HomeMy WebLinkAboutRFI22-0725 Zoning Verification Letter Department of Development Services Paula M. Daneluk, AICP, Director Curtis Johnson, Assistant Director 7 County Center Drive T: 530.552.3700 Oroville, California 95965 F: 530.538.7785
buttecounty.net/dds
December 15, 2022
Morgan Guthier, Zoning Assistant Partner Engineering and Science, Inc. 100 E California Avenue, Suite 400
Oklahoma City, OK 73104 RE: Smucker Quality Beverages, APN 040-310-093, -094 Zoning Verification Letter Dear Morgan Guthier: The current General Plan designation for the above properties is: I (Industrial) with a Zoning Designation of GI (General Industrial). There are currently no pending rezone applications or updates to the Zoning Ordinance that may affect the Subject properties now or in the foreseeable future.
Surrounding zoning designations are as follows: north: GI, east: GI, south: VLDR (Very Low Density Residential), west: VLDR, GI and Ag-40 (Agriculture 40 acre minimum). The properties are located within the City of Chico Sphere of Influence (SOI) and are pre-zoned ML (Light
Manufacturing). There are no plans for annexation within the foreseeable future. Please visit our Parcel Look-Up Tool: https://www.buttecounty.net/dds/Planning/Documents/Parcel-Lookup-Tool to view the zoning of the subject parcel and surrounding area, by clicking on the “Layer List” icon
below and then selecting “GP2030 Zoning”. The properties are not located within a PUD or PAD. The current use as an Industrial Use (“Light
Manufacturing”) is allowed by right. I am not aware of any legal nonconforming issues associated with the subject property. Please refer to the attached Zoning Ordinance sections as they pertain to the GI zone (parking, setbacks, height, use, and densities). If you have any questions concerning this information, please contact me at 530.552.3685 or email at tweems@buttecounty.net. Sincerely,
Tristan Weems, AICP
Associate Planner Encl: Industrial, and Parking and Loading Zoning Ordinance Articles
Chapter 24 - ZONING
Article II. - Zoning Districts, Land Uses, and Development Standards
Division 5. Industrial Zones
Butte County, California, Code of Ordinances Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 1 of 11
Division 5. Industrial Zones
24-25 Purpose of the industrial zones.
A. Light Industrial (LI). The purpose of the LI zone is to allow for light industrial and service commercial uses
with little potential to create noise, odor, vibration, or other similar impacts to adjacent uses and
surrounding areas. Permitted uses in the LI zone include construction, maintenance and repair services;
equipment sales and rentals; vehicle repair, service and maintenance; research and development; light
manufacturing; and warehousing, wholesaling and distribution and emergency shelters. Limited amounts of
retail, personal services, restaurants, and pubic/quasi-public uses are permitted to serve area workers, and
ancillary retail areas are permitted for the sale of products manufactured on-site. Caretaker quarters that are
accessory to a primary use and live/work units are the only form of residential uses allowed. The maximum
permitted floor area ratio in the LI zone is four-tenths (0.4). The LI zone implements the Industrial land use
designation in the General Plan.
B. General Industrial (GI). The purpose of the GI zone is to allow for a variety of industrial and service
commercial uses in Butte County. Standards for the GI zone are intended to preserve locations for existing
and future employment-generating businesses, including both traditional businesses and innovative green
technology enterprises. In addition to the uses permitted in the LI zone, the GI zone also permits agricultural
and timber processing and heavy manufacturing with the approval of a Conditional Use Permit. The
maximum permitted floor area ratio in the GI zone is one-half (0.5). The GI zone implements the Industrial
land use designation in the General Plan.
C. Heavy Industrial (HI). The purpose of the HI zone is to allow for a full range of industrial uses, including
operations that necessitate the storage of large volumes of hazardous or unsightly materials, or which
produce dust, smoke, fumes, odors, or noise at levels that would affect surrounding uses. Uses permitted in
the HI are similar to the GI zone, except that heavy industrial uses are permitted either as-of-right or with a
Conditional Use Permit, and retail, personal service and restaurant uses are not allowed. The maximum permitted floor area ratio in the HI zone is one-half (0.5). The HI zone implements the Industrial land use
designation in the General Plan.
(Ord. No. 4062, § 1, 9-10-13; Ord. No. 4132 , § 1(Att. A), 9-12-17)
24-26 Land use regulations for industrial zones.
A. Permitted Uses. Table 24-26-1 (Permitted Land Uses in the Industrial Zones) identifies land uses permitted in
the industrial zones.
