Loading...
HomeMy WebLinkAboutADM21-0112 Approved(Permit Requirements – Reverse) 1 of 2 SOLAR ENERGY FACILITY TIER 2 - ACCESSORY UTILITIES ADMINISTRATIVE PERMIT (BCC 24-157 et seq.) APPLICANT INFORMATION APPLICANT’S NAME PHONE NUMBER ( ) MAILING ADDRESS CITY STATE ZIP CODE E-MAIL PROPERTY INFORMATION PROPERTY OWNER (if different from the applicant) ASSESSOR’S PARCEL NUMBER SITE ADDRESS CITY ZIP CODE SIZE OF PROPERTY EXISTING LAND USES TOTAL ENERGY OUTPUT (KW) PHOTOVOLTAIC SYSTEM COVERAGE AREA (SQ FT./ACRES) PERCENTAGE OF ENERGY FOR ON-SITE USES DESCRIPTION OF PROPOSED FACILITY (use separate sheet, if necessary) APPLICANT’S ACKNOWLEDGEMENT I certify that all of the information submitted is true and correct to the best of my knowledge. I have read and acknowledge the permit requirements as set forth below (page 2) and agree to comply with them. I further understand that should the facility be modified or if the use expands beyond the requirements of this permit, that I will notify the county to obtain any necessary approvals. APPLICANT’S SIGNATURE DATE STAFF USE ONLY APPLICATION REVIEWER ZONE DISTRICT EH CLEARANCE YES  NO  N/A PUBLIC WORKS CLEARANCE YES  NO  N/A PROJECT NUMBER ADM_____-_________ BUILDING PERMIT REQUIRED? YES  NO  N/A BUILDING PERMIT NUMBER B_____-_________ ZONING ADMINISTRATOR APPROVAL DATE Butte County Department of Development Services PLANNING DIVISION 7 County Center Drive, Oroville, CA 95965 Planning Center Phone 530.552.3701 Fax 530.538.7785 dsplanning@buttecounty.net FORM NO PLA-27 TEW AG-160 (CLCA)x x x 21 224421 0112 7783 Aguas Frias Road 8/27/2021 2 of 2 SOLAR ENERGY FACILITY PERMIT REQUIREMENTS 1.The solar electric facility shall be limited to ground-mounted systems encompassing less than 15percent of the parcel’s size up to 5-acres, whichever is less. 2.More than 50 percent of the power generated shall be used for on-site primary and accessory uses.Less than 50 percent of the power generated may be used off-site. 3.Photovoltaic panel systems shall meet all applicable performance standards established by theNational Electrical Code, the Institute of Electrical and Electronics Engineers, and the Public Utilities Commission regarding safety and reliability. 4.Ground-mounted photovoltaic panel systems shall meet all setback areas of the applicable zone. 5.Height, Parcel Size and Setback for ground-mounted photovoltaic panel systems shall be inaccordance with Table 24-157-2 of the Butte County Zoning Ordinance. 6.If the solar energy facility is located on or adjacent to an agricultural zone, the applicant must acknowledge the County’s Right to Farm Ordiance and shall record a Right to Farm Notice on theirparcel prior to issuance of any building permits. 7.For solar energy facilities in Scenic areas, as designated in the General Plan (Figures COS-7 and COS-9, Conservation and Open Space Element), efforts shall be made by the owner/applicant, to themaximum extent practicable, to shield the solar energy facility from public view. On-sitetransmission and power lines shall, to the maximum extent practicable, be placed out of sight or underground. 8. A solar energy facility that ceases to produce electricity on a continuous basis for 24 months shallbe considered abandoned unless the property owner/developer demonstrates by substantial evidencesatisfactory to the Develoment Services Department that there is no intent to abandon the facility.Parcel owners shall remove all equipment and facilities, and restore the site to its original condition,when a facility has been deemed abandoned. 