HomeMy WebLinkAboutA007-9201 DATASHEET ( AUTOCALL 4007ES Fire Control Units uL, ULC,CSFM Listed,FM,NYC 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Fire Dept Approved* Features with short circuit isolation for the IDNet+channel;each loop expansion module also provides an additional 75 addressable points to the IDNet +channel capacity for a total of up to 250 addressable points IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Software Feature Summary: 111 • Current and previous panel configuration are both maintained in on- board memory to allow easy selection of desired revision • An internal Ethernet service port is available for service computer conm cnf ,d Fire Control 40077. uploads;nections reporttoperfordownloadso,and system softwareupdates updates and • Internal USB interface allows a memory stick/thumb drive to store job revisions,update revised jobs and panel software,and save detailed system reports from the panel Optional modules and connections include: • Fire Alarm Network Interface Card for ES Net Peer-to-Peer network communications,supports either Class B or IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Class X operation alumni • Point or Event DACT assembly that is compatible with IP Communicators • Up to two additional IDNet+addressable device output loop Figure 1: 4007ES Panel Front View connections with 75 additional point capacity each Compatible with Autocall ES Net • Front mounted 48 LED annunciator with custom label inserts. Flexible standard combination of addressable initiation and • Dual Class A IDNAC Isolator(DCAI) addressable notification • Remote LED annunciator support through RUI(remote unit interface) communications port for use with unshielded,twisted pair wiring(UTP) 4.3 in.(109 mm)Diagonal color touchscreen display: • Eight Point Zone/Relay Modules individually selectable as IDC or relay • Convenient and intuitive user interface provides detailed system status rated 2 A @ 30 VDC(resistive) and individual point information • Alarm relays and auxiliary relays • Supports dual language selection,including unicode character • Dual RS-232 ports(for printer,PC annunciator or third party interface) languages • •A custom background display appears when operation is normal Truelnsight Remote Gateway • City connections,with or without disconnect switch Includes a 3 A IDNAC SLC(signaling line circuit)output power • 4003EC Voice Control Panels supply that provides enhanced power delivery to addressable • 4009 Series IDNAC Repeaters notification appliances: • Battery brackets for seismic area protection •A constant 29 VDC source voltage is maintained during alarm,even during battery operation,allowing strobes to operate at higher voltage General Mechanical: with lower current and ensuring a consistent current draw and voltage • Compact red or platinum cabinet for convenient surface or semi-flush drop margin under both primary power and secondary battery standby mounting;rated NEMA 1 and IP30 • Efficiencies include lower strobe currents,wiring distances up to two to three times farther than with conventional notification,support 4007E5 Listings reference: for more appliances per IDNAC SLC,and smaller gauge wiring.This • UL 864-Control Units,System(UOJZ);Control Unit Accessories, provides installation and maintenance savings,with high assurance System,Fire Alarm(UOXX);Control Units,Releasing Device Service that appliances will operate as normal during worst case alarm (SYZV) conditions • UL 2017-Emergency Alarm System Control Units(CO detection),(FSZI) • IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert • ULC-5559-Central Station Fire Alarm System Units(DAYRC) addressable notification appliances,and remote 4009 IDNAC • ULC-5527-Control Units,System,Fire Alarm(UOJZC);Control Unit Repeaters to extend power and wiring distance even farther and Accessories,System,Fire Alarm(UOXXC);Control Units,Releasing provide for up to 127 addressable notification appliances Device Service(SYZVC) • Power supply provides battery backup charging of up to 33 Ah;up to 18 Ah for cabinet mounted batteries and up to 33 Ah batteries for mounting in close-nippled remote battery cabinet Electrically isolated IDNet+addressable initiating device SIC: • Provides built-in short circuit isolation for monitoring and control of TrueAlarm analog sensors and IDNet communications devices;for use with either shielded or unshielded,twisted or untwisted single pair wiring;outputs are Class A or Class B • Standard panel SLC provides up to 100 addressable points;optional additional loop expansion modules provide an additional isolated loop *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listings 7120-2269 0546, 7300-2269:0553,7300-2269:0559,7272-2269:0537 and 7165-2269:0536 for allowable values