TABLE 24-26-1 PERMITTED LAND USES IN THE INDUSTRIAL ZONES [1] [2]
Key
P Permitted use, subject to Zoning
Clearance
A Administrative Permit required
C Conditional Use Permit required
Zone Applicable
Regulations LI GI HI
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 2 of 11
M Minor Use Permit required
— Use not allowed
Agricultural Uses
Agricultural Processing - C P
Animal Grazing P [4] P [4] P [4] Section 24-158
Animal Processing - - C
Animal Processing, Custom - - -
Crop Cultivation P [4] P [4] P [4]
Feed Store - - -
Intensive Animal Operations - - -
Stables, Commercial - - -
Stables, Private - - -
Stables, Semiprivate - - -
Natural Resource Uses
Forestry and Logging - - -
Mining and Surface Mining
Operations
- - C
Oil and Gas Extraction, including
reinjection wells for natural gas
- - -
Oil and Gas Extraction, Storage or
disposal of Well Stimulation
Byproducts
- - - Section 24-167.1
Oil and Gas Extraction by means of
Hydraulic Fracturing
- - - Butte County Code 33B
Timber Processing - C P
Residential Uses
Accessory Dwelling Units - - -
Agricultural Worker Housing Center - - -
Caretaker Quarters A A A
Duplex Home - - -
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 3 of 11
Home Occupations - Major - - -
Home Occupations - Minor - - -
Live/Work Unit M M - Section 24-164
Mobile Home Park - - -
Multiple-Family Dwelling - - -
Residential Care Homes, Large - - -
Residential Care Homes, Small - - -
Single-Family Home - - -
Short-Term Rental - - -
Community Uses
Cemeteries, Private - - -
Cemeteries, Public - - -
Child Care Center - - -
Child Day Care, Large - - -
Child Day Care, Small - - -
Clubs, Lodges and Private Meeting
Halls
C - -
Community Centers - - -
Correctional Institutions and
Facilities
- - -
Cultural Institutions - - -
Emergency Shelters P - - Section 24-161
Golf Courses and Country Clubs - - -
Hospital - - -
Medical Office and Clinic - - -
Office, Governmental - - -
Outdoor Education - - -
Parks and Recreational Facilities - - -
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 4 of 11
Public Safety Facilities C C C
Religious Facilities M - -
Schools, Public and Private M M -
Water Ski Lakes - - -
Commercial Uses
Adult Businesses — C C County Code Chapter
15, Article 4
Agricultural Product Sales, Off-Site - - -
Agricultural Product Sales, On-Site - - -
Agricultural Support Services,
General
- - -
Agricultural Support Services, Light - - -
Animal Processing, Limited - - -
Animal Services P P -
Bars, Nightclubs and Lounges - - -
Bed and Breakfast - - -
Commercial Recreation, Indoor M M -
Commercial Recreation, Outdoor - - -
Construction, Maintenance and
Repair Services
P P P
Drive-Through Facility A A A Section 24-160
Equipment Sales and Rentals P P P
Firewood Storage, Processing and
Off-Site Sales, Small
- P P
Firewood Storage, Processing and
Off-Site Sales, Medium
- M P
Firewood Storage, Processing and
Off-Site/On-Site Sales, Large
- M P
Gas and Service Stations - - -
Heavy Equipment Storage P P P Section 24-173
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 5 of 11
Hotel and Motel - - -
Hunting and Fishing Clubs - - -
Offices, Professional - - -
Nursery, Retail - - -
Nursery, Wholesale
Personal Services A A -
Personal Services, Restricted - - -
Public/Mini Storage P P - Section 24-169
Recreational Vehicle Parks - - -
Restaurant A A -
Retail, General A A -
Retail, Large Projects - - -
Retail, Restricted - - -
Vehicle Repair P P P
Vehicle Sales and Rental M M M
Vehicle Service and Maintenance P P P
Wine, Olive Oil, Fruit and Nut,
Micro-Brewery and Micro-Distillery
Facilities
- - -
Industrial Uses
Composting Facilities - C P
Manufacturing, General C P P
Manufacturing, Heavy - C C
Manufacturing, Light P P P
Research and Development P P P
Warehousing, Wholesaling and
Distribution
P P P
Transportation, Communication, and Utility Uses
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 6 of 11
Aerial Applicator and Support
Services
- - -
Airport-Related Uses - - -
Farm Airstrips - - -
Freight and Truck Terminals and
Yards
C P P
Recycling Collection Facility, Large A A A Section 24-170
Recycling Collection Facility, Small A A A Section 24-170
Recycling Processing Facility, Heavy C M A Section 24-170
Recycling Processing Facility, Light M M A Section 24-170
Reverse Vending Machine A A A Section 24-170
Runways and Heliports - C C
Telecommunications Facilities See Article 26
Utilities, Major C C C Section 24-157
Utilities, Intermediate M M M Section 24-157
Utilities, Accessory [3] A A A Section 24-157
Utilities, Minor P P P Section 24-157
Other Uses
Accessory Uses and Structures See Section 24-156
Notes:
[1] See Article 42 (Glossary) for definitions of listed land uses.
[2] Standards in the Zoning Ordinance that apply to specific uses are identified under the column
"Applicable Regulations," defined under Section 24-8G.5, and are intended to direct the reader to a
section that is related to the use.
[3] Agricultural Wind Energy System not allowed in any Industrial Zone.
[4] Permitted only as an interim use on parcels of one (1) acre or more in size prior to subdivision and
development with industrial uses.
(Ord. No. 4062, § 1, 9-10-13; Ord. No. 4091, § 1, 1-27-15; Ord. No. 4094, § 6, 4-21-15; Ord. No. 4105, § 1, 1-12-16 ;
Ord. No. 4132 , § 1(Att. A), 9-12-17; Ord. No. 4134 , § 1(Att. A), 9-26-17; Ord. No. 4159 , § 1(Att. A), 3-26-19; Ord.
No. 4161 , § 1(Att. A), 5-7-19; Ord. No. 4197 , § 7, 1-12-21)
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 7 of 11
24-27 Development standards for industrial zones.
A. Parcel Size and Density. Table 24-27-1 (Parcel Size and Intensity Standards for Industrial Zones) identifies the
parcel size and intensity standards that apply in industrial zones.
TABLE 24-27-1 PARCEL SIZE AND INTENSITY STANDARDS FOR INDUSTRIAL ZONES
Parcel Area (min.)[1] Parcel Width (min.) FAR (max.)
LI 10,000 sq. ft. 65 ft. 0.4
HI 10,000 sq. ft. 65 ft. 0.5
GI 10,000 sq. ft. 65 ft. 0.5
Notes:
[1] Applies only to the creation of new parcels.
B. Structure Setbacks and Height. Table 24-27-2 (Setback and Height Standards for Industrial Zones) identifies
structure setback and height standards that apply in industrial zones.
