HomeMy WebLinkAboutB17-0736_047-780-040_CALFIRE INSPECTION Permit# B17-0736
Butte County Fire Department
Fire Prevention Bureau APN # 047-780-040
176 Nelson Avenue, Oroville CA 95965
(530)538-7888 Office,(530) 538-2105 Fax
Applicant Name: DENNIS DORVILLE CONSTRUCTION
Permit Address: 4123 TIBERON WAY, CHICO, CA 95926
Phone: 5308724401
Cell:
Under authority of Pubic Resources Code(PRC)Section 4290 and 4291,Butte County Improvement Standards(BCI S),
California Building Code(CBC),and the California Fire Code(CFC),and Chapter 38A Butte County Code,the following
items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local
Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be
superseded by Butte County local regulations exceeding these standards.
This pre inspection is for:
❑ Residence ❑ manufactured Home
❑ Addition to existing structure La' Ancillary Building(detached garage,shop,shed,etc.)
Public Resources Code 4290
ADMINISTRATION
1272. Maintenance of Defensible Space Measures
To ensure continued maintenance of properties in conformance with these standards and measures and to assure
continued availability,access,and utilization of the defensible space provided for these standards during a wildfire,
provisions for annual maintenance shall be included in the development pians and/or shall be provided as a condition of the
permit,parcel or map approval.
DRIVEWAY STANDARDS
7 10 Driveways
(a)All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code
4'' 0 roadway requirements. Driveways can only serve a single parcel.
Length of Driveway
(b)All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its
jenrelength.
2 Driveway Surface
The surface shall provide unobstructed access to conventional drive vehicles,including sedans and fire engines.
es should be established in conformance with local ordinances,and be capable of supporting a 40,000 pound load.4"
of c ass 2 aggregate base shall be required for all driveways, turnouts and turnarounds.
127 .03 Driveway Grades
The grade for all driveways shall not exceed 15%without being paved.Grades over 15%shall have 4"of class 2
a gate base and 2"of asphalt concrete.No driveways al lowed in excess of 20%.
127 .04 Driveway Radius
(a)No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4
f all be added to curves of 50-100 feet radius;2 feet to those from 100-200 feet.
(b)The length of vertical curves in roadways,exclusive of gutters, ditches,and drainage structures designed to hold or
divert water,shall be not less than 100 feet.
1
Legend:NIA=Not Applicable,X=Required
Revised on 04/10/17
Trakit Copy
1 73.05 DO way Turnarounds
(d)A t around shall be provided to all buildi sites on driveways over 300 feet in length,and shall be within 50
feet of the buildi .
Turnarounds a required on driveways a dead-end roads as specified in this article.The minimum turning radius for
a turnaround shall b 40 feet from the center li a of the road. If a hammerhead-T is used,the top of the"T"shall be a
minimum of 60 feet i length.
1273.06 Driveway Tu nouts
(c)Driveways ex eeding 150 fe in length,but less than 800 feet in length,shall provide a turnout near the midpoint
of the driveway.Where he drivewa exceeds 800 feet,turnouts shall be provided no more than 400 feet apart.
Turnouts shall be minim in of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end.
1273.07 Driveway Strue r s
(a)All driveway,ro ,street,and private lane roadway structures(Bridges,culverts, and other appurtenant structures
which supplement the rod ay bed or shoulders)shall be constructed to carry at least the maximum load and provide the
minimum vertical cle nce s required by Vehicle Code Sections 35550,35750 and 35250. All bridges shalt be certified
by a registered Civ' Engine r.
(b)Appro late signing, in ing but not limited to weight or vertical clearance limitations,one-way road or single
lane condition shall reflect the c ability of each bridge.
(c) ridge with only one tra is lane may be authorized by the local jurisdiction;however, it shall provide for
unobstru ed visibility from one end t he other and turnouts at both ends.
GA�TANDARDS
1273 Gate Entrance
(a)Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s)serving that gate.
/ Minimum 14 foot opening.
(b)All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall
open to allow a vehicle to stop without obstructing traffic on that road.
(c)Where a one-way road with a single traffic lane provides access to a gated entrance;a 40 foot turning radius shall
be used.
SIGNING AND BUILDING NUMBERING
1274.00.Intent
To facilitate locating an emergency and to avoid delays in response,all newly constructed or approved roads, street, and
buildings shall be designated by names or numbers,posted on signs clearly visible and legible from the roadway.This section
shall not restrict the size of letters of n umbers appearing on street signs for other purposes.
