HomeMy WebLinkAbout4098-9714 DATASHEET ( AUTOCALL TrueAlarm Analog Sensing UL, ULC,CSFM Listed* TrueAlarm Analog Sensors— Photoelectric and Heat; Standard Bases and Accessories Features environmental factors(dust,dirt,etc.)and component aging,providing an accurate reference for evaluating new activity.With this filtering,there TrueAlarm analog sensing provides: is a significant reduction in the probability of false or nuisance alarms • Digital transmission of analog sensor values via IDNet two-wire caused by shifts in sensitivity,either up or down. communications Control Panel Selection. For use with the following Autocall products: Peak activity per sensor is stored to assist in evaluating specific locations. • 4007ES,4010ES,4100ES,and 4100U Series control panels The alarm set point for each TrueAlarm sensor is determined at the host control panel,selectable as more or less sensitive as the individual Fire alarm control panel provides: application requires. • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72 sensitivity testing ‘111.. requirements;automatic individual sensor calibration check verifies sensor integrity •Automatic environmental compensation,multi-stage alarm operation, I 111 III` I I I= II I and display of sensitivity directly in percent per foot •Ability to display and print detailed sensor information in plain English language Figure 1: A4098-9714 TrueAlarm Photoelectric smoke sensors provide: Photoelectric Sensor Mounted in Base • Seven levels of sensitivity from 0.2%to 3.7% Timed/Multi-Stage Selection. Heat sensors provide: Sensor alarm set points can be programmed for timed automatic •Three fixed temperature sensing thresholds: 135°F,155°F and 190°F sensitivity selection(such as more sensitive at night,less sensitive during • Rate-of-rise temperature sensing day).Control panel programming can also provide multi-stage operation • Utility temperature sensing per sensor.For example,a 0.2%level may cause a warning to prompt • Listed to UL 521 and ULC 5530 investigation while a 2.5%level may initiate an alarm. General features: Sensor Alarm and Trouble LED Indication. Operation is for ceiling or wall mounting Each sensor base's LED pulses to indicate communications with the • panel.If the control panel determines a sensor is in alarm,or is dirty • Listed to UL 268 and ULC-5529 or has some other type of trouble,the details are annunciated at the • NEMA 1 rated.See TrueAlarm Analog Sensing Product Selection Chart control panel and that sensor base's LED will be turned on steadily. for more information. During a system alarm,the control panel will control the LEDs such that • Louvered smoke sensor design enhances smoke capture by directing an LED indicating a trouble will return to pulsing to help identify the flow to chamber;entrance areas are minimally visible when ceiling alarmed sensors. mounted • Designed for EMI compatibility Sensor Base Features • Magnetic test feature is provided Base mounted address selection: • Different bases are available to support a supervised or unsupervised • Address remains with its programmed location output relay,and/or a remote LED alarm indicator • Accessible from front(DIP switch under sensor) Additional base reference: General features: • For isolator bases,refer to data sheet AC4098-0025 For sounder bases,refer to data sheet AC4098 0028 • Automatic identification provides default sensitivity when substituting • sensor types • For photo/heat sensors,refer to data sheet AC4098 0024(single • Integral red LED for power-on(pulsing),or alarm or trouble(steady on) address)and AC4098-0033(dual address) • Locking anti-tamper design mounts on standard outlet box Description • Magnetically operated functional test Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Autocall addressable communications.At the control panel,the data is analyzed and an average value is determined and stored.An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point.This software filtering process compensates for *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listings 7300-2269 0550, 7300-2269:0551,7300 7300-2269:0531,7300-2269:0538,7270-2269:0512 and 7272-2269:0537 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable;contact your local product supplier for the latest status. AC4098-0019 Rev. 26 1/2020 •AUTOCALL TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories Sensor Bases A4098-9792,Standard Sensor Base A4098-9789,Sensor Base with wired connections for: •A2098-9808 Remote LED alarm indicator or A4098-9822 relay(relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases: •A4098-9791,4-Wire Sensor Base,use with remote or locally mounted A2098-9737 relay,requires separate 24 VDC •A4098-9780,2-Wire Sensor Base,use with remote or locally mounted A4098-9860 relay,no separate power required • Supervised relay operation is programmable and can be manually operated from control panel • Includes wired connections for remote LED alarm indicator or A4098-9822 relay(relay is unsupervised and requires separate 24 VDC) Sensor Base Options A2098-9737,Remote or