Loading...
HomeMy WebLinkAbout49AV-APPLC DATASHEET ( AU TO CALL TrueAlert ES Addressable Notification Appliances UL, ULC,CSFM Listed* Audible/Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/ Strobe,Model Series A49AV Description Audible notification appliance (horn): Ceiling Mount Addressable Visible(A/V)Notification Appliances • Harmonically rich output sound for either coded or steady operation are individually addressed audible/visible notification appliances that • Horns sound as Temporal Code 3,March Time pattern,continuous;or receive power,supervision,and control signals from an Autocall fire Temporal Code 4,controlled separately from visible appliances on the alarm control panel providing IDNAC Signaling Line Circuits(SLCs).LED same two-wire circuit and Xenon tube strobes devices are interoperable on the same IDNAC • Selectable March Time rates of 20,60,or 120 beats per minute channel.(See TrueAlert ES AN LEGACY Compatibility Reference.) • Output is"high"or"low"(-5 dBA difference)selectable at the appliance or from the controller with FACP mode selected at the appliance Features Individually addressed and controlled multi-candela TrueAlert ES A/V(audible/visible)notification appliances provide: • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15,30,75 or 110cd on the AV model,or 110,135 or 185 cd on the AVHmodel •••••••••••••••••••• •Advanced addressable notification controlled by IDNAC SLCs. • IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current • Wiring supervision to each appliance allowing'T-tapped"connections •�'��� . for Class B circuits to simplify wiring(Class A circuits require in/out wiring) " ' I • Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel :.__ ` �. • TrueAlert Device Reports at the control panel detailing appliance point ID,custom label,type,and candela setting(see sample in TrueAlert Device Reports Reference) Figure 1: TrueAlert ES Addressable A/V • Magnet Test diagnostics to assist checkout and testing of appliances and wiring Strobe Application Reference • Electrical test point access by removing the cover Proper selection of visible notification is dependent on occupancy, • Compatibility with ADA requirements;(refer to important installation location,and local codes. information in Installation Reference) • Compatibility with legacy TrueAlert addressable systems for upgrade TrueAlert ES Operation Advantage and replacement(see TrueAlert ES AN LEGACY Compatibility Reference) TrueAlert ES addressable appliances on IDNAC SLCs • Strobe operation is listed to UL Standard 1971 and ULC Standard provide separate visible and audible notification using a single two 5526;Horn operation is listed to UL Standard 464 and ULC Standard wire circuit that also confirms connection to the individual notification S525 appliance's electronic circuit.This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance LED Indicator and Magnet Test feature: wiring connections. •Appliance LED can be selected to display each polling cycle to indicate Reduced current usage on IDNAC SLCs appliance supervision With IDNAC SLCs,a constant 29 VDC source voltage is maintained,even • When the controller is in diagnostic mode,the Magnet Test pulses the during battery standby,allowing strobes to operate at higher voltage LED to indicate appliance address and can be set to also briefly flash with lower current and ensuring a consistent current draw and voltage the strobe and sound the horn drop margin under both primary power and secondary battery standby. Mechanical design features Efficiencies include wiring distances up to 2 to 3 times farther than with • Rugged,high impact,flame retardant thermoplastic housing in red with conventional notification,or support for more appliances per IDNAC SLC, or use of smaller gauge wiring,or combinations of these benefits,all white letters or white with red letters,with clear lens,available with providing installation and maintenance savings with high assurance that FIRE,FEU,ALERT,FEU/FIRE,or blank lettering appliances that operate during normal system testing will operate during • Separate covers are available to change application type onsite or for worst case alarm conditions. replacement •You can use a back box to mount the appliance assembly to the wall. Reducing Installation and Testing Time Mount to a 4-inch(10.16 cm)square electrical box With separate controls on the same two-wire SLC,installation time and • Covers can be easily removed without disturbing the connected expense for both retrofit and new construction can be significantly housing and avoiding trouble conditions reduced.When Class