TABLE 24-27-2 SETBACK AND HEIGHT STANDARDS FOR INDUSTRIAL ZONES
Zone
LI GI HI Additional
Standards
Setbacks [1]
Front None, except 50 ft. when adjacent to a
residential zone
Article III, Division 2
(Setback Requirements
and Exceptions)
Article III, Division 6
(Riparian Areas)
Interior Side None, except 50 ft. when adjacent to a
residential zone
Street Side None, except 50 ft. when adjacent to a
residential zone
Rear None, except 50 ft. when adjacent to a
residential zone
Structure Height (max.) [2] 50 ft. 50 ft. 50 ft. Article III, Division 1
(Height Measurements and
Exceptions)
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 8 of 11
Notes:
[1] Buildings on corner lots in Industrial zones shall be designed to provide for adequate and safe sight
distance for vehicles at adjacent intersections as approved by the Director of Public Works.
[2] Structures associated with industrial operations may exceed fifty (50) feet in height provided they do
not exceed height restrictions in regulated airport approach zones. Such structures shall not exceed the
maximum height necessary to perform its intended function.
C. Industrial Buffer Yards.
1. Industrial Buffer Yard Defined. An industrial buffer yard is an area of plantings and walls that shields
neighboring residential properties from negative impacts created by industrial land uses.
2. When Required. An industrial buffer yard is required for any development within an industrial zone
that is adjacent to a residential zone.
3. Buffer Yard Standards.
a. Industrial buffer yards shall be located along the outer perimeter of a property line abutting a
residential zone. See Figure 24-27-1 (Industrial Buffer Yards).
b. The minimum width of an industrial buffer yard shall be twenty-five (25) feet located within the
fifty (50) foot minimum setback area. See Figure 34-27-1 (Industrial Buffer Yards).
c. Industrial buffer yards shall include a solid masonry or equivalent wall no less than six (6) feet in
height.
d. Industrial buffer yards shall be planted with a mix of deciduous and evergreen trees and shrubs
of suitable type, size, and spacing to achieve screening year-round.
e. All plantings within an industrial buffer yard shall be maintained in a manner consistent with
Section 24-118 (Maintenance) in Article III, Division 11 (Landscaping).
f. Paved surfaces shall be prohibited within industrial buffer yards. Buffer yards shall not be used
for parking, driveways, trash enclosures, building areas, or any other activity associated with the
primary use on the property.
FIGURE 24-27-1 INDUSTRIAL BUFFER YARDS
(Ord. No. 4062, § 1, 9-10-13; Ord. No. 4105, § 1, 1-12-16 )
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 9 of 11
24-32 Planned development zone requirements.
A. General Rezoning Requirements. In addition to the requirements contained in this section, the rezoning of
any parcel to Planned Development (PD) shall comply with the requirements for a Zoning Ordinance Map
Amendment as specified in Article VI, Division 6 (Zoning Ordinance Amendments).
B. Minimum Parcel Size. The minimum size of a site proposed for rezoning to the PD zone is three (3) acres.
C. Pre-Application Conference. Prospective applicants are required to request a pre-application conference
with the Department of Development Services before completing and filing an application for a PD rezoning.
At the pre-application conference, prospective applicants shall describe the general concepts of the
development project, including site layout, land uses, building height and bulk standards, circulation, and
other information necessary to describe key aspects of the project. The Department of Development Services
shall provide preliminary feedback on the described development project relative to project consistency with
County policies. The Department of Development Services shall also review with the prospective applicant
submittal requirements for a PD rezoning and the process for application review and action by the Planning
Commission and Board of Supervisors.
D. Application Submittal. An application for a PD rezoning shall be filed in compliance with Article V, Division 1
(Permit Application and Review). The application shall include the information and materials specified in the
Department of Development Services handout for Zoning Ordinance Map Amendments, in addition to the
following materials:
1. Project Description. The applicant shall provide a written description of the project proposed within
the PD zone. The project description shall include a narrative statement of the project's objectives and
a statement of how the proposed project will comply with General Plan goals and policies for the land
use designation of the project site. The project description may also include a diagram illustrating the
proposed project.
2. Site Map. The application shall include maps depicting the existing topography, on-site structures and
natural features, mature trees, and other significant vegetation and drainage patterns. The map shall
show the proposed PD zone boundaries and all properties within three hundred (300) feet of the site
boundary. The map shall be accompanied by a description of the type and condition of mature trees.
3. Parcel or Subdivision Map. If the project within the proposed PD zone involves the subdivision of land,
the application shall include a tentative parcel map or tentative subdivision map as required by Chapter
20 (Subdivisions) of the Butte County Code.
4. Infrastructure. The application shall include a written description of the infrastructure necessary to
serve each phase of the project proposed within the PD zone.
5. Public Facilities Financing Plan. If the proposed project will not be adequately served by existing public
infrastructure and facilities or through the adopted countywide impact fee program, the application
shall include a public facilities financing plan that identifies the needed public improvements and
establishes a plan to pay for and develop the required public improvements.
6. Open Space Summary.
a. The open space summary shall include the amount (in square feet or acres) and percentage of
site area that will be provided as total open space, private open space, common open space, and
usable open space, as applicable. The summary shall also include a description of all open space
areas, including proposed recreational facilities and amenities.
b. In residential PD projects, not less than twenty-five (25) percent of the residential portion of the
project shall be utilized for purposes other than residential dwellings and paved areas for
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 10 of 11
vehicular uses. No less than forty-five (45) percent of such twenty-five (25) percent shall be
utilized for recreation or park areas available for use by all residents. The same criteria for open
space area shall apply to agricultural PD projects which may or may not include residential uses.
For industrial or commercial PD projects, not less than ten (10) percent of the project shall be
developed as landscaped areas.
