Loading...
HomeMy WebLinkAboutFAI15-0097 079-230-017 CF FS 2015 25-78 INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25, as amended by CCR, Title 19 Property Information: Occupancy/Use: Casino _ Name: Feather Falls Casino Construction Type: A� F At�,NN Address: 3 Alverda Dr. No. Stories: 3 / �z4"$ g l City: Oroville, Ca. 95966 Year Constructed "43\ 4 J hI RE AM1P Contact: Troy Last 5 year Cert. Oct. 2012 Telephone: (530) 321-9289 Contractor Information: Name: SimplexGrinnell 3 Number of System Risers Address: 4650 Beloit Drive Copy sent to: City: Sacramento 0 Owner Date: 11/25/15 State: CA ❑Fire AHJ Date: Telephone: (916) 283-0300 ❑Contractor Date: CA License#: 968851 Job# 33263092 NOTES: 1) For specific inspection,testing,and maintenance requirements and Performed by: Christopher S. James (530)207-7582 information, see NFPA 25,2002 Edition as ammended by California Code (Print) Regulations,Title 19,§901 to§906. 2) Inspection Items may be performed by the Owner in accordance with California Code of Regulations Title 19§904.1(a) Note: Contractor information may be pre-printed Forms included with this report NFPA 25 Number of Forms N/A FAIL* PASS Chapter O Automatic Sprinkler System 5 x ❑ Standpipe & Hose Systems 6 ❑ Private Water Supply System 7 ❑ Fire Pump 8 ❑ Water Storage Tank 9 ❑ Water Spray System 10 ❑ Foam-Water Sprinkler Systems 11 O Valves, Valve Components&Trim 12 x * See"Deficiencies and comments" section at end of each respective form. 11/25/2015 State Fire Marshal AES 1 ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System 2 of 4 Pages NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance 11/25/15 System Riser ID: Property Information: _ Name: Feather Falls Casino Type of System: o cq!,c'tiy Address: 3 Alverda Dr. 0 Wet Pipe / ''s"+f aE 0 Dry Pipe foFuy,, City: Oroville, Ca. 95966 ❑ Preaction 4'tNP/PE ¢ ❑ Deluge Riser# Initial Static Residual Restored Static Abbreviation Key: I = Inspection T =Test M = Maintenance A-O =After Operation MI = Per Manufacturer's Instructions Item Activity Frequency Description NFPA 25 Fail N/A Pass Reference 1.1 I Daily Preaction/Deluge Valves - 12.4.3.1 x Weekly Enclosure temperature 1.2 I Daily Dry Pipe Valves - Enclosure 12.4.4.1.1 x Weekly temperature 1.3 I Quarterly Gauges (Dry, Preaction, Deluge 5.2.4.2 x Systems) 5.2.4.3 1.4 I Quarterly Control Valves 12.3.2.1 x 1.5 I Quarterly Alarm Devices 5.2.6 x 1.6 I Quarterly Gauges (Wet Pipe Systems) 5.2.4.1 x 1.7 I Quarterly Hydraulic nameplate 5.2.7 x 1.8 I Quarterly Pipe and Fittings 5.2.2 x 1.9 I Quarterly Sprinklers 5.2.1 x 1.10 I Quarterly Spare Sprinklers 5.2.1.3 x 1.11 I Quarterly Fire Department Connections 12.7.1 x 1.12 I Quarterly Alarm Valves- Exterior 12.4.1.1 x Inspection 1.13 I Quarterly Preaction/Deluge Valves - 12.4.3.1.E x Exterior Inspection 1.14 I Quarterly Pressure Reducing Valves 12.5.1.1 x 1.15 I Quarterly Dry Pipe Valves Exterior 12.4.4.1.4 x Inspection 1.16 I Quarterly Backflow Preventors 12.6.1 x 1.17 I Annually Buildings 5.2.5 x ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System 3 of 4 Pages NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance 11/25/15 System Riser ID: Property Information: _ Name: Feather Falls Casino Type of System: r_o !,c�tiy Ate" o ki Address: 3 Alverda Dr. 0 Wet Pipe / ''s"+f � / 0 Dry Pipe foFuy,, City: Oroville, Ca. 95966 ❑ Preaction sktNP/PE ¢ ❑ Deluge 1.18 I Annually Hangers 5.2.3 x 1.19 I Annually Seismic Braces 5.2.3 x 1.20 I 5 Years Hangers (Accessible concealed 5.2.3.3 x speaces) 1.21 I 5 Years Seismic Braces (Accessible 5.2.3.3 x concealed spaces) 1.22 I 5 Years Pipe and Fittings (Accessible 5.2.3.3 x concealed spaces) 1.23 I 5 Years Sprinklers (Accessible 5.2.1.1.4 x concealed spaces) 1.24 I 5 Years Alarm Valves- Interior 12.4.1.2 x Inspection 1.25 I 5 Years Alarm Valves- Strainers, filters, 12.4.1.2 x orifices 1.26 I 5 Years Check Valves - Interior 12.4.2.1 x Inspection 1.27 I 5 Years Preaction/Deluge Valves - 12.4.3.1.7 x Interior Inspection 1.28 I 5 Years Preaction/Deluge Valves - 12.4.3.1.8 x Strainers, filters, orifices 1.29 I 5 Years Dry Pipe Valves - Interior 12.4.4.1.5 x Inspection 1.30 I 5 Years Dry Pipe Valves - Strainers, 12.4.4.1.E x filters, orifices 2.1 T Annually Alarm Devices (90 Sec) 5.3.3 x 12.2.7 Main Drain Test(Enter data on 12.2.6. 