B wiring is used,wiring can be"T"tapped,allowing more savings in distance,wire,conduit(size and utilization),and overall • In/out wiring terminals for 18 AWG to 12 AWG installation efficiency.Use of Self-Test and Magnet Test features improve • Optional red wire guards(see Product Selection) installation efficiency.TrueAlert device reports conveniently identify information about each connected appliance. *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listings 7125-2269 0520,7300-2269.0553 and 7125-0026:0380 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable;contact your local Autocall product supplier for the latest status. AC49AVC-0001 Rev. 8 01/2020 •AUTOCALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV TrueAlert ES Diagnostics Test Features When IDNAC SLCs are in diagnostic mode,Self-Test and Magnet Test features provide individual appliance testing.With the Self-Test feature,appliance operation can be confirmed without leaving the control panel.Additionally,each appliance's LED can be selected to pulse when it receives a supervision poll during normal operation. Self-Test Details Selecting Self-Test Mode from the control panel allows on-board sensors,depending on the device type,to detect its own strobe and/or horn output and then report their status to the control panel.Operation is by selected VNAC appliance groups and is either automatic(all briefly simultaneously activated)or individually activated by applying a magnet.(Refer to control panel data sheet for more Self-Test information,see list in Table 10.) Silent Appliance Magnet Test In this test mode,in response to application of a magnet,the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Magnet Test. In this test mode,after the address is indicated by pulsing the appliance LED,the strobe will briefly flash and the horn will briefly sound to indicate proper operation. TrueStart Instrument Two(TSIT) The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs,and IDNet communications before connection to the control panel.Please contact your local Autocall representative for additional information. TrueAlert Addressable Wiring Isolator Isolator Model A4905-9929 Isolator Model A4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (See data sheet AC4905-0001.) Installation Reference Appliance with cover(front) Appliance(rear) Mount to 4"X 4"X 1-1/2" o o Magnet test location electrical box using 8-32 o.. indicated by area that screws / /§ , is not textured Note:Ceiling mount only i (um I D❑ I PUpp00000�ANt ,�l °Opp00000009e O0°O I� J� O \ 1 i ` 0 0 0°0°°0°00°000°0 s°o°o •\ f°� ; oo°oc°o°o°a.00°0000 o°o°m°o°o � ,�I�,�D,�I�,�D, a i `�i o°o°0.000°° 00o°°oo°0000°o°o o°o°o°o _ 000000°°°°000°°°°°°°m°° 1 1 , 0000000000-0000000000000 Appliance testpoints, 0000000000000000000000000 PP 1 000000000000000000000000 power ,audio circuit taps, , 00000000000 0 p0 0 0 0000000 Am P P ; , 0 00000 0°o°°°°°000 0 0°0°°°00°0° and address dip switch , 000°o°ooa 000°oo°o 000°o°o° ° °(./. Set audio circuit power taps and `. °o°o°oa o°o°a°o°o°00°0 0 0 0° device address before fixing °°oo 0o a eee o)00°° 0 O cover in place. %'- --II II IN - Candela flag setting Wiring terminals for horn Ymr ® and strobe connections +rm *' Awir Set flag to FACP to control i I accept 2#12-18 AWG wires o.,.m...- candela rating from an FACP . . ` providing IDNAC notification. -- ` , ' I To set candela manually,set i 110s` _ _ _ -. •• ..-. - . .. - the flag to the desired ; 75 candela rating. 75 Use slotted screwdriver FACP , here to remove cover. TrueAlert Device Reports Reference Service Port Page 1 REPORT 5 : TrueAlert Device Report 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/0 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 135 Page 2 AC49AVC-0001 Rev.8 01/2020 •AUTOCALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV Product Selection Ceiling Mount Addressable AudibleNisible(AN)Appliances TrueAlert ES Addressable AN appliance dimensions with cover:8'/8"H x 7/8"W x 3"D(206 mm x 180 mm x 76 mm) Table 1:Ceiling Mount Addressable Audible-Visual Only AN Appliances (SKU* Lens color (Description Installation Instructions A49AV-APPLC Clear AV appliance only.Select cover 579-1242AC A49AV-APPLC-BA separately. A49AVH-APPLC A49AVH-APPLC-BA A49AVH-APPLCA-BA (Amber A49AVH-APPLCB-BA (Blue (Pending) (Green (Pending) 1Red Table 2:Back boxes SKU 1Color A49WPBB-SVCR I Red A49WPBB-SVCW (White Note:Use WP back boxes for surface mounting only.Using weatherproof back boxes does not make an appliance weatherproof. Table 3:Separate Covers(Required when ordering model 49AV-APPLC(-BA)) SKU* Color Wording A49AVC-C RFI RE Red RE A49AVC-CWFIRE White A49AVC-CRALT Red (ALERT A49AVC-CWALT White A49AVC-CRBAA Red )1a31/ALERT A49AVC-CWBAA White A49AVC-CRS Red Autocall logo only A49AVC-CK Black Blank A49AVC-CRFEU Red FEU A49AVC-CWFEU White A49AVC-CRBAF Red A49AVC-CW BAF White Lg?