9.This Administrative Permit is valid only when accompanied by a copy of the approved site plan. 10.The Zoning Administrator may revoke its approval of this Administrative Permit, if any of thefollowing applies: a.The applicant or property owner has altered the circumstances under which the permit was granted to a degree that one or more of the findings required to grant the original permit can nolonger be made; b.Permit issuance was based on misrepresentation by the applicant through the omission of amaterial statement in the application; c.One or more of the permit conditions of approval have not been complied with or fulfilled; d.The applicant or property owner has failed or refused to allow inspections for compliance; e.Improvements authorized by the permit are in violation of the Zoning Ordinance or any law,ordinace, regulation, or statute; or f.The use is being operated in a manner which constitutes a nuisance. ______________ Applicant’s Initials 2 50VA Transformer 277V 1PH to 120V 1PH #12 Nema-3R enclosure w/ 120V power for monitoring Communications cabling from Data Manager to inverter(s) 15A finger safe fuse DC power supply 60VA, 2.5A, 24V SMA Data Manager 2.5A, 24V DCennexOSDATA MANAGER SMADigitalInputX3RS485X2X4X5X210-30VDC- + Panel 'PV' 600A, 277/480V, 3∅, 4W, N-3R 5 GRD A NEUTRAL BC 3 6 Inverter 'A' SMA AMERICA STP 50-US-41 3 3 1 #8 3 2 strings of 19 REC380TP2SM72 380W PV Solar Panels ( Strings 1-2 ) 4 3 3 34 1 Inverter 'C' 3 3 1 #8 3 4 3 3 34 1 3 SMA AMERICA STP 50-US-41 B CB JF HK B CB JF HK L 2 strings of 19 REC380TP2SM72 380W PV Solar Panels ( Strings 3-4 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 5 ) Inverter 'F' 3 3 1 #8 3 4 3 3 34 1 3 SMA AMERICA STP 50-US-41 C C B J F HK 3 Inverter 'B' SMA AMERICA STP 50-US-41 3 3 1 #8 3 4 3 3 34 1 Inverter 'D' 3 3 1 #8 3 4 3 3 34 1 3 SMA AMERICA STP 50-US-41 B CB JF HK B CB JF HK Inverter 'E' 3 3 1 #8 3 4 3 3 34 1 3 SMA AMERICA STP 50-US-41 C C B J F HK At ArrayAt Meter M G (E) (E) 2000A, 277/480V, 3ph, 4W Meter Panel (E) LoadsPoint of Connection Line Side Connection AC Disconnect Cutler-Hammer #DH366NRK 600A, 600V w/ (3) 600A fuses G 2A N 44 1 BM DA 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 8 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 7 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 6 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels ( Strings 9-10 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 11-12) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 13 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 16 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 15 ) 1 string of 19 REC380TP2SM72 380W PV Solar Panels ( String 14 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 17-18) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 19-20) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 21 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 24 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 23 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 22 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 25-26) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 27-28) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 29 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 32 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 31 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 30 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 41-42) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 43-44) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 45 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 48 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 47 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 46 ) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 33-34) 2 strings of 19 REC380TP2SM72 380W PV Solar Panels (Strings 35-36) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 37 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 40 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 39 ) 1 string of 18 REC380TP2SM72 380W PV Solar Panels ( String 38 ) Panel Type Angle of Inclination Azimuth Angle Total # of Panels