4090-9051 DATASHEET
( AUTOCALL Multi-Application Peripherals UL, ULC,CSFM Listed* IDNet Communicating Devices, Individual Addressable Modules(IAMB) Features IDNet addressable communications supply both data and power ( ____ over a single wire pair to provide** • Supervised Class B monitoring of normally open,dry contacts •Total wiring distance from IAM to supervision resistor(s)of up to 500 ft 'ERVISED IAM O (152 m) INOR.514-331 • Monitored connection is compatible with Autocall A2081-9044 DATE CODE Overvoltage Protectors for outdoor wiring or electrically noisy 12I 1.ieNETI w. 14 vecEp y, applications / • For use in indoor locations up to 158°F(70°C)such as attic spaces or similar applications ppppppppl For use with following Autocall control panels • Model Series 4007ES,4010ES,and 4100ES fire alarm control panels for IDNet communications Figure 1: A4090-9001 Supervised IAM Model A4090-9001 • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box • Screw terminals for wiring connections •Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation(requires mounting bracket,ordered separately) Model A4090-9051 C( • Encapsulated design for extended exposure to high humidity(LED is I b0. I.1S,Eo not present on this model) Il SIGNA�yG OE VICE �SSI¢NO. • Color coded 18 AWG leads for wiring v IDNet communications provides current limited monitoring • Provides monitoring of tamper switch(supervisory)and waterflow Figure 2: A4090-9051 Supervised IAM switch(alarm)on same circuit using one point •Available with IDNet communications only Operation Multiple operation modes are available and are selectable at the Contact Closure control panel Closure of the monitored contact(s)initiates an alarm or other response • Contact closure status can be tracked as programmed at the fire alarm control panel.An open in the • Momentary contact closure conditions can be selected at the panel to monitored circuit wiring will cause a trouble to be reported. be latched or tracked,UL listed to Standard 864 Panel Selections UL listed to Standard 864 Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary,such as from a rate-of-rise heat detector,or to track the device contact status. Description Current Limited Operation Applications Individual addressable modules(IAMB) For use with IDNet communications only,these IAMB can provide quad- receive both power and communications from a two-wire IDNet circuit. state sensing of normal,open circuit,short circuit,and current limited They provide location specific addressability to a single initiating device conditions.(Program type is"T-sense.")With the proper end-of-line and (such as single station smoke detector alarm contacts or heat detector current limiting resistors,dual functions such as tamper switch and contacts)or multiple devices at the same location by monitoring waterflow switch monitoring can be determined and communicated by a normally open dry contacts and the wiring to an end-of-line resistor. single addressable point. SKU A4090-9001 A4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. SKU A4090-9051 A4090-9051 is an encapsulated package with wire leads.It does not provide a status indicating LED. *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listings 7300-2269 0507 and 7300-2269:0567 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable;contact your local product supplier for the latest status. AC4090-0001 Rev. 13 1/2020 •AUTOCALL IDNet Communicating Devices, Individual Addressable Modules(IAMB) IAM Product Selection Table 1:IAM Product Selection SKU Description A4090-9001 Supervised IAM,mounted in thermoplastic housing with screw terminals;see applicable options below A4090-9051 (Supervised IAM,encapsulated with wire leads Table 2:Optional Trim Plates and Mounting Bracket for Model A4090-9001 SKU Description A4090-9806 For semi-flush mounted box Trim plate with LED viewing window, A4090-9807 For surface mounted box requires A4090 9810 mounting bracket, includes mounting screws;galvanized steel A4090 9810 Mounting bracket,mounts IAM to electrical box and provides screw holes for trim plate,required for optional trim plates Table 3:End-of-Line Resistor Harnesses(ordered separately as required) SKU Reference no. Description A4081-9004 733-886 6.8 kO),1/2 W;Standard end-of-line resistor harness for N.O.contact supervision A4081-9003 1733-896 4.7 kO,1/2 W Use for current limited monitoring A4081-9005 733-984 1.8 ko,1/2 W lapplications Specifications Table 4:Electrical Specification Rating Power and Communications IDNet,auto selected,1 address per IAM Input Requirements Normally open,dry contacts Wire Connections 1A4090-9001 Screw terminals for in/out wiring,18 to 14 AWG wire(0.82 mm2 to 2.08 mm2) 1A4090-9051 Color coded wire leads,18 AWG(0.82 mm2),8"long(203 mm) Reference Documents 1Installation Instructions 574-331AC for A4090-9001;579-572AC for A4090-9051 1Field Wiring Diagrams 842-073 for IDNet operation Table 5:Wiring Distances Specification Rating Distance from IAM to Contacts 500 ft(152 m)maximum without protectors 400 ft(122 m)maximum with A2081-9044 Overvoltage Protectors 2500 ft(762 m)maximum from fire alarm control panel Wiring Distance Reference per channel,IDNet Communication 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Table 6:Mechanical Specification Rating 1A4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm) Dimensions 1A4090-9051 11-9/16"W x 1-9/16"H x 9/16"D(40 mm x 40 mm x 14 mm) Housing Material,A4090-9001 1Black thermoplastic Encapsulation Material,A4090-9051 1Epoxy,beige 1Temperature Range 132°to 158°F(0°to 70°C);intended for indoor operation Humidity Range 1Up to 93%RH at 100°F(38°C) Page 2 AC4090-0001 Rev. 13 1/2020 ( AUTOCALL IDNet Communicating Devices, Individual Addressable Modules(IAMB) Mounting Information ® Field wiring shown IDNet supervised IAM for reference I • i tv„. Sp@rpm lAM �F usi i+ps vs-u opucoo[ — LED viewing port flu 'oou Single gang electrical ® box 2-1/2"(64mm) --- minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws,for use when LED is not required to be externally viewed(supplied by others) Figure 3: Mounting Reference,Single Gang Blank Cover Plate Note: Figure 3 shows A4090-9001 IDNet supervised IAM. Al • O) Lightpe or LED o ~ Lviewing 4-'./4" ® _ 4-'./2" (106 mm) (114 mm) DISCONNECT POWER DISCONNECT POWER BEFORE SERVICING BEFORE SERVICING `I l V 2-1/2" 2-13/16" ~(64 mm) 4 (72 mm)-111. Trim plate for Trim plate for Mounting semi-flush mounted box surface mounted box bracket,ordered separately Figure 4: Optional Trim Plates and Mounting Bracket for Visible LED Note: Figure 4 shows the following: • A4090-9806,Trim plate for semi-flush mounted box • A4090-9807,Trim plate for surface mounted box • A4090-9810,Mounting bracket,ordered separately Page 3 AC4090-0001 Rev. 13 1/2020 •AUTOCALL IDNet Communicating Devices, Individual Addressable Modules(IAMB) A4090-9051 Mounting Information Address setting is ® at rear of housing Encapsulated Supervised IAM �P'_ "--"tr-2-15.1)C-11 Single gang electrical box 2-1/2"(64mm) minimum depth (supplied by others) � R Single gang blank cover plate and mounting screws(supplied by others) Figure 5: A4090-9051 Mounting Information Note: Figure 5 shows a A4090-9051 Encapsulated Supervised IAM. ©2020 johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC4090-0001 Rev.13 1/2020