Loading...
HomeMy WebLinkAboutUP22-0004_B22-3582 PLAN SETCONSULTANTS REVISED BY:CHK'D BY: RWBG-001DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellCOVER1 0F 21 SHEETS 75 LOS VERJELES RD L O S V E R J E L E S R D O R O B A N G O R HW Y LA PORTE RDN4 A-501 1 PROJECT TEAMPROJECT DATA VICINITY MAP STRUCTURAL DESIGN:DESIGNER: BUILDER: A PROPOSED NEW RESIDENCE FOR MARK STEPHANS OWNER: A NOTE NUMBER LOCATE NOTE IN GENERAL NOTES ON THAT PAGE WALL LINE NUMBER OR LETTER REFRENCES WALL LINES IN STRUCTURAL CALCULATIONS STANDARD ABBREVIATIONS AB ANCHOR BOLT APA AMERICAN PLYWOOD ASSOCIATION ALT ALTERNATE ASTM AMERICAN SOCIETY for TESTING MATERIALS BRG BEARING C CHANNEL CBC CALIFORNIA BUILDING CODE CL CENTER LINE CLR CLEAR COL COLUMN CONC CONCRETE CONT CONTINUOUS DBL DOUBLE DIA DIAMETER DF DOUGLAS FIR DWL DOWEL DWG DRAWING (E) EXISTING EA EACH EF EDGE OF FACE EOS EDGE OF SLAB ELEV ELEVATION EN EDGE NAILING EQ EQUAL EW EACH WAY FF FINISHED FLOOR FLR FLOOR FT FOOT / FEET FTG FOOTING GA GAGE GLB GLU-LAMINATED BEAM HGR HANGER HOR HORIZONTAL ICC INTERNATIONAL CODE COUNCIL ICF INSULATING CONCRETE FORM IN INCH INFO INFORMATION K KIP (1,000 lbs) LB POUND LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER MFR MANUFACTURER MAX MAXIMUM MECH MECHANICAL MIN MINIMUM MISC MISCELLANEOUS NTS NOT TO SCALE OC ON CENTER OCEW ON CENTER EACH WAY OPP OPPOSITE PL PLATE PLF POUNDS PER LINEAR FOOT PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED REQ'D REQUIRED SIM SIMILAR SPEC SPECIFICATION STAGG STAGGERED STD STANDARD T & B TOP AND BOTTOM T & G TOUNGE AND GROOVE TYP TYPICAL UBC UNIFORM BUILDING CODE UNO UNLESS OTHERWISE NOTED VERT VERTICAL W/ WITH W/O WITHOUT WT WEIGHT LINTEL NUMBER REFRENCES TO LINTEL SCHEDULE ON THAT PAGE DETAIL INDICATOR TOP NUMBER= DETAIL NUMBER(S) BOTTOM NUMBER= DRAWING PAGE NUMBER MARANATHA FELLOWSHIP 75 LOS VERJELES ROAD BANGOR, CA MARANATHA FELLOWSHIP 75 LOS VERJELES ROAD BANGOR, CA A PROPOSED ADDITION FOR: INDEX TO DRAWINGS APPLIED ENGINEERING CONSULTANTS, INC 10360 CAREY DRIVE GRASS VALLEY, CA 95945 530-838-5358 roy.arashi@appliedec.com 1. THE INTENT OF THESE DRAWINGS IS TO SHOW ALL NECESSARY ITEMS TO COMPLETE THIS STRUCTURE. TYPICAL DETAILS AND NOTES WITHIN THESE DRAWINGS APPLY TO SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. ALL WORK AND CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES, REGULATIONS, AND SAFETY REQUIREMENTS. FOR ITEMS, METHODS, AND/ OR MATERIALS NOT SHOWN, THE MINIMUM REQUIREMENTS OF THE CURRENT (2016) CALIFORNIA BUILDING CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA ELECTRICAL CODE, 2016 CRC, CGBSC AND ENERGY CODE, ASCE7-10, ACI318-11, 2012 NDS AND ALL OTHER LOCAL STATE AND MUNICIPAL CODES AND ORDINANCES SHALL GOVERN. 2. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY REGULATIONS. 3. THE CONTRACTOR SHALL HOLD HARMLESS, INDEMNIFY AND DEFEND THE OWNER, DESIGNER, ENGINEER, AND HIS CONSULTANTS, AND EACH OF THEIR OFFICERS AND EMPLOYEES FROM ALL LIABILITY CLAIMS, LOSSES, OR DAMAGES ARISING OR SAID TO ARISE FROM THE PERFORMANCE OF WORK DESCRIBED HERIN. 4. WHILE EVERY ATTEMPT HAS BEEN MADE TO AVOID MISTAKES IN THE PREPARATION OF THESE PLANS, THE MAKER CANNOT GURANTEE AGAINST HUMAN ERROR, THEREFORE, THE DIMENSIONS AND SPECIFICATIONS OF THESE PLANS SHALL BE VERIFIED BY THE OWNER/ CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, AND ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF RANDY W. BUNNELL. 5. THESE PLANS HAVE BEEN DRAWN TO COMPLY WITH THE CLIENTS SPECIFICATIONS, AND ANY CHANGES MADE TO THEM AFTER PRINTS ARE MADE SHALL BE DONE AT THE CLIENTS EXPENSE. 6. ALL WORK SHALL BE THE BEST OF THEIR RESPECTIVE TYPES, AND CONTRACTORS SHALL BE RESPONSIBLE FOR OBSERVANCE OF ALL STATE, COUNTY, AND LOCAL BUILDING CODES. 7. FIRE, VANDALISM, AND THEFT INSURANCE ARE TO BE PROVIDED BY OWNER. PUBLIC LIABILITY AND WORKER'S COMPENSATION INSURANCE, IF APPLICABLE, ARE TO BE PROVIDED BY CONTRACTOR. 8. THE JOB SHALL BE LEFT BROOM CLEAN, WITH WINDOWS AND FIXTURES WASHED, AND ALL DEBRIS REMOVED BY CONTRACTOR. 9. THE CONTRACTOR SHALL GIVE THE DESIGNER 48 HOURS NOTICE MINIMUM WHEN SITE OBSERVATIONS ARE NECESSARY. 10. ANY AND ALL SURVEY AND SITE ENGINEERING WORK REQUIRED IN CONNECTION WITH THIS PROJECT SHALL BE BY SEPERATE CONTRACT BETWEEN OWNER / CONTRACTOR AND SURVEYOR OR ENGINEER OF CHOICE. 11. WHEN DISCREPANCIES ARISE BETWEEN ENGINEERING SPECIFICATIONS AND ARCHITECTURAL SPECIFICATIONS, THE ENGINEERS SPECIFICATIONS SHALL GOVERN. 12. THESE PLANS, SPECIFICATIONS, DETAILS, AND DESIGNS ARE THE SOLE PROPERTY OF RANDY W. BUNNELL CO. CONSTRUCTION IS LIMITED TO A ONE TIME USE ON THE PROPERTY NAMED HEREIN. THESE PAGES MAY NOT BE DISPLAYED, COPIED, OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF RANDY W. BUNNELL CO. PROJECT NOTES SUPPORTING DOCUMENTATION: ENGINEERING CALCS TESTING AND INSPECTIONS: 1. ICF WALLS: SPECIAL INSPECTION IS REQUIRED FOR REBAR PLACEMENT AND CONCRETE PLACEMENT IN THE ICF WALLS. 2. CONCRETE FOUNDATION: NO TESTING SHALL BE REQUIRED FOR THE CONCRETE FOUNDATION OR SLAB ON GRADE. 3. CONCRETE TESTING IS REQUIRED FOR ALL CONCRETE WITH fc'>2500 PSI, 4. ALL SIMPSON WEDGE ANCHORS OR TITEN BOLTS (EXCEPT INTERIOR 2 X 4 WALLS) OR EPOXY SET ANCHORS REQUIRE PERIODIC SPECIAL INSPECTION. TITEN BOLTS IN INTERIOR 2 X 4 SILL PLATES DO NOT REQUIRE SPECIAL INSPECTION. 5. INSTALLATION OF HIGH STRENGTH BOLTS (A325 AND A490) REQUIRE CONTINUOUS SPECIAL INSPECTION, 6. FIELD AND SHOP WELDING REQUIRES PERIODIC SPECIAL INSPECTION UNLESS WELDS ARE PERFORMED IN AN ICC CERTIFIED SHOP. 7. PUDDLE WELDS AT ASC DECK TO LEDGER AND BEAM REQUIRE SPECIAL INSPECTION. BUILDING OCCUPANCY AND TYPE ASSEMBELY GROUP A3 OCCUPANCY TYPE III CONSTRUCTION SQUARE FOOTAGES TOTAL SF NEW FIRST FLOOR 7,000 TOTAL SF NEW SECOND FLOOR 2,028 TOTAL SF ASSEMBLY AREA 9,028 COVERED PORCHES 1,055 DEFERRED SUBMITTALS: TRUSS CALCS: THIS STRUCTURE USES MANUFACTURED TRUSSES FOR THE ROOF FRAMING SYSTEM. TRUSS CALCS (DESIGN) ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. ANY EXCEPTIONS MUST BE ADDRESSED BEFORE SUBMITTING TO THE BUILDING DEPARTMENT. FIRE SPRINKLERS: THIS STRUCTURE DOES NOT REQUIRE FIRE SPRINKLERS. NOTES: 1. DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL BEFOR INSTALLATION BEGINS. THE BUILDER OR OWNER SHALLBE RESPONSIBLE FOR COORDINATION OF THE SUBMITTAL ITEMS AND ALLOW ADEQUATE REVIEW TIME BY THE BUILDING DEPARTMENT. 