7. Development Plan. The application for a PD rezoning shall be accompanied by a Development Plan that
includes the following information about the project proposed for the PD zone:
a. Land Use. The Development Plan shall include a map showing the location of each land use
proposed within the site, including open space and common areas. The land use map shall be
accompanied by a narrative description of permitted land uses, allowable accessory uses, and
uses allowed with a Conditional Use Permit.
b. Subdivision Regulations. The Development Plan shall include a Subdivision Map (if a subdivision is
proposed), including minimum parcel area and minimum parcel dimensions.
c. Circulation. The Development Plan shall include a map and narrative of the major circulation
features within the site, including vehicular, bicycle, and pedestrian facilities, as applicable.
d. Development Standards. The Development Plan shall identify development standards for all
structures within the site, including, but not limited to, density, setback, structure height, site
coverage, and parking requirements.
e. Design Guidelines. The Development Plan shall include design guidelines pertaining to
development features such as landscaping; building materials; fences, walls and screenings; and
open spaces.
E. Planning Commission Review and Recommendation.
1. The Planning Commission shall hold a public hearing on the PD rezoning application as required by
Article VI, Division 6 (Zoning Ordinance Amendments). The Planning Commission shall consider the full
PD rezoning application at this hearing, including the Development Plan.
2. The Planning Commission shall forward a written recommendation, and reasons for the
recommendation, on the proposed PD rezoning and Development Plan to the Board of Supervisors.
The recommendation shall be based on the findings in Subsection G (Findings), in addition to the
Zoning Ordinance Map Amendment findings specified in Section 24-275 (Findings and Decision).
F. Board of Supervisors Review and Decision. Upon receipt of the Planning Commission's recommendation, the
Board of Supervisors shall conduct a public hearing and either approve, approve in modified form, or deny
the PD rezoning and Development Plan. The Board of Supervisors may approve the application only if all of
the findings in Subsection G (Findings) below can be made, in addition to the Zoning Ordinance Map
Amendment findings specified in Section 24-275 (Findings and Decision).
G. Findings. The Board of Supervisors may approve an application for PD rezoning with accompanying
Development Plan only if all of the following findings can be made:
1. The proposed development is consistent with the goals, policies, and actions of the General Plan and
any applicable specific plan and community plan.
2. The site for the proposed development is adequate in size and shape to accommodate proposed land
uses.
3. The site for the proposed development has adequate access considering the limitations of existing and
planned streets and highways.
4. Adequate public services exist or will be provided to serve the proposed development.
Created: 2021-08-02 11:23:51 [EST]
(Supp. No. 52)
Page 11 of 11
5. The proposed development will not have a substantial adverse effect on surrounding property and will
be compatible with the existing and planned land use character of the surrounding area.
6. In coordination with the applicable school district, the proposed development shall dedicate adequate
and appropriately-located land for school district facilities that are needed to serve residents within the
project.
7. The proposed development carries out the intent of the PD zone by providing a more efficient use of
the land and an excellence of site design greater than that which could be achieved through the
application of established zoning standards.
H. Ordinance Approving the Development Plan. If the Board of Supervisors approves the establishment of a PD
zone, it shall do so by adoption of an ordinance and adoption by reference of the Development Plan. The
ordinance shall also include any other provisions that the Board of Supervisors finds to be necessary to
constitute the regulations for use, property maintenance, and property improvement in the PD zone.
I. Effect of Development Plan. All proposed development and new land uses within a PD zone shall comply with
the approved Development Plan.
J. Minor Modifications. Modifications to an approved Development Plan shall be approved as specified in
Section 24-246 (Changes to an Approved Project).
(Ord. No. 4062, § 1, 9-10-13)
PARKING AND LOADING 24-91
137
PARKING AND LOADING
Sections:
24-91 – Purpose
24-92 – Applicability
24-93 – On-Site Parking Requirements
24-94 – General Requirements
24-95 – Parking Design Standards
24-96 – Bicycle Facilities
24-97 – On-Site Loading
24-91 Purpose
This article establishes standards for vehicle parking facilities, freight loading areas, and related transportation
infrastructure. These standards are intended to:
A. Ensure a sufficient supply of on-site parking and loading facilities for all land uses;
B. Provide parking design standards appropriate for both urban and rural areas;
C. Promote the use of alternative forms of transportation;
D. Protect neighborhoods from vehicular noise and traffic associated with adjacent non-residential land
uses; and
E. Ensure the maneuverability of emergency vehicles.
24-92 Applicability
A. New Structures and Uses. All new structures and uses proposed or established after the effective
date of the Zoning Ordinance shall comply with the standards in this article.
B. Existing Structures and Uses. When an existing structure or use is expanded, on-site parking as
required by this article shall be provided only as needed to accommodate the expanded portion of the
structure or use.
C. Replaced Uses. A new use that replaces an existing use shall provide parking only for the additional
parking required for the new use beyond that which was required by the existing use.
24-93 On-Site Parking Requirements
A. Number of Spaces. All land uses shall provide on-site parking as required in Table 24-93-1 (On-Site
Parking Requirements).
B. Unlisted Uses.
The Zoning Administrator shall determine on-site parking requirements for uses not listed in
Table 24-93-1 (On-Site Parking Requirements).
24-93 PARKING AND LOADING
138
TABLE 24-93-1 ON-SITE PARKING REQUIREMENTS
Uses, Activities, and Facilities Number of Required Parking Spaces
Agricultural Uses
Stables, Commercial 1 per 4 stalls
Natural Resource Uses
Forestry and Logging
1 per 1,000 sq. ft. of floor area for all habitable structures associated with the
use, or one space per employee, whichever is greater.
