HomeMy WebLinkAbout49MTV-APPLW DATASHEET ( AUTO CALL TrueAlert Addressable Notification Appliances UL, ULC Listed* Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone and multi-candela •,, TrueAlert ES A/V(audible/visible)notification appliances provide: • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with s -- intensity programmable from the control panel or jumper selected as t. 15,30,75,110,135,or 185 cd Yi . •Advanced addressable notification controlled by IDNAC SLCs providing FIRE pe I regulated 29 VDC allowing strobes to operate with lower current even under battery backup • Wiring supervision to each appliance allowing"T-tapped"connections l �; for Class B circuits to simplify wiring(Class A circuits require in/out wiring) • Self-Test Mode allows on-board sensors to detect the strobe and horn FIRE output and then report their status to the control panel • Per appliance tone selection of:520 Hz Horn,Broadband Horn,Bell, Fig 1:TrueAlert ES Multi-Tone Chime,High/Low,Slow Whoop,or Siren;programmable from the Addressable A/Vs are Available control panel,or selected using an on-board DIP Switch(refer to Table in Red with White Lettering 9) and White with Red Lettering • 520 Hz tone is compliant with NFPA 72 Low Frequency Signal Requirements for Sleeping Areas Description • Horn,Bell,and High/Low tones can be controlled as:Temporal Code TrueAlert ES addressable multi-tone ANs 3,Temporal Code 4,March Time(selectable as 20,60,or 120 bpm),or TrueAlert ES addressable multi-tone A/Vs are individually addressed aud- Continuous ible/visible notification appliances that receive power,supervision,and • Slow Whoop,Siren,and Chime tone selections are controlled as control signals from a Autocall fire alarm control panel providing IDNAC synchronized continuous operation Signaling Line Circuits(SLCs).(See IDNAC SLC Controller Compatibility • Output of"high"or"low"(-6 dBA difference)selectable at the Reference on page 5.) appliance or from the controller with FACP mode selected at the Strobe Application Reference appliance Proper selection of visible notification is dependent on occupancy, • TrueAlert Device Reports at the control panel detailing appliance point location,local codes,and proper applications of:the National Fire Alarm ID,custom label,type,and candela setting Code(NFPA 72),ANSI A117.1;the appropriate model building code: • Magnet Test diagnostics to assist checkout and testing of appliances BOCA,ICBO,or SBCCI;and the application guidelines of the Americans and wiring with Disabilities Act(ADA). • Electrical test point access without removing cover • Compatibility with ADA requirements;(refer to Installation Reference TrueAlert ES Operation Advantage on page 4) TrueAlert ES addressable appliances on IDNAC SLCs provide • Strobe operation is listed to UL Standard 1971 and ULC Standard separate visible and audible notification using a single two-wire circuit S526;Horn operation is listed to UL Standard 464 and ULC Standard that also confirms connection to the individual notification appliance's S525 electronic circuit.This operation increases circuit supervision integrity LED Indicator and Magnet Test feature: by providing supervision that extends beyond the appliance wiring •Appliance LED can be selected to display each polling cycle to indicate connections. appliance supervision Reduced current allows efficient IDNAC SLC operation.With IDNAC SLCs,a constant 29 VDC source voltage is maintained,even • When the controller is in diagnostic mode,the Magnet Test pulses the during battery standby,allowing strobes to operate at higher voltage LED to indicate appliance address and can be set to also briefly flash with lower current and ensuring a consistent current draw and voltage the strobe and sound the horn drop margin under both primary power and secondary battery standby. Mechanical design features include: Efficiencies include wiring distances up to 2 to 3 times farther than with • Rugged,high impact,flame retardant thermoplastic housing in red with conventional notification,or support for more appliances per IDNAC SLC, white letters or white with red letters,with clear lens,available with or use of smaller gauge wiring,or combinations of these benefits,all FIRE,ALERT,or blank lettering providing installation and maintenance savings with high assurance that • Separate covers are available to change application type on-site or appliances that operate during normal system testing will operate during for replacement;covers can be easily removed without disturbing the worst case alarm conditions. connected housing and avoiding trouble conditions Reducing Installation and Testing Time.With separate controls on •A separate mounting plate allows wiring to be completed before the same two-wire SLC,installation time and expense for both retrofit appliance is mounted;use with single gang,double gang,or 4-inch