Loading...
HomeMy WebLinkAboutB19-1768 CF PC C; Butte County Fire Department FIRE 116 Cay Fire Prevention Bureau 176 Nelson Avenue Oroville, CA 95965Utte County RESCUE Office (530)538-7888 C • www.buttecounty.net/fire ""F°R",A NON RESIDENTIAL PLAN REVIEW LETTER July 5,2019 ECC CONSTRUCTORS LLC 1240 BAYSHORE HIGHWAY STE 301 BURLINGAME, CA 94010 APN: 040-520-100 Building Permit Number: B19-1768 Plan Check#1 Description: WAREHOUSE(5000)W/ELEC FOR BASECAMP Occupancy Classification: S-2/U Fire Sprinklers: No Building Total Area: S-2 @ 5000 sf/U @ 0 sf Dear Applicant, The plans you recently submitted have been reviewed by the Fire Department referencing the 2016 edition of the California Fire Code (CFC). The numbered comments listed below in the body of this letter must be addressed prior to Fire Department Final Inspection of your project. 1. Complete and return the attached Statement of Intended Use. 2. Access: An approved fire apparatus access road not less than 20 feet wide shall be provided for access within 150 feet of all portions of the building. 3. Address and Building Identification: Ensure building and suites have appropriate building identification. Identification shall be placed in a position that is plainly visible from the street or road fronting property. Minimum 4" high and 0.5" stroke. Post address at the street main entrance and on the main or first building encountered. Ensure that other buildings on site are identified with same standard as address. Buildings can be numbered, lettered or named,but must be same label as staff on site uses. 4. Extinguishers: Extinguishers shall be 2A1OBC. One extinguisher is required for every 3000 square feet and must be within 75' from any point. Extinguishers shall be mounted in a conspicuous place, easily accessible and readily available, and shall be along normal paths of travel. Extinguishers shall be mounted so that the top of the extinguisher is no higher than 5' above finished floor. Where extinguishers may be subject to physical damage they shall be adequately protected. The Fire Prevention Bureau is currently open to the public from 8:00 am to 5:00 pm. If you wish to discuss these plan check comments, please call during our business hours or contact us by e- mail at the address below. Permit status can be tracked by logging on to http://www.buttecounty.net/dds and clicking Building Permits Status. Chris Boyd John Gaddie Deputy Fire Marshal Fire Protection Planning 530.538.6320 530.538.6320 Chris.boyd@fire.ca.gov john.gaddie@fire.ca.gov