2. PRIOR TO BUILDING PERMIT FINAL APPROVAL, THE PROPERTY SHALL BE IN COMPLIANCE WITH THE VEGETATION CLEARANCE REQUIREMENTS PRESCRIBED IN THE CALIFORNIA FIRE CODE SECTION 4906, CALIFORNIA PUBLIC RESOURCES CODE 4291, AND CALIFORNIA GOVERMENT CODE 51182. CRC R337.1.5. 3. HERS VERIFICATION IS REQUIRED BY T-24 ENERGY REPORT. PROVIDE EVIDENCE OF THIRD PARTY VERIFICATION (HERS) TO PROJECT BUILDING INSPECTOR PRIOR TO FINAL INSPECTION. RANDY W. BUNNELL CO 14314 WRANGELL CT. PENN VALLEY, CA 95946 530-277-4474 SCL 330645 randy@bunnellco.com DESIGN CRITERIA: WIND SPEED= 94 MPH EXPOSURE C SEISMIC: CATEGORY D, SDS=0.537, R=4 BEARING PRESSURE= 1500 PSF G-001 PROJECT INFORMATION G-002 GEN NOTES G-003 CAL GREEN MANDATORY MEASURES A-101 FIRST FLOOR PLAN A-102 SECOND FLOOR PLAN A-201 ELEVATIONS A-301 SECTIONS S-401 FOUNDATION PLAN S-402 2ND FLOOR FRAME PLAN S-403 ROOF FRAMING PLAN S-501 STRUCTURAL NOTES S-502 STRUCTURAL DETAILS- ICF S-503 STRUCTURAL DETAILS- STRUCTURAL STEEL M-601 PLUMBING PLAN M-602 ELECTRICAL PLAN M-2.1 MECHANICAL PLAN LOWER FLOOR M-2.1 MECHANICAL PLAN UPPER FLOOR T-24.1 TITLE 24 T-24.2 TITLE 24 T-24.3 TITLE 24 P-701 SITE PLAN A TESTING, DEFERED SUBMITTALS, DESIGN CRITERIA LOADS: ROOF DL= 10.4 PSF Lr= 20 PSF FLOOR DL= 15 PSF Lf= 40 PSF GROUND SNOW LOAD= 0 PSF SOMMERS CONSTRUCTION PO BOX 455 BANGOR, CA 95946 530-624-2874 SCL 857563 sommersconstruction@iCloud.com 10/26/2022, 8:45:27 AM Engineer's seal on this and subsequent pages covers structural design only. CONSULTANTS REVISED BY:CHK'D BY: RWBG-002DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellGENERAL NOTES2 0F 21 SHEETS RESIDENTIAL STANDARD PLAN NOTES BMP STANDARD DETAILS FORM NO DBP-26CURRENT CODES 2019 Calif. Residential Code 2019 Calif. Building Code. (Structural only) 2019 Calif. Mechanical Code. 2019 Calif. Plumbing Code. 2019 Calif. Electrical Code. 2019 California Energy Code. (2016 Building Energy Efficiency Standards) 2019 California Green Building Standards Code. SNOW LOADS Elevation (Feet) Ground Snow 0-1499 No Requirement 1500-1999 20 psf 2000-2499 37 psf 2500-2999 55 psf 3000-3499 75 psf 3500-3999 122 psf4000-4499 149 psf 5000-5499 180 psf 5500-6000 215 psf Snow load values on this chart may be interpolated. Elevations may be determined from Google Earth, USGS Topo Maps, or other sources. Structures proposed in areas where snow loads exceed 50 psf, require design by a Registered Design Professional. Approximate elevations for some Butte County locations: Berry Creek 2200’ Concow 2200’ Forest Ranch 2400’ Butte Meadows 4500’ De Sabla 2720’ Magalia 2400’ Clipper Mills 3600’ Feather Falls 3000’ Stirling City 3600’ Cohasset 3200’ Forbestown 2800’ Yankee Hill 2200’ For manufactured Homes, see T25 Table 1338-1 Region III GENERAL 1.Provide each bedroom, basement, and habitable attics with a minimum of one exterior window with a 44” maximum clear opening height, 5.7 sq. ft. minimum clear openable area (minimum 5.0 sq. ft. at grade floor openings), 24” minimum clear openable height and 20” minimum clear width, or an openable exterior exit door. (CRC R310.2.1 and CRC R310.2.2) Window wells, ladders, and steps shall comply with CRC R310.2.3. Bars, grilles, covers, ands screens shall be releasable or removable from the inside without the use of a key, tool, special knowledge, or force greater than 15lbs to operate the emergency escape and rescue openings. (CRC R310.4) Photovoltaic panels & modules shall not be below an emergency escape and rescue opening within 36”. (CRC 324.6.2.2) 2.Each bathroom containing a bathtub, shower or tub/shower combination shall be mechanically ventilated with Energy Star approved equipment (minimum 50cfm) with an integral humidistat installed. (CRC R303.3.1) 3.Provide attic cross ventilation: 1/150 of attic area or 1/300 with at least 40% but not more than 50% of vents are a maximum 3 ft. below the ridge or highest space in the attic and the balance is provided in the lower third of the attic space (not limited to eaves or cornice vents). As an alternative in Climate Zone 16, the net area may be reduced to 1/300 when a Class I or II vapor barrier is in- stalled on the warm-in-winter side of the ceiling. Baffles are required at vents for insulation. Provide minimum of 1” inch of air space between insulation and roof sheathing. (CRC R806) 4.Enclosed rafter spaces shall have a 1-inch clear cross ventilation. (Properly sized rafters for insulation) (CRC R806.3) 5.Under floor cross ventilation: minimum 1/150 of under floor area. When a class 1 vapor retarder is installed on the ground surface, the minimum area of ventilation may be limited to 1/1500 of under-floor space. One ventilation opening shall be within three (3) feet of each corner of the building (CRC R408.1). Unvented crawl spaces shall comply with CRC R408.3. 6.Exterior balconies and elevated walking surfaces exposed to water, where structural framing is protected by an impervious moisture barrier require construction documents with manufacturer’s installation instructions (CRC 106.1.5). Must be inspected and approved before concealing barrier. (CRC 109.1.5.3) 7.Enclosed framing in exterior balconies and elevated walking surfaces ex- posed to rain, snow or drainage from irrigation shall be provided with cross- ventilation area of at least 1/150. (CRC 317.1.6) 8.Provide landings and a porch light at all exterior doors. Landings are to be minimum 3 ft deep x width of door. Landings at required egress doors may step down a maximum of 7.75 inches when the door does not swing over the landing and 1.5 inches when door swings onto the landing. Other than required exterior exit doors may have a threshold of 7.75 inches maximum; a landing is not required if a stair with two or fewer risers is located on the