Loading...
HomeMy WebLinkAboutFAI20-0027 010141011 CF FA 2021 Fire Alarm and Life Safety System Inspection Certificate For Esperanza High School 581 Jackson Street Gridley, CA GRIDLEY Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Jul 19, 2021 Building: Esperanza High School Company: Hue&Cry,Inc. Contact: Jordan Reeves Contact:johnathan jones Title: Superintendent Title: inspector Executive Summary Generated by:BuildingReports.com Building Information Building: Esperanza High School Contact: Jordan Reeves Address: 581 Jackson Street Phone: 1-530-846-4721 Address: Fax: CitylStatelZip: Gridley, CA GRIDLEY Mobile: Country: United States of America Email:jreeves@gusd.org Inspection Performed By Company: Hue&Cry, Inc. Inspector:johnathan jones Address: 1751 Bruce Drive Phone: 916-956-0859 Address: Fax: City/State/Zip:Anderson, California 96007 Mobile: Country: United States of America Email: J.jones@hueandcry.com System Control Unit Manufacturer: Fire-Lite Inspection Date: 07/19/2021 IDC Style: B Model Number: MS-5024UD Install Date: 01/30/2005 SLC Style: Software Version: 43 Version Date: 02/04/2007 NAC Style: Y Location: Water Heater/Staff Room Current Protection: Breaker Disconnect Location:Water Heater/Staff Room Type: Breaker If oni, cring x Company: Hue&Cry, Inc. Phone: 800-800-ALARM Account#: 230018 Hue&Cry,Inc. Page 1 of 13 Download Date:05/25/2022 Executive Summary Inspection Summary f Total Items Serviced T Passed Failed/Other Category: i Qty % Qty I °/n Qty % Qty % Control 6 13.95% 6 100.00% 6 100.00% 0 0.00% Indicating 17 39.53% 17 100.00% 16 94.12% 1 5.88% Initiating 19 44.19% 19 100.00% 19 100.00% 0 0.00% Supervisory 1 2.33% 1 100.00% 1 100.00% 0 0.00% Totals I 43 1 100% 43 1100.00% I 42 97.67% 1 2.33% Certification l Company: Hue&Cry, Inc. Building: Esperanza High School Inspector:johnathan jones Contact: Jordan Reeves I Signed:Jul 20, 2021 Signed: Jul 19, 2021 Hue&Cry,Inc. Page 2 of 13 Download Date:05/25/2022 Executive Summary Discrepancy Report Generated by:BuildingReports.com A High Esperanza Hi h School Control Panel: 1 - Fire-Lite MS-5O24UD � The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience.Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. Device Type Manufacturer ModelNumber Date Qty Items listed for Recall or Replacement/Upgrade No items found during this inspection. ScanlD Location .Problem Address Reference Indicating Bell 1 13975309 Market Failed Operation 1 NFPA72 14.2.2.2.2 Code References NFPA72 14.2.2.2.2 System deficiencies shall be corrected. Hue&Cry,Inc. Page 3 of 13 Download Date:05/25/2022 Discrepancy Report Proposed Solutions Report Generated by;BuildingReports.com Building: Esperanza High School Control Panel: I - Fire-Lite MS-5024UD The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report.items listed as T/M are available for repair on a Time and Materials basis. Scanib Location Solution Model# Cost Fix Indicating Bell 13975309 Market Investigate SSV120-8 T/M ❑ PO#: (none) T/M Hue&Cry,Inc. Page 4 of 13 Download Date:05/25/2022 Proposed Solutions Report Notes & Recommendations Generated by:BuildingReports.com Building: Esperanza High School x`,:x.c" , k . The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection.Notes are grouped by Category. General Note Annual fire inspection 6/19/2021 Water flow bell failed to operate when water flow went into alarm needs to be investigated. Hue&Cry,Inc. Page 5 of 13 Download Date:05/25/2022 Notes&Recommendations Inspection & Testing Generated by:BuildingReports.corn Building: Esperanza High School Control Panel: i - Fire-Lite.MS-5024UD The Inspection & Testing section lists all of the items inspected in your building.Items are grouped by Passed or Failed/Other.Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. °I ' 0c4F"]" Locatt0i I Service 'Ti I , tr[ e -. Passed Control Battery FACP/Left Batt Annual 3:09:34 PM 07/19/2021 Battery FACP/Right Batt Annual 3:10:35 PM 07/19/2021 Control Panel Water Heater/Staff Room Annual 3:10:49 PM 07/19/2021 Disconnect S/E Whse Storage Area Annual 4:49:26 PM 07/19/2021 Phone Jack 530-846-2435 SEC Annual 3:09:22 PM 07/19/2021 Phone Jack 530-846-6721 PRI Annual 3:09:25 PM 07/19/2021 Indicating Horn/Strobe Conference Room Annual 3:33:52 PM 07/19/2021 Horn/Strobe East Center Class Annual 3:01:00 PM 07/19/2021 Horn/Strobe East Outside Annual 3:33:55 PM 07/19/2021 Horn/Strobe Lower LobbyCubicle Annual 3:33:58 PM 07/19/2021 i Horn/Strobe N/W Classroom Annual 2:52:44 PM 07/19/2021 Horn/Strobe Office Annual 2:45:42 PM 07/19/2021 Horn/Strobe Principals Office Annual 2:58:36 PM 07/19/2021 Horn/Strobe S/E Classroom Annual 3:06:28 PM 07/19/2021 HornlStrobe West Ctr Classroom Annual 2:51:33 PM 07/19/2021 Strobe East Ctr Class Women's R/R Annual 3:02:53 PM 07/19/2021 Strobe S/E Class Men's R/R Annual 3:06:59 PM 07/19/2021 Strobe S/E Class Women's RJR Annual 3:07:09 PM 07/19/2021 Strobe S/W Class Men's R/R Annual 3:34:11 PM 07/19/2021 Strobe S/W Class Women's R/R Annual 3:07:43 PM 07/19/2021 Strobe Water Heater FACP R/R Annual 3:34:09 PM 07/19/2021 Strobe East center classroom mens restroom Annual 3:02:42 PM 07/19/2021 Initiating Heat Detector Water Heater Room I FACP Annual 3:30:47 PM 07/19/2021 Pull Station N/W Exit Annual 2:51:59 PM 07/19/2021 Pull Station S/E Exit Annual 3:04:31 PM 07/19/2021 Pull Station S/W Exit Annual 2:50:19 PM 07/19/2021 Pull Station Front Entry Annual 2:59:04 PM 07/19/2021 Hue&Cry,Inc. Page 6 of 13 Download Date:05/25/2022 Inspection&Testing ....... ....... Device Type; ' , Location Service Time I Date Passed Smoke Detector Conference Room Annual 3:04:01 PM 07/19/2021 Smoke Detector East Ctr Class Annual 3:00:15 PM 07/19/2021 Smoke Detector East Ctr Class R/R Hall Annual 3:02:15 PM 07/19/2021 Smoke Detector N/E Office Annual 3:34:03 PM 07/19/2021 Smoke Detector NM Class Annual 2:53:11 PM 07/19/2021 Smoke Detector N/W Class Storage Annual 2:54:38 PM 07/19/2021 Smoke Detector Principals Office Annual 2:57:50 PM 07/19/2021 Smoke Detector SIE Class Annual 3:05:40 PM 07/19/2021 Smoke Detector SIE Class R/R Hall Annual 3:06:34 PM 07/19/2021 Smoke Detector S/W Class Annual 2:48:56 PM 07/19/2021 Smoke Detector S/W Class R/R Hall Annual 3:07:54 PM 07/19/2021 Smoke Detector Server Hall Annual 3:07:16 PM 07/19/2021 Smoke Detector West Ctr Class Annual 2:51:21 PM 07/19/2021 Waterflow Switch Market Riser Room in Front Annual 3:17:04 PM 07/19/2021 Supervisory Tamper Switch Market Riser Room in Front Annual 3:16:54 PM 07/19/2021 Device T e. , ! Location YP, ; I Service Time `I Date Failed/Other Indicating 1 Bell Market Annual 3:28:48 PM 07/19/2021 Hue&Cry,Inc. Page 7 of 13 Download Date:05/25/2022 Inspection&Testing Service Summary Generated by:BnildingReports.corn Building: Esperanza High School { The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity. Failed/Other Bell Annual 1 Total ,l Pas Battery Annual 2 Control Panel Annual 1 Disconnect Annual 1 Heat Detector Annual 1 Horn/Strobe Annual 9 Phone Jack Annual 2 Pull Station Annual 4 Smoke Detector Annual 13 Strobe Annual 7 Tamper Switch Annual 1 Waterflow Switch Annual 1 Total 42 Grand Total 43 Hue&Cry,Inc. Page 8 of 13 Download Date: 05/25/2022 Service Summary Auxiliary Functions Testing Generated by:BuildingReports.com Building: Esperanza High School Control Panel: I - Fire-Lite MS-5024UD The Auxiliary Functions Testing section lists each of the ancillary items, systems, and emergency equipment that are controlled by the system control unit. Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. 'Type Location Comment ScanID Simulated Passed Heat Detector Heat Compartment Water Heater Room/FACP Passed 11531319 Smoke Detector Smoke Compartment Conference Room Passed 11531304 Smoke Compartment East Ctr Class Passed 11531310 Smoke Compartment East Ctr Class R/R Hall Passed 11531308 Smoke Compartment N/E Office Passed 11531301 Smoke Compartment NIW Class Passed 11531324 Smoke Compartment NIW Class Storage Passed 11531297 Smoke Compartment Principals Office Passed 11531303 Smoke Compartment SIE Class Passed 11531313 Smoke Compartment SIE Class R/R Half Passed 11531316 Smoke Compartment SIW Class Passed 11531333 Smoke Compartment S/W Class R/R Hall Passed 11531331 Smoke Compartment Server Hall Passed 11531317 Smoke Compartment