Loading...
HomeMy WebLinkAboutCSA-0014 047-460-033 CF Pump 7.2022 Zt)urham Pump&Irrigation WM.P.WILSON&SONS Invoice wwAurhampump<om CL#271327 Main Office: Woodland Branch: Number: 0207479-IN Durham Pump,Inc. Wm.P.Wilson&Sons . 7/26/2022 4 2313 Durham-Dayton Hwy,Durham,CA 95938 202 Kentucky Ave,Woodland,CA 95695 530.891.4821 530-891.0613 Fax 530.662.8654 530.662.5797 Fax Page: 1 Order/Date: 0059574 7/20/2022 I Please Remit All Payments to: Durham Pump,PO Box 80,Durham,CA 95938 Thank you! f Customer#: 01-0005315 Salesperson: JOHN RHEIN Sold To: BUTTE COUNTY FIRE DEPT-MAIN Ship To: CSA#180-HAWK RANCH 7 COUNTY CENTER DR HAWK CT. ATTN:MARGE CHICO,CA 95973 OROVILLE,CA 95965 Confirm To: JOHN GADDIE Job Name: CM#180 Hawk Ranch Customer P.O. Ship VIA: F.O.B. Terms: NET 10TH Item Code Description Unit WH Qty Ordered I Shipped / B.O. Price Amount 07/7/2022 COMPLETE BI-ANNUAL SERVICE AND MAINTENANCE CHECKS.REPORTS ENCLOSED. /PMAINT PUMP SERVICE CONTRACT LABOR 0.00 200.00 c5143—c.el Lj a`17-KCo-033 SPECIAL ORDER ITEMS: Special Orders(items not normally stocked)are non-returnable unless they can ' Taxable Amount: 0.00 be resold to others or are accepted for return by our vendor.There will be a minimum restock fee of Non-Taxable Amount: 200.00 15%of the item value,or amount charged by vendor,whichever is higher,plus any applicable freight incurred.All special sale/close-out item sales are final,no returns. Thank you. Net Invoice: 200.00 Less Discount: 0.00 Sales Tax: 0.00 Signature N/q Invoice Total: 200.00 Less Deposit: 0.00 • Invoice Balance: 200.00 Durhamc' '. Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891 .4821 CSA #180 - Hawk Ranch CUSTOMER NAME: Butte County Fire Dept. DATE: 7/7/2022 Motor Mfg: Franklin HP: 20 Meter #: 22P816 RPM 3450 Volts 460 Phase 3 Rated Amps: TM 80 Yes No Serial # PG &E Acct. # Other: Panel Mfg: C/H NEMA Size: 3 Type: X/L P/W Other: Pump Mfg: ? Sub Serial#: Non-Running Checks: Pump Model Manufacturer na Lubricant Levels - Service and Change if Necessary Discharge 8" Fab na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary 1 Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses - Replace if Necessary Replaced Size: Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: O's to ground Excessive or Unusual Noise Ok/see comments Pressure tank: okay Excessive or Unusual Vibration Ok/see comments Tank condition: Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Amperage: Expected: Pressure setting: Actual: L 9: 64.8 L2: 67.7 L3: 64.6 Average: 65.7 Overload Underload Even Load Bowl Adjustment: N/A Yes No Comments: Site has been cleared of brush G PS: The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS & INSPECTIONS\Cal Fire CSA's\180 Hawk Ranch\180 Reports PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#180 - Hawk Ranch CUSTOMER NAME: Butte County Fire Dept. DATE: 7/7/2022 Motor Mfg: HP: 1/2 Meter#: RPM Volts 240 Phase Rated Amps: TM 80 Yes No Serial# PG &E Acct. # Other: Panel Mfg: 2 WIRE SUB NEMA Size: Type: X/L P/W Other: Pump Mfg: Serial#: Non-Running Checks: Pump Model Manufacturer na Lubricant Levels- Service and Change if Necessary Discharge na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: nW/I Acceptable Limits Unacceptable Fuses- Replace if Necessary Replaced Size: Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: O's to ground Excessive or Unusual Noise ' Ok/see comments Pressure tank: Excessive or Unusual Vibration ,, Ok/see comments Tank condition: Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Amperage: Expected: 8.2 Pressure setting: 40-60 psi Actual: L1: 8.3 7 8.4 L3: 0 Average: 8.35 Overload Underload Even Load Bowl Adjustment: N/A Yes No Comments: Site has been cleared of brush GPS: The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\180 Hawk Ranch\180 Reports