and/or conditions concerning material presented in this document.NYC Fire Dept COA#6264.Additional listings may be applicable;contact your local Autocall product supplier for the latest status. AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Introduction Operator Screen Reference 4007ES Series Fire Detection and Control Units Main Menu Screen provides System Alarm Screen identifies 4007ES panels provide extensive installation,operator,and service easy navigation to the function active alarms with custom labels features with point and module capacities suitable for a wide range required.Buttons A,B,and C have displayed,arrows allow navigation of system applications.Panels can be configured for stand-alone or programmable functions. through the list. networked fire control operation.The convenient and intuitive color _ . touchscreen provides easy access for typical system response actions "'°i"" °°""' and for detailed system review or configuration updates with password === a BruFI44r Bottom, 0 ZONEUST POINT FIRE ALARM control to limit user access. =I= Brst Floor,Nam Lobey O IDNet+addressable initiation communications and IDNAC addressable al 20NELI5T POINT FIRE'ARM notification communications are standard features.(Refer to data sheet ® 11111 �� AC4007-0001 for 4007ES panels providing conventional notification.) System Trouble Screen identifies Trouble Log Screen allows review ES panel compatibility with ES Net active troubles with custom labels of past troubles with time stamp Autocall ES Network(ES Net)is a next generation IP based fire network displayed,arrows allow navigation and point details shown. that uses industry standard network technology and infrastructure and through the list. 'Hull RI allows for simplified network upgrades,easy terminal connectivity and IP 'TROUBLE IN SYSTEM ' 1°',� 13 file transfer between nodes;and advanced network diagnostics. „ate _ NN,>M B Mo �_� 13 ES fire alarm control units can be upgraded to operate on an ES network I 'gav D,SgB, TR°.B, 0 , byadding an ES Net NIC to the panel. 412 P24 =EP18 2n„9o.AE ® ^�n.^.. ._— OrIY oISOONNEOT ®® For more detailed information on ES Net,consult datasheet ITROUBIEPOINT AB"°AM^` AC4100-0076,and talk to your local Autocall product supplier. ® 0 � Operator Interface Point Information Screen allows User Access Login Screen review of point details,arrows allow controls access to panel operations Convenient Status Information navigation through the information. as determined per panel. With the locking door closed,the glass window allows viewing of the display status LEDs.The user interface is a 4.3 in.diagonal color EatigliiiRM touchscreen LCD with separate status LEDs as shown below. ®N14 u ST�AT1oN O En BEYICE ADBRE5,2.2 E: RPUL Enter Paz* ®. IONET2 CMD ....� LED indicators describe the general category of activity being displayed UNIT NUMBER:B RBI NUMBER:LOCAL ® ®® PRIMARY STANS with the LCD providing more detail.For the authorized user,unlocking CRRENT DEVICE qWE DEVICEON• DOD PHYSDEVICAL STATE ABBNNO`RMAL the door provides access to the control functions and allows further ACTIVE SE ABNORMAALAIRED O O ACTIVE SE STATE inquiry by scrolling the display for additional detail. €STATE.. TE ENABLED limp Touchscreen Display with LED Status Indicators Operator Interface and Software Features FIRE ALARM IN SYSTEM • Convenient and detailed operator information is easily accessed using "°4AM a logical,menu-driven touchscreen display with password access Most Recent of ZN2 SEP 38.2014 8:53 AM 0 - control First Floor Hallway ZONELIST POINT FIRE ALARM [71 • Multiple automatic and manual diagnostics for maintenance reduction First Flour,Main Lobby 0 ul • Alarm and Trouble History Logs(up to 1000 entries for each,2000 total ZONELIST POINT FIRE ALARM jai events)are available for viewing from the display or for printing to a iii 1 . connected printer,or downloaded to a service computer r�l • Module level ground fault searching assists installation and service by ,i ill► I A 4 *, locating and isolating modules with grounded wiring • • 0 0 0 • • WALKTEST silent or audible system test performs an automatic self- resetting test cycle and supports up to eight WALKTEST groups • Install Mode allows grouping of multiple troubles for uninstalled Figure 2: Touchscreen Display with LED Status Indicators modules and devices into a single trouble condition(typical with future phased expansion);with future equipment and devices grouped into a single trouble,operators can more clearly identify events from the commissioned and occupied areas Page 2 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Mechanical Description CO sensor bases • Locking door with polycarbonate window CO sensor bases combine an electrolytic CO sensing module with a • Latching front panel