HomeMy WebLinkAboutB19-1647 CF PC Pavia Hulling C; Butte County Fire Department FIRE 116 Cay Fire Prevention Bureau AJ` et, 176 Nelson Avenue Oroville, CA 95965Utte County RESCUE Office (530)538-7888 C • www.buttecounty.net/fire ""F°R",A NON RESIDENTIAL PLAN REVIEW LETTER June 17,2019 NORTH VALLEY BUILDING SYSTEMS INC 30 SEVILLE COURT CHICO, CA 95928 APN: 047-150-070 Building Permit Number: B19-1647 Plan Check#1 Description: EQUIPMENT REPAIR SHOP(6000)LOFT(165) Occupancy Classification: S-1/U Fire Sprinklers: No Building Total Area: @ 0 sf/U @ 0 sf Dear Applicant, The plans you recently submitted have been reviewed by the Fire Department referencing the 2016 edition of the California Fire Code (CFC). The numbered comments listed below in the body of this letter must be addressed prior to Fire Department Approval of your project. 1. Please complete and return the attached Statement of Intended Use. Include type and amount of any combustible, flammable or hazardous materials. 2. Provide submittals for overhead fire door. 3. Openings in the three hour fire wall are limited to 156 square feet maximum per CBC Section 706.8. The proposed roll up door exceeds this. If you require a door larger than 156 square feet, change the fire wall to a fire barrier. 4. Provide a minimum of(3) 4A8OBC rated fire extinguisher mounted in an accessible conspicuous area. Travel distance to a fire extinguisher shall not exceed 50 feet from any point. 5. Address and Building Identification: Ensure building and suites have appropriate building identification. Identification shall be placed in a position that is plainly visible from the street or road fronting property. Minimum 4" high and 0.5" stroke. Post address at the street main entrance and on the main or first building encountered. Ensure that other buildings on site are identified with same standard as address. Buildings can be numbered, lettered or named,but must be same label as staff on site uses. 6. Notify Butte County Fire Department(530) 538-6320 if any hazardous operations,processes or storage will be conducted in any unit. A special permit from the Fire Department may be required. The Fire Prevention Bureau is currently open to the public from 8:00 am to 5:00 pm. If you wish to discuss these plan check comments,please call during our business hours or contact us by e- mail at the address below. Permit status can be tracked by logging on to http://www.buttecounty.net/dds and clicking Building Permits Status. Chris Boyd John Gaddie Deputy Fire Marshal Fire Protection Planning 530.538.6320 530.538.6320 Chris.boyd@fire.ca.gov john.gaddie@fire.ca.gov