HomeMy WebLinkAboutB21-2756 CF FA 2021 FIRE ALARM INSPECTION AND TESTING FORM Date: . SERVICE ORGANIZATION FACILITY LOCATION Name: California Safety Company, Inc. Name: Huckleberry's Address: 1410 Elmwood Street Address: 1586 HWY 99 City/State/Zip: Redding, CA 96001 City/State/Zip: Gridley, CA Telephone: (530) 243-2521 Telephone: 797-2002 License #: 266257 Account#: 40071 MONITORING AGENCY APPROVING AGENCY (AHJ) Contact: California Safety Company, Inc. Contact: Redding Fire Department Telephone: (530) 243-2521 Telephone: (530) 225-4572 Testing: Annual TYPE OF TRANSMISSION __None (Local Only) Digital Communicator (DACT) Manufacturer/Model: Telguard TG-7FS LTE DE•ect Line Voltage: 12 VDC xCellular Communicator CELL POWER LOCATION: C:-/--/ANTENNA LOCATION: ///(- 1-,i( Monitoring Station Signal by 90 Seconds: Alarm: Yes No N/A Supervisory/Trouble: AYes No N/A Dialer Phone Line #1 Trouble by 4 Minutes: FA es No —N/A • Dialer Phone Line #2 Trouble by 4 Minutes: Yes _No —IN/A MAIN FIRE CONTROL PANEL CHECKS-Kitchen Storage Conlfol Panel Manufacturer: Honeywell Model: Vista 32FB Voltage: 12 VDC Initiating Circuits/ SLC Class Used: 5/B Indicating Circuits/Class Used: 2/B Static Battery Voltages/Size/Dates: fg Date,20/5- Inst Date 2/5 Battery Under Load Test: 9*C AC Circuit Breaker Location: fi?..E.,e/ 0'1 10&/ Trouble Signal with AC Power Off: gYes _No —N/A Circuits Operate on Standby Battery: Yes No I IN/A Circuits Checked for Supervision: Yes [—No —N/A Circuits Trouble on Ground Fault: LYes _No— I IN/A Sprinkler Delay Time: Yes No RV/A Lockout Tag#'s Lamps/LED's: Yes _No N/A Panel Key on Site: Yes No I IN/A Operating Instructions at Annunciator/FACPMYes —No PN/A Test/Service Records at Fire Panel: Yes I INo I IN/A AUXILIARY PANEL CHECKS— Cellular Communicator Panel Manufacturer: Honeywell Model: Telguard TG-7FS LTE Voltage: 12 VDC Static Battery Voltages/Size/Dates: /;"/,' ./,- xiC„.,7-..-c Mfg Date H7 Inst Date --)...oie Battery Under Load Test: k, x:,— f.4 r AC Circuit Breaker Location: Same as eACP Trouble Signal with AC Power Off: A Yes -No N/A Circuits Operate on Standby Battery: II Yes No _N/A Lamps/LED's: Yes _-No N/A Panel Key on Site: Yes No N/A AUXILIARY PANEL CHECKS Location: —' /---": --(- Panel Manufacturer: Notifier Model: FCPS24-S6 Voltage: 24 VDC Initiating Circuits/Class Used: 1/B Indicating Circuits/Class Used: 2/B Static Battery Voltages/Size/Dates: /31,.67„C7-- .. Mfg Date x 5—Inst Date "'?•C•ie Battery Under Load Test: AC Circuit Breaker Location: C.,,,, ,-- _ Trouble Signal with AC Power Off: M Yes .No 1—N/A Circuits Operate on Standby Battery: k Yes _No [—N/A Circuits Checked for Supervision: _ Yes No N/A Circuits Trouble on Ground Fault: Yes No I—N/A Lamps/LED's: k Yes I—INo PN/A Panel Key on Site: Yes _No N/A Operating Instructions at Panel: Ill Yes No XN/A AUXILIARY PANEL CHECKS Panel Manufacturer: Model: Voltage: Initiating Circuits/Class Used: Indicating Circuits/Class Used: Static Battery Voltages/Size/Dates: Mfg Date Inst Date Battery Under Load Test: AC Circuit Breaker Location: _ Trouble Signal with AC Power Off: Yes _No EN/A Circuits Operate on Standby Battery: _Yes _No N/A Circuits Checked for Supervision: Yes riNo —IN/A Circuits Trouble on Ground Fault: I—Yes No 1—N/A Lamps/LED's: [Yes No EN/A Panel Key on Site: I—Yes —INo EN/A Operating Instructions at Panel: Yes No N/A INITIATING AND SUPERVISORY ZONE DEVICE LOCATIONS TESTED DEVICE TYPE 001 Above FACP Kitchen Storage v/ Smoke Detector 002 Kitchen Pull Station 003 Front Entry Pull Station 004 Back Door Pull Station 005 Kitchen Hood MODULE TEST ONLY Ansul INDICATING DEVICE LOCATIONS ,- DEVICE TYPE Womens Restroom Strobe Mens Restroom Strobe Exterior Horn/Strobe Horn/Strobe Horn/Strobe Horn/Strobe Horn/Strobe EQUIPMENT TYPE TOTAL UNITS UNITS TESTED PASS/FAIL 1--Iorn PassL Fail_ Chime PassT Fail Voice Speaker Pass Fail Strobe 2 Pass' Fail' f Horn/Strobe 5 S-' Pass;'- Fail1— Chime/Strobe Pass_ Fail Speaker Strobe Pass Fair Bell Passr- Fair Sprinkler Water Gong Pass-1 Fail! Sprinkler Supervision Switch PassL Fail Sprinkler Flow Switch Pass[_ Fail— Heat Detector Pass Fair Smoke Detector 1 / Pass Fail_ Duct Detector PassE Fair f Manual Pull Station 3 'a Pass Fail_ Generator Start Pass'_ Fail HVAC/Ventilation Control Pass Fair_ Annunciator 1 / Pass Fail_ Elevator Recall Passe Fail Fire Door Release PassE Fail Secure Door Release Pass_ Fail_ Fire Phone/Microphone Pass(— Fail Other-Ansul Module Test Only 1 1 Pass. c Fail Other Pass Fair Other PassE Fail P• blems F9und: ��, �/.'^, /-.„'jjam,:'crcA62:11. ��;-� 1� 4- L/,:F 44.--" tAel:// 43-fr c�.�' j 4-7 rt'�'� C`Z°i I F': ,a�l 1 :~.-�-� ,7�I.c;An. /. ! ;-+./ 4,t../. / , /, ✓ 6>� Corrections/Made: f` 2e ! - -' / / f � lee•s:/G.C.ee / /mac.-.fi Cam ./`� i• / ?< r � -, /-e- �!'s;,�c. -- . '^i ---- /�� -'.''-- , 17 / /- Date Corrected: /2-7P--- 2 ( By: E THIS CERTIFIES THAT THIS FIRE ALARM HAS BEEN PROPERLY INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT AND IS CONSISTENT WITH FIRE ALARM MAINTENANCE STANDARDS. DISCREPANCIES ARE NOTED AND HAVE BEEN REPORTED TO THE FACILITY OWNER/MANAGER FOR CORRECTIVE ACTION. PLEASE NOTE DISCLAIMER ON REVERSE I W i ) - r-�5/ ��c‘-sue- a2—,2 i SIGN TtiIIE: FACILY`TYOWNER/MANAGER SIGNATURE: INSPECTOR/TECHNICIAN DATE