Mining and Surface Mining Operations
Oil and Gas Extraction, including reinjection wells
for natural gas
Timber Processing
Residential Uses
Agricultural Worker Housing Centers Group quarters: 1 per 4 beds
Dwelling units: 2 per dwelling
Caretaker Quarters 1 per dwelling
Duplex Homes 2 per dwelling
Live/Work Units 1 per unit
Mobile Home Parks 1 per dwelling plus 1 guest space for every 5 dwellings and 1 recreational
vehicle parking space for every 5 dwellings
Multiple-Family Dwellings
Studio Units: 1 per dwelling
One-Bedroom Units: 1.5 per dwelling
Two-or-more-Bedroom Units: 2 per dwelling
Residential Care Homes 1 per 4 beds plus 1 per 300 sq. ft. of office and other non-residential areas
Second Units and Accessory Dwelling Units 1 per dwelling
Single-Family Homes 2 per dwelling
Community Uses
Cemeteries 1 per 6 seats in a chapel or other assembly area
Child Care Centers 1 per 400 sq. ft. of floor area
Child Day Care, Large 2 in addition to the spaces required for the primary use
Child Day Care, Small 1 in addition to the spaces required for the primary use
Clubs, Lodges and Private Meeting Halls 1 per 200 sq. ft. of floor area
Community Centers 1 per 300 sq. ft. of floor area
Correctional Institutions and Facilities 1 per 2,000 sq. ft. of floor area
Cultural Institutions Theatres and auditoriums: 1 per 4 seats
Other areas accessible to the public: 1 per 300 sq. ft.
Emergency Shelters 1 per 8 beds plus 1 per 300 sq. ft. of office or other non-residential area
PARKING AND LOADING 24-93
139
Uses, Activities, and Facilities Number of Required Parking Spaces
Golf Courses and Country Clubs 1 per hole plus 1 per 300 sq. ft. of floor area
Hospitals 1 per 400 sq. ft. of floor area or as determined by a parking demand analysis
and specified in the Conditional Use Permit
Medical Offices and Clinics 1 per 300 sq. ft. of floor area
Offices, Governmental 1 per 300 sq. ft. of floor area
Parks and Recreational Facilities As determined by a parking demand analysis and/or specified in the
Conditional Use Permit Public Safety Facilities
Religious Facilities 1 per 6 seats plus 1 per 300 sq. ft. of classroom or office area
Schools, Public and Private As determined by a parking demand analysis and/or specified in the
Conditional Use Permit
Water Ski Lakes As determined by a parking demand analysis and specified in the Conditional
Use Permit
Commercial Uses
Adult Businesses 1 per 350 sq. ft. of floor area
Agricultural Product Sales 1 per 300 sq. ft. of display and sales area
Agricultural Support Services, General 1 per 1,000 sq. ft. of floor area for all habitable structures associated with the
use Agricultural Support Services, Light
Animal Services 1 space per 350 sq. ft. of floor area
Bars, Nightclubs and Lounges 1 per 3 seats or 1 per 200 sq. ft. of floor area, whichever is greater
Bed and Breakfasts 1 per guestroom, plus 2 for resident manager
Commercial Recreation, Indoor 1 per 350 sq. ft. of floor area
Commercial Recreation, Outdoor 1 per 4 seats or 4-person capacity or 1 per 200 sq. ft. of floor area used by
customers, whichever is greater
Construction, Maintenance and Repair Services 1 per 300 sq. ft. of floor area
Drive-thru Facilities 1 per 350 sq. ft. of floor area
Equipment Sales and Rental 1 per 400 sq. ft. of floor area
Gas and Service Stations 1 per 300 sq. ft. of floor area plus 1 per 4 pump stations
Hotels and Motels 1 per room plus 1 per 300 sq. ft. of office area
Hunting and Fishing Clubs 1 per 400 sq. ft. of lodge or meeting space floor area
Medical Offices and Clinics
1 per 300 sq. ft. of gross floor area Offices, Professional
Nursery, Retail
24-93 PARKING AND LOADING
140
Uses, Activities, and Facilities Number of Required Parking Spaces
Nursery, Wholesale
Personal Services
Personal Services, Restricted
Public/Mini Storage 1 space per 100 storage units or 5 spaces, whichever is greater
Restaurants 1 per 4 seats or 1 per 300 sq. ft. of floor area, whichever is greater
Recreational Vehicle Parks 1 per recreational vehicle space
Retail, General
1 per 300 sq. ft. of floor area Retail, Large Projects
Retail, Restricted
Shopping Centers
Special Events 1 per 4 seats or for 4 people based on maximum occupancy, whichever is
greater
Vehicle Repair
1 per 400 sq. ft. of floor area, but in no case less than 6 spaces Vehicle Sales and Rental
Vehicle Service and Maintenance
Wineries and Olive Oil, Fruit and Nut, Micro-
Brewery and Micro-Distillery Facilities 1 per 300 sq. ft. of floor area
Industrial Uses
Manufacturing and Processing, Light
1 per 1,000 sq. ft. of floor area
Manufacturing and Processing, General
Manufacturing and Processing, Heavy
Research and Development 1 per 1,000 sq. ft. of laboratory or manufacturing area and 1 per 300 sq. ft.
of the remaining area
Warehousing, Wholesaling and Distribution 1 space for each 2,000 sq. ft. of floor area
Transportation, Communications and Utility Uses
Airport Related Uses 1 space for each 2,000 sq. ft. of floor area, or as determined by a parking
demand analysis and/or specified in the Conditional Use Permit
Composting Facilities 1 per 1,000 sq. ft. of floor area
Freight and Truck Terminals and Yards 1 per 2,000 sq. ft. of floor area
Recycling Facilities 1 per 1,000 sq. ft. of floor area
Runways and Heliports As determined by a parking demand analysis and/or specified in the
Conditional Use Permit
PARKING AND LOADING 24-94
141
Uses, Activities, and Facilities Number of Required Parking Spaces
Telecommunications Facilities 2 per unit or 1 per employee, whichever is greater.
Utilities As determined by a parking needs assessment and/or specified in the
Conditional Use Permit
On-site parking requirements for unlisted uses shall be based on the parking requirements of
similar uses in Table 24-93-1(On-Site Parking Requirements).
The Zoning Administrator may require the preparation of a parking demand study to determine
the parking requirement for unlisted uses.
