Loading...
HomeMy WebLinkAboutB16-2249 CALFIRE FINAL INSPECTION B 16-2249 California Department of Forestry and Fir 039-210-035 ` Butte County Fire Departmen Fire Prevention Bureau i 176 Nelson Avenue, Oroville, CA 95965 (530) 538-7888 Office, (530) 538-2105 Fax Final Inspection Sheet Property Owners Name: HAMM MA yS i 1L Property Loc—action:�j`1S calco 5-1— City: Inspector: N- (rV tit:,12 Inspection Date: �i-1�' 1-7 Permit#--1lb"2 L / _APN# GCS -3 tf Ct IVO Correct Notes Mli 1273.02❑Roadway❑Driveway Surfaces 1273.03❑Roadway❑Driveway Grades /J1 1273.04❑Roadway❑Driveway Radius V / 1273.05❑Roadway❑Driveway Turnarounds ✓ 1273.06❑Roadway❑Driveway Turnouts 1273.07❑Roadway❑Driveway Structures 1273.08 One-Way Roads 1273.09 Dead-End Roads 1273.11 ❑Roadway❑Drivewa Gate Entrance .v<t•��::... ".0c19"�l.$4sI'/1l.N.Ui' , .�.... 1274.01.Size of Letters,Numbers and Symbols or Street and Roads Signs 1274.03.Height of Street and Road Signs 1274.05.Intersecting Roads,Streets and Private Lanes / 1274.06.Signs Identifying Traffic Access limitations 1274.07.Installation of Road,Street and Private Lane Si ps ------------- :�:{-0fkS• ., ih ''e{i t.:..�....:.....Y..i;a..ty.•.':: °k'#?,1n •.:t�m,n( ' I IL 1'(I i;'t M' �.ftr .S .t + »•?3?•y'a�� 1� 1 / 1 IIKIN"nuI 1274.08.Addresses for Buildings 1274.09.Size of Letters,Numbers and Symbols for Addresses I• 1274.10.Installation,Location and Visibilit of Addresses 1276.01 Setback for Structure Defensible Space Same Practical Effect Requirements for buildings less then 30 feet from property line 1276.02 Disposal of Flammable Ve etation and Fuels If re utred request to see a copy of the conversion ermit or Timber Harvest Plan r 704A.1.2 Roof coverings 704A.1.3 Roof valleys / 704A.1.5 Roof gutters / 704A2.2 Eave or cornice vents / 704A.2.3 Eave protection I / 704A.3.1.1 Exterior wall coverings 704A.3.2 Exterior wall openings I 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls / 704A.3.2.3 Exterior door assemblies / 704A.4.1.1 Decking surfaces / 704A.4.2.1 Underside of appendages and floor projections. 704A.4.2.2 Unenclosed under floor protection / Chapter 15 Roofing and Roof Structures 1503.1, 1503.2,1503.3 Roof Coverin within State Res onsibilit Area .t?>k??\ow'•:t?S'•?+;YY,•:: 3807.3,LPG Tank Clearance of Combustibles I / 3807.4 Protecting LPG containers from vehicles RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTQR 1st 3rd I U t YY 2nd / Inspection passed on: fV JAtAV The above sidential ❑ ancillary structure has been built to meet all applicable state and local fire safe standards including those standar s described in Government Code Section 51189(b). Inspector Signature