Loading...
HomeMy WebLinkAbout4098-9792 CSFM LISTING LPG 51"py PFIxFsq�pMjEMp, CALIFORNIA DEPARTMENT OF FORESTRY&FIRE PROTECTION �PCAL ro+ OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING-BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex50 Technology Drive,Westminster, MA 01441-0001 Contact: Steven Burgess (978)731-8483 Fax(978)731-8881 Email: steven.burgess@jci.com DESIGN: Models 4098'-9775, *-9776, *-9777, -9780,-9780E,-9789, -9789E, 9789TSP, -9789TTP, -9791, -9791E, -9791 TSP, 9791 TTP,-9792, -9792E, -9792TSP, 9792TTP, -9793, -9793E, -9793TSP, -9793TTP,-9796,-9796TSP, -9796TTP; GSA4098-9780,-9792,-9793, and-9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Models 4098-9775, -9776, -9777,-9780,-9780E, -9789, -9789E, 9789TSP, -9789TTP, -9791, -9791E,-9791TSP, 9791TTP,-9792, -9792E, -9792TSP, 9792TTP, -9793, -9793E, -9793TSP, -9793TTP; GSA4098-9780, -9792 and-9793 are intended for use with: Models 4098-9714 and GSA4098-9714 photoelectric smoke detectors(CSFM Listing No. 7272-0026:0218); Model 4098-9717 ionization smoke detector(CSFM Listing No. 7271-0026:0231); and Models 4098-9733, GSA4098-9733,4098-9734 and GSA4098-9734 heat detectors(CSFM Listing No. 7270-0026:0216). Models 4098-9796, -9796TSP, -9796TTP, GSA4098-9796 are only intended for use with Models 4098-9754 or GSA4098-9754 photoelectric smoke detector(CSFM Listing No.7272-0026:0218). These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required,the sounder/base unit must be used with the control unit that can produce the temporal pattern. Refer to listee's Installation Instruction Manual for details. `Rev.02-08-18 gt %—rf-, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed O` the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division