Loading...
HomeMy WebLinkAbout4606-9202 DATASHEET ( AU TO CALL System Accessories, LCD Annunciators UL, ULC,CSFM Listed* A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Features Description Local Annunciation and Control A4606-9202 and A4606-9205 Series LCD Annunciators allows 4007ES fire alarm control panels to provide information and control switches at ta convenient locations away from the control panel.The color touchscreen Boy • LCD with backlighting displays information in clear and descriptive language.(English is standard,other languages can be programmed.) " Typical content includes:point status(alarm,trouble,etc.),alarm type (smoke detector,manual station,etc.),number of system alarms, supervisory conditions,troubles,and custom location labels up to 40 characters long. Figure 1: A4606-9202 LCD Annunciator with Red Trim Communications ®® Data communications require a single unshielded twisted pair that supports other annunciators on the same communications channel. iIndications Alarm,Priority 2,Supervisory,Trouble,and Alarm Silenced conditions are ndicated by dedicated LEDs and a tone alert audible indication.Each condition will cause the display to present a dedicated acknowledge 0 push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Custom Background Figure 2: A4606-9205 LCD Annunciator with Platinum Trim The 4007ES control panel supports a custom background image that is also displayed on each of the color touchscreen annunciators when Remote Color Touchscreen LCD annunciators for use with status is normal.File types supported are JPG,BMP,GIF,and PNG. Autocall model 4007ES fire alarm control panels Recommended image type is JPG,recommended image size is 480 x 4.3"(109 mm)diagonal color touchscreen display: 240,and the file size limit is 100 kb. • Provides the display features of the 4007ES fire alarm control panel at Operation a remote location • Convenient and intuitive user interface provides detailed system status Keyswitch Access and individual point information Touchscreen display access can be controlled by a keyswitch with a key • LED status indicators include Alarm,Priority 2,Supervisory,Trouble, that is removable only in the disabled position.Access is configurable Alarm Silenced,and Status of AC Power at the control panel per annunciator. • Supports dual language selection,including unicode character Enabled Operations languages When the keyswitch is on,system status indications will be displayed • Keyswitch is used to enable default access level;additional user access as they occur with individual point detail as programmed at the control levels are passcode protected;keyswitch and user access levels are panel,and soft keys will be displayed to allow user actions. configurable •Tone-alert sounder provides local audible indication Screen Backlight •Three programmable control switches with status LEDs and provisions When the display has not been touched,and no new system status for custom labeling has occurred for 60 seconds,the backlight dims to 20%of normal brightness.If there is no activity in the system(System is Normal), Additional features: the standby screen displays current time and date to verify proper •Available with platinum or red trim operation.If an event occurs,or with the keyswitch activated,and the • Information is transmitted over a single unshielded twisted pair; screen is touched,the backlight returns to full intensity separate wiring is required for 24 VDC power Lamp Test • Mounts flush on RACO 944,5-gang electrical box(supplied separately) The display menu provides a lamp test feature that when selected, • Up to 6 Color Touchscreen LCD Annunciators per 4007ES fire alarm activates the 9 panel LEDs for 5 seconds.Dual-color LEDs will blink control panel alternately. Mounting box options(ordered separately): • Surface mount boxes in red or platinum • Semi-flush mount boxes in