exterior side and the door does not swing over the stairway. (CRC R311.3-R311.3.2) 9.Mezzanines shall not be greater than 1/3 of the story unless fire sprinklers are installed then the area can be ½ of the story. (CRC 325.3) 10.The following windows shall be fully tempered: (CRC R308.4) Sliding/swinging glass doors Glazing in walls and enclosures facing hot tubs, spas, whirlpools, saunas, steam rooms, bathtubs, showers and swimming pools where the glazing is less than 60 inches above the standing surface within the compartment and within 60 inches horizon- tally of the water’s edge (CRC R308.4.5) Glazing within a 24” arc of a door that is less than 60 inches above the floor. Safety glazing required on a wall less than 180 degrees from the plane of the door in a closed position and within 24” of hinge side of an in-swing door. (R308.4.2) Glazing where the exposed area is greater than 9sq.ft, bottom is less than 18 in. and at least 36 in. above the floor, and adjacent to a walking surface Within 60in. of the bottom tread of a stairway and less than 36in. above the landing Glazing in guards and railings Glazing adjacent to stairways, landings, and ramps within 36in. horizontally of the walking surface less than 36in. above the walking surface 11.Provide fall protection in accordance with C.R.C. Section R312.2.1 for the operable windows with sills located less than 24 inches above finished floor and greater than 72 inches above the finished grade, or surface on the outside of the building. C.R.C. Section R312.2 FOUNDATIONS & CONCRETE SLABS 1.Slope drainage 6” within the first 10ft. from the foundation wall. If physical obstructions or lot lines prohibit the 10ft distance, a 2-5 percent slope shall be provided to an approved alternative method of diverting the water away from the foundation. Impervious surfaces shall also be sloped a minimum of 2 percent for 10ft away from structures to an approved drainage way. (CRC R401.3) 2.Stepped footings shall be used when slope of footing bottom is greater than 1 in 10 (V:H). Step footing detail shall be shown on building elevations and foundation plan. (CRC R403.1.5) 3.Concrete slabs: 3 ½” minimum (CRC R506.1). Slabs shall have a 4” thickness of 3/8” minimum gravel under the concrete slab. Separate from soil with a 6-mil polyethylene vapor retarder with joints lapped not less than 6 inches. A capillary break shall be installed when a vapor retarder is required per CGBC Section 4.505. 4.Provide an 18” x 24” under-floor access, unobstructed by pipes or ducts and within 5’ of each under-floor plumbing cleanout and not located under a door to the residence, is required. Provide a solid cover or screen. (CRC 408.4 & CPC 707.9) 5.Minimum sill bolting: ½” anchor bolts or approved anchors at 6 ft. o.c. maximum for one-story. (CRC R403.1.6) Use anchor bolts at 4 ft. o.c. maximum for three story construction. Embed bolts 7” minimum. The anchor bolts shall be placed in the middle third of the width of the plate. Locate end bolts not less than 7 bolt diameters, nor more than 12” from ends of sill members. In SDC D0 and above: Provide 3”X3”X0.229 plate washers on each bolt at braced or shear wall locations, standard cut washers shall be permitted for anchor bolts not located in braced/shear wall lines. (CRC R403.1.6.1 & R602.11.1) CLEARANCES AND TREATMENT FOR WOOD FRAMING 1.Weather exposed glued-lam, beams and posts shall be pressure treated or shall be wood of natural resistance to decay (CRC R317.1.3 & 5) 2.Columns exposed to the weather or in basements, when supported on concrete pier or metal pedestals shall be pressure treated or natural resistance to decay unless the pier/pedestals project 1” above concrete or 6” above earth and the earth is covered by an approved impervious moisture barrier. (CRC R317.1.4 exc. 1) 3.Columns in enclosed crawl spaces or unexcavated areas located within the periphery of the building shall be pressure treated or natural resistance to decay unless the column is supported by a concrete pier or metal pedestal of a height 8” or more, and the earth is covered by an impervious moisture barrier. (CRC R317.1.4 exc. 2) 4.Deck posts supported by concrete piers or metal pedestals shall be pressure treated or wood of natural resistance to decay unless projecting not less than 1” above a concrete floor or 6” above exposed earth. (CRC R317.1.4 exc. 3) 5.Wood joist shall be provided with 18” clearance to earth and girders 12” to earth, or shall be pressure treated or natural resistance to decay when located within the periphery of the building foundation. (CRC R317.1 (1)) FLOORS 1.Underfloor areas with storage, fuel-fired equipment or electric-powered equipment with less than 2x10 solid joists shall be protected on the underside by half-inch sheet- rock or a sprinkler system. (R302.13) 2.Balconies must be designed for a minimum live load of 60lbs per square foot. (CRC Table-R301.5) WALLS 1.Positive connection shall be provided to ensure against uplift and lateral displacement. (CRC R502.9 & CBC 2304.10.7) 2.All fasteners used for attachment of siding & into pressure treated lumber shall be of a corrosion resistant type. (CRC R317.3) 3.Fire-block in concealed spaces of stud walls/partitions, vertically at ceiling/floor levels, & horizontally at 10ft. intervals. Fire-block at soffits, drop ceilings/similar locations & in concealed spaces at the top/bottom of stair stringers. (CRC R302.11) 4.Provide approved building paper under the building siding and approved flashing at exterior openings. (CRC R703.2) Specify a minimum of 2 layers of Grade D paper under stucco and 2 layers of 15lb felt (or equivalent) under stone veneer. 