and new construction can be significantly reduced.When Class B wiring square box,flush or surface mount is used,wiring can be"T"tapped,allowing more savings in distance, • In/out wiring terminals for 18 AWG to 12 AWG wire,conduit(size and utilization),and overall installation efficiency.Use of Self-Test and Magnet Test features improve installation efficiency. • Optional mounting adapters are available to cover surface mounted TrueAlert device reports conveniently identify information about each electrical boxes and to adapt to Autocall,2975-9145 boxes connected appliance. *Additional listings may be applicable;contact your local Autocall product supplier for the latest status. AC49MTV-0001 Rev.6 7/2016 fiNAUTOCALL Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output TrueAlert ES Diagnostics Test Features.When IDNAC SLCs are in diagnostic mode,Self-Test and Magnet Test features provide individual appliance testing.With the Self-Test feature,appliance operation can be confirmed without leaving the control panel.Additionally,each appliance's LED can be selected to pulse when it receives a supervision poll during normal operation. Self-Test Details.Selecting Self-Test Mode from the control panel allows on-board sensors,depending on the device type,to detect its own strobe and/ or horn output and then report their status to the control panel.Operation is by selected VNAC appliance groups and is either automatic(all briefly simultaneously activated)or individually activated by applying a magnet.(Refer to control panel data sheet for more Self-Test information,see IDNAC SLC Controller Compatibility Reference on page 5.) Silent Appliance Magnet Test.In this test mode,in response to application of a magnet,the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Magnet Test.In this test mode,after the address is indicated by pulsing the appliance LED,the strobe will briefly flash and the horn will briefly sound to indicate proper operation. TrueStart Instrument Two(TSIT).The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs,NACs,and IDNet communications before connection to the control panel.Please contact your local Simplex representative for additional information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring.(See data sheet AC4905-0001.) Product Selection Table 1:TrueAlert ES Wall Mount Multi-Tone Addressable Audible/Visible Appliances SKU Cover Color Wording Lens Color TrueAlert ES multi-tone addressable A/V appliances include cover and matching mounting plate except as noted;Dimensions with Cover=5 Ys"H x 5" Wx2%"D(130mmx127mmx67mm) A49MTV-APPLW Select cover and mounting plate separately Table 2:TrueAlert ES Wall Mount Multi-Tone Addressable AudibleNisible Appliances SKU Color SKU Color Note A49MP-AWOWR Red A49MP-AWOWW White Mounting Plate,select color to match cover Note:(-BA)indicates model is available either with or without the-BA suffix.Model numbers ending in-BA,APPLW models,and separate mounting plates are assembled in the USA. Table 3:Separate Covers(Required when ordering model 49MTV-APPLW(-BA),uses same covers as A49AV Series fixed tone A/Vs) SKU Color Wording A49AVC-WRFIRE Red A49AVC-WWFIRE White FIRE A49AVC-WRALT Red A49AVC-WWALT White ALERT A49AVC-WRS Red Logos Only A49AVC-WWS White Logos Only Page 2 AC49MTV-0001 Rev. 6 7/2016 fiNAUTOCALL Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Table 4:Separate Covers(Required when ordering model 49MTV-APPLW(-BA),uses same covers as A49AV Series fixed tone A/Vs) SKU Color Wording A49AVC-WRFIRE Red A49AVC-WWFIRE White FIRE A49AVC-WRALT Red A49AVC-WWALT White ALERT A49AVC-WRS Red A49AVC-WWS White Logos Only Table 5:Mounting Adapters SKU Color Description Dimensions A4905-9937 Red 5%"Hx51/4"Wx15/a"D(136mmx133mmx41 mm)Total A4905-9940 White Surface Mount Adapter Skirt depth with strobe=4 3h"(111 mm) A4905-9931 Red Adapter Plate for mounting to Autocall,2975-9145 Box(typically 8 5/6"x 5 3/4"x 0.060"Thick(211 mm x 146 mm x 1.5 mm) for retrofit,mount vertical or horizontal) 2975-9145 Red Mounting Box,requires A4905-9931 Adapter Plate I7%a"x 51/8"x 2 3/4"D(200 mm x 130 mm x 70 mm) Page 3 AC49MTV-0001 Rev. 6 7/2016 fiNAUTOCALL Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Installation Reference Mounting is compatible with single gang, / ___Th __-Th (-m/> IMPORTANT!WALL MOUNT double gang,and 4"(102 mm)square boxes, ° INSTALLATION HEIGHT REFERENCE 1-1/2"(38 mm)deep,supplied separately _ _ / Wiring terminals and °(1_° °Ln �° i ° 0 connection clips Transparent A/V configuration switch -- _ /Electrical P 9 • —I< box outline housing assembly accessible from rear of 4, UP u 1 1 Removable cover(when housing(not shown) =��:� �(� � J installed,use flat bladed I yi O p J� _ screwdriver to release latch ,— ` ' • �' on left side) / p ` � / Bottom of lens is �1° either even with,or O ILJI me slightly above bottom pPm®wa®"4® \ �� of compatible boxes 0 s 1 0 0�7- .. Hi7/1 Wiring access I hole 80"(2.)3 m) LED indicator 1 C minimum Address setting DIP Location \ . -__________I/ Mounting plate NFPA 72 requires switch,accessible — —\` that the entire lens be from rear of housing Mounting Holes: not less than 80"and -►81�.