Total KiloWatts System Layout Info. Panel Tilt Total # of Inverters Meter Input (DC) Maximum Array Power Max. DC voltage Rated MPPT voltage range MPPT operating voltage range Min. DC voltage/start voltage Number of MPP tracker inputs/strings per MPP input Max. input current/per MPP tracker input AC nominal power Max. AC apparent power AC voltage range Rated AC grid frequency Max. output current Power factor at rated power/adjustable displacement Max. efficiency CEC efficiency SMA AMERICA Output (AC) Output phases/line connections Nominal AC voltage Harmonics Efficiency General data Dimensions (WxHxD) Weight Operating temperature range Topology 75000Wp STC 1000V 500V-800V 150V-1000V 150V/188V 6/2 120A/20A 50000W 53000VA 244V-305V 60Hz 64A 1/0.0 lead-0.0 lagg >98% >98% 3/3-N-PE, 3-PE 480/277V WYE <3% STP 50-US-41 24.4"x28.8"x22.4" 180lbs -25°C - +60°C Transformerless Model Name Nominal Power (PMPP) Watt Class Sorting Nominal Power Voltage (VMPP) Nominal Power Current (IMPP) Open Circuit Voltage (VOC) Short Circuit Current (ISC) Panel Efficiency Max System Voltage Fuse rating REC Solar Module Dimensions in Inches REC380TPSM72 380W 0/+5 40.3V 9.43A 48.0V 10.05A 18.9% DC 1000V 25A 78.9 x 39.4 x 1.2 Temperature Coefficient -0.37%/°C - 180° 896 340.48kW DC 30° 6 1010241382 REC380TP2SM72 7 Photovoltaic Labeling WARNING DUAL POWER SUPPLY PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC "AC" DISCONNECT PHOTOVOLTAIC "DC" DISCONNECT CAUTION: SYSTEM CONNECTED SOLAR ELECTRIC CAUTION: SOLAR CIRCUIT CAUTION: SOLAR CIRCUIT PHOTOVOLTAIC DISCONNECT OPERATING CURRENT:AMP SHORT CIRCUIT CURRENT:AMP OPERATING VOLTAGE:VDC MAXIMUM SYSTEM VOLTAGE:VDC DC OPERATING VOLTAGES AND MAXIMUM PERMISSIBLE SYSTEM VOLTAGE ACCORDING TO INVERTER RATING PLATE. PHOTOVOLTAIC DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. SOLAR INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING DC TERMINALS ON ARRAY SIDE MAY BE ENERGIZED EVEN WHEN DISCONNECT IS IN OPEN-CIRCUIT POSTITION. CHECK VOLTAGE AT TERMINALS BEFORE REMOVING CONNECTIONS. UNPLUG MODULES TO COMPLETELY REMOVE UNIT. SEE MANUAL FOR MORE INFORMATION. WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. Provide permanent plate on exterior of main electrical panel: Provide permanent plate on external AC Disconnect: Provide permanent plate on either an external or inverter integrated lockable DC Disconnect: Provide caution sticker on inside of Main Electrical Panel: Provide caution sticker on all DC Combiner Boxes and/or Junction Boxes: Provide caution sticker on all interior and/or exterior conduit & raceways every 10 feet, at turns and, above & below all penetrations: Provide plaques on inside of DC Dicsonnect: Provide plaque at dedicated circuit breaker: Provide plaque near ground fault indicator on Inverter: Provide plaque at each junction box, combiner box, disconnect and device where circuits may be exposed during service: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PV SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Provide plaque at each solar AC combiner panel: Solar Combiner Only NO BREAKERS MAY BE ADDED TO THIS PANEL. IT IS NOT TO BE USED FOR POWER DISTRIBUTION TO ANY CUSTOMER LOADS PV INPUT ONLY Provide sticker at PV system power disconnect: "All labels and warnings to comply with NFPA 70, NEC 2017, CEC 2019 and Article 690 SOLAR PHOTOVOLTAIC SYSTEMS" "All permanent plates are "RED" plastic with "WHITE" engraved lettering to be fastened with 1/8" rivets" "All caution stickers are made of a reflective & water resistant material (UL 969) with "RED" background and 3/8" "WHITE" (capital) lettering" "All plaques are "WHITE" plastic with "BLACK" engraved lettering to be attached with adhesive backing" A B C D E F G H J K L M All wiring to conform to 2019 California Building Code (CBC), 2019 California Fire Code (CFC), 2019 California Green