5.Stucco shall be not less than three coat where applied over metal lath or wire fabric lath, and shall have a minimum clearance to earth of 4 inches and 2 inches to paved surfaces with an approved weep screed. (CRC R703.7.2.1) Masonry stone veneer shall be flashed beneath the first course of masonry and provided with weep holes immediately above the flashing. (CRC R703.8.5 and R703.8.6) ROOF 1.Roof sheathing can only cantilever 9 inches beyond a gable end wall unless supported by overhang framing. (CRC 802.5.2.1) 2.Provide a minimum 22” x 30” access opening to attic (CRC R807); may be required to be 30”x30” to remove the largest piece of mechanical equipment per the CMC. 3.Roof drains/gutters required to be installed per the CPC with leaf/ debris protection also installed. (CRC R337) 4.Roof construction and coverings shall comply with CRC Chapters 8, 9 and local ordinance. All roofing shall be tested/listed Class A minimum. 5.Asphalt shingles with sloped roofs 2/12 to <4/12 shall have two layers of underlayment applied per CRC R905.2.2. GARAGE AND CARPORT 1.Garage shall be separated from the dwelling unit & attic area by ½” gypsum board applied to the garage side. Garage beneath habitable rooms shall be separated by not less than 5/8” type X gypsum board. Structure supporting floor/ceiling assemblies used for required separations shall have ½” gypsum board installed minimum. Door openings from the garage to the dwelling shall be solid wood/steel doors or honeycomb steel doors not less than 1 3/8” thick or a 20-minute rated fire door. Doors shall be self-closing & self-latching. No openings directly into a sleeping room from the garage. When the dwelling and garage have fire sprinklers installed per R309.6 and R313, doors into the dwelling unit from the garage only need to be self-closing and self-latching. (CRC R302.5.1 & T-R302.6) 2.Ducts penetrating the garage to dwelling separation shall be a minimum of 26 gauge with no openings into the garage. (CRC R302.5.2) 3.Penetrations through the garage to dwelling separation wall (other than ducts as listed above) shall be fire-blocked per CRC section R302.11, item #4. 4.Garage and carport floor surfaces shall be non-combustible material and slope to drain towards the garage door opening. (CRC R309.1) 5.Appliances and receptacles installed in garage generating a glow, spark or flame shall be located 18” above floor unless it is listed as flammable vapor ignition resistant. (CMC 305.1) Provide protective post or other impact barrier from vehicles. (CMC 305.1.1) STAIRWAYS & RAMPS 1.Stair landings required every 12’7” of vertical rise. (CRC R311.7.3) 2.Exterior stair stringers must be naturally resistant to decay or pressure treated. (CRC R317.1) 3.Rise shall be maximum 7.75”; Run shall be 10” minimum; headroom 6’-8” minimum; width 36” minimum, 31.5” between a handrail on one side and 27” with handrails on two sides. Variation between riser heights 3/8” maximum. A nosing not less than .75 inches but not more than 1.25 inches shall be provided on stairways with solid risers where the tread depth is less than 11 inches. The leading edge of treads shall project not more than 1.25 inches beyond the tread below. Open risers are permitted, provided the opening between the treads does not permit the passage of a 4” sphere. (Openings are not limited when the stair has a rise of 30” or less). (CRC R311.7 & R312) 4.Stairways with 4 or more risers shall have a handrail on one side 34” to 38” above the tread nosing. Circular handrails shall have an outside diameter of 1.25”-2”; if not circular, it shall have a perimeter dimension of 4”-6.25” with a maximum cross-sectional dimension of 2.25”. See R311.7.8.3 item# 2 for type II handrails with a parameter over 6.25”. A minimum clearance of 1.5” shall be maintained from the wall or other surface. Handrails shall be returned, terminate in newel posts, or safety terminals. (CRC R311.7.8.2) 5.Guards shall be 42” minimum height (unless acting as a handrail/guard for a stairway; the guard height may be 34”-38” in height), with openings less than 4” inches clear (guards on the open sides of stairs may have 4 3/8” openings). (CRC R312) 6.Provide landings at the top/bottom of the stairway the width of the stairway. The depth of the landing shall be 36” minimum. (see CRC R311.7.6 for exceptions). 7.Usable spaces underneath enclosed/unenclosed stairways shall be protected by a minimum of ½” gypsum board. (CRC R302.7) 8.Ramps serving the egress door shall have a slope of not more than 1 unit vertical in 12 units horizontal (8.3-percent slope). All other ramps shall have a maximum slope of 1 unit vertical in 8 units horizontal (12.5-percent slope). Exception: Where it is technically infeasible to comply because of site constraints, ramps shall have a slope of not more than 1 unit vertical in 8 units horizontal (12.5-percent slope) (CRC R311.8.1). Provide 3’X3’ landings at the top and bottom of ramps, where doors open onto ramps, and where ramps change directions. (CRC R311.8.2) DECKS 1.Guards are required if deck or floor is over 30” above grade within 36” of the deck or floor, minimum 42” high, with openings less than 4” (CRC R312). Guardrails shall be designed and detailed for lateral forces according to CRC Table 301.5. 2.Provide deck lateral load connections at each end of the deck and at deck intersections per CRC R507.9.2. Specify connectors with a minimum allowable stress design capacity of 1,500lbs and install with 24” of the end of the deck. 750lb rated devices are allowed (DTT1Z as example) if located at 4 points along the deck. 3.Posts/columns shall be retrained at the bottom end to prevent lateral displacement; clearly show approved post bases, straps, etc. to achieve this per CRC R407.3. 