local mount supervised relay: • DPDT contacts for resistive/suppressed loads,power limited rating of 3 A @ 28 VDC;non-power limited rating of 3 A @ 120 VAC(requires external 24 VDC coil power) A4098-9860,Remote or local mount supervised relay: • SPDT dry contacts,power limited rating of 2 A @ 30 VDC,resistive;non-power limited rating of 0.5 A @ 125 VAC,resistive ALARM A4098-9822,LED Annunciation Relay: •Activates when base LED is on steady,indicating local alarm or trouble • DPDT contacts for resistive/suppressed loads,power limited rating of 2 A @ 28 VDC;non-power limited rating of 1/2 A @ 120 VAC,(requires external 24 VDC coil power) 4098-9832,Adapter plate: • Required for surface or semi-flush mounting to 4"square electrical box and for surface mounting to 4"octagonal box • Can be used for cosmetic retrofitting to existing 6-3/8"diameter base product Figure 2: Remote A2098-9808,Remote red led Alarm Indicator: red LED Alarm Indicator • Mounts on single gang box(shown in illustration) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base,different sensor types can be easily interchanged to meet specific location requirements.This feature also allows intentional sensor substitution during building construction.When conditions are temporarily dusty,instead of covering the smoke sensors (causing them to be disabled),heat sensors may be installed without reprogramming the control panel.Although the control panel will indicate an incorrect sensor type,the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: • Selectable rate compensated,fixed temperature sensing with or without rate-of-rise operation • Rated spacing distance between sensors: Fixed Temp.Setting UL&ULC Spacing IFM Spacing,Either Fixed Temperature Setting 135°F(57.2°C) 60 ft x 60 ft(18.3 m) 120 ft x 20 ft(6.1 m)for fixed temperature only;RTI=Quick 155°F(68°C) 40 ft x 40 ft(12.2 m) 50 ft x 50 ft(15.2 m)for fixed temperature with either rate-of-rise selection;RTI= Ultra Fast Note:*190°F(88°C)ratings apply only to the A4098-9734 sensor. Smoke Sensors: • Photoelectric technology sensing • 360°smoke entry for optimum response • Built-in insect screens Page 2 AC4098-0019 Rev.26 1/2020 V AUTOCALL TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories Mounting Reference Electrical Box Requirements:(boxes are by others) Without relay in the box:4"octagonal or 4"square, 1-1/2"deep; single gang,2"deep With relay in the box:4"octagonal or 4"square, 1-1/2"deep, with 1-1/2"extension ring 4"(102 mm)Square Box 4"(102 mm)Octagonal Box Surface mount reference C, C C C 1-1/2"(38 mm) minimum box depth Flush mount reference,mount even with final surface,or with up to 1/4"(6.4 mm)maximum recess Supervised Relay1 Relay(mounts (mounts in base electrical box or in base electrical box) remotely) III I- I Relay Size: 2-1/2"X 1-1/2"X 1" (3.75 in3)(64 mm X 38 mm X 25.4 mm) Supervised Relay2(mounts in base electrical box or remotely;2-3/8"X 1-1/4"X 11/32" (1 in3)(60.4 mm X 31.8 mm X 8.6 mm) NOTE:Review total wire count,wire size,and accessories being wired to determine required box volume. k 6-3/8"(162 mm) Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4"square flush box - 4-7/8"(124 mm) 15/16" (24 mm) TrueAlarm Bases Figure 3: Mounting Reference Table 1:Product mounting-SKU reference Product SKU Relay A4098-9822 Supervised Relay 1. A2098-9739 2. A4098-9860 Adapter plate I4098-9832 TrueAlarm Bases IA4098-9780,A4098-9789,A4098-9791,A4098-9792 Page 3 AC4098-0019 Rev.26 1/2020 COAUTOCALL TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories A4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing.Seven levels of sensitivity are available for each individual sensor,ranging from 0.2%to 3.7%per foot of smoke obscuration. Sensitivities of 0.2%,0.5%,and 1%are for special applications in clean areas.Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and 3.7%.Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360°smoke entry for optimum response to smoke from any direction.Due to its photoelectric operation,air velocity is not normally a factor,except for impact on area smoke flow. 4-7/8"(124 mm) ► li*—LED status indicator / 2-1/8" (54 mm) 1 III Figure 4: A4098-9714 Photoelectric Sensor with Base A4098-9733 and A4098-9734 Heat Sensors TrueAlarm heat sensors are self-restoring and provide rate compensated,fixed temperature sensing,selectable with or without rate-of-rise temperature sensing.Due to its small thermal mass,the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15°F(8.3°C)or 20°F(11.1°C)per minute.Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135°F(57.2°C)or 155°F(68°C).In a slow developing fire,the temperature may not increase rapidly enough to operate the rate-of-rise feature.However,an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32°F to 155°F(0°C to 68°C). This feature can provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availability. 4 7/8"(124 mm) . 