assembly swings forward for convenient internal TrueAlarm analog sensor to provide a single multiple sensing assembly access using one system address.The CO sensor can be enabled/disabled, and can be used in LED/Switch modes and custom control.Refer to • Smooth box surfaces are provided for locally cutting conduit entrance AC4098-0052 for more details. holes exactly where required • Modules are power-limited(except as noted,such as relay modules) TrueAlarm heat sensors • Battery compartment(bottom)accepts two batteries,up to 18 Ah,to TrueAlarm heat sensors can be selected for fixed temperature detection, be mounted within the cabinet without interfering with module space; with or without rate-of-rise detection.Utility temperature sensing is also charger capacity is up to 33 Ah;for batteries greater than 18 Ah,refer available,typically to provide freeze warnings or alert to HVAC system to Module and Accessories Selection Information for external battery problems.Readings can selected as either Fahrenheit or Celsius. cabinet details TrueSense Early Fire Detection • Cabinet assembly design has been seismic tested and is certified to Multi-sensor A4098-9754 provides photoelectric and heat sensor data IBC and CBC standards as well as to ASCE 7 categories A through F, using a single 40070E5 IDNet+address.The panel evaluates smoke requires battery brackets as detailed on data sheet AC2081-0019 activity,heat activity,and their combination,to provide TrueSense early detection.For more details on this operation,refer to data sheet IDNet+ Addressable Device Control AC4098-0024. The 4007ES provides an IDNet+addressable initiating device Signaling Line Circuit(SLC)that supervises wiring connections and the individual Diagnostics and Default Device Type device communications status on the SLC.With two-wire IDNet+SLCs, initiation,monitoring,and control devices such as manual fire alarm Sensor Status stations,TrueAlarm sensors,control relays,and sprinkler waterflow TrueAlarm operation allows the control panel to automatically indicate switches can communicate their identity and status and receive fire when a sensor is almost dirty,dirty,and excessively dirty.The NFPA 72 alarm system control.Additional addressable interface modules include requirement for a test of the sensitivity range of the sensors is fulfilled circuit isolators,conventional IDC zone adapters,and interface to other by the ability of TrueAlarm operation to maintain the sensitivity level of system circuits such as fans,dampers,and elevator controls. each sensor.CO Sensors track their 10 year active life status providing indicators to assist with service planning.Indicators occur at:1 year,6 IDNet+Addressable Device Operation months,and end of life. Each addressable device on the IDNet+communication channel Modular TrueAlarm sensors is continuously interrogated for status condition such as:normal, TrueAlarm sensors use the same base and different sensor types(smoke off-normal,alarm,supervisory,or trouble.Both Class B and Class A or heat sensor)and can be easily interchanged to meet specific location operation is available.Sophisticated poll and response communication requirements.This allows intentional sensor substitution during building techniques ensure supervision integrity and allow for"T-tapping"of construction when conditions are temporarily dusty.Instead of covering the circuits for Class B operation.Devices with LEDs pulse the LED to smoke sensors(causing them to be disabled),heat sensors may be indicate receipt of a communications pot and can be turned on steady installed without reprogramming the control panel.The control panel from the panel.With addressable devices,the location and status of the will indicate an incorrect sensor type,but the heat sensor will operate at connected device is monitored,logged,and displayed on the operator a default sensitivity to provide heat detection for building protection at interface LCD with each device having its own 40 character custom label that location. for precise identification. TrueAlarm Addressable sensor operation IDNet+Addressable Channel Capacity The 4007ES provides an isolated output IDNet+signaling line circuit Addressable initiating device communications include operation of (SLC)that supports up to 250 addressable monitor and control points TrueAlarm smoke and temperature sensors.Smoke sensors transmit intermixed on the same pair of wires.