Loading...
HomeMy WebLinkAbout058-420-029 EHDR19-01090 Septic Report Camp FirePublic Health Department Camp Fire Septic System Inspection Report revised 032720 Environmental Health 202 Mira Loma Drive T: 530.552.3880 Oroville, California 95965 F: 530.538.5339 buttecounty.net/publichealth APN:_____________________________ Owner Telephone:__________________________ Parcel Address: _______________________________________________________________ Property Owner Name: _________________________________________________________ PropertyOwner Mailing Address: __________________________________________________ Prior to inspection, contact Butte County Environmental Health for septic records. If no records are available, an As-Built of the existing tank and leach lines will be required (Form AS). Septic Tank Physical Observations Tank Material: Concrete X Fiberglass □ Poly □ Wood (Not Including Baffle) □ Inlet T: Present: Yes X No□ In Good Condition: Yes □ No □ Outlet T: Present: Yes X No□ In Good Condition: Yes □ No □ Is Effluent In The Tank At Normal Operating Level? Yes X No □ IfNot, Explain? __________________________________________________________ Baffle/ Sidewalls/ Top Has Visible Cracks/Deterioration: Yes X No □ If So, Explain.___________________________________________________________ Overall Tank Condition: Good □ Fair □ Poor X General Comments: ______________________________________________________ Drain Field Operational Observations Perform Hydraulic Test of Effluent Line to Dispersal Field Introduce water through the outlet. Minimum of 50 gallons of water. Signs of Effluent Line break or Leach Field failure: Yes □ No X * Surfacing Water □ Moist Soil □ Backflow into Tank for Over 30 Minutes □ Other □ Explain. ____________________________________________________________________________ Butte County Certified Professional Phone Number: 530-877-3207 Name of Inspector Signature Date This hydraulic test of the effluent line does not constitute a full hydraulic load test of the dispersal field. A full hydraulic load test can only be effectively done with more water and when the system has been in continual use. 058-042-029 530-332-0143 3867 Coniston Loop, Oroville, CA 95965 Requested by Buyer, Jennifer Becker jbecker@cboe.org Top of tank is crushed in, crack extends from inlet lid to outlet side. Tank is very unsafe the way it is, needs further precautions to make safe. Will completely collapse in at some point. Absorption field tested Good. Mark Muhlbaier June 7, 2022