red or platinum,may be used for legacy annunciator retrofit applications *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listings 7300-2269 0559 and 7300-2269:0567 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable;contact your local product supplier for the latest status. AC4606-0003 Rev.3 01/2020 ( AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Product Selection Table 1:Annunciator Product Selection SKU Color Description Dimensions A4606-9202 Red Annunciator:13"W x 5.21"H x 2"D Remote Color Touchscreen LCD Annunciator;for flush mounting in a 5-gang (330 mm x 132 mm x 51 mm) RACO 944 box,or equal,supplied separately RACO 944 Box(reference):12 Ya"W x A4606-9205 Platinum 4/z"H x 21/2"D(311 mm x 114 mm x 64 mm) A2975-9461 Red 12 Ya"W x 4 Y"H x 21/2"D(311 mm x A2975-9462 Platinum (Surface mount metal box for above annunciators 114 mm x 64 mm) A2975-9463 Red (Semi-flush mount metal box adapter for above annunciators;use for 12 /a"W x 4 Yz"H x 1 3/a"D(311 mm x A2975 9464 Platinum mounting on existing 2-gang,4-gang,6-gang,or 4"(102 mm)square flush 114 mm x 44 mm) mounted boxes Note:SKUs ending with BA are assembled in the USA. Table 2:Suppression Products SKU Description Additional Reference A2081-9044 Overvoltage Protector,rated for up to 200 mA;use for RUI communications Data Sheet AC2081-0016 A2081 9028 Isolated Loop Circuit Protector(ILCP),rated for 5 A maximum;use for 24 VDC power wiring Data Sheet AC2081-0008 when above 200 mA Note:Suppression is required where annunciator communications and power wiring exits and enters a building. Operator Information 3 Programmable LEDs with Custom Label Insert and Optional Programmable Touchscreen Control Keys per LED;top two selectable as Red or Yellow, bottom selectable as Green or Yellow;for dual language,one of the control keys Color Touchscreen LCD with can be programmed to toggle between languages(insert is blank,labels shown Local Sounder( sample Main Menu showing are for reference) Custom ]� Control Keys Main Menu ` May 27,2015 DRILL ®1=1 I Trouble LOB( DRILL ® DRILL IC• To le Lan ua a Francais 000 ®® DlaBeeaB� 99 9 9 000° I OD Ground Fault (not programmed) pegg Lev I • 1 1 Cam, 1(0 (t) s • 4 • O • \ \ \ Alarm Indicator Supervisory Alarm Silenced Control Enable Keyswitch red LED Indicator yellow LED yellow LED controls all switch functions; key is removable only in Priority 2 Indicator Trouble Indicator AC Mains Power Status at disabled position red LED I f yellow LED J I Control Panel green LED Page 2 AC4606-0003 Rev.3 01/2020 •AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Operator Screen Reference Main Menu FIRE ALARM IN SYSTEM SEP 28, 2014 9:04AM B OUIT N f Most Recent of 2 ZN2 SEP 1S, 2014 0:53 AM p —. System Info Panel Setup1141) Trouble Log A First Floor Hallway ® ZONELIST POINT FIRE ALARM Ir Hardware BUTTON System Reset I Reset Diagnostics OTTU B First of 2 ZN1 SEP 18, 2014 8-53 ANT- First Floor,Main Lobby (User Access ' ' BUTTON ZONELIST POINT FIRE ALARM Level Lamp Test Report Menu C l - - ti 1 In at= illii Figure 3: Main Menu Screen provides easy Figure 4: System Alarm Screen identifies active alarms with navigation to the function required. Buttons custom labels displayed,arrows allow navigation through the list A, B,and C have programmable functions. TROUBLE IN SYSTEM SEP 1S,2014 4:05 AM r Most Recent of 2 M1-4.0 SEP 18,2014 9:05 AM M1-2 PULL STATION I[RI HEAT DETECTOR DISABLE TROUBLE First Floor Hallway I DEVICE ADDRESS: 2-2 TYPE: AORPUL IDNET2 CARD '_ 11 UNIT NUMBER: 0 RUI NUMBER: LOCAL of First 2 P34 SEP 18,2014 9:04 AM PRIMARY STATUS FIRE ALARM CITY DISCONNECT CURRENT DEVICE CORRECT DEVICE TROUBLE POINT — ABNORMAL J DEVICE ON-LINE PHYSICAL STATE ABNORMAL RAW STATE ABNORMAL IS 110 Alarm ACTI VE STATE D, IL: L. Functlans110 ARMED STATE OEAR 7E ENABLED STATE ENABMg LED `i R lllrnrcrrn n_ _,- Figure 5: System Trouble Screen identifies active