(250 total requires two A007-9803 an output value based on their smoke chamber condition and the CPU IDNet+Loop Expansion Modules.) maintains a current value,peak value,and an average value for each sensor.Status is determined by comparing the current sensor value to Table 1:IDNet+SLC Wiring Specifications its average value.Tracking this average value as a continuously shifting Specification Rating ■ reference point filters out environmental factors that cause shifts in Maximum Distance 0 to 125 4000 ft(1219 m);50 ohms sensitivity. from Control Panel per 126 to 2500 ft(762 m);35 ohms Device Load 250 MIV Total Wire Length Allowed With Up to 12,500 ft(3.8 km);0.60 pF "T"Taps for Class B Wiring Maximum Capacitance 1 pF Figure 3: TrueAlarm Figure 4: TrueAlarm Photo/ Between IDNet+Channels Photo Sensor with Base Heat Sensor in CO Base Loading per device 0.8 mA supv.,1 mA alarm;2 mA per activated device LED Programmable sensitivity Shielded or unshielded,twisted or Wire Type and Connections untwisted wire* Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration(shown directly in lConnections (Terminal blocks for 18 to 12 AWG percent)or for specific heat detection levels.To evaluate whether the Compatibility includes:IDNet communicating devices and TrueAlarm sensitivity should be revised,the peak value is stored in memory and can sensors including QuickConnect and QuickConnect2 sensors be easily read(or downloaded as a report)and compared to the alarm Note:*Some applications may require shielded wiring.Review your threshold directly in percent. system with your local Autocall product supplier. Page 3 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification IDNAC SLC Control of TrueAlert and TrueAlert ES TrueAlert ES Appliance Self-Test Operation Addressable Notification On-Board Test Sensors Addressable notification appliance communications TrueAlert ES appliances are equipped with on-board sensors to detect Addressable notification appliance communications include operation of strobe and/or horn output allowing efficient and unobtrusive Self- TrueAlert and TrueAlert ES Visible only(V/O,strobe),Audible only(NO, Testing.When Automatic Self-Test is initiated from the control panel, horn),AudibleNisible(AN,horn/strobe),and strobes of SpeakerNisible each appliance within the selected VNAC group will briefly operate and (SN)notification appliances.(SN appliances require separate speaker then report its Self-Test status to the control panel,all within several wiring.)IDNAC SLC addressable communications allow each horn and seconds.Silent Self-Test can be selected to test only visible appliance if strobe to be individually controlled using a single two-wire circuit, desired.The control panel is in a trouble condition during testing and in confirms the wiring connections to the individual notification appliance's the event of an alarm,Self-Test is automatically terminated. electronic circuit,and confirms communications between each appliance Automatic Self-Test and the fire alarm control unit.Addressable communications increases supervision integrity versus conventional notification systems by Results are communicated to the control panel with a time and date providing supervision beyond the circuit wiring to each individual stamp and are stored in memory.Results are viewable at the front panel appliance and by constantly verifying the ability of each appliance to display and printed reports are available from the panel USB port. communicate with the control panel. Individual Self-Test Individual Appliance Status and Settings Self-Test is selected from the control panel when individual appliances The fire alarm control unit monitors and records each addressable need to be observed to operate.Each appliance in the selected VNAC notification appliance status,type of appliance,and its configured group will turn on its LED until individually activated by applying a appliance settings.A fault in any individual appliance automatically magnet.After performing the individual test,the appliance LED turns reports a trouble condition to the control panel. off to indicate completion.Results are recorded the same as during the automatic test. :I ;•'.I IDNAC SLC Hardware Reference FIttE FI'hE The 4007E5 provides a 3 A IDNAC SLC for control and power to TrueAlert NO °`" WO strobe ""°°`"'s"°°e ES and TrueAlert addressable notification appliances.The power supply incorporates an efficient switching design that provides a regulated Figure 5: TrueAlert ES Addressable Appliance Reference output of 29 VDC,even during battery operation.With 29 VDC minimum Virtual NACs Provide Control Convenience output at the panel,addressable notification SLCs can support wiring distances two to three times farther than available with conventional For control convenience,IDNAC notification appliances can be grouped into Virtual NAGS(VNACs)for group control. notification,or support more appliances per SLC,or work with smaller gauge wiring,or combinations of these benefits.The result is installation Panel Control Convenience and maintenance savings with high assurance that appliances that Applicable