HomeMy WebLinkAboutB19-2346 CF PC C; Butte County Fire Department FIRE 116 Cay Fire Prevention Bureau AJ` et, 176 Nelson Avenue Oroville, CA 95965Utte County RESCUE Office (530)538-7888 C • www.buttecounty.net/fire ""F°R",A NON RESIDENTIAL PLAN REVIEW LETTER August 20,2019 MARK SORENSEN PO BOX 307 BIGGS, CA 95917 APN: 001-062-007 Building Permit Number: B19-2346 Plan Check#1 Description: REMOVE INTERIOR WALL/ADD A WALL Occupancy Classification: /U Fire Sprinklers: No Building Total Area: @ 0 sf/U @ 0 sf Dear Applicant, The plans you recently submitted have been reviewed by the Fire Department referencing the 2016 edition of the California Fire Code (CFC). The numbered comments listed below in the body of this letter must be addressed prior to Fire Department Inspection of your project. 1. Extinguishers: Extinguishers shall be 2A:10BC. One extinguisher is required for every 3000 square feet and must be within 75' from any point. Extinguishers shall be mounted in a conspicuous place, easily accessible and readily available, and shall be along normal paths of travel. Extinguishers shall be mounted so that the top of the extinguisher is no higher than 5' above finished floor. Where extinguishers may be subject to physical damage they shall be adequately protected. 2. Exit signs shall be illuminated at all times and shall be provided with backup power source that will allow the continuation of the illumination for 90 minutes in case of power failure. 3. Ensure building and suites have appropriate building identification. Identification shall be placed in a position that is plainly visible from the street or road fronting property. Minimum 4" high and 0.5" stroke. Post address at the street main entrance and on the main or first building encountered. Ensure that other buildings on site are identified with same standard as address. Buildings can be numbered, lettered or named,but must be same label as staff on site uses. 4. Post a sign with the occupant load of the room or space in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. 5. Building will be subject to Fire Department Annual Inspection. The Fire Prevention Bureau is currently open to the public from 8:00 am to 5:00 pm. If you wish to discuss these plan check comments,please call during our business hours or contact us by e- mail at the address below. Permit status can be tracked by logging on to http://www.buttecounty.net/dds and clicking Building Permits Status. Chris Boyd John Gaddie Deputy Fire Marshal Fire Protection Planning 530.538.6320 530.538.6320 Chris.boyd@fire.ca.gov john.gaddie@fire.ca.gov