HomeMy WebLinkAboutB16-2471 CALFIRE FIRE ALARM INSPECTION3 -[to - o A,wz 1 6Ze1- (ic o381 AL&RM & 8E�JRITT, INC.T SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 11/30/16 Supplemental pages attached: 1. PROPERTY INFORMATION Name of property: Lundberg Building 8 Address: 5311 Midway Building #8 Description of property: Commercial Name of property representative: Address: Phone: Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installing contractor: Foothill Fire Alarm & Security, Inc. Address: 170 Erma Ct, Chico, CA 95928 Phone: (530) 826-3013 Fax: (530) 893-3013 E-mail: alarms@ffprotection.com Service organization: Foothill Fire Alarm & Security, Inc. Address: 170 Erma Ct, Chico, CA 95928 Phone: (530) 826-3013 Fax: (530) 893-3013 E-mail: alarms@ffprotection.com Testing organization: Foothill Fire Alarm & Security, Inc. Address: 170 Erma Ct, Chico, CA 95928 Phone: (530) 826-3013 Fax: (530) 893-3013 E-mail: alarms@ffprotection.com Effective date for test and inspection contract: 11/21/16 Monitoring organization: Foothill Fire Alarm & Security, Inc. Address: 170 Erma Ct, Chico, CA 95928 Phone: (530) 826-3013 Fax: (530) 893-3013 E-mail: alarms@ffprotection.com Account number: Z570101 Phone Zine 1/IP: 1 (844) 414-0165 Phone line 2/IP: 1 (844) 414-0165 Means of transmission: Cellular Entity to which alarms are retransmitted: Rapid Response Phone: (800) 932-3822 Page 1 of 4 3. DOCUMENTATION Onsite location of the required record documents and site-specific software: Document Box 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: ® New system ❑ Modification to existing system Permit number: 4.1 Control Unit Manufacturer: Potter Model number: PFC-6800 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification ® This system does not incorporate alarm verification Number of devices subject to alarm verification: Alarm verification set for seconds 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Power Primary Power Input voltage of control panel: 120 Control panel amps: 20 Overcurrent protection: Type: Circuit Breaker Amps: 20 Branch circuit disconnecting means location: Number: 5.1.2 Secondary Power Type of secondary power: Battery (2) 12V Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit ® This system does not have power extender panels ❑ Power extender panels are listed on supplementary sheet A Page 2 of 4 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line 1 X B 2 Device Power Waterproof Horn Strobe N/A N/A N/A Initiating Device N/A N/A N/A Notification Appliance 1 x B 2 Other (specify): N/A N/A N/A 7. REMOTE ANNUNCIATORS Type Location 8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Addressable Alarm N/A Smoke Detectors Waterproof Horn Strobe N/A N/A N/A Duct Detectors N/A N/A N/A Heat Detectors 1 Addressable Alarm Rate -of Rise Gas Detectors N/A N/A N/A Waterflow Switches 4 Addressable w/Modual Alarm N/A Tamper Switches 5 Addressable w/Modual Supervisory N/A 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible Combination Audible & Visible 2 Waterproof Horn Strobe Page 3 of4 10. SYSTEM CONTROL FUNCTION Type Quantity Hold -Open Door Releasing Device HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS ® This system does not have interconnected systems. ❑ Interconnected systems are listed on supplemental sheet 12. CERTIFICATION AND APPROVALS. 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: "Printed Name: Shane DeValera Date: 11/30/2016 Organization: Foothill Fire Alarm & Security, Inc. Title: Field Supervisor Phone: (530) 826-3013 12.2 System Operational Test This system as specified herein has been tested according to all NFPA standards cited herein. Signed: Printed Name: Shane DeValera Date: 11/30/2016 Organization: Foothill Fire Alarm & Security, Inc. Title: Field Supervisors Phone: (530) 826-3013 12.3 Acceptance Test Date and time of acceptance test: Date: J /G,- Time: %/x/4.4 Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: Page 4 of 4