operation settings for each appliance can be programmed operate during normal system testing will operate during worst case without having to replace appliances or remove them from the wall or alarm conditions. ceiling.An appliance's VNAC notification zone can be easily changed through programming without having to add additional circuits,conduit, IDNAC SLC Appliance Wiring Reference and wiring.Audible and visible appliances for non-fire emergency IDNAC SLC Capacity communications notification can be programmed to operate separately on the same pair of wires as the fire alarm notification appliances.The Up to 127 addresses and up to 139 unit loads(appliances are typically result is lower installation,retrofit,and overall life cycle cost of ownership one unit load,devices such as Isolators may require more than one load, compared with traditional conventional notification systems. refer to individual device data sheet for specific information. Table 2:IDNAC SLC Appliance Wiring Reference Installation,Retrofit,and Life-Cycle Cost Benefits With each addressable appliance capable of being controlled separately Wiring Reference Description on the same two-wire IDNAC SLC,installation time and expense for Recommended Wire Type UTP,unshielded twisted pair both retrofit and new construction can be significantly reduced.When Maximum wire length allowed with 10,000 ft(3048 m) Class B wiring is used,wiring can be"T-tapped"allowing more savings "T-Taps"for Class B wiring,per SLC in distance,wire,conduit(size and utilization),and overall installation Maximum wire length per SLC to 4000 ft(1219 m) efficiency. any appliance Appliance Supervisory Current 1 unit load=0.8 mA per appliance Location Information,Diagnostics and Troubleshooting (Wiring Connections Terminals for 18 to 12 AWG Each addressable notification appliance has its own 40 character custom label to identify the location of the appliance and to aid in troubleshooting fault conditions.In conventional notification systems, conventional appliances are not capable of communicating with the control panel.Fault reporting on a conventional system is limited to the circuit wiring and the entire area(zone)covered by appliances on the notification appliance circuit(NAC)making it much more difficult and costly to locate and correct the source of a problem.Using the TrueAlert magnet test allows each appliance to individually identify its candela setting and address and to briefly operate if desired,and using the TrueAlert ES Appliance Self-Test feature provides detailed performance verification per appliance. Page 4 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification 4007ES Mounting and Module Location Reference 1 20-7/8"(530 mm) =I ; ) 1= 16"(406 mm) !1 i,Ll 1 r ! LLtliiil,lll!!,, • r o .. i t 4,4, t`iY€ '..F. Qom' + _ • rIi - .-0 r 1 WEI•4 1 1 i 01 F Ill i�£'i r_ lo � 7 .'`' ....A t -A,1 rs IMO s s ,Imo ' ..� rq--W %: s s s u ... I [ s Maw --. s - H 20-3/16,' ,EUE. (512 mm) I. a �1ti! , Fir..ip... �,, EE f(n^ y s wcE iA _ D s - - _ = yr ,, - ----_ ---—---- . 1 I II Side View Reference 1, Finished wall surface(including \�' semi-flush Trim Kit if used) Exposed box for semi-flush mounting 1-3/4"(44 mm)minimum_ 4-7/16"Deep(112 mm) I- `I Table 3:Module locations Key Description I A CPU and User Interface assembly. B (Location for optional A007-9805 LED Module. C Power supply Assembly. D A007-9806 SDACT location. Note:The SDACT includes a 650-1838 flat mounting bracket(available separately).Some pre-existing systems with an angled SDACT bracket will need to be replaced with the flat mounting bracket when a Network Interface Card is installed. E Location for A007-9801 Zone/Relay Module,A007-9812 Dual RS-232 Interface,or(as shown)A007-9802 25 V Regulator Module F Primary location for A007-9801 Zone/Relay Module G Location for additional A007-9801 Zone/Relay Module. H Identical to Block G above. • I A007-9807 or A007-9808 City Circuit Module,or A007-9809 Relay Module. J A007-9803 IDNet+Loop Expansion Modules,maximum of two(two are shown). K Identical to block)above. L Block L is an additional block that sits on spacers above Block G and H.You can mount the A007-9817 NIC in block L with or without modules mounted below it in blocks G and H.When you use fiber media cards and an SDACT is present,the SDACT requires a 650-1838 flat mounting bracket,ordered separately. M Battery location for up to 18 Ah batteries. Note:No conduit entry or wiring in this area,14 7/8 in.