Building Standards Code & 2019 CEC and 2017 NEC Article 690 - Solar Photovoltaic System. Provide ground-fault protection at inverter per NEC 690.5. Bond all exposed non-current-carying metal parts of PV system together and to existing building ground per NEC 690V. Inverter shall be interactive and shall de-energize its output to the connected electrical production and distribution network upon loss of voltage in that system and shall remain in that state until the electrical production and distribution network voltage has been restored. Provide labeling of PV system per NEC 690. Installation shall also conform to NEC Article 705 - Interconnected Electrical Power Production Sources. CEC section 690.51/690.53 Provide marking on modules for (1) open-circuit voltage, (2) operating voltage, (3) maximum permissible system voltage, (4) operating current, (5) short-circuit current, (6) maximum power and at photovoltaic power source (solar string combiners) (1) operating current (2) operating voltage (3) maximum system voltage (4) short-circuit current. SMA AMERICA transformerless inverters utilize a floating DC array (ungrounded) all wiring to meet the requirements of NEC 690.35. Overcurrent protection is to be provided in both positive and negative conductors. Array conductors to be rated at 600volts and be identified as "PV Wire". Ground fault protection shall be in both positive and negative conductors. All junction box, combiner box, disconnect or other device where energized, ungrounded circuits may be exposed during service shall have the following label "WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." General Notes 1. 2. 3. 4. 5. 6. 7. 8. Solar System Point of Connection shall be on the line side of the main service disconnecting means as per NEC 705.12 and 230.82. Provide Nema-3R, 600A disconnect (Cutler-Hammer #DH366NRK) with 600A fuses (Littelfuse #KLSR600 or approved equal). #10 copper ground will be used in an equipment ground to connect the module frames. Use only the indicated location on the module or the warranty may be invalidated. Follow the rack manufacturer's instructions on bonding of the module racking. 5/8" x 8'-0" copper clad ground rod with #6 AWG Cu. conductor landing in an approved lug on the structure per NEC 690-47(d). Supplemental Ufer ground to be installed at Panel 'PV'. Install 20' of #1/O bare copper encased in concrete 36" below grade. Bond to existing service ground. See Detail D of sheet E-2. Solar AC Combiner Panel. Identify with a permanent placard that it is not to be used for power distribution to any customer loads. 1 2 3 Sheet Notes 4 5 6 1 2 3 Feeder Schedule 4 #10 AWG Cu. PV wire, 2 per String, #10 Cu. GRD. 1/2"C. w/ (2) #12 THWN-2 Cu., #12 THWN-2 Cu. GRD. 1 1/4"C w/ (3) #3 THWN-2 Cu., PARALLEL 4"C w/ (3) #750MCM THWN-2 Al., #1/O THWN-2 Cu. Neutral, #1/O THWN-2 Cu. GRD. EACH #8 THWN-2 Cu. Neutral, #8 THWN-2 Cu. GRD. Disconnect Labels A AC Output Current 384A Nominal AC Voltage 480V B INPUT #1 INPUT #2 INPUT #3 INPUT #4 INPUT #5 INPUT #6 MPP Current 9A Max System Current 13A C INPUT #1 INPUT #2 INPUT #3 INPUT #4 INPUT #5 INPUT #6 MPP Current 9A Max System Current 13A MPP Current 9A Max System Current 13A MPP Current 9A Max System Current 13A MPP Current 19A Max System Current 25A MPP Voltage 766V Max System Voltage 983V MPP Current 19A Max System Current 25A MPP Voltage 766V Max System Voltage 983V F MPP Voltage 766V Max System Voltage 983V MPP Voltage 766V Max System Voltage 983V MPP Voltage 766V Max System Voltage 983V MPP Voltage 766V Max System Voltage 983V MPP Current 9A Max System Current 13A MPP Current 9A Max System Current 13A MPP Current 9A Max System Current 13A MPP Current 9A Max System Current 13A MPP Current 19A Max System Current 25A MPP Current 19A Max System Current 25A MPP Voltage 725V Max System Voltage 932V MPP Voltage 725V Max