4.Joists, girders, structural blocking and support posts shall be wood of natural resistance to decay or pressure-treated lumber when exposed to the weather. (CRC R317.1.3) ELECTRICAL 1.No electrical panels in closets or bathrooms. Maintain a clearance of 36” inches in front of panels, 30” wide or width of equipment and 6’-6” high for headroom. (CEC 110.26) 2.Provide a minimum 3 lug intersystem bonding bus bar at the main electrical service. (CEC 250.94) 3.All automatic garage door openers that are installed in a residence shall have a battery backup function that is designed to operate when activated because of an electrical outage. (SB-969) 4.A concrete-encased electrode (ufer) consisting of 20’ of rebar or #4 copper wire placed in the bottom of a footing is required for all new construction. (CEC 250.52(A) (3)) Bond all metal gas and water pipes to ground. All ground clamps shall be accessible and of an approved type. (CEC 250.104) 5.All 15/20 ampere receptacles installed per CEC 210.52 shall be listed tamper-resistant receptacles. (CEC 406.12) 6.All branch circuits supplying 15/20 ampere outlets in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, kitchens, laundry room or similar rooms/areas shall be protected by a listed combination type arc-fault circuit interrupter. (CEC 210.12) 7.Provide a minimum of one 20A circuit to be used for the laundry receptacle. (CEC 210.11(C)(2)) Provide a minimum of one 20A circuit for bathroom receptacle outlets. (CEC 210.11(C)(3) 8.Provide at least 1 outlet in basements, garages, laundry rooms, decks, balconies, porches and within 3’ of the outside of each bathroom basin. (CEC 210.52 (D), (F) & (G)) 9.Furnaces installed in attics and crawl spaces shall have an access platform (catwalk in attics), light switch and receptacle in the space. Provide a service receptacle for the furnace. (CEC 210.63) 10.All dwellings must have one exterior outlet at the front and the back of the dwelling. (CEC 210.52(E)) 11.Garage receptacles shall not serve outlets outside the garage. Exception: Garage circuit may serve readily accessible outdoor receptacle outlets. ((CEC 210.11 (C)(4)) A minimum of 1 receptacle shall be provided for each car space. (210.52(G) (1)) 12.At least one wall switched lighting outlet or fixture shall be installed in every habitable room, bathroom, hallways, stairways, attached garages and detached garages with electrical power, equipment spaces (attics, basements, etc.). (CEC 210.70) 13.Kitchens, dining rooms, pantries, breakfast nooks, and similar areas must have a minimum of two 20A circuits. Kitchen, pantry, breakfast nooks, dining rooms, work surfaces and similar areas counter outlets must be installed in every counter space 12” inches or wider, not greater than 4’ o.c., within 24” inches of the end of any counter space and not higher than 20” above counter. (CEC 210.52 (C)) Island counter spaces shall have at least 1 receptacle outlet unless a range top or sink is installed than 2 receptacles may be required. 1 receptacle is required for peninsular counter spaces. Receptacles shall be located behind kitchen sinks if the counter area depth behind the sink is more than 12” for straight counters and 18” for corner installations. (CEC Figure 210.52(C)(1)) 14.The main service disconnect shall have a a rating of not less than 100 amps. C.E.C. Article 230.79(C). 15.Receptacles shall be installed at 12’ o.c. maximum in walls starting at 6’ maximum from the wall end. Walls longer than two feet shall have a receptacle. Hallway walls longer than 10 ft. shall have a receptacle in hallways. (CEC 210.52(A)) 16.Receptacles shall not be installed within or directly over a bathtub or shower stall. (CEC 406.9(C) Light pendants, ceiling fans, lighting tracks, etc. shall not be located within 3ft horizontally and 8ft vertically above a shower and/or bathtub threshold. (CEC 410.10(D)) 17.All lighting/fan fixtures located in wet or damp locations shall be rated for the application. (CEC 410.10) 18.GFCI outlets are required: for all kitchen receptacles that are designed to serve countertop surfaces, dishwashers, bathrooms, in under-floor spaces or below grade level, in unfinished basements, crawl space lighting outlets, in exterior outlets, within 6’ of a laundry/utility/wet bar sinks, laundry areas, and in all garage outlets including outlets dedicated to a single device or garage door opener. (CEC 210.8) 19.Carbon-monoxide alarms shall be installed in dwelling units with fuel-burning appliances or with attached garages (CRC R315): Outside of each separate sleeping area in the immediate vicinity of bedrooms On every level of a dwelling unit including basements 20.Smoke alarms shall be installed (CRC (R314): In each room used for sleeping purposes. Outside of each separate sleeping area in the immediate vicinity of bedrooms. In each story, including basements. At the top of stairways between habitable floors where an intervening door or obstruction prevents smoke from reaching the smoke detector. Shall not be installed within 20ft horizontally of cooking appliances and no closer than 3ft to mechanical registers, ceiling fans and bathroom doors with a bathtub or shower unless this would prevent placement of a smoke detector (314.3(4)). All smoke and carbon-monoxide alarms shall be hardwired with a battery backup (smoke alarms shall have a 10-year sealed battery). (CRC R314.4 & R315.1.2) Smoke detectors within 10 feet to 20 feet of the stove shall be ionization type with alarm silencing switch. CRC R314.3.3. 21.All 15/20 ampere receptacles in wet locations shall have in-use (bubble) covers installed. All receptacles in wet locations shall also be listed weather-resistant type. (CEC 406.9(B)(1)) PLUMBING 1.Underfloor cleanouts shall not be more than 5’ from an underfloor access, access door or trap door. (CPC 707.9) 2.ABS piping shall not be exposed to direct sunlight unless protected by water based synthetic latex paints. (CPC 312.13) 3.PVC piping shall not be exposed to direct sunlight unless protected by water based synthetic latex paint, .04” thick wrap or otherwise protected from UV degradation. (CPC 312.14)4.Underground water supply lines shall have a 14 awg blue tracer wire. (CPC 604.10.1) 5.The adjacent space next to showers without thresholds shall be considered a “wet location” when using the CRC, CBC, and the CEC. (CPC 408.5) 6.Shower compartments, regardless of shape, shall have a minimum finished interior of 1024 square inches (32” by 32”) and shall also be capable of encompassing a 30” circle. The required area and dimensions shall be measured at a height equal to the top of the threshold and shall be maintained to a point of not less than 70” above the shower drain