HomeMy WebLinkAboutFAI15-0062 Fire Alarm 2020 (2) Coy: Page I of -/ jstof-j/Site/CES Overall System: Door Code: 1900 Pass n Fail c aM See Note #: Fire Alarm Inspection Record i (,,F, ,F,,,,,,,.,,,,,a A,,,,:,,,,,,,, 632 Entler Ave. Lic#C10-1057872 Chico,Ca.95928 ACO 7938 530.636.4257 Central Station Account Number: 517-1003(Side B)&517-1010(Side A) Dispatch Agent:`'VLs S `A,C b, Approved Central Dispatch Agency: National Monitoring Center(NMC) Testing Date: `t- a f.) - /L `c.' Phone Number: 1.855.343.4458 Time On Test:, `. 3 ci Time Off Test:', : LS Customer Information: Testing Frequency: System Information: Premise: Roseleaf-Oroville(Roseleaf,Inc.) U Quarterly Control Unit Manufacturer: Honeywell/Ademco Address: 1900 20th St. FACP Model: Vista 128FB/Vista 100 Ver#: City: Oroville Zip: 95965 ja Semi-Annual Number of Circuits: Circuit Style: Owner/Contact: David K./Carrie Brown IDC: 8 A / B Phone Number: 530.514.4394/530.538.8200 0 Annual SLC: N/A A / B Fire Departmen Cal Fire/Oroville FD Communication Type: Pri: 0 Local III POTS ❑ Radio 0 IP 0 Cellular Specify Provider: ❑ Verizon 0 AT&T Sec: 0 Local •POTS 0 Radio 0 IP 0 Cellular Specify Provider: 0 Verizon 0 AT&T Pri.Number: 530.538. (Vista 100) 0 Verify 0 Test Comment: Sec.Number: 530.538.8270(Vista 128FB) 0 Verify ❑Test Comment: Antenna Loc: 0 Verify 0 Test Comment: System Power Supplies: Battery Type: *System Main Power Nominal Voltage: 120 VAC Amps: 20 I Sealed Lead-Acid Overcurrent Protection: Type: Breaker Amps: 20 0 Other List: Primary FACP location: Electrical Room&Service Hallway Manufacturers Date: 11/28/2014-7/8/2016 Disconnecting means location: Electrical Room(Breaker) Installation Date: 7/27/2015-11/14/2016 *Secondary Power(Standby) 0 Visual 0 Functional Battery Storage: 12VDC Amp-Hr Rating: Pre Load Post Load Pass/Fail Calculated capacity in Amp-Hrs to operate system for 24 hours Battery 1 Voltage: See Below See Below 0 P F 0 0 Verify ❑Test Comment: Battery 2 Voltage: See Below See Below 0 P F❑ Remote Power Supplies: Cell Battery Voltage: 0 P F 0 Type: Location: Purpose: Other Batteries(Rating): Pre Load Post Load 7Ah Vista 128#1 la \D I 1 k P F 0 7Ah Vista 128#2 I LLQ 7o 9 P F❑ 7Ah Vista 100#1 1 I to 1 1 X. P F El 7Ah Vista 100#2 I ?. (t; Z C. i..i l P F 0 ❑ P F❑ ❑ P F❑ ❑ P F❑ ❑ P F❑ No fication Appliance Tests and Inspections Qty: Devices: Wiring: Visual Test: Functional Test: Synced Oper: Pass: Fail: No.of Alarm 1 Bells 120 VAC IN 03 0 MI 0 Notification Circuits: Bells 24 VDC 0 ❑ 0 0 0 Horns A / B 0 0 0 0 0 4 10 Strobes A/ B 0 ❑ ❑ 0 0 12 Horn/Strobes A / B 0 0 ❑ 0 0 Are they monitored Chimes A / B 0 0 0 0 0 for integrity?: Speakers A / B 0 0 0 0 Y / N 12 Door Holder A / B ® 5 ❑ R 0 Initiating&Supervisory Device Tests and Inspections ••More Devices on Additional Pages" Add/Zn: Device Location: Device Type: Measured Setting(%Obs/ft): Visual: Function: Pass: Fail: I 0 0 0 0 I 0 0 ❑ 0 0 ❑ 0 0 I. 0 0 0 0 I ❑ 0 0 0 Copy: Pages of 1 Cdstorner/Site/CES Initiating&Supervisory Device Tests and Inspections ••More Devices on Additional Pages" Add/Zn: Device Location: Device Type: Measured Setting(%Obs/Jt): Visual: Function: Pass: Fail: Vino 128FB_Zone Coverage lA:cpunt 4517-100J ❑ El El ❑ 1 (West Area 1 Manual Pull El El El El 2 (Middle Area I Manual Pull El ❑ El ❑ 3 East Area Manual Pull ❑ El El El 4 ❑ ❑ ❑ El 5 0 0 El El 6 0 0 El El 7 Common Foe Zone Panel Tugger/NAC El ❑ ❑ El 8 ❑ ❑ El El 9 El El El El 10 Room#19 Photo El El ❑ El 11 Laundry Room Photo El El El El 12 Medication Room Photo El El 0 El 13 Room#21 Photo El El El 0 14 Room#23 Photo El El El El 15 Room#25 Photo ❑ El El El 16 Room#27 Photo El El El El 17 Room#29 Photo El El ❑ El 18 Room 031 Photo ❑ El El ❑ 19 Room#30 Photo El El El ❑ 20 Room#28 Photo El ❑ El ❑ 21 Room#26 Photo El ❑ El El 22 Room#24 Photo ❑ El El El 23 Room#22 Photo El El El El 24 Room#20 Photo El El El El 25 East Rear Hallway Photo El El El El 26 East Hallway-Center Photo El El El El 27 East Hallway-Front Area Photo El El El El 28 West Rear Area Photo El Cl El El 29 West Middle Area Photo El ❑ El El 30 Reception Area Photo El El El El 31 West Front Area Photo El El El El 32 Lounge-West Area Photo El El El El 33 Lounge-East Area Photo ❑ El El El 34 Break Room Photo El ❑ El El 35 Water Heater Area Carbon Monoxide El El El El 36 Laundry Area Carbon Monoxide El El El El 37 Kitchen Area Carbon Monoxide El ❑ El El El El El ❑ El El El El ❑ El El El Vsta 100-Zone Coverage(Account#517-111301 El '0 El El 1 Fire Riser Water-flow V1 I '-tt ®. ,E tEl El 2 El El El El 3 ❑ 0 El El 4 El El El El 5 El El El El 6 El El El ❑ 7 Common Fire Zone Panel Trigger/NAC El ❑ El El 8 El El El El 9 El El El El 10 Soda Shop Photo El El El El 11 Room#2 Photo El ❑ El El 12 Nelson Wing Storage Heat El El El El 13 Nelson Wing Water Heater Closet Heat El El ❑ El 14 Room#4 Photo ❑ El ❑ O 15 Nelson Wing Hallway Photo El ❑ El El 16 Room#6 Photo El ❑ El El 17 Room#1 Photo El El El El 18 Room#3 Photo El 0 El El 19 Room#5 Photo ❑ El El El 20 Room#7A Photo El El El El 21 Room#7B Photo El El El El 22 Room#BB Photo El ❑ El El 23 Room BOA Photo ❑ El El El 24 Activity Room Photo El El ❑ El 25 Activity Office Photo El 0 El El 26 Beauty Shop Photo 0 0 0 El