C. Multiple Uses. When more than one land use is conducted on a parcel, the required number of
parking spaces shall be the sum of the number of parking spaces required for each individual use, or as
determined by a parking demand study.
D. Unknown Uses.
The Zoning Administrator shall determine on-site parking requirements for non-residential “shell”
structures with no identified tenants.
Parking requirements shall be based on anticipated tenants for the structures, as determined by the
Zoning Administrator.
E. Fractional Spaces. If the number of required parking spaces does not result in a whole number, the
number shall be rounded down to the nearest whole number.
F. Availability and Use of Spaces.
Required parking spaces shall be permanently available and maintained for parking purposes for
the use they are intended to serve.
Owners, lessees, tenants, or persons having control of the operation of a use for which parking
spaces are required shall not prevent or restrict authorized persons from using these spaces.
Required parking spaces shall be used exclusively for the temporary parking of vehicles and shall
not be used for the sale, lease, display, repair, or storage of vehicles, trailers, boats, campers,
mobile homes, merchandise, or equipment, or for any other use not authorized by the Zoning
Ordinance.
24-94 General Requirements
A. Use and Availability.
All on-site parking facilities shall be designed and maintained to be fully usable for the duration of
the use.
Areas required to meet applicable parking requirements may not be used for any other purpose.
24-94 PARKING AND LOADING
142
B. Parking for Persons with Disabilities.
Parking facilities shall be properly designed, constructed, and maintained to provide for access by
the physically disabled from public rights-of-way, across intervening parking spaces, and into
structures.
The number of parking spaces for the disabled shall be as required by the California Building
Code, the Federal Accessibility Guidelines, and the California Code of Regulations (Title 24, Part
2, Chapter 2-71).
Parking spaces required for the disabled shall count toward compliance with the number of
parking spaces required by Table 24-93-1 (On-Site Parking Requirements).
C. Parking for Motorcycles.
The minimum number of motorcycle parking areas shall be provided as shown in Table 24-94-1
(Motorcycle Parking Requirements).
TABLE 24-94-1 MOTORCYCLE PARKING REQUIREMENTS
Number of Automobile Spaces Required Number of Motorcycle Parking Areas Required
1 — 25 spaces None required
26 — 100 spaces One area
Over 100 spaces One area for each additional 100 automobile spaces or portion thereof
One motorcycle parking area may count towards fulfilling the requirement for one automobile
parking space.
A motorcycle parking area shall be a minimum of 56 square feet in area and a minimum 8 feet
wide in its longest dimension.
All motorcycle parking areas shall have bollards installed and appropriately spaced to prevent
automobile usage. Motorcycle parking areas shall be clearly marked.
Motorcycle parking areas shall be paved with concrete to prevent damage from motorcycle kick
and center stands.
D. Off-Site Parking.
The County may approve required parking off-site if a covenant for the maintenance and
continued use of such parking facilities is approved by County Counsel and filed with the County
Recorder. The covenant shall state that the off-site parking spaces will remain available for the
duration of the use that it is to serve.
Off-site parking shall be located no more than 200 feet from the site of the use that it is intended
to serve or as close to this standard as possible.
PARKING AND LOADING 24-95
143
E. Reductions to the Required Number. Required on-site parking as specified in Table 24-93-1 (On-
Site Parking Requirements) may be reduced with Planning Commission approval of a Conditional Use
Permit. The Planning Commission may grant a reduction in required parking when one or more of the
following conditions exist:
Shared Parking. Multiple uses may use joint parking facilities when operations for the uses are
not normally conducted during the same hours, or when hours of peak use differ. Requests for
the use of shared parking may be approved if:
a. A parking demand study approved by the Zoning Administrator demonstrates that there will
be no substantial conflicts between the uses’ principal hours of operation and periods of
peak parking demand;
b. The total number of parking spaces required for the uses does not exceed the number of
parking spaces anticipated at periods of maximum use; and
c. The proposed joint parking facility is not located farther than 400 feet from the uses which it
serves.
Low Demand. The number of parking spaces may be reduced if the use will not utilize the
required number of spaces due to the nature of the specific use, as demonstrated by a parking
demand study approved by the Zoning Administrator.
Transportation Management Plan. The number of required parking spaces may be decreased,
subject to Planning Commission approval of an alternate commute mode awareness plan.
Bus Stop/Transportation Facility Credit. Required parking spaces may be reduced by up to 5
percent for a commercial or multiple-family development project within 1,500 feet of a
transportation facility.
Mixed-Use Projects. If supported by a parking use study approved by the Zoning
Administrator, a mixed-use project with commercial and residential units may reduce parking
requirements up to 50 percent for either the commercial or residential use, whichever parking
requirement is smaller. A mixed-use project with both office and commercial uses may reduce
parking requirements up to 75 percent for either the office or commercial uses, whichever parking
requirement is smaller.
24-95 Parking Design Standards
A. Standards that Apply in All Zones. The following parking design standards shall apply in all zones.
Dimensions.
a. Standard parking spaces shall be 9 feet wide by 19 feet long.
b. Angled and parallel parking spaces and parking lot aisles shall comply with the dimensions in
Table 24-95-1 (Minimum Angled and Parallel Parking Stall Dimensions) and Figure 24-95-1
(Parking Dimension Standards).
24-95 PARKING AND LOADING
144
TABLE 24-95-1 MINIMUM ANGLED AND PARALLEL PARKING STALL DIMENSIONS
Angle Stall Width Stall Depth Aisle Width
90° 9 feet 19 feet 25 feet
60° 9 feet 19 feet 18 feet
45° 9 feet 19 feet 13 feet
30° 9 feet 19 feet 11 feet
0° (parallel) 8 feet 22 feet 11 feet
FIGURE 24-95-1 PARKING DIMENSION STANDARDS
PARKING AND LOADING 24-95
145
Surfacing.
a. All parking areas shall be surfaced with a dust-minimizing treatment or paved with asphalt,
concrete or other all-weather surface.
b. Permeable paving materials such as porous concrete/asphalt, open-jointed pavers, and
turf/gravel grids are a permitted surface material.
c. The use of light colored materials to help reduce surface temperatures is encouraged.