ADDRESSING
1274. .Addresses for Buildings
All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address
system.Accessory buildings will not be required to have a separate address;however,each dwelling unit within a building
shall be separately identified.
1274,09.Size of Letters,Numbers and Symbols for Addresses
/ Size of letters,numbers and symbols for addresses shall be a minimum 4 inch letter height,318 inch stroke,
reflectorzed,contrasting with the background color of the sign.
1274. Installation,Location and Visibility of Addresses
(a)All buildings shall have a permanently posted address,which shall be placed at each driveway entrance and visible
from both directions of travel along the road. In all cases,the address shall be posted at the beginning of construction and
shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located.
2
Legend:NIA=Not Applicable,X=Required
Revised on 04/10/17
Trakit Copy
ADDRESSING(cont.)
{b)Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite
dir ctio
{c)Where multiple addresses are required at a single driveway,they shall be mounted on a single post.
FUEL MODIFICATION STANDARDS
1276.00 Intent
To reduce the intensity of a wildfire by reducing the volume and density of flammable vegetation,the strategic location of
fuel modification and greenbelts shall provide:
(1)Increased safety for emergency fire equipment and evacuating civilians;
(2)A point of attack or defense from a wildfire.
1276.01 Setback for Structure Defensible Space SRA only
[ ] k4—(aAII parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from
all property lines and/or the center of the road.
1276.921J4sposal of Flammable Vegetation and Fuels
Disposal,including chipping,burning or removal to a landfill site approved by the local jurisdiction,of flammable
vegetation and fuels caused by site development and construction,road and driveway construction,and fuel modification
shall be completed prior to completion of road construction or final inspection of a building permit.
DEFEN IBLE SPACE GUIDELINES
Publ' esources Code 4291
A person that owns,leases,controls,operates,or maintains a building or structure in,upon,or adjoining any
mountainous area,forest-covered lands,brush-covered lands,grass-covered lands,or any land that is covered with flammable
material shall at all times do all of the following:
(b)Maintain around and adjacent to the building or structure additional fire protection or firebreak made by removing
al brush,flammable vegetation,or combustible growth that is located within 100 feet from the building or structure or to the
property line or at a greater distance if required by state law, or local ordinance,rule,or regulation.Grass and other
vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be
maintained where necessary to stabilize the soil and prevent erosion.This subdivision does not apply to single specimens of
trees or other vegetation that is well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly
trans�m mg fire from other nearby vegetation to a dwelling or structure.
✓ (c)Remove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe.
�)Maintain any tree adjacent to or overhanging a building free of dead or dying wood.
Maintain the roof of a structure free of leaves,needles,or other dead growth,
ve ve etati
g
�'((fno)Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an
area,the construction or rebuilding of which requires a building permit,the owner shall obtain a certification from the local
building official that the dwelling or structure,as proposed to be built, complies with all applicable state and local building
standards, including those described in subdivision(b)of Section 51189 of the Government Code,and shall provide a copy
of the certification,upon request,to the insurer providing course of construction insurance coverage for the building or
structure. Upon completion of the construction or rebuilding,the owner shall obtain from the local building official,a copy of
the final inspection report that demonstrates that the dwelling or structure was constructed in compliance with all applicable
state and local building standards,including those described in subdivision(b)of Section 51189 of the Government Code,
and shall provide a copy of the report,upon request,to the property insurance carrier that insures the dwelling or structure.
3
Legend.N/A=Not Applicable,X=Required
Revised on 04110/17
Trakit Copy
Pqblic Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only
or to any lot clearing activity or cutting of trees,contact the Butte area Forester at(530)872-6353 to determine the
J_V�P
need for a less then 3 acre conversion exemption permit or a timber harvest plan.If required,a copy of the Timber Harvest
Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection.
❑ it required
Permit not required
2016 California Fire Code
LPG Tanks
6107.3„ G Tank Clearance of Combustibles
Weeds,grass,brush,trash and other combustible materials shall be kept a minimum of 10 feet from LP-gas tanks or
containers.
6107.4 Wotecting LPG containers from vehicles
here exposed to vehicular damage due to proximity to alleys,driveways or parking areas, LP-gas containers,
regulators and piping shall be protected in accordance with Section 312.
