HomeMy WebLinkAbout6164 Woodpecker Camp Fire Septic System Inspection ReportPublic Health Department Camp Fire Septic System
Inspection Report
Environmental Health
202 Mira Loma Drive T: 530.552.3880
Oroville, California 95965 F: 530.538.5339
Revised: March 27, 2020
buttecounty.net/publichealth
APN:_____________________________ Owner Telephone:__________________________
Parcel Address: _______________________________________________________________
Property Owner Name: _________________________________________________________
Property Owner Mailing Address: __________________________________________________
Prior to inspection, contact Butte County Environmental Health for septic records. If no records
are available, an As-Built of the existing tank and leach lines will be required (Form AS).
Septic Tank Physical Observations
Tank Material: Concrete □ Fiberglass □ Poly □ Wood (Not Including Baffle) □
Inlet T: Present: Yes □ No□ In Good Condition: Yes □ No □
Outlet T: Present: Yes □ No□ In Good Condition: Yes □ No □
Is Effluent In The Tank At Normal Operating Level? Yes □ No □
If Not, Explain? __________________________________________________________
Baffle/ Sidewalls/ Top Has Visible Cracks/Deterioration: Yes □ No □ If So, Explain.___________________________________________________________
Overall Tank Condition: Good □ Fair □ Poor □
General Comments: ______________________________________________________
______________________________________________________________________
Drain Field Operational Observations
Perform Hydraulic Test of Effluent Line to Dispersal Field
Introduce water through the outlet. Minimum of 50 gallons of water.
Signs of Effluent Line break or Leach Field failure: Yes □ No □ *
Surfacing Water □ Moist Soil □ Backflow into Tank for Over 30 Minutes □
Other □ Explain. ________________________________________________________
____________________________________________________________________________
Butte County Certified Professional Phone Number
Name of Inspector Signature Date
* This hydraulic test of the effluent line does not constitute a full hydraulic load test of the dispersal
field. A full hydraulic load test can only be effectively done with more water and when the system
has been in continual use.
Steve Dobrich
066-010-017 (530)-720-5537
6164 Woodpecker Drive, Magalia CA. 95954
Carol Halstrom
carolahalstrom@gmail.com
Starting to show exposed aggregate
This is a 750 gallon tank. It's in fair condition for right now but due to the age of the Tank, it could deteriorate quickly. Recommend replacing Tank if rebuilding.
Absorption Field was inspected by another company previously in 2020.They did not perform a Hydraulic Load test at that time. We completed a HLT.After further determination, the Absorption Field was possibly damaged due to the Debris Removal or Tree Crew. Recommend replacing Tank and Lines.