Road Access. All parking areas shall provide suitable maneuvering room so that all vehicles may
enter and exit an abutting street in a forward direction.
Drainage. Drainage for all parking areas shall comply with the requirements of the Department
of Public Works.
Maintenance. All parking facilities shall be permanently maintained free of weeds, litter, and
debris.
Lighting. All outdoor lighting used to illuminate parking areas shall comply with the
requirements of Section 24-67 (Standards) in Article 14 (Outdoor Lighting).
Driveways. A residential parcel with vehicular access from a major or secondary arterial shall
provide, if space allows, a circular driveway or turnaround so that vehicles may enter and exit the
street in a forward motion.
Compact Parking Stalls.
a. Parking facilities may provide compact parking stalls for no more than 10 percent of the
total required parking spaces.
b. The dimensions and design of compact parking stalls shall be a minimum 8 feet wide by 16
feet long.
c. All parking spaces for compact cars shall be clearly marked with the word “Compact” either
on the wheel stop or curb, or on the pavement at the opening of the space.
d. Compact parking stalls shall be reasonably dispersed throughout the parking area.
B. Urban Zone Standards. The following standards shall apply only in urban zones.
Labels and Markings.
a. All spaces reserved for carpools and vanpools shall be clearly marked with the words
“Carpool Only” or “Vanpool Only” on either the wheel stop or curb at the back of each
space, or on the pavement at the opening of the space.
b. Within multiple-family residential developments, required guest parking spaces shall be
clearly marked with the word “Guest” either on the wheel stop or curb at the back of each
space, or the pavement at the opening of the space.
Pedestrian Access.
a. Commercial and office developments with more than 100 parking spaces shall include
pedestrian walkways at a minimum width of 4 feet connecting the furthest distance of the
parking area to the building which it serves.
24-95 PARKING AND LOADING
146
b. Pedestrian walkways shall be clearly visible and distinguished from parking spaces and areas
for vehicle circulation through striping, use of alternative paving materials, or other method
approved by the Zoning Administrator.
Wheel Stops and Curbs.
a. Drive aisles and parking surfaces contiguous with planter areas shall have a six-inch raised
curb separation.
b. All parking spaces located adjacent to buildings or walls shall have concrete wheel stops
located at least 2 feet from the building or wall.
Passenger Loading Areas.
a. Passenger loading areas shall be provided for any building or building complex that will
generate 100 or more employees at maximum occupancy. Such areas shall be located
convenient to the primary employee entrances, and shall be designated either by signs or
painted pavement.
b. Passenger loading areas shall be designed so that vehicles can safely stop and discharge
passengers.
Lighting. All employee and visitor parking areas shall include lighting capable of providing
adequate illumination for security and safety. Lighting fixtures shall be placed to avoid
interference with mature trees and other required landscaping.
Landscaping. Parking areas shall comply with the following landscaping standards, as illustrated
in Figure 24-95-2 (Parking Lot Landscaping Standards).
a. Street Frontage Landscaping.
1. When a parking lot is located adjacent to a public or private street, or a main drive aisle
that functions as a street, a 10-foot landscaped strip shall be provided between the
parking area and the street or drive aisle.
2. The landscape strip may not contain any paved surfaces, except for pedestrian walkways
or vehicular drives that cross the strip.
b. Landscaping Adjacent to a Residential Use.
1. When a parking lot is located adjacent to a residential zone, an 8-foot landscaped strip
shall be provided between the parking area and the street, drive aisle or residential
property.
2. The landscape strip may not contain any paved surfaces, excepting pedestrian walkways
or vehicular drives that cross the strip.
c. Parking Lot Landscaping.
1. Within parking lots, landscaping shall be provided as specified by Table 24-95-2
(Residential/Commercial/Industrial Interior Parking Lot Landscape Requirements).
For the purposes of this section, parking lot landscaping is defined as any landscaped
area surrounded on at least two sides by parking spaces or drive aisles, excluding those
areas around the site or structure perimeter.
PARKING AND LOADING 24-95
147
TABLE 24-95-2 RESIDENTIAL/COMMERCIAL/INDUSTRIAL INTERIOR PARKING LOT
LANDSCAPE REQUIREMENTS
Total Area of Site (Project)
Percent of Surface Parking Lot
to be Landscaped
Less than 1 acre 5%
1 to 3 acres 10%
More than 3 acres 15%
FIGURE 24-95-2 PARKING LOT LANDSCAPING STANDARDS
d. Landscape Islands.
1. All rows of parking spaces shall feature landscape islands at each row terminus to
protect parked vehicles, ensure visibility, confine moving traffic to drive aisles and
driveways, and provide space for landscaping.
2. Landscape islands shall be provided within each row of parking spaces so as to prevent
more than ten vehicles from being parked side-by-side in an abutting configuration.
3. An island for a single row of parking spaces shall contain at least one tree and vegetative
groundcover or turf.
24-95 PARKING AND LOADING
148
4. An island for a double row of parking spaces shall contain at least two trees and
vegetative groundcover or turf.
e. Concrete Curbs.
1. All landscape areas within parking lots shall be separated from parking spaces, drive
aisles, and driveways by a continuous, raised concrete curb to protect landscaped areas
from encroachment by vehicular traffic.
2. The concrete curb shall be a minimum of 6 inches high by 6 inches wide, except where a
landscape area is parallel and adjacent to a parking stall, the curb shall be a minimum of
6 inches high by 12 inches wide to provide an area for persons to step when entering or
exiting a motor vehicle.
f. Shade Trees.