outlet. (CPC 408.6) Provide curtain rod or door a minimum of 22” in width. (CPC 408.5) Showers and tubs with showers require a non- absorbent surface up to 6’ above the floor. (CRC R307.2) Minimum shower receptor slope is 1/8” per foot. (CPC 408.5) 7.Show location and size of the water heater on plans. Provide pressure relief valve with drain to outside for water heater. (CPC 504.6) Provide seismic strapping in the upper & lower third of the water heater a minimum of 4” above controls. (CPC 507.2) The water heater shall be of an instantaneous type or the following shall be provided (new construction only) (CEC 150(n)): A 120V receptacles provided within 3ft A category III or IV vent, or a straight (without bends) Type B vent Condensate drain that is no more than 2 inches higher than the base of the water heater Gas supply line with a minimum 200,000 Btu/hr dedicated capacity for the water heater A dedicated 120/240, 3 wire circuit with 10AWG wire to a receptacle out- let within 3’ of the water heater. The unused conductor shall be electrically isolated and have a reserved circuit breaker space. Both ends of the conductor shall be labeled “spare” and be electrically isolated. A reserve single-pole circuit breaker space near this circuit labeled “Future 240V Use.” (CEC 150.0(n)) 8.Domestic hot water lines shall be insulated. Insulation shall be the thickness of the pipe diameter up to 2” in size and minimum 2” thickness for pipes larger than 2” in diameter. (CPC 609.11) 9.Water heaters located in attics, ceiling assemblies and raised floor assemblies shall show a water-tight corrosion resistant minimum 1 ½” deep pan under the water heater with a minimum ¾ inch drain to the exterior of the building. (CPC 507.5) 10.Water closet shall be located in a space not less than 30” in width (15” on each side) and 24” minimum clearance in front. (CPC 402.5) 11.Indicate on the plans that the maximum hot water temperature discharging from a bathtub or whirlpool bathtub filler shall not exceed 120 degrees F. (CPC 408.3) 12.Provide anti-siphon valves on all hose bibs. (CPC 603.5.7) 13.Floor drains shall be provided with a trap primer. (CPC 1007) 14.Clearly label on the plans the maximum water flow rates per the (CGBSC 4.303.1): Water Closets: 1.28gpf Urinals: .125gpf Kitchen Faucets: 1.8gpm @ 60psi Lavatory Faucets: 1.2gpm @ 60psi Showerheads: 1.8gpm MECHANICAL 1.All newly installed gas fireplaces shall be direct vent and sealed-combustion type. (CMC 912.2) 2.Wood stove or pellet stove shall meet the U.S. EPA New Source Performance Standard emission limits or on the Butte County Air Quality Management District (BCAQMD) approved list and shall have a permanent label certifying emission limits. 3.Top chimney must extend a minimum of 2 ft. above any part of the building within 10 ft. (CMC 802.5.4) 4.Fireplaces shall have closable metal or glass doors, have combustion air intake drawn from the outside and have a readily accessible flue dampener control. Continuous burning pilot lights are prohibited. (CEC 150.0(e)) 5.Provide combustion air for all gas fired appliances per CMC Chapter 7. 6.Gas vents passing through an insulated assembly shall have a metal insulation shield a minimum 2” above insulation. (CMC 509.6.2.7) 7.Gas water heater and furnace are not allowed in areas opening into bathrooms, closets or bedrooms unless installed in a closet equipped with a listed gasketed door assembly and a listed self-closing device with all combustion air obtained from the outdoors. (CPC 504) 8.Rooftop equipment on roofs with over 4/12 slope shall have a level 30”x30” working platform. (CMC 304.2) 9.Exhaust openings terminating to the outdoors shall be covered with a corrosion resistant screen ¼”-1/2” in opening size (not required for clothes dryers). (CMC 502.1) 10.Vent dryer to outside of building (not to under-floor area). Vent length shall be 14 ft. maximum. Shall terminate a minimum of 3’ from the property line and any opening into the building. (CMC 504.4.2) 11.Environmental Air Ducts shall not terminate less than 3’ to a property line, 10’ to a forced air inlet, 3’ to openings into the building and shall not discharge on to a public way. (CMC 502.2.1) 12.Provide minimum 100 square inches make-up air for clothes dryers installed in closets. (CMC 504.4.1(1)) 13.Heating system is required to maintain 68 degrees at 3 ft. above floor level and 2ft from exterior walls in all habitable rooms. (CRC R303.10) TITLE 24 ENERGY 1. ALL luminaires must be high efficacy (150.0(k)1A) 2. Luminaries recessed in insulated ceilings must meet five requirements (150.0(k)1C): They must be rated for direct insulation contact (IC). They must be certified as airtight (AT) construction. They must have a sealed gasket or caulking between the housing and ceiling to prevent flow of heated or cooled air out of living areas and into the ceiling cavity. Hardwired ballasts or drivers, allow ballast or driver maintenance and replacement to be readily accessible from below the ceiling without requiring cutting holes in ceiling. They may not contain a screw base sockets 3. In bathrooms, garages, laundry rooms, and utility rooms, at least on luminaire in each of these spaces shall be controlled by a vacancy sensor or occupant sensor provided the occupant sensor is initially programmed like a vacancy sensor (manual-on operation). (150.0(k)2I) 4. Joint Appendix A (JA8) certified lamps shall be considered high efficacy. JA8 compliant light sources shall be controlled by a vacancy sensor or dimmer. (Exception:<70sf closets and hallway) (150.0(k)2K) 5. Under-cabinet lighting shall be switched separately from other lighting systems. (150.0(k)2L) 6.All exterior lighting shall be high efficacy, be controlled by a manual on/off switch and have one of the following controls (the manual switch shall not override the automatic control device): (150.0(k)3A) Photo-control and motion sensor Photo-control and automatic time switch control Astronomical time clock control turning lights off during the day 7.All high efficacy light fixtures shall be certified as “high-efficacy” light fixtures by the California Energy Commission. 