Fire rtment Fees
Fire department fees are collected by the Butte County Development Services Department at the time of application for
your building permit. You are assessed two fees(pre-inspection and final inspection). Additional fees will be assessed when
the fire department inspector is required to perform additional re-inspections of your property,those
additional fees must be paid to Development Services,7 County Center Drive in Oroville.
California Building Code Chapter 7A,
Materials and Construction Methods for Exterior Wildfire Exposure
Check with Butte County Department of Development Services Building Division for specific questions regarding
Chapter 7A of the California Building Code and its application to your project. Also,check the websites below for
useful information including the full text of Chapter 7A CBC.
All of the Fire Safe Requirements, including
Wildland Urban Interface (WUI) Products from the Office of the State Fire Marshal's office
are posted on the Butte County Fire Department website at
httjR://www.buftecounll.net/fire
Check the status of your pertnit online at
http://dspermits.buttecounty.inet/etrakit/Permit—Seareli.asp
Need afire department inspection? Call our inspection line.
(530) 538-6226
' _
Inspector Date Prt►�peFty Owner or Contracfo4 signature
Thomas_ Lewis
Owners blame
4
Legend:NIA=Not Applicable,X=Required
Revised on 04/10/17
Trakit Copy
California Department of Forestry and Fire Protection
Butte County Fire Department
Fire Prevention Bureau
176 Nelson Avenue, Oroville, CA 95965
(530) 538-7888 Office, (530) 538-2105 Fax
Final Inspection Sheet
Property Own rsAamc: ZI t A�o dij j,, A _--Properly roperly Location: City:
Inspector: 7LAkV' Inspection Date: (7 —1 Permit# J' � 07-3i> APNvr)ZI-7 Dvf)
Correct Notes
OWN,�* M'11'ffl P
1-�1-RSMffP!1'VKM' MOWN OA M'r ffi. ft M, ME IV m M I
1273.02 0 Roadway T"Driveway"Surfaces
1273.03 0 Roadway El Driveway Grades
1273.04 El Roadway El Driveway Radius
1273.05 0 Roadway[I Driveway Turnarounds
1273.06 0 Roadway El Driveway Turnouts
1273.07 D Roadway 11 Driveway Structures
1273.08 One-Way Roads
1273.09 Dead-End Roads
1273.11 0 Roadway 0 Driveway Gate Entrance
1274.01.Size of Letters,Numbers and Symbols for Street and Roads Signs
1274.03.Height of Street and Road Signs
1274.05.Intersecting Roads,Streets and Private Lanes
1274.06.Signs Identifying Traffic Access limitations
1274,07.Installation of Road.S i rect and Pri vale Lane Si s
'M
EMMMUMN . .. ......... .. ...........
1274.08.Addresses for Buildings
1271.109.Size of Letters,Numbers and Symbols for Addresses
Numbers
on,L
's.b']
�Addresses 1274.10.Installation,Location and&Visibi lily of Addresses
ry. 1276.01 Setback for Structure Defensible Space
Same Practical Effect Requirements for buildings less then 30 feet from property line
1276.02 Di, os I of Flammable Vegetation and Fuels
W4
RIS ft- 3 6 Mtr I 'W
If re uired,rme9quesl to see a co ofthe.conversion ennit or Timber I lancsi Man
�cs o see a co
M.
704A.1.2 Roo fcoverings
704A.1.3 Roof valleys
704A.1.5 Roof gutters
704A2.2 Eave or cornice vents
704A.2-3 Eave protection
704A.3.1.1 Exterior wall coverings
704A.3.2 Exterior wall openings
11 704A.3.2.1 Exterior wall vents
704A.3.2.2 Exterior glazing and window walls
704A.3.2.3 Exterior door assemblies
704A_4_1.1 Decking surfaces
704A.4.2.1 Underside of appendages and floor projections.
704A.4.2.2 Unenclosed under floor protection
Chapter 15 Roaring and Roof Structures
1503.1. 1503.2. l503.3.Ro?ofCovcn' within State Responsibility Area
. �ovcrm within:�131C
,I- Cov wi.,31 bi;&A
3807.3,LPG Tank Clearance of Combustibles
3807.4 Protecting LPG containers from vehicles
RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR
1St 3rd I A I
2nd
I Inspection passed on: -4- �) . C (7 0 L.L-f r,
The above 11 residential 01ancillarystructure has been built to meet all applicable state and local fire safe standards including those
standards described in Government Code Section 51189(b).
ln�spt—o�Sjgnaturc
