HomeMy WebLinkAboutFAI15-0097 079-230-017 CF FA 2015 aimplexerinnell BE SAFE ANNUAL FIRE ALARM TEST & INSPECTION FEATHER FALLS CASINO 3 ALVERDA DR OROVILLE, CA. 95966 11/25/2015 SimplexGrinnell 4650 Beloit Drive Sacramento, CA 95838 916-283-0300 • ISIMPleXGrinnell BE SAFE 4650 Beloit Drive, Sacramento CA 95838— (916) 283-0300 — (916) 920-2241 ALARM & DETECTION EQUIPMENT TEST REPORT Technician #1 CHRIS JAMES Technician #2 0 Cell Phone# 530-207-7582 Cell Phone# 0 November 25, 2015 Customer Name: Property address: (if different) FEATHER FALLS CASINO 3 ALVERDA DR 3 ALVERDA DR OROVILLE, CA. 95966 OROVILLE, CA. 95966 SR# 33263094 Contact Information: Monitoring Information: Name: TROY Central Station: CERTIFIED SYSTEf Phone: 530-533-3885 Acct#: 8099046 Fax: - Phone: 800-473-5244 Time of Test Operator#& Name: Control Panel Status Before Test: Panel Type: FIRELITE Model: MS-9200 Yes No Notes: Is Power Light On? X Does the Panel Indicate Normal Condition? X Is the panel in a Trouble Condition? Are all Indicating Lamp Bulbs in Operating Order? X Does the Silence Switch Operate? X Do the Batteries indicate they are Properly Charged? X Type Pass Fail Amp/VIt Date Battery#1 SEALED X 7AH 12V Jan-11 Battery#2 SEALED X 7AH 12V Jan-11 Comments: Page 2 of 6 • SimplexGrinnell BE SAFE. 4650 Beloit Drive,Sacramento CA 95838— (916)283-0300 —(916)920-2241 25-Nov-15 FEATHER FALLS CASINO 3 ALVERDA DR OROVILLE, CA. 95966 Device Floor Zone Alarm Trouble Location Note: MAIN CASINO TAMPER 2 M-24 Pass NA 2ND FLR TAMPER SMOKE DETECT. 2 D-07 Pass NA SURVEILLANCE ROOM WATER FLOW 2 M-19 Pass NA DRY RISER LOW PRESSURE 2 M-20 Pass NA AIR REGULATOR SMOKE DETECT. 2 D-08 Pass NA ELEV. LOBBY 2ND. FLR SMOKE DETECT. 2 D-09 Pass NA ELEV. SERV.2ND FLR PULL STATION 1 M-01 Pass NA MAIN LOBBY ENTRY PULL STATION 1 M-02 Pass NA MAIN LOBBY ENTRY PULL STATION 1 M-03 Pass NA NORTH ENTRY PULL STATION 1 M-04 Pass NA NORTH ENTRY PULL STATION 1 M-05 Pass NA WEST EXIT PULL STATION 1 M-06 Pass NA NORTH STAIRWAY PULL STATION 1 M-33 Pass NA SECURITY BOOTH SMOKE DETECT. 1 D-10 Pass NA LOBBY ELEC. RM. (ELEV.) SMOKE DETECT. 1 D-11 Pass NA ELEV. LOBBY 1ST FLR SMOKE DETECT. 1 D-12 Pass NA ELEV. SERV. 1ST FLR ANSUL 1 M-21 Pass NA KITCHEN ANSUL STOVES ANSUL 1 M-22 Pass NA KITCHEN ANSUL FRYERS ANSUL 1 M-23 Pass NA KITCHEN ANSUL OVENS HEAT 1 M-15 Pass NA LOBBY ELEC. RM. SMOKE DETECT. LL D-14 Pass NA SERVICE ELEC. RM SMOKE DETECT. LL D-13 Pass NA ELEV. SERV. L.L. PULL STATION LL M-35 Pass NA S.W. BASEMENT HEAT LL M-16 Pass NA BASEMENT S.W.ELEC. SMOKE DETECT. LL D-03 Pass NA MAIN ELEC. RM. SMOKE DETECT. LL D-02 Pass NA MAIN ELEC. RM. SMOKE DETECT. LL D-01 Pass NA MAIN ELEC. RM. TAMPER NA M-18 Pass NA PIV TAMPER TAMPER NA M-18 Pass NA BASEMENT WET SYSTEM BUTTERFLY WATER FLOW NA M-17 Pass NA WET SYSTEM TAMPER NA M-38 Pass NA OLD CASINO WATER FLOW NA M-37 Pass NA OLD CASINO SMOKE DETECT. 1 D-16 Pass NA 1ST BREWERY ELEVATOR LOBBY Note 1 SMOKE DETECT. 2 D-17 Pass NA 2ND BREWERY ELEVATOR LOBBY Note 5 SMOKE DETECT. 1 D-19 Pass NA BREWERY ELEV ROOM HEAT DETECT, 1 M-54 Pass NA BREWERY ELEV ROOM ANSUL 1 M-43 Pass NA BREWERY PIZZA ANSUL 1 M-44 Pass NA STOVE GRILL ANSUL 1 M-45 Pass NA BREW SMOKER ANSUL TROUBLE B2 M-08 Pass NA TRBL GARAGE ALARM B2 M-07 Pass NA SUPERVISORY GARAGE SimplexGrinnell BE SAFE. 4650 Beloit Drive,Sacramento CA 95838— (916)283-0300 —(916)920-2241 25-Nov-15 FEATHER FALLS CASINO 3 ALVERDA DR OROVILLE, CA. 95966 Device Floor Zone Alarm Trouble Location Note: PWR SPLY 2 1 M-52 Pass NA HOUSEKPG CLOSET BY LUCKY ZONE PWR SPLY 1 1 M-53 Pass NA HOUSEKPG CLOSET BY LUCKY ZONE SMOKE DETECT. 