HomeMy WebLinkAboutB18-1532 CF PC July 24, 2018 SMALLEY GENERAL CONTRACTING 6567 MILTON COURT MAGALIA, CA 95954 APN: 016-220-077 Building Permit Number: B18-1532 Plan Check #1 Description: OFFICE T.I. (1646) Occupancy Classification: B / U Fire Sprinklers: Yes Building Total Area: B @ 1646 sf / U @ 0 sf Dear Applicant, The plans you recently submitted have been reviewed by the Fire Department referencing the 2016 edition of the California Fire Code (CFC). The numbered comments listed below in the body of this letter must be addressed prior to Fire Department Approval of your project. Provide a full floor plan of the entire building. Include exit paths of travel on the floor plan. Provide occupant load calculation for Conference Room. Provide the location of all the required exit signs on the floor plan. Signs shall be illuminated at all times and be provided with backup power source that will allow the continuation of the illumination for 90 minutes in case of power failure. Emergency Illumination for egress pathway may be required. Clearly label and identify on plans firewalls, fire barriers, or fire partitions, along with their fire resistance ratings. Provide a minimum of (1) 2A20BC rated fire extinguisher mounted in an accessible conspicuous area for every 3000 square feet and the travel distance to a fire extinguisher shall not exceed 75 feet. Extinguishers must be mounted on a bracket or in a cabinet with the top not more than five feet above the floor. Extinguishers may be required to have a sign mounted above in order to be visible from a distance. Please note automatic fire sprinkler head locations on floor plan/reflected ceiling plan. Proposed tenant improvements may require modification or extension of the existing automatic fire sprinkler system. A C-16 licensed contractor (fire sprinkler contractor) shall be required to evaluate the current system design and installation with the proposed scope of work to determine if additions, alterations or deletion of fire sprinkler system components are required. If modifications to the fire sprinkler system shall affect 5 or less sprinkler heads, or if modifications are not required, please provide verification in the form of a scope letter from a C-16 licensed contractor (fire sprinkler contractor). The letter shall be drafted on company letterhead and include the contractor’s license number and stamp. The Fire Prevention Bureau is currently open to the public from 8:00 am to 5:00 pm. If you wish to discuss these plan check comments, please call during our business hours or e-mail at the address below. Permit status can be tracked by logging on to http://www.buttecounty.net/dds and clicking Building Permits Status. Chris Boyd John Gaddie Deputy Fire Marshal Fire Protection Planning 530.538.6320 530.538.6320 Chris.boyd@fire.ca.gov john.gaddie@fire.ca.gov