System Voltage 932V MPP Voltage 725V Max System Voltage 932V MPP Voltage 725V Max System Voltage 932V MPP Voltage 766V Max System Voltage 983V MPP Voltage 766V Max System Voltage 983V VOLTS, AMPS, GROUNDING, OVERCURRENT PROTECTION: WIRE RUN AND CONDUIT LEGEND: (TYPICAL OF ONE) Current Carrying Amps Amps Amps Max w/ NEC Multiplier Fuse or Breaker Amps Voltage Max VOC Min VMP DC/ ACQty AWG (IMP)(ISC) One Way Dist. (ft) Design Vdrop (<)_ Grounding Conductors Qty Qty EGC AWG GEC AWG Worst Case Vdrop ARRAY TO INVERTER 1 CONDUCTORS ARE (2) #10 AWG PV WIRE (1000V RATED). FREE AIR UNDER ARRAY GROUND IS #10 AWG THWN-2 BARE CU. 2 COMMUNICATION BOX TO PANEL 'PV' CONDUCTORS ARE (2) #12 AWG THWN-2 Cu. IN 1/2" CONDUIT GROUND IS #12 AWG THWN-2 CU. MAXIMUM ALLOWABLE SOLAR BACKFEED BREAKER CALCULATION: -X -A Bussing A Main Breaker--- - N/A = = Amps Backfeed Breaker Typical of One: For Module:For Array: Voc Vmp 40.3V 48.0V VMPP VOC Total For System: 340,480 Watts STC Voc Isc Vmp Imp 19A 25A 766V 983V Max System Voltage MPP Voltage Max System Current MPP Current Total For System: 340,480 Watts STC 3 INVERTER 'A', 'B', 'C', 'D', 'E', & 'F' TO PANEL 'PV' CONDUCTORS ARE (3) #3 AWG THWN-2 Cu. IN 1 1/4" CONDUIT GROUND IS #8 AWG THWN-2 CU. 2 10 9.43 10.05 10.50 25.00 766.0 983.0 125DC 2.1% 1 10 0.30% 2 12 00.26 15.00 20DC 2.1% 1 12 0.01% 18 3 100 x 0.82 = 82 80 80.00 480 135AC 2.1% 6 8 1.00%1 8 Total DC Vdrop Total AC Vdrop 1.80% 0.31% Avg Ambient Temp (F) 95 Min Historical Temp (F) 21 Correction Factor 310.15(B)(2)a 0.82 480 Correction Factor 310.15(B)(2)c Does not apply 0.67 25 x 0.82 = 20.5 PGE CEC AC: 311.963kW 1 2 3 Feeder Schedule 4 #10 AWG Cu. PV wire, 2 per String, #10 Cu. GRD. 1/2"C. w/ (2) #12 THWN-2 Cu., #12 THWN-2 Cu. GRD. 1 1/4"C w/ (3) #3 THWN-2 Cu., 6 750 770 x 0.82 = 631.4 479.3 600 480 10AC 2.1% 2 1/O 0.80%1 2/O 4 PANEL 'PV' TO DISCONNECT TO INTERCONNECTION CONDUCTORS ARE PARALLEL (3) #750 AWG THWN-2 Al. IN 4" CONDUIT GROUND IS #1/O AWG THWN-2 CU. PARALLEL 4"C w/ (3) #750MCM THWN-2 Al., #1/O THWN-2 Cu. Neutral, #1/O THWN-2 Cu. GRD. EACH #8 THWN-2 Cu. Neutral, #8 THWN-2 Cu. GRD. A THREE LINE DIAGRAM N.T.S. No. 1 2 3 ENGR: DRAWN: CHECKED: PROJECT #: DateSLA T A OET CF I INROF AIUBNGISE DROTCA R TNOCDL NO. 454345 Exp. 04/30/22 ELEOCIHC CI R TC CIRTC E LE 10-CLA Issue Drawings and written material appearing herein constitute originaland unpublished work of Chico Electric and may not be duplicated,used or disclosed without prior written consent of Chico Electric. 4 www.chicoelectric.com Solar Energy 5 6 BLDG. SUBMITTAL: DRAWING DATE: Electrical Contracting Service STAMP E-1 7/27/21 RS JP RS 19-4645 - Fenn Farms Durham, CA 95938 038-110-019-000 39.587493° -121.858551° 7/27/21 M 4 (N) AC Disconnect (E) Meter Panel 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 44 43 42 41 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 36 35 34 33 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 20 19 18 17 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 16 15 14 13 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 24 23 22 21 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 32 31 30 29 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 37 38 39 40 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 48 47 46 45 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 28 27 26 25 5 5 5 5 5 5 5 5 5 5 5 5 Inverter 'A'Panel 'PV' Inverter 'B' Inverter 'C' Inverter 'D' Inverter 'E' Inverter 'F' ARE UNGROUNDED AND MAY BE ENERGIZED." Solar System Point of Connection shall be on the line side of the main service disconnecting means as per NEC 705.12 and 230.82. Provide Nema-3R, 600A disconnect (Cutler-Hammer #DH366NRK) with 600A fuses (Littelfuse #KLSR600 or approved equal). #10 copper ground will be used in an equipment ground to connect the module frames. Use only the indicated location on the module or the warranty may be invalidated. Follow the rack manufacturer's instructions on bonding of the module racking. 