troubles with Figure 6: Point Information Screen allows review of point custom labels displayed,arrows allow navigation through the list details,arrows allow navigation through the information. Page 3 AC4606-0003 Rev.3 01/2020 •AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Specifications Table 3:General Operating Specifications Specification Rating Voltage 18 to 32 VDC,system supplied (Condition Current Details Current Details Alarm 124 mA Backlight at full intensity and tone-alert sounding Display Active 70 mA Backlight at full intensity,occurs when activity is in process (Standby 45 mA Backlight dimmed to 20%of full intensity,occurs after 1 minute of no system activity Operating Temperature Range 32°to 120°F(0°to 49°C) Operating Humidity Range Up to 93%RH,non-condensing at 100°F(38°C) Table 4:Communications Specification Description For 4007ES Panels Type RUI(Remote Unit Interface)external annunciator communications line SLC(signaling line circuit) Capacity 1Up to 6 Color Touchscreen LCD Annunciators Table 5:Wiring Requirements Specification Description Standard Wiring Type Unshielded twisted pair(UTP),18 AWG(0.82 mm2)for most applications,see below Wiring Characteristics 10.58 pE(580 nF)maximum capacitance between conductors;35 S2 maximum total line resistance Wiring that leaves the building.RUI wiring also requires A2081-9044 Overvoltage Protectors on each end. Wiring Applications Requiring Wiring run in 500 ft(152 m)or more of conduit. RUI Data Shielded,Twisted Pair(STP) Wiring closely bundled with standard IDNet communications or TrueAlert addressable communications (not required when run with IDNet+communications). Class B"T-Tap"wiring Up to 10,000 ft(3048 m)total wiring;up to 2500 ft(762 m)to farthest device distance Class X wiring distance IUp to 2500 ft(762 m) Power Wiring (Terminals for 18 to 12 AWG(0.82 mm2 to 3.31 mm2)wires for 24 VDC system power Earth Wiring A dedicated earth ground connection to the electrical box is required for proper ESD and EMI protection; wire in accordance with NFPA 70(National Electrical Code)Article 250 Table 6:Mounting Information Item Description Boxes for Flush Mounting(supplied 5-gang masonry box,RACO#944,2 Y"(64 mm)deep or equal separately) Table 7:Additional Reference Reference Description Installation Instructions 579-1172AC 4007ES Data Sheets IAC4007-0001,4007E5 Hybrid IAC4007-0002 Page 4 AC4606-0003 Rev.3 01/2020 ( AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels Mounting Information Surface Mounting:Use Surface Mount Box 2-1/2"deep(64 mm)(ordered separately) Flush Mounting:Use 5-gang RACO 944 box or equal,2-1/2"deep(supplied separately) o _01 LCD Annunciator Assembly • lO Trim Plate(supplied) Figure 7: LCD Annunciator Mounting Information Note: • For surface mounting,use Autocall Surface Mount Box Model A2975-9461 (red)or A2975-9462(platinum),2-1/2"deep(64 mm)(ordered separately). • For semi-flush mounting,use Autocall Semi-Flush Box Adapter Model A2975-9463(red)or A2975-9464(platinum),1-3/4"deep(44 mm)(ordered separately);use for mounting on existing 2-gang,4-gang,6-gang,or 4"square flush mounted electrical boxes(supplied separately). Wiring Reference lllllllllllllllllllllllll lll111llllllllllllllllllmlllul `= S To other RUI devices . 0 says; 0 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII, 4007ES Fire Alarm Control Panel LCD Annunciators Wiring Reference shows A4606-9202 LCD Annunciators. Note: Interconnection Wiring • Communication requires 18 to 12 AWG unshielded twisted pair. • Power requires two,18 to 12 AWG wires for 24 VDC system power,plus earth ground to each electrical box. • Refer to Install Instructions 579-1172AC for additional wiring specifications. Page 5 AC4606-0003 Rev.3 01/2020 •AUTOCALL A4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels ©2020 johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC4606-0003 Rev.3 01/2020