}>/FIRE A49AVC-CRBF Red FEU/FIRE A49AVC-CWBF White A49AVC-CWS White Autocall logo only A49AVC-CWCALT White I" /FIRE Table 4:Wire Guards and Wire Guard Back Boxes SKU ' (Description A49WG-SVWCR IAV Ceiling Mount Red Wire Guard A49WGBB-SVCR-O 1AV Ceiling Mount Red Wire Guard Back Box Page 3 AC49AVC-0001 Rev.8 01/2020 •AUTOCALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV TrueAlert ES AN Specifications Table 5:Electrical Ratings Specification Rating Typical Operating Voltage Range 23 VDC to 30 VDC,Special Application Supervisory Requirements 11 unit load(=0.8 mA control panel current) IDNAC SLC Loading 1Maximum of 127 addresses per SLC Table 6:Sound Output Ratings @ 10 ft(3 m)(with IDNAC SLCs) Sound Type/Setting Voltage Steady/High Steady/Low Coded/High Coded/Low Reverberant Chamber, 23 89.0 dBA 83 dBA 85 dBA 80 dBA UL 464 Test 131 191 dBA 185.5 dBA 187 dBA 182 dBA Anechoic Chamber,ULC I23 197 dBA 192.5 dBA 197 dBA 192.5 dBA 525 Test 131 199 dBA 195 dBA 199 dBA 195 dBA Table 7:Maximum RMS operating current 49AV Visible �49AVH Visible it Candela 23-30 VDC Current 17-31 VDC Current Candela ICD amber dome ICD blue dome CD clear dome Current 15 167 mA 184 mA - - - 30 192 mA 1119 mA 95 175 110 300 mA 75 1159 mA 1214 mA 110 195 135 330 mA 1110 1215 mA 1279 mA 135 1110 185 391 mA IUL rated only IAO:17 V or 23 V rating 18 mA Table 8:General Specifications Specifications Ratings Sound Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Temperature Range I32°to 120°F(0°to 49°C) Humidity Range 110%to 93%,non-condensing @ 104°F(40°C) Connections Terminal blocks on mounting plate for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring IDNAC SLC Wiring Specifications(refer to control panel installation IUTP,unshielded twisted pair recommended instructions for more information) Maximum wire length allowed with'@-Taps"for Class B wiring per SLC= 10,000 ft(3048 m) (Maximum wire length to any appliance=4000 ft(1219 m) Note:UL 464 test coded values are typical of the output measured with a Temporal or a March Time pattern and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher.Anechoic horn output rat- ings are typically more representative of actual installed sound output. IDNAC SLC Controller Compatibility Reference Table 9:Compatibility Reference Data Sheet IIDNAC SLC Output lAppliance Voltage Compatible Controllers Reference Controller Output Voltage Design Reference 4100ES with EPS+or EPS Power Supply AC4100-0100 4009 IDNAC Repeater AC4009-0004 IDNAC SLC 29 VDC 23 VDC 4007ES with IDNAC Notification AC4007-0002 I (regulated) (with 6 VDC drop) 4010ES with ESS Enhanced System Supply AC4010-0011 TrueAlert ES AN LEGACY Compatibility Reference Table 10:Compatibility Reference Compatible Data Sheet Reference Controller Output Available Strobe Appliance Voltage Controller Intensity Minimum 4100ES with TrueAlert AC4100-0031 TrueAlert Addressable 15,30,75,and 110 cd Continuous,Temporal 17 VDC Power Supply SLC Code 3,and March Time 4009 TPS,Remote AC4100-0037 of 60 or 120 bpm TrueAlert Power Supply* TrueAlert Addressable AC4009-0003 Controller(4009T)* Electrical Ratings Differences for Legacy Applications(refer to above specifications for other ratings) Page 4 AC49AVC-0001 Rev.8 01/2020 •AUTOCALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV Table 10:Compatibility Reference Compatible Data Sheet Reference Controller Output Available Strobe Appliance Voltage Controller Intensity Minimum Voltage Range 17 VDC to 31 VDC,Special Application Sound Output Ratings Sound Type/Setting (Steady/High Steady/Low Coded/High Coded/Low @ 10 ft(3 m)@ 17 VDC Reverberant Chamber, 87.0 dBA 81.0 dBA 82.0 dBA 77.0 dBA UL 464 Test Anechoic Chamber,ULC 94.5 dBA 90.0 dBA 94.5 dBA 90.0 dBA 525 Test Candela Setting 115 cd 30 cd 75 cd 110 cd 17 VDC RMS Current Ratings,with horn on 74 mA 85 mA 140 mA 185 mA continuousat high setting,use when connected to TrueAlertAddressable SLCs per above *Not compatible with A49AVH-APPLC.For connection to legacy fire panel models Simplex 4009T and 4100/TPS.High candela(49AVH)appliances are not compatible with Simplex models 4009T and TPS,see the fire panel compatibility charts. Page 5 AC49AVC-0001 Rev.8 01/2020 •AUTOCALL AudibleNisible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn/Strobe,Model Series A49AV ©2020 johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC49AVC-0001 Rev.8 01/2020