�8 Single gang(2) not greater than 96" Magnetic test location Double gang(4) above the finished (bottom of housing) 110 4"square(4) floor(confirm with 305 .IIIIntensity your local codes) -- selection Strobe intensity plug,accessible viewing slot on � =i•I■IIII from rear of --- side of appliance aim. u housing;factory Electrical test point 1access holes (not to scale) 1185 setting is FACP, (on bottom) controlled by panel V , TrueAlert ES AN Specifications Table 6:Electrical specifications Typical Operating Voltage Range 23 VDC to 29.5 VDC,Special Application Electrical Supervisory Requirements 2 unit loads(1 unit load=0.8 mA control panel current) Ratings Up to 21 appliances can connect directly to the panel IDNAC SLC or to a 4009 IDNAC Repeater A49MTV Series SLC Loading output,to a maximum of 127 addresses and 139 unit loads per SLC IDNAC SLC Wiring Specifications(refer UTP,unshielded twisted pair recommended to control panel or power supply installation Maximum wire length allowed with"T-Taps"for Class B wiring per SLC=10,000 ft(3048 m) instructions for more information) Maximum wire length to any appliance=4000 ft(1219 m) Table 7:Tone Characteristics 520 Hz Horn 520 Hz tone Broadband Horn Combination 600/3000 Hz signal These tones are compatible with control panel Bell Synthesized Bell tone IDNAC commands for operation as Temporal Code 3, Temporal Code 4,March Time at 20,60,or 120 bpm, Hi h/Low Alternating modulated tones with fundamentals of 1000 Hz and 800 or Continuous operation g Hz,250 ms duration each Slow Whoop Modulated 520 Hz to 1200 Hz sweep with 2 s duration Siren Modulated 600 Hz to 1200 Hz to 600 Hz sweep,with 2 s duration These tones operate as Continuous with sync tones Chime Multi-phase signal with a peak and decay time of 1 s Table 8:TrueAlert ES Multi-Tone Horn/Strobe Current Ratings RMS Current Ratings @ 23 VDC,in mA 15 cd 30 cd 75 cd 110 cd 135 cd 185 cd Tone High Low High Low High Low High Low High Low High Low 520 Hz Horn and High/Low 145 108 163 125 198 158 230 195 262 214 299 257 Page 4 AC49MTV-0001 Rev. 6 7/2016 fiNAUTOCALL Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Table 8:TrueAlert ES Multi-Tone Horn/Strobe Current Ratings RMS Current Ratings @ 23 VDC,in mA 15 cd 30 cd 75 cd 110 cd 135 cd 185 cd Tone High Low High Low High Low High Low High Low High Low Broadband Horn,Bell,Chime,Slow 135 99 152 111 185 139 212 172 247 203 284 243 Whoop,and Siren Table 9:TrueAlert ES Multi-Tone Horn/Strobe Horn Output UL 464 Output Ratings @ 23 VDC and 29.5 VDC(dBA)* ULC S525 Output Ratings @ 23 VDC and 29.5 VDC(dBA)* Steady High Steady Low Coded High Coded Low Steady High Steady Low Coded High Coded Low Tone Voltage 23 29.5 23 '29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 23 29.5 520 Hz Horn 80 80 74** 75 76 76 70** 71** 83t 79t 83t 78t High/Low 81 82 77 77 75 76 70** 71** 87 82t 86t 82t Broadband Horn 84 84 79 79 81 81 74** 75 88 84t 87t 83t Bell 80 80 75 75 76 76 71** 71** 85 80t 85t 80t Slow Whoop 79 80 74** 75 85 80t Siren 79 80 74** 75 these tones are not used for 85 80t these tones are not used for Chime** 67** 67** 62** 62** coded operation coded operation 82t 77t *Output ratings are at 10 ft(3 m);UL 464 ratings are per UL Reverberant Chamber testing;ULC S525 ratings are per ULC Anechoic Chamber testing. The tone generator circuit is DC-DC converter powered and provides essentially constant output over the rated voltage range. **UL output ratings below 75 dBA are for NFPA 72 Private Mode applications. t ULC output ratings below 85 dBA are for use in applications per applicable local codes. Table 10:Sound Output Dispersion per ULC 5541 Anechoic Testing Horizontal -3 dBA @±37° -6 dBA @±40° 9.4 dBA @±90° Vertical -3 dBA @-24°,+42° -6 dBA @-59°,+50° -8.6 dBA @±90° Table 11:General Specifications Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%,non-condensing @ 104°F(40°C) Connections Terminal blocks on mounting plate for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Installation Instructions 579-1156AC for A49MTV Series AN appliances 579-1100AC for A49MP Series mounting plates IDNAC SLC Controller Compatibility Reference Data Sheet I IDNAC SLC Output 'Appliance Voltage Compatible Controllers Reference Controller Output Voltage Design Reference 4100ES with EPS+or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 23 VDC 4007ES with IDNAC Notification AC4007-0002 IDNAC SLC 29 VDC(regulated) (with 6 VDC drop) 4010ES with ESS Enhanced System Supply AC4010-0011 Page 5 AC49MTV-0001 Rev. 6 7/2016 ( AUTOCALL ©2017 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC49MTV-0001 Rev.6 7/2016