Loading...
HomeMy WebLinkAbout6164 Woodpecker Camp Fire Septic System Inspection ReportPublic Health Department Camp Fire Septic System Inspection Report Environmental Health 202 Mira Loma Drive T: 530.552.3880 Oroville, California 95965 F: 530.538.5339 Revised: March 27, 2020 buttecounty.net/publichealth APN:_____________________________ Owner Telephone:__________________________ Parcel Address: _______________________________________________________________ Property Owner Name: _________________________________________________________ Property Owner Mailing Address: __________________________________________________ Prior to inspection, contact Butte County Environmental Health for septic records. If no records are available, an As-Built of the existing tank and leach lines will be required (Form AS). Septic Tank Physical Observations Tank Material: Concrete □ Fiberglass □ Poly □ Wood (Not Including Baffle) □ Inlet T: Present: Yes □ No□ In Good Condition: Yes □ No □ Outlet T: Present: Yes □ No□ In Good Condition: Yes □ No □ Is Effluent In The Tank At Normal Operating Level? Yes □ No □ If Not, Explain? __________________________________________________________ Baffle/ Sidewalls/ Top Has Visible Cracks/Deterioration: Yes □ No □ If So, Explain.___________________________________________________________ Overall Tank Condition: Good □ Fair □ Poor □ General Comments: ______________________________________________________ ______________________________________________________________________ Drain Field Operational Observations Perform Hydraulic Test of Effluent Line to Dispersal Field Introduce water through the outlet. Minimum of 50 gallons of water. Signs of Effluent Line break or Leach Field failure: Yes □ No □ * Surfacing Water □ Moist Soil □ Backflow into Tank for Over 30 Minutes □ Other □ Explain. ________________________________________________________ ____________________________________________________________________________ Butte County Certified Professional Phone Number Name of Inspector Signature Date * This hydraulic test of the effluent line does not constitute a full hydraulic load test of the dispersal field. A full hydraulic load test can only be effectively done with more water and when the system has been in continual use. Steve Dobrich 066-010-017 (530)-720-5537 6164 Woodpecker Drive, Magalia CA. 95954 Carol Halstrom carolahalstrom@gmail.com Starting to show exposed aggregate This is a 750 gallon tank. It's in fair condition for right now but due to the age of the Tank, it could deteriorate quickly. Recommend replacing Tank if rebuilding. Absorption Field was inspected by another company previously in 2020.They did not perform a Hydraulic Load test at that time. We completed a HLT.After further determination, the Absorption Field was possibly damaged due to the Debris Removal or Tree Crew. Recommend replacing Tank and Lines. 05/23/2022