1. Shade trees shall be provided within parking lots so that within 10 years of planting
50 percent of the parking area is shaded at the summer solstice (June 21).
2. At least one tree shall be provided for every four parking spaces, with the maximum
spacing between trees or clusters of trees not to exceed 30 feet.
3. This requirement is waived if 50 percent or more of the parking lot is covered by a Solar
Canopv (Butte County Code Section 24-157 C.8.). If less than 50 percent of the parking
lot is covered by a solar canopy, shade trees shall be used to reach the 50 percent
requirement.
g. Permanent Landscaped Areas. All areas not used for driveways, maneuvering areas, parking
spaces, or walks within a parking area shall be permanently landscaped with suitable
materials and permanently maintained.
h. Rainwater Management. Rainwater shall be managed on-site with designs that encourage
infiltration, evapotranspiration, and water re-use by:
1. Utilizing permeable paving for parking spaces, drive aisles, overflow parking, and other
hard surfaces in the parking lot, where applicable;
2. Planting trees, shrubs, and other permeable landscaping throughout the parking lot to
provide shade and places for water infiltration;
3. Creating bio-retention areas, such as swales, vegetated islands and overflow ponds; and
4. Incorporating opportunities to harvest rainwater (active or passive) from rooftops and
other hard surfaces for landscape irrigation.
i. Solar Panel Exemptions. Parking lots that incorporate solar panels into the parking lot
design are eligible for reduced parking lot landscaping requirements with the approval of a
Minor Use Permit.
Screening. Within commercial and industrial zones, parking areas that abut residentially zoned
property shall be screened by a row of densely planted evergreen trees or similar landscaping.
Access to Right-of-Way. Any parking lot or loading facility with vehicular access to or across a
public right-of-way shall meet the following standards:
a. Joint access ways serving adjacent uses shall be provided wherever possible as a means to
minimize curb cuts and avoid breaks in the continuity of street frontages.
b. The maximum allowed width for a residential curb cut shall be 24 feet. The maximum
allowed width for a non-residential curb cut shall be 35 feet.
PARKING AND LOADING 24-96
149
Driveways.
a. Driveways for single-family residences shall be at least 10 feet wide.
b. All other driveways or aisles shall be at least 12 feet wide for one-way traffic and 20 feet wide
for two-way traffic.
24-96 Bicycle Facilities
A. Applicability. The following bicycle facility standards shall apply only in urban zones
B. Parking for Bicycles.
For non-residential uses, bicycle parking spaces shall be provided at a rate appropriate for the use.
Spaces may be in the form of racks (for more transient use) or lockers (for long-term use by
employees).
For multiple-family housing, bicycle parking spaces shall be provided at a rate equal to ten percent
of the total required parking spaces.
Bicycle parking shall be located in highly visible locations and weather protected areas.
Bicycle and automobile parking areas shall be separated from one another by a physical barrier or
sufficient distance to protect bicycles and their riders from damage.
Bicycle parking and storage areas shall be paved with asphalt, concrete, or other all-weather
surface.
C. Shower Facilities.
Employee shower facilities and dressing areas shall be provided in new and rehabilitated buildings
that result in a total floor area as identified in Table 24-96-1 (Shower Facilities Required for
Employees).
TABLE 24-96-1 SHOWER FACILITIES REQUIRED FOR EMPLOYEES
Use 1 Shower per Gender 1 Additional Shower per Gender
Commercial 50,000 sq. ft. to 200,000 sq. ft. At 200,001 sq. ft. and every 200,000 sq. ft. over 200,000
sq. ft.
Office 50,000 sq. ft. to 150,000 sq. ft. At 150,001 sq. ft. and every 100,000 sq. ft. over 150,000
sq. ft.
Industrial 100,000 sq. ft. to 300,000 sq. ft At 300,001 sq. ft. and every 200,000 sq. ft. over 300,000
sq. ft.
24-97 On-Site Loading
A. General Requirements.
On-site freight and equipment loading spaces shall be provided for all commercial, office, and
industrial land uses.
The minimum numbers of loading spaces are shown in Table 24-97-1 (Required Loading Spaces).
24-97 PARKING AND LOADING
150
TABLE 24-97-1 REQUIRED LOADING SPACES
Land Use Total Gross Floor Area Required Loading Spaces
Office Less than 10,000 sq. ft. n/a
Equal to or greater than 10,000 sq. ft. 1
Commercial
Less than 10,000 sq. ft. n/a
10,000 sq. ft. to 30,000 sq. ft. 1
30,000 sq. ft. to 50,000 sq. ft. 2
50,000 sq. ft. to 75,000 sq. ft. 3
More than 75,000 sq. ft. 4
Industrial Less than 20,000 sq. ft. 1
More than 20,000 sq. ft. 2
Industrial developments with two or more dock-high loading spaces shall provide one trailer
parking/waiting space, 12 feet wide by 45 feet long minimum, for each two loading spaces.
B. Dimensions.
Each loading space shall have minimum dimensions of 12 feet wide, 40 feet long and 14 feet in
vertical clearance.
Deviations from the minimum maneuvering standards may be approved by the Zoning
Administrator if the spatial needs are less than the minimum required due to the truck size and
type that will be utilized in the operation of a specific business.
C. Location.
Loading areas shall be designed to ensure that loading and unloading takes place on-site and in no
case within adjacent public rights-of way.
Loading and maneuvering areas shall not encroach into required employee or visitor parking areas
or other areas on-site required for vehicle circulation.
Loading and maneuvering areas shall not encroach into required front yard setback.
Where loading docks or doors face a private street or main drive aisle serving three or more units,
loading doors and openings shall be positioned such that they do not face the private street or
drive aisle.
D. Striping and Identification. Loading areas shall be striped and clearly identified as for loading
purposes only.
E. Wheel Stops and Curbs. Loading areas contiguous with planter areas shall have a 6-inch raised curb
separation.