5/8" x 8'-0" copper clad ground rod with #6 AWG Cu. conductor landing in an approved lug on the structure per NEC 690-47(d). Supplemental Ufer ground to be installed at Panel 'PV'. Install 20' of #1/O bare copper encased in concrete 36" below grade. Bond to existing service ground. See Detail D of sheet E-2. Solar AC Combiner Panel. Identify with a permanent placard that it is not to be used for power distribution to any customer loads. 1 2 3 Sheet Notes 4 5 6 1 2 3 Feeder Schedule 4 #10 AWG Cu. PV wire, 2 per String, #10 Cu. GRD. 1/2"C. w/ (2) #12 THWN-2 Cu., #12 THWN-2 Cu. GRD. 1 1/4"C w/ (3) #3 THWN-2 Cu., PARALLEL 4"C w/ (3) #750MCM THWN-2 Al., #1/O THWN-2 Cu. Neutral, #1/O THWN-2 Cu. GRD. EACH #8 THWN-2 Cu. Neutral, #8 THWN-2 Cu. GRD. 5/8" x 8' Copper Clad Ground Rod Approved Clamp #6 AWG Copper Ground Wire Approved Lug on Rack 6" concrete slab #4 RebarBare copper conductor minimum 2" concrete encasement Concrete form 10'-6"24"Note: 1. Concrete encased electrode to meet requirements of NEC 250.52(3) Native Fill Warning Tape Feeder conduit 12" sand 6" sand ground level 30"Bare copper conductor 6" concrete slab PLAN VIEW N.T.S. ELEVATION N.T.S. A SITE ELECTRICAL PLAN 1" = 50'-0" N B PV ELECTRICAL & STRINGING PLAN 1" = 20'-0" N No. 1 2 3 ENGR: DRAWN: CHECKED: PROJECT #: DateSLA T A OET CF I INROF AIUBNGISE DROTCA R TNOCDL NO. 454345 Exp. 04/30/22 ELEOCIHC CI R TC CIRTC E LE 10-CLA Issue Drawings and written material appearing herein constitute originaland unpublished work of Chico Electric and may not be duplicated,used or disclosed without prior written consent of Chico Electric. 4 www.chicoelectric.com Solar Energy 5 6 BLDG. SUBMITTAL: DRAWING DATE: Electrical Contracting Service STAMP C ARRAY GROUNDING DETAIL N.T.S. D UFER GROUNDING DETAIL N.T.S. E-2 7/27/21 RS JP RS 19-4645 - Fenn Farms Durham, CA 95938 038-110-019-000 39.587493° -121.858551° 7/27/21 8'-9" 17'-6" 26'-3" 35'-0" 43'-9" 52'-6"61'-3"70'-0" 78'-91 8" 87'-618" 96'-31 8" 105'-018" 113'-91 8" 122'-618"5'-838"19'-238"4'-212" 8'-11" 17'-10" 26'-878" 35'-77 8" 44'-678" 53'-57 8" 62'-47 8" 71'-378" 80'-23 4" 89'-134" 98'-03 4"106'-1134" 115'-1034" 1'-0" 1'-7"3'-2"1'-6"9'-012"5'-10"3'-2"5'-8 3 8"3"3"112" - 2"112" single socket tee, typical Grainger #4NXU8 U-bolt assembly, typical Pro Solar #240-0178 11 2" single swivel socket, typical Grainger #4NXW4 164" PV Rail Pro Solar #210-0600 112" schedule 40 steel pipe, typical PV module, typical finished grade undisturbed earth undisturbed earth undisturbed earth *Use 2,500psi concrete min. No. 1 2 3 ENGR: DRAWN: CHECKED: PROJECT #: DateIssue Drawings and written material appearing herein constitute originaland unpublished work of Chico Electric and may not be duplicated,used or disclosed without prior written consent of Chico Electric. 4 www.chicoelectric.com Solar Energy 5 6 BLDG. SUBMITTAL: DRAWING DATE: Electrical Contracting Service STAMP S-1 7/26/21 ZM JP RS 19-4645 - Fenn Farms Durham, CA 95938 038-110-019-000 39.587493° -121.858551° 95'2440'110'(E) Storage/Silos (E) Office Proposed Location of (N) Solar Array(s)Aguas Frias Road5207'5202'5200' 5153' 7/27/21 JP RS As Noted 19-4645 Durham, CA 95938 038-110-019-000 Plot A PLOT PLAN 1" = 1000'-0" N Fenn Farms Drawings and written material appearing herein constitute original and unpublished work of Chico Electric and may not be duplicated, used or disclosed without prior written consent of Chico Electric. DATE: DRAWN: CHECKED: PROJECT: SCALE: SHEET:Address: APN: ELECTRICAL CONTRACTING, SOLAR ENERGY & SERVICE Fax: (530) 891-6749 36 W. Eaton Road Chico, CA 95973 www.chicoelectric.com Office: (530) 891-1933SLA T A OET CF IINROF AIUBNGISE DROTCA R TNOCDL NO. 454345 Exp. 04/30/22 ELEOCIHC CI R TC CIRTC E LE 10-CLA 7/27/21