120°F(0°to 49°C);10%to 93%,non-condensing at 104°F(40°C) Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two Connections wires per terminal for in/out wiring.Use Unshielded Twisted Pair(UTP)for IDNAC. IDNAC SLC Loading Maximum of 127 addresses per SLC,139 unit loads.See device and compatible Fire Panel Installation Instructions for circuit current load limits. Installation Instructions I579-1227AC(A49V0 and A49VOH models). Table 9:Percentage of rated light output at room temperature Angle On-Axis Vertical,Below Axis Horizontal,Left/Right of Axis 0° 45° 90° 45° 90° UL required output 100% 45% 25% 45% 25% Typical output 327% 134% 83% 129% 147% Table 10:Appliance Specifications Specification Rating Operating Voltage Range 23 VDC to 30 VDC,Special Application Supervisory Requirements 1 unit load(=0.8 mA control panel current) Flash Rate and Synchronized SLC 1 Hz;with up to 63 synchronized strobes maximum per powered circuit,max 127 SN appliances per IDNAC Loading channel Candela 15 cd 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd Setting A49V0 model 55 mA 83 mA 159 mA N/A 199 mA N/A N/A Current A49VOH model N/A N/A 272 mA N/A 253 mA 296 mA 377 mA consumption** A49V0H amber N/A N/A N/A 272 mA 300 mA 355 mA N/A lens A49VOH blue N/A N/A 72 mA 300 mA 355 mA mA N/A lens **Measured at 23VDC on IDNAC Addressable SLC ©2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC49VOC-0001 Rev.7 10/2018