1Z. 7/8"(124 mm) :/ LED status indicator / \ t-l•---LED status indicator( 2-3/8" \ / 2-3/8" (60 mm) \ / (60 mm) Figure 5: A4098-9733 Heat Sensor with Base Figure 6: A4098-9734 High Temperature Heat Sensor with Base WARNING:In most fires,hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm.In cases where Life Safety is a factor,the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected.Refer to NFPA 72,the National Fire Alarm and Signaling Code.On smooth ceilings,smoke sensor spacing of 30 ft(9.1 m)may be used as a guide.* *For detailed application information including sensitivity selection,refer to Installation Instructions 574-709AC. TrueAlarm Analog Sensing Product Selection Chart Table 2:TrueAlarm Sensor Bases(for use with Sensors A4098-9714 and A4098-9733) SKU lolor Description Compatibility Mounting Requirements A4098-9792 White 4"octagonal or 4"square box, A4098 9776 Black Standard Sensor Base No options 1-1/2"min.depth;or single gang box,2"min.depth Page 4 AC4098-0019 Rev.26 1/2020 •AUTOCALL TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories Table 2:TrueAlarm Sensor Bases(for use with Sensors A4098-9714 and A4098-9733) SK Color Description Compatibility Mounting Requirements A4098-9789 White Sensor Base with connections 4"octagonal or 4"square box A4098-9789 White for Remote LED Alarm Indicator A2098 9808 Remote Alarm Indicator or A4098-9775 Black or Unsupervised Relay A4098-9822 Unsupervised Relay Note: 4-Wire Sensor Supervised Relay IA2098-9737 Supervised Remote Relay Box depth requirements depend A4098-9791 ** White Base with connections for LED A2098-9808 Remote Alarm Indicator or on total wire count and wire size, Indicator or Unsupervised Relay A4098-9822 Unsupervised Relay refer to accessories list below for A4098-9860 Supervised Remote Relay efei ei ire. 2-Wire Sensor Supervised Relay **A4098-9791 and A4098-9780 A4098-9780** White Base with connections for LED A2098-9808 Remote Alarm Indicator or are NOT compatible with the 2120 Indicator or Unsupervised Relay A4098-9822 Unsupervised Relay CDT Refer to Application Manual 574-709AC and Installation Instructions 574-707AC for additional information. Table 3:TrueAlarm Sensors SKU Color Description 1Compatibility Mounting Requirements A4098-9714 1 White A4098-9714 IND 1 Photoelectric Smoke Sensor A4098-97741 Black Bases A4098-9775,A4098-9776, ^A098-9792,A4098-9789,A4098-9791, Refer to base requirements A4098-9733 1 White and A4098-9780 Heat Sensor A4098-9778 1 Black A4098-9734 1 White High Temperature Heat Sensor 1NEMA 1 rated. Table 4:TrueAlarm Sensor/Base Accessories SKU Description (Compatibility Mounting Requirements A2098-9737 Supervised Relay,mounts remote or in base For use with A4098-9791 base Remote Mounting requires 4"octagonal electrical box or 4"square box,1-1/2"minimum depth A4098-9860 Supervised Relay,mounts remote or in base For use with A4098-9780 base Base Mounting requires 4"octagonal electrical box box,2-1/8"deep with 1-1/2"extension ring A2098 98081 Remote Red LED Alarm Indicator on single Bases A4098-9789,A4098-9791,and Single gang box,1-1/2"minimum depth gang stainless steel plate A4098-9780 A4098-9822 Unsupervised Relay,tracks base led status; Bases A4098-9789,A4098-9791,and 4"octagonal box,2-1/8"deep with 1-1/2" Note:Mounts only in base electrical box A4098-9780 extension ring Bases A4098-9792,A4098-9789, Required for surface or semi flush 4098-9832 Adapter Plate A4098 9791,and A4098-9780 mounted 4"square box and for surface mounted 4"octagonal box NEMA 1 rated. Specifications Table 5:General Operating Specifications Specification Rating Communications and Sensor Supervisory Power IIDNet communications,auto-selected,1 address per base Communications Connections Screw terminals for in/out wiring,18 to 14 AWG(0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads,18 AWG(0.82 mm2) UL Listed Operating Temperature Range 32°to 100°F(0°to 38°C) with A4098-9733 Heat 32°to 122°F(0°to 50°C) Sensor Operating Temperature with A4098-9714 Smoke 15°to 122°F(-9°to 50°C) Range Sensor with A4098-9734 Heat 32°to 150°F(0°to 66°C) Sensor Storage Temperature Range 0°F to 140°F(-18°C to 60°C) Humidity Range 10 to 95%RH A4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min(0-1220 m/min) Housing Color 1Frost White or Black Page 5 AC4098-0019 Rev.26 1/2020 •AUTOCALL TrueAlarm Analog Sensors- Photoelectric and Heat; Standard Bases and Accessories Table 6:A4098-9791 Base With Supervised Remote Relay A2098-9737 Specification Rating Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current 270 NA,from 24 VDC supply Alarm Current with A2098-9737 Relay 28 mA,from 24 VDC supply Table 7:A4098-9780 Base With Supervised Remote Relay A4098-9860 Specification (Rating Power Supplied from communications Table 8:A4098-9822 Unsupervised Relay,Requirements for Bases A4098-9789,A4098-9791,and A4098-9780 Specification Rating Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current 1Supplied from communications Alarm Current 113 mA from separate 24 VDC supply ©2020johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Autocall product supplier for the latest status.Listings and approvals under Tyco Fire&Security GmbH,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). AC4098-0019 Rev.26 1/2020