(378 mm)wide. Note: A system ground must be provided for Earth Detection and transient protection devices.This connection shall be made to an approved, dedicated Earth connection per NFPA 70,Article 250,and NFPA 780. Page 5 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Power Supply Output and Zone/Relay Module Details Power Supply Output Details: • 2 A Auxiliary Output(AUX/SNAC)can be selected either as resettable auxiliary power of 2 A @ 24 VDC,or selected to be a simple NAC(SNAC)for sounder base power,four-wire detector power,or door holder power • 4 A Output Rating.This includes current for:IDNAC controlled notification appliances;IDNet devices;module currents;and auxiliary output current (battery charging,CPU,and power supply current are not subtracted from the 4 A) • Low Battery Voltage Cutout is selectable when required(required for ULC listing applications) • Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions;status information provided to the master controller includes analog values for:battery voltage,charger voltage and current,actual system voltage and current,and IDNAC SLC current • Battery Charger is dual rate,temperature compensated,and charges up to 18 Ah sealed lead-acid batteries in the battery compartment,and charges up to 33 Ah batteries in an external cabinet • IDNet+SLC Output provides electrically isolated Class B or Class A communication;standard capacity is up to 100 addressable points with expansion for up to 250 points using up to two A007-9803 IDNet+Loop Expansion Modules(see) • Compatible RUI remote equipment includes:A4606-9202 and A4606-9205 Color Touchscreen Annunciators(up to 6 total),4100 Series 24 I/O and LED/Switch modules,A602 Series LED/Switch and I/O Annunciator modules,including A602-9101 Status Command Units(SCU),and A602-9102 Remote Command Units(RCU) • RUI Communications controls up to 10 remote devices at up to 2500 ft(762 m)for single run,or 10,000 ft(3048 m)total if wiring is Class B and T- tapped;output is selectable as Class B or Class A Product Selection Table 4:Product Selection Model Color Description Supv. lAlarrn A007-9201 Red 4007ES with a 3 A,Class B,IDNAC SLC for up to 127 addressable notification 180 mA 185 mA A007-9202 Platinum appliances,and 4 A output power supply/battery charger;includes IDNet+ communications for 100 addressable points Note:Add optional module and other currents separately for battery calculations; base panel current does not subtract from the 4 A power available for optional modules and external loads Module and Accessories Selection Information Table 5:Factory Programming Options Mode Description . IA007-8810 1Factory Programming(select) Table 6:Field Installed Optional Modules SKU (Description Supv. (Alarm Eight Point Zone/Relay Module;each point is selectable as an IDC input or Relay output,Class A IDCs require two points(one out and one return);select up to four maximum.Alarm current shown is for eight Class B IDCs using 3.3K end-of-line- A007-9801 resistors with four IDCs in alarm and four IDCs in standby.Supervisory current shown 83 mA max 295 mA max is for all eight IDCs in standby.Detector current is added separately.Refer to 4007ES Hybrid data sheet AC4007-0001 and 579-1103AC Zone/Relay Module Installation Instructions for additional information. 25 VDC Regulator Module;2 A maximum output; with 1 module 190 mA 445 mA use to power Zone/Relay modules connected to with 2 modules 290 mA 801 mA A007-9802 initiating devices requiring nominal 25 VDC voltage; refer to technical publication 579-832AC 2-Wire with 3 modules 390 mA 1156 mA Detector Compatibility Chart for application details IDNet+Loop Expansion Module;provides an additional isolated loop with short circuit A007-9803 isolation to the existing IDNet+channel,also provides an additional 75 addressable NA NA points to the IDNet+channel capacity,maximum of two Dual Class A IDNAC Isolator(DCAI);converts a single Class B IDNAC SLC input to two Class A or two Class B SLC outputs;provides short circuit isolation between each Class A or B output circuit;requires one IDNAC address;the total current remains controlled by the Class B input source SLC at 3 A maximum;maximum 30 appliances per isolated A007-9804 loop 12.7 mA 25 mA Note:Up to 30 additional device addresses may be installed between each A4905-9929 TrueAlert Addressable Isolator+Module,not to exceed the maximum address and unit loading specifications for the IDNAC channel. Page 6 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Table 6:Field Installed Optional Modules SKU Description Supv. Alarm Panel Mounted 48 LED Status Annunciator Module;provides no LEDs on 10 mA 10 mA A007-9805 24 Yellow LEDs,20 Red LEDs,and four Red/Green LEDs that are programmable for up to 24 IDC zones of alarm and trouble with LEDs on 1.75 mA per LED,105 mA max annunciation,or as required for custom annunciation requirements A007-9806 SDACT Module for Point or Event Reporting;order connection cables as required(see 30 mA 40 mA cable details under accessories). A007-9807 (City Circuit Module with Disconnect Switch 20 mA 36 mA A007-9808 (City Circuit Module without Disconnect Switch 20 mA 36 mA A007-9809 1Relay Module;relays for Alarm,Supervisory,and Trouble;rated 2 A resistive @ 32 VDC 15 mA 37 mA A007 9812 Dual RS-232 Interface Module,compatible with Autocall remote printer,PC 60 mA 60 mA annunciator or third party interface(two ports/connections maximum). Table 7:Field Installed Optional Network Modules SKU Card type Description Size Alarm/Supv. A007-9817 Flat Connects a 4007ES FACU to an ES network.Supports Class B or Class 2 vertical 120 mA X operation.Includes four built in Ethernet ports,supports up to two blocks additional media cards.Ports A and C can be configured for earth fault (only in detection. Block L) A007-6308 ES Net NIC Dual Channel Select per network connection requirements;mounts on the supplied ES N/A 135 mA Single-mode Fiber Media Net NICs;two media cards per slot type and flat type NIC. Card Dual Channel Media Cards provide two ports for input and output A007-6309 ES Net NIC Dual Channel connections. N/A 135 mA Multi-mode Fiber Media 'Field connections require proper port pairing,refer to 579-1258AC ES Net Card Dual Channel Fiber,Ethernet,and DSL Media Card Installation Instructions A007-6307 ES Net NIC Dual Channel for additional information. N/A 155 mA DSL Media Card Network Interface and Network Media Card Product Selection 4007ES fire alarm control units are compatible with Autocall ES Net network. • Refer to datasheet AC4100-0076 for additional information on compatible ES Net fire alarm products. • Refer to datasheet AC4100-0061 for additional information on the Building Network Interface Card. Table 8:Batteries Model Capacity Battery Mounting Details 2081-9272 6.2 Ah 12 V Batteries for cabinet mounting;select one battery model per system 2081-9274 110 Ah (standby requirements;order quantity of two;to be wired in series for 24 I2081-9275 118 Ah IN/DC 2081-9271 33 Ah For remote mount in Battery Box Batteries for remote mounting;see 4009-9802 battery cabinet details below Table 9:Battery Accessories SKU Color Capacity Dimensions Description A009-9801 Beige For up to 25 Ah batteries 16 1/4 in.W x 13 1/2 in.H x 5 3/4 in. External battery cabinet without charger,with D(413 mm x 343 mm x 146 mm) locking solid door and battery harness;for close- 4009 9802 Beige For up to 33 Ah batteries 25 3/4 in.W x 20 3/4 in.H x 4 1/8 in. nippled mounting to fire alarm control unit D(654 mm x 527 mm x 105 mm) cabinet Table 10:Accessories SKU Description 2080-9047 DACT cable,14 ft(4.3 m)long,RJ45 plug one end,spade lugs on the other;order one per phone line connection required A2975-9812 (Red semi-flush box trim;1 7/16 in.(37 mm)wide,four corners and trim pieces for top,bottom,and sides A2975-9813 (Platinum semi-flush box trim;1 7/16 in.(37 mm)wide,four corners and trim pieces for top,bottom,and sides A4081-9018 10 ko,1 W end-of-line resistor harness for non-addressable NACs(if A007-9801 is used) General Specifications Table 11:General Specifications Specification Rating 1120 VAC Input 2 A maximum @ 102 to 132 VAC,50/60 Hz Input Power 240 VAC Input 11 A maximum @ 204 to 264 VAC,50/60 Hz Battery 16 A maximum @ 24 VDC(during battery operation) Page 7 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification Table 11:General Specifications Specification Rating 4 A output for"Special Application"appliances Power Supply Note:The 4 A output rating was determined such that optional module currents, Output Rating and external device and appliance currents can be directly added together,not to Output switches exceed 4 A total. to battery 4007ES Power Supply IDNAC SLC Ratings 3 A,regulated 29 VDC during Alarm,127 addresses,139 unit loads;DC-DC converter backup during Output Ratings circuit is>92%efficient over operating range mains AC failure Output terminals are rated for 18 to 12 AWG with duplicate output terminals rated or brownout IDNAC SLC Wiring for two wires each,allowing up to four(4)Class B branch circuit T-taps to be made conditions in the cabinet;additional T-taps may be made in external wiring junction cabinets or boxes Auxiliary Power Tap 2 A maximum,24 VDC nominal(19.5 to 31.1 VDC) Compatible Special Application Autocall TrueAlert ES and TrueAlert addressable notification appliances;contact your Autocall product Appliances representative for compatible appliances Battery Charger Battery capacity range UL and ULC listed for battery charging of 6.2 Ah up to 33 Ah(batteries larger than 18 Ah require a Ratings(sealed remote battery cabinet) lead-acid batteries) Charger characteristics Temperature compensated,dual rate,recharges depleted batteries within 48 hours per UL Standard and performance 864;to 70%capacity in 12 hours per ULC Standard S527 Supported file types:JPG,BMP,GIF,and PNG Custom Background Display Details