West Ctr Class Passed 11531328 Hue&Cry,Inc. Page 9 of 13 Download Date:05/25/2022 Auxiliary Functions Testing Time, Temperature & Level Testing Generated by:BuildingReports.com Building: Esperanza High School Control Panel: 1 - Fire-Lite MS-5024UD The Time, Temperature, &Level Testing section details the measurements taken from various devices that are designed to respond in a certain amount of time, respond at a certain temperature, or respond within the acceptable range of volume or level.Items are grouped by Passed or Failed/Other. I Type Location Comment Sec Deg LEI ScanlD Passed Waterflow Switch Market Riser Room in Front Passed 9 n/a n/a 11531293 Hue&Cry,Inc_ Page 10 of 13 Download Date:05/25/2022 Time,Temperature Sc Level Testing Battery & Power Supply Testing Generated by:BuildingReports.corn Building Esperanza High School Control Panel: 1 -Fire-Lite MS-5024UD The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Rated Rated Post _,Type Location j Ah Volts Pre Test Test Min Ah Tested Ah Battery II I Passed Sealed Lead Acid FACP/Left Bail 7 12 12.72 4.55 8 Sealed Lead Acid FACP/Right Batt 7 12 12.65 4.55 11 Hue&Cry,Inc. Page 11 of 13 Download Date: 05/25/2022 Battery&Power Supply Testing Inventory & Warranty Report Generated by:BuildingReports.com Building: Esperanza High School Control Panel: 1 - Fire-Lite MS-5024UD The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. ti Category j olo of Invento �- ry Qgan>rtjr:- Battery Control 4.65% � 2 Bell Indicating 2,33% 1 Control Panel Control 2.33% 1 Disconnect Control o 2.33/o 1 Heat Detector Initiating 2.33% 1 Horn/Strobe Indicating 20.93% 9 Phone Jack Control o 4.65/0 2 Pull Station Initiating 9.30% 4 Smoke Detector Initiating 30.23% 13 Strobe Indicating 16.28% 7 Tamper Switch Supervisory 2.33% 1 Waterfrow Switch Initiating 2.33% 1 Type ,. Qty Model# Description Install Date In Service - 3 Years to 5 Years Power-Sonic Battery 2 PS-1270 F1 Sealed Lead Acid 11/19/2018 I In Service - 15 Years to 25 Years Phone Jack 1 RJ-31 X l 01/30/2005 Phone Jack 1 RJ-31X 01/30/2005 Fire-Lite Control Panel 1 MS-5024UD 01/30/2005 Pull Station 4 BG-12 Dual Action 01/30/2005 GE Disconnect 1 20amp Breaker 01/30/2005 System Sensor Bell 1 SSV120-8 01/30/2005 Heat Detector 1 5601P Combination 01/30/2005 Horn/Strobe 8 P2R 01/30/2005 Horn/Strobe 1 P2RK 01/30/2005 Smoke Detector 13 2W-B Photoelectric 01/30/2005 Strobe 7 SR 01/30/2005 Tamper Switch 1 OSY2 01/30/2005 Waterflow Switch 1 WFD60 01/30/2005 Hue&Cry,Inc. Page 12 of 13 Download Date:05/25/2022 Inventory&Warranty Report Zone Address Report Generated by:BuildingReports.com Building: Esperanza High School y Control Panel: 1 -'Fire-Lite MS-5O24UD The Zone Address Report lists all of the devices and items that have an individual address, or are grouped together under a common zone. The device type, location, and description are included for your reference. Address Device T e —. — —. _n -- yp loocation ` Type ScanlD v Zone/Circuit: 1 Pull Station NIW Exit Dual Action 11531325 Pull Station S/E Exit Dual Action 11531312 Pull Station S/W Exit Dual Action 11531334 Pull Station Front Entry Dual Action 11531299 Zone/Circuit: 2 Smoke Detector NIW Class Photoelectric 11531324 Smoke Detector N/W Class Storage Photoelectric 11531297 Smoke Detector SM/Class Photoelectric 11531333 Heat Detector Water Heater Room/FACP Combination 11531319 Smoke Detector West Ctr Class Photoelectric 11531328 Zone/Circuit: 3 Smoke Detector Conference Room Photoelectric 11531304 Smoke Detector East Ctr Class Photoelectric 11531310 Smoke Detector East Ctr Class R/R Hall Photoelectric 11531308 Smoke Detector NIE Office Photoelectric 11531301 Smoke Detector Principals Office Photoelectric 11531303 Smoke Detector S/E Class Photoelectric 11531313 Smoke Detector S/E Class R/R Hall Photoelectric 11531316 Smoke Detector SIW Class R/R Hall Photoelectric 11531331 Smoke Detector Server Hall Photoelectric 11531317 ZonelCircuit: 4 Waterflow Switch Market Riser Room in Front 11531293 Zone/Circuit: 5 Tamper Switch Market Riser Room in Front 11531294 Hue&Cry,Inc. Page 13 of 13 Download Date:05/25/2022 Zone Address Report