8.Contractor shall provide the homeowner with a luminaire schedule giving the lamps used in the luminaires installed. (10-103(b)) 9.The number of blank electrical boxes more than 5 feet above the finished floor shall not be greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor, or fan speed control. (150(k)1B) 10.Provide a gasket/ insulation on all interior attic/under-floor accesses. (110.7) 11.Provide verification on the plans how the building will meet the minimum ventilation and acceptable indoor air quality requirements per ASHRAE Standard 62.2. Window operation is not a permissible method of providing the whole building ventilation airflow required. This is subject to HERS testing. The following label must be attached to the fan switch: “To maintain minimum levels of outside air ventilation required for good health, the fan control should be on at all times when the building is occupied, unless there is severe outdoor air contamination.” (California Energy Code 150.0(o)) A minimum 100 CFM indoor air quality fan is required in the kitchen and shall be HERS verified. WILDLAND URBAN INTERFACE (WUI) 1.Exterior wall coverings shall be noncombustible, ignition resistant, heavy timber, log wall or fire resistive construction. (CRC R337.7) 2.Exterior wall coverings shall extend from the foundation to the roof and terminate at 2 inch nominal solid blocking between rafters and overhangs. (CRC R337.7.3.2) 3.Open/enclosed roof eaves and soffits, exterior porch ceilings, floor projections, underfloor areas and undersides of appendages to comply with ignition resistant construction requirements. (CRC R337.5-9) 4.Spaces created between roof coverings and roof decking shall be fire stopped by approved materials or have one layer of minimum 72lb mineral surfaced non-perforated cap sheet complying with ASTM D 3909. (CRC R337.5.2) 5.Where valley flashing is installed, the flashing shall be not less than 26 awg and installed over not less than one layer of minimum 72lb mineral surfaced non-perforated cap sheet complying with ASTM D 3909 and at least 36 inches wide running the full length. (CRC R337.5.3) 6.Attic gable and eaves above 12ft and under-floor ventilation shall be provided with fully covered metal wire mesh, vents, or other materials that have a minimum 1/16 inch and maximum 1/8 inch openings, non-combustible and corrosion resistant. All other eave vents shall be listed/approved to resist the intrusion of flame and burning embers. (CRC R337.6) 7.Indicate on plans exterior glazing shall have a minimum of one-tempered pane, glass block, have a fire resistive rating of 20 minutes or be tested to meet performance requirements of SFM Standard 12-7A-2. (CRC R337.8.2) 8.Operable skylights shall be protected by a noncombustible mesh screen 1/8” max openings (R337.8.2.2) 9.Exterior doors including garage doors shall be noncombustible, ignition resistant material, minimum 1 3/8 inch solid core, minimum 20-minute fire resistive rating or shall be tested to meet the performance requirements of SFM Standard 12-7A-1. (CRC R337.8.3) 10.Garage door perimeter gap maximum 1/8”. Metal flashing, jamb and header overlap, and weather-stripping meeting section requirements are permitted. (R337.8.4) 11.The walking surface material of decks, porches, balconies and stairs within 10ft of the building shall be ignition resistant material, exterior fire-retardant treated wood or noncombustible material. (CRC R337.9) GREEN BUILDING 1. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site (CGBSC 4.106.2): Retention basins of sufficient size shall be utilized to retain storm water on site Where storm water is conveyed to a public drainage system, collection point, gutter, or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 2.All new residential construction with attached private garages shall have the following for electric vehicle (EV) charging stations (CGBSC 4.106.4): Install a minimum 1-inch conduit capable of supplying a 208/240V branch circuit to a suitable box location for EV charging. The other end shall terminate to the main service and/or subpanel. The main panel and/or subpanel shall be of sufficient size to install a 40-ampere dedicated branch circuit. The dedicated overcurrent protection space shall be labeled “EV CAPABLE”. 3.Multiple shower heads serving a single shower shall have a combined flow rate of 1.8 gpm or the shower shall be designed to allow only one shower outlet to be in operation at a time. (CGBSC 4.303.1.3.2) 4.A minimum of 65% of nonhazardous construction and demolition waste shall be reused or recycled. CGBC Section 4.408.1. 5.At time of final inspection, a building operation and maintenance manual, compact disc, etc. shall be provided containing the following: (CGBSC 4.410) Directions that manual shall remain onsite for the life of the building Operation and maintenance instructions for equipment, appliances, roof/yard drain- age, irrigation systems, etc. Information from local utility, water and waste recovery providers Public transportation and carpool options Material regarding importance of keeping humidity levels between 30-60 percent Information regarding routine maintenance procedures State solar energy incentive program information A copy of any required special inspection verifications that were required (if any) 6.The project shall meet minimum pollutant control requirements for adhesives, sealants, caulks, paints, carpet, resilient flooring systems, etc. (CGBSC 4.504) 7.Duct openings related to HVAC systems shall be covered with tape, plastic, sheet metal or other methods to reduce the amount of water, dust and debris which may enter the system. (CGBSC 4.504.1) 8.Provide a bathroom fan complying with the requirements of CGBC Section 4.506. Please add this note to the plans: The bathroom exhaust fan shall be controlled with humidistat control capable of adjustment between a relative humidity range of 50% to 80%, and shall be ENERGY STAR compliant. 