Recommended image type is jPG,recommended image size is 480 x 240,and the file size limit is 100kb Environmental Operating Temperature I32°F to 120°F(0°C to 49°C) Operating Humidity IUp to 93%RH,non-condensing @ 90°F(32°C)maximum 4007ES and Network Product Reference Table 12:Additional 4007ES and network product reference (Subject 1Datasheet Serial DACT(SDACT)for 4100ES,4010ES,4007ES AC208o-00080-0009 Seismic Battery Brackets Reference AC2081-0019 4007ES Panels with Conventional Notification AC4007-0001 4007ES Extinguishing Release Applications AC4007-0003 4009 IDNet NAC Extender AC4009-0002 4009 IDNAC Repeater IAC4009-0004 External 110 Ah Battery Charger for 4100ES,4010ES IAC4081-0002 Graphic I/O Modules for 4100ES,4010ES,4007ES AC4100-0005 Interface to VESDA Air Aspiration Detection Systems AC4100-0026 'InfoAlarm Command Center with SPS Power Supplies AC4100-0045 BACpac Ethernet Module AC4100-0051 Building Network Interface Card(BNIC) IAC4100-0061 ES Net Network Products and Specifications IAC4100-0076 NDU with SPS Power Supplies for ES Net AC4100-0077 InfoAlarm Command Center with EPS Power Supplies AC4100-0101 .NDU with EPS Power Supplies for ES Net AC4100-0104 PC Annunciator AC4190-0013 TrueSite Workstation IAC4190-0016 TrueSite Incident Commander IAC4190-0020 SCU/RCU Annunciators AC4602-0001 A4606 Series ColorTouchscreen LCD Annunciators AC4606-0003 Page 8 AC4007-0002 Rev. 17 06/2020 I.NAUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification 4007ES Additional Reference rIIIIIIIIIIIIIIIIIIIIIIIiiiiiiiiiIIIIIII111llliiiiii lllllllllll _____ pcc [[ 77 0 • r r--1 Figure 7: A4606-9205(Platinum)Color �;;` LCD Touchscreen Remote Annunciator 0o0 -a=— I o� 111111111111111111111111111111111111111111111111111111111111111Illllll O 41 Figure 6: 4007ES with IDNAC Notification and Figure 8: A4606-9202(Red)Color LCD optional 48 LED Annunciator Module(A007-9805) Touchscreen Remote Annunciator TrueAlert ES appliance self-test last test results report example Service Port Page 1 REPORT 10 TrueAlertES Self-Test Report 12:34:56pm MON 01-JUN-15 Point ID Custom Label Date Visual Audible T1-1-1 VO FIRST FLOOR (up to 40 characters) 01-JUN-15 NO OUT N/A T1-2-5 AV FIRST FLOOR EAST WING 01-JUN-15 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 01-JUN-15 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 01-JUN-15 NOT TST N/A T8-2-60 AV SECOND FLOOR ROOM 22 01-JUN-15 NORMAL NORMAL T1-2-4 AO FIRST FLOOR ROOM 17 01-JUN-15 N/A UNSUPP TRUEALERT_ES SELF-TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort Figure 9: Reports example Results Description: NORMAL=works correctly NO OUT=No Output,no light or sound was detected NOT TST=no result;either the appliance did not return a result before the test ended or the test was conducted as silent(strobes only)and audible appliance was not activated N/A=not applicable(no strobe on audible only,etc.) UNSUPP=appliance not compatible with Self-Test(TrueAlert addressable appliance not TrueAlert ES addressable appliance) Note:Additional TrueAlert ES Self-Test information is detailed in Operating Instructions 579-1165AC shipped with the panel. Page 9 AC4007-0002 Rev. 17 06/2020 (' AUTOCALL 4007ES Fire Detection and Control with Addressable Initiation and Addressa le Notification TrueAlert ES Appliance Self-Test All Test Results Report Example Service Port Page 1 REPORT 10 TrueAlertES Self—Test Report 12:34:56pm MON 01—JUN-15 Point ID Custom Label Date Visual Audible T1-1-1 VO FIRST FLOOR 01—JUN-15 NO OUT N/A T1-2-5 AV FIRST FLOOR EAST WING 01—JUN-15 NO OUT NORMAL T1-2-6 AV FIRST FLOOR NORTH ENTRANCE 12—MAY-15 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 01—JUN-15 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 01—JUN-15 NOT TST N/A T1-1-11 AV FIRST FLOOR SOUTH ENTRANCE 12—MAY-15 NORMAL NORMAL T8-2-60 AV SECOND FLOOR ROOM 22 01—JUN-15 NORMAL NORMAL T1-2-4 AO FIRST FLOOR ROOM 17 01—JUN-15 N/A UNSUPP T1-2-7 AO FIRST FLOOR ROOM 12 12—MAY-15 N/A UNSUPP T8-3-43 AV SECOND FLOOR ROOM 25 12—MAY-15 UNSUPP UNSUPP TRUEALERT_ES SELF—TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL—X to abort Figure 10: Report example TrueAlert ES Appliance Self-Test Individual Appliance Report Example CUSTOM LABEL 4-1-2 AV POINT ADDRESS: 4-1-2 Type AV CAR D: 4 CHANNEL: 1 DEVICE: 2 EXTENDED POWER SUPPLY UNIT NUMBER: 2 RUI NUMBER: LOCAL PRIMARY STATUS NORMAL AUDIBLE GROUP CONFIG: 0 0 0 VISUAL GROUP CONFIG: 0 0 0 STYLE: INDOOR OPERATION: GENERAL EVAC CANDELA RATING 15 CD COLOR LENS YES TONE TYPE BROADBAND CODING TYPE TEMPORAL VOLUME HIGH LAST TEST TIME: MON 01-JUN-15 01 :00 AM LAST VISUAL TEST: NORMAL LAST AUDIBLE TEST: NORMAL LAST TEST VOLUME: NORMAL DEVICE TEST TROUBLE: NORMAL Figure 11: Report example ©2020 johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC4007-0002 Rev.17 06/2020