1 D-15 Pass NA HOUSEKPG CLOSET BY LUCKY ZONE SMOKE DETECT. 1 D-21 Pass NA PED LINK DOOR SMOKE DETECT. 1 D 20 Pass NA PED LINK DOOR PARKING GARAGE SIMPLEX PANEL (2) 12 ah batteries PULL STATION P3 Pass NA GARAGE P3 LEVEL S. STAIRWELL PULL STATION P2 Pass NA GARAGE P2 LEVEL S. STAIRWELL PULL STATION P1 Pass NA GARAGE P1 LEVEL S. STAIRWELL PULL STATION B1 Pass NA GARAGE B1 LEVEL S. STAIRWELL PULL STATION B2 Pass NA GARAGE B2 LEVEL S. STAIRWELL HEAT DETECTOR P2 ID NET1' Pass NA GARAGE P2 LEVEL ELEV. LOBBY HEAT DETECTOR P1 ID NET1( Pass NA GARAGE P1 LEVEL ELEV. LOBBY HEAT DETECTOR B2 ID NET8 Pass NA B2 GARAGE LOBBY HEAT SMOKE DETECTR B2 ID NET 3 Pass NA B2 CONTROL ROOM SMOKE HEAT DETECTOR B1 ID NET 9 Pass NA GARAGE B1 ELEV LOBBY HEAT DETECTOR P3 ID NET1 Pass NA GARAGE P3 LEVEL ELEV. LOBBY SMOKE DETECTR B2 Pass NA ABOVE FACP PULL STATION P3 Pass NA P3 NORTH STAIRWELL PULL STATION P2 Pass NA P2 NORTH STAIRWELL PULL STATION P1 Pass NA P1 NORTH STAIRWELL PULL STATION B1 Pass NA B1 NORTH STAIRWELL PULL STATION B2 Pass NA B2 NORTH STAIRWELL PIV Pass NA PIV • SIMPleXerinnell BE SAFE 4650 Beloit Drive, Sacramento CA 95838— (916) 283-0300 — (916)920-2241 Deficiency Report Date: 11/25/2015 Customer: FEATHER FALLS CASINO Address 3 ALVERDA DR City, State OROVILLE, CA. 95966 SR # 33263094 Contact TROY 530-533-3885 Were Do Repairs Repairs need to be Made Quoted Yes/No Yes/No Panel discription needs to changed: D-16 needs to read 1st floor brewry Note 1 elevator landing. Note 2 MAIN FIRE CONTROL PANEL DID NOT SILIENCE ALARM. PANEL HAS TO RESET TO SILIENCE Note 3 Batteries in main fire panel and extender panel need to be replaced (6) 7ah Note 4 Recommend zone map for parking garage fire panel. Zoned fire panel discription does not specify location. Note 5 Panel discription needs to be changed: D-17 needs to read as 2nd floor brewry elevator landing SimplexOrinnell BE SAFE. 4650 Beloit Drive, Sacramento CA 95838 — (916) 283-0300 — (916) 920-2241 FEATHER FALLS CASINO SR# 33263094 3 ALVERDA DR IS THERE A DEFICIENCY? OROVILLE, CA. 95966 YES X NO TROY Equipment Test Report Yes No Qty Notes: Were Tested Detectors Cleaned? II NA I I If"No" answer, explain under comments Were Tested Detectors Sensitivity Tested? II NA I If"No" answer, explain under comments Did test of Duct Detectors shut down air handling units: NA Did the monitoring center receive signals? X Central Station, Fire Department, Lease Line? Is system reset for normal conditions? X Is system restored to operational service? X Operator and Time system put back on line? Operator: Time: Have proper authorities been notified system is back in service? X Indicate % of Equipment tested this report 25 50 75 100 Indicate % of equipment tested YTD 25 50 75 100 Comments for any"No" answers or explanations: Did you receive a copy of your inspection report? YES X NO If no how would you prefer to receive your report: Email: 0 FAX 0 We appreciate your business. Thank you! Customer Date ChrOjCAMI., 11/25/15 Inspector Date IF YOU HAVE ANY QUESTIONS REGARDING THIS INSPECTION AND/OR REPORT PLEASE CONTACT: Our office at 916-283-0300