2.2 T Annually Page 1) 12.2.6.1 x 12.3.3.4 2.3 T Annually Antifreeze Test 5.3.4 x 2.4 T Annually Control Valve- Position 12.3.3.1 x 2.5 T Annually Control Valve- Operation 12.3.3.1 x 2.6 T Annually Supervisory 12.3.3.5 x 2.7 T Annually Preaction Valve - Priming 12.4.3.2.1 x Water Preaction Valve Low Air 2.8 T Annually 12.4.3.2.10 x Pressure Alarm 2.9 T Annually Preaction Valve - Full Flow Trip 12.4.3.2.2 x Test ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System 4 of 4 Pages NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance 11/25/15 System Riser ID: Property Information: _ Name: Feather Falls Casino Type of System: r_o !,c�tiy Ate" o ki Address: 3 Alverda Dr. 0 Wet Pipe f ''s"+f � / 0 Dry Pipe .iFuy4 ! City: Oroville, Ca. 95966 ❑ Preaction iktE ¢ ❑ Deluge 2.10 T Annually Dry Pipe Valve- Priming Water 12.4.4.2.1 x 2.11 T Annually Dry Pipe Valve- Low Air 12.4.4.2.6 x Pressure Alarm 2.12 T Annually Dry Pipe Valve- Quick-Opening 12.4.4.2.4 x Device 2.13 T Annually Dry Pipe Valve-Trip Test 12.4.4.2.2 x 2.14 T Annually Backflow Preventer Assemblies 12.6.2 x 2.15 T 3 Years Dry Pipe Valve- Full Flow Trip 12.4.4.2.2.2 x Test 2.16 T 5 Years Gauges 5.3.2 x 2.17 T 5 Years Pressure Reducing Valve 12.5.1.2 x 2.18 T 5 Years Fire Department Connection 12.7.4 x Backflush 2.19 T 5 Years Sprinklers - Extra High 5.3.1.1.1.3 x Temprerature 2.20 T 5 Years Sprinklers - Corrosive 5.3.1.1.2 x environment or corrosive water 2.21 T 10 Years Sprinklers - Dry 5.3.1.1.1.5 x 2.22 T 20 Years Sprinklers - Fast Response 5.3.1.1.1.2 x 2.23 T 50 Years Sprinklers 5.3.1.1.1 x 2.24 T 75 Years Sprinklers 75 years in service 5.3.1.1.1.4 x 2.25 T Sprinklers manufactured prior to 5.3.1.1.1.1 x 1920- Replace 3.1 M Annually Control Valves 12.3.4 x 3.2 M Annually Preaction/Deluge Valves 12.4.3.3.2 x 3.3 M Annually Dry Pipe Valves/Quick-Opening 12.4.4.3.2 x Devices 3.4 M Annually Dry Pipe Valve Low Point 12.4.4.3.3 x Drains 3.5 M 5 Years Obstruction Investigation Chapter 13 x ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System 5 of 4 Pages NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance 11/25/15 System Riser ID: Property Information: Name: Feather Falls Casino Type of System: cq lc4tiy Address: 3 Alverda Dr. 0 Wet Pipe ''s f aE Dry Pipe City: Oroville, Ca. 95966 ❑ Preaction 'NNE ❑ Deluge Deficiencies and Comments Item Deficiencies and Comments Item number must correspond to the item number of the Activity listed above: ❑ See Continuation Page(s)) (Indicate the number of continuation pages) PASS C�ope2 $ 2... (530) 207.75f12 11/25/15 ❑ FAIL Date tqca SimplexGrinnell 4650 Beloit Drive, Sacramento CA 95838— (916) 283-0300 — (916) 920-2241 Deficiency/Signature Page Date: 11/25/2015 Customer: Feather Falls Casino Address 3 Alverda Dr. City, State Oroville, Ca. 95966 SR # 33263092 Were Do Repairs Repairs need to be Made Quoted NA Waterflow's and tampers tested YES NO Did the monitoring center receive signals? X Central Station, Fire Department, Lease Line? Is system reset for normal conditions? X Is system restored to operational service? X Operator and Time system put back on line? Operator: Time: Have proper authorities been notified system is back in service? X Did you receive a copy of your inspection report? YES X NO If no how would you prefer to receive your report: Email: FAX r We appreciate your business. Thank you! Customer (3&) 22775f12 11/25/2015