Loading...
HomeMy WebLinkAboutCSA19-0002 047-780-034 CF Pump 7.2022 Durham Pump&Irrigation WM.P.WILSON&SONS Invoice CL#271327 Number: 0207481-IN Main Office: Woodland Branch: Durham Pump,Inc. Wm.P.Wilson&Sons Date: 7/26/2022 2313 Durham-Dayton Hwy,Durham,CA 95938 202 Kentucky Ave,Woodland,CA 95695 530.891.4821 530-891.0613 Fax 530.662.8654 530.662.5797 Fax Page: 1 Order/Date: 0059576 7/20/2022 Please Remit All Payments to: Durham Pump,PO Box 60,Durham,CA 95938 Thank you! ICustomer#: 01-0005315 Salesperson: JOHN RHEIN Sold To: BUTTE COUNTY FIRE DEPT-MAIN Ship To: CSA#183-RARE EARTH SUED. 7 COUNTY CENTER DR. TIBERON WAY ATTN:MARGE CHICO,CA 95973 OROVILLE,CA 95965 Confirm To: JOHN GADDIE Job Name: CSA#183 Rare Earth Subd Customer P.O. Ship VIA: F.O.B. Terms: NET 10TH • Item Code Description Unit WH Qty Ordered / Shipped / B.O. Price Amount 7/6/2022 COMPLETE BIANNUAL SERVICE AND MAINTENANCE CHECKS.REPORTS ENCLOSED. /PMAINT PUMP SERVICE CONTRACT LABOR 0.00 200.00 c56 i i-OooZ- a111-780-039 SPECIAL ORDER ITEMS: Special Orders(items not normally stocked)are non-returnable unless they can Taxable Amount: 0.00 be resold to others or are accepted for return by our vendor.There will be a minimum restock fee of Non-Taxable Amount: 200.00 15%of the item value,or amount charged by vendor,whichever is higher,plus any applicable freight incurred.All special sale/close-out item sales are final,no returns.Thank you. Net Invoice: 200.00 Less Discount: 0.00 Sales Tax: 0.00 Signature N/f Invoice Total: 200.00 Less Deposit: 0.00 Invoice Balance: 200.00 Dutha ci. Plump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#183 - Rare Earth Subdivision CUSTOMER NAME: Butte County Fire Dept. DATE: 7/6/2022 Motor Mfg: Franklin HP: 1.5 Meter#: RPM 3450 Volts 240 Phase 1 Rated Amps: 11.5 MAX TM 80nYes No Serial# PG &E Acct. # Other: Panel Mfg: NEMA Size: Type:nX/L n P/w Other: Pump Mfg: ?Sub Serial#: Non-Running Checks: Pump Model Manufacturer na In Lubricant Levels - Service and Change if Necessary Discharge CAST 11/4 na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: nW/I Acceptable Limits n Unacceptable Fuses- Replace if Necessary nReplaced Size: 20 AMP BREAKER Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: Q's to ground Excessive or Unusual Noise Ok/see comments Pressure tank: PC-266 TANK Excessive or Unusual Vibration Ok/see comments Tank condition: Control Devices: H.O.A. Start Switch Time Clock nFrost Start Time Delay Other: PRESS. SWITCH Amperage: Expected: 11.5 Pressure setting: 40-60 Actual: Y 10.3 B 12.8 R 1.7 Average: 8.267 Overload Underload Even Load Bowl Adiustment: N/A nYes No Comments: Gate broken GPS: The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions,nor warranty any part of the existing system. S:1Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's1183 Rare Earth Subd1183 Reports Durha i ' '. Pump PUMP CHECK REPORT 2313 Durham-Dayton Hwy. Durham, CA 95938 530.891 .4821 CSA#183 - Rare Earth Subdivision CUSTOMER NAME: Butte County Fire Dept. DATE: 7/6/2022 • Motor Mfg: Franklin HP: 60 Meter #: 1005378640 RPM ? Volts 480 Phase 3 Rated Amps: ? TM 80 Yes No Serial # PG &E Acct. # Other: Panel Mfg: SIEMANS NEMA Size: 3.5 Type: X X/L P/W Other: Pump Mfg: ? Sub Serial#: Non-Running Checks: Pump Model Manufacturer na Lubricant Levels - Service and Change if Necessary Discharge 6" Fab na Oiler Unit and/or Packing Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: W/I Acceptable Limits Unacceptable Fuses - Replace if Necessary Replaced Size: FLSR 200 ID Perform General Clean-Up of Electrical Panel and Motor Running Checks: Motor winding resistance: ('s to ground Excessive or Unusual Noise Ok/see comments Pressure tank: Excessive or Unusual Vibration Ok/see comments Tank condition: Control Devices: H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Amperage: Expected: 80.5 Pressure setting: Press Sw 50-70 Actual: L 1 64.2 L2 64.8 L3 66.1 Average: 65.03 Overload Underload Even Load Bowl Adjustment: N/A Yes No Comments: Slightly high incoming voltage. 491V, 492V, 490V GPS: The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS & INSPECTIONS\Cal Fire CSA's\183 Rare Earth Subd\183 Reports