2019 GENERAL NOTES SHEET The general notes sheet is based on the 2019 California Building Standard Codes. This is not an all-inclusive list of code requirements specific to the project. Reference applicable sheets and specific areas of the plans for locations of fixtures/equipment, structural components, structural design criteria, building finishes and other components specific to the project construction. GENERAL NOTES 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBG-003DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellCAL GREENMANDATORYMEASURES3 0F 21 SHEETS 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBA-101DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy Bunnell1ST FLOOR PLAN4 0F 21 SHEETS A B C D (1) - #5 (1) - #5 (1) - #4 (1) - #4 #3 SINGLE LEG @ 12" O.C. MIN LINTEL HEIGHT 24" AMVIC 6" LINTEL SCHEDULE LINTEL #BOTTOM STEEL TOP STEEL STIRRUPS 12" (1) - #4 18"(1) - #5 #3 SINGLE LEG @ 6" O.C. FIRST 24" FROM SUPPORT THEN 12" O.C. (1) - #4 TO TOP OF WALL(1) - #5 STD #4 VERTS @ 12" O.C. #3 SINGLE LEG @ 12" O.C. 5-0x5-04-0x3-0 5-0x5-0 3-0x6-8 3-0x6-8 5-0x5-05-0x5-05-0x5-05-0x5-03-0x6-83-0x4-63-0x4-6 3-0x4-6 6-0x6-86-0x6-810-0x7-06-0x6-816-0x5-0 3-0x6-84-0x6-8 4-0x6-8 3-0x6-8 3-0x6-8 3-0x4-63-0x4-64-0x4-6 4-0x4-6 4-0x4-6 3-0x6-8 3-0x6-83-0x6-8 10-0x7-03-0x4-63-0x4-6 3-0x4-6 5-0x6-8 3-0x6-8 3-0x6-8 3-0x6-83-0x6-83-0x6-8 3-0x6-8 4-0x4-6 4-0x6-8 3-0x6-8 4-0x6-8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 123456789101112131415161718123456789101112131415161718RG FFDW DW 70'-0" 13'-0"31'-0"25'-11" 16'-5"18'-7"11'-7"6'-8"11'-0"5'-9"100'-0"8'-9"79'-4"20'-8"25'-6"16'-4"16'-4"13'-10"17'-4"10'-7"70'-0" 17'-11"17'-1"20'-1"8'-6"6'-5"23'-4"8'-3"14'-0"23'-4"14'-7"16'-7"12'-1" 8'-0" 27'-0"20'-1"28'-1"23'-11"52'-0"31'-2"12'-0"10'-0"6'-0"17'-4"16'-4"16'-4"16'-4"16'-4"17'-4"<MARKERDRAWINGNUMBER_R><MARKERSHEETNUMBER_R> (E) ELECTRICPANEL (N) WINDOW (N) SLIDING FIRE AND SMOKERATED DOOR(LAWRENCE DOORS OR EQUAL) WALLS OF FORMER CLASSROOM 1TO BE REMOVED D D D D C C D D D D D DDDD A ALL INTERIOR WALLS TO BE 2 X 4 DF #2 STUDS @ 16" O.C.W/ DBL 2 X 4 TOP PLATES & 2 X 4 PTDF SILL PLATE.ATTACH SILL PLATE TO SLAB W/ 1/2" ø GALV. TITEN BOLTS@ 48" O.C. W/ 2 1/2" MIN EMBED. ALL INTERIOR WALLS TO BE 2 X 4 DF #2 STUDS @ 16" O.C.W/ DBL 2 X 4 TOP PLATES & 2 X 4 PTDF SILL PLATE.ATTACH SILL PLATE TO SLAB W/ 1/2" ø GALV. TITEN BOLTS@ 48" O.C. W/ 2 1/2" MIN EMBED. 1 1 1 1 AMVIC 6" CORE (11" OVERALL) ICF WALLW/ #4 REBAR @ 12" O.C. VERTICALLY& 18" O.C. HORIZONTALLY(TYP ALL NEW EXTERIOR WALLS) AMVIC 6" CORE (11" OVERALL) ICF WALLW/ #4 REBAR @ 12" O.C. VERTICALLY& 18" O.C. HORIZONTALLY(TYP ALL NEW EXTERIOR WALLS) 4 X 4 DF #2 POSTW/ PCZ4 POST CAP& ABU44Z BASE MOUNTEDTO CONCRETE W/ 1/2" ø X 4" TITEN BOLT S-502 5 S-502 1,2,3 S-502 10 S-502 10 S-502 10 S-502 10 S-502 6,7,8 S-401 3 S-503 1 18" SQUARE CONCRETE COLUMN @ROOF BEAM FRAME LINES.RUN HORIZONTAL WALL REBARCONTINUOUS THROUGH COLUMNS. (E) STUDY CLASSROOM 1(FORMER NURSERY) (E) WOMEN (E) MENNURSERY (FORMER ENTRY) (E) SOUND ROOM/STORAGE ENTRY (FORMER STORAGE) SEWING STORAGE (E) AUDITORIUM (N) WOMEN (N) MEN (N) STORAGE (N) KITCHENETTE (N) CLASSROOM (N) GYM 3.5" X 16" PSL 2.2E HEADERW/ 2- 2 X 4 TRIMMERS EACH END 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 4 DF #2 HEADER 4 X 4 DF #2 HEADER X X TYP ALL WINDOWS TYP ALL DOORS TYP ALL COLUMNS BA-301 BA-301 AA-301 AA-301 BA-301 AA-301 AA-301 20'-0" 23'-6" 7'-8" 4 X 4 DF #2 HEADER 1 INTERIOR SHEAR WALL SCHEDULE WALL # 3/8" OSB OR CDX PANEL INSTALLED ON ONE SIDE OF THE WALL W/ 8d @ 6" EDGE AND 12" FIELD, BLOCKED ALL EDGES ASSEMBLY SCALE: 1/8" = 1'-0" MAIN FLOOR 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBA-102DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy Bunnell2ND FLOOR PLAN5 0F 21 SHEETS 5-0x5-05-0x5-05-0x5-05-0x5-0 3-0x6-8 3-0x6-8 5-0x5-05-0x5-03-0x6-83-0x6-83-0x6-8 3-0x6-83-0x6-8 3-0x6-8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 12345678910111213141516171812345678910111213141516171816'-5"4'-4"9'-10"4'-5"18'-3"11'-0"5'-9" 70'-0"52'-0"41'-5"10'-7"89'-5"10'-7"100'-0"70'-0" D D D D B D B S-503 1,2 S-503 6 S-503 5 S-503 7 OPEN TO BELOW MEZZANINE CLASSROOM CLASSROOM STORAGE RESTROOM SHOWER DRESSING STORAGE TYP ALL COLUMNS TYP ALL EAVESAT ICF WALLS AA-301 AA-301 BA-301 BA-301 A B C D (1) - #5 (1) - #5 (1) - #4 (1) - #4 #3 SINGLE LEG @ 12" O.C. MIN LINTEL HEIGHT 24" AMVIC 6" LINTEL SCHEDULE LINTEL #BOTTOM STEEL TOP STEEL STIRRUPS 12" (1) - #4 18"(1) - #5 #3 SINGLE LEG @ 6" O.C. FIRST 24" FROM SUPPORT THEN 12" O.C. (1) - #4 TO TOP OF WALL(1) - #5 STD #4 VERTS @ 12" O.C. #3 SINGLE LEG @ 12" O.C. SCALE: 1/8" = 1'-0" 2nd FLOOR 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBA-201DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellELEVATIONS6 0F 21 SHEETS EXISTINGBUILDING KINGSPAN KINGRIB INSULATED ROOFPANELS CLASS A COMPOSITIONSHINGLE ROOFING ORMETAL ROOFING 6 1218'-7"8'-9"3 COAT STUCCO OVER ICF WALL3 COAT STUCCO OVER ICF WALL TOP OF SLAB TOP OF WALL TOP OF GABLEEND WALL NEW CONSTRUCTION >< EXISTING BUILDING 12 3TYP 12 6 12 3 12 6 SCALE: 1/8" = 1'-0" RIGHT (SOUTH EAST) ELEVATION SCALE: 1/8" = 1'-0" REAR (NORTH EAST) ELEVATION SCALE: 1/8" = 1'-0" LEFT (NORTH WEST) ELEVATION SCALE: 1/8" = 1'-0" FRONT (SOUTH WEST) ELEVATION 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBA-301DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellSECTIONS7 0F 21 SHEETS8'-0"1'-0"9'-11"18'-11"16'-1"2'-7"3" CLEAR COVER @ SIDES AND BOTTOM3"2"18'-8"72" SQUARE X 30" DEEP FOOTINGS @ CONCRETE COLUMNS EMBED VERTICAL REBAR INTO FOOTING 24" AND TERMINATE W/ STANDARD HOOK 18" SQUARE CONCRETE COLUMN PER DETAIL 1/S-503 BEAM TO COLUMN CONNECTION PER DETAIL 2/S-503 EAVE STRUT TO ICF WALL CONNECTION PER DETAIL 6/S-503 RIDGE CONNECTION PER DETAIL 8/S-503 BOTTOM FLANGE BRACE CONNECTION @ 15' 0.C. MAX PER DETAIL 4/S-503 PURLIN TYP KINGSPAN KINGRIB 3 INSULATED ROOFING PANEL W21 X 62 BEAM BEAM AND COLUMN ARE MIRRORED ABOUT RIDGE PURLIN TO BEAM CONNECTION PER DETAIL 3/S-503 12 3TYP 2" CLEAR COVER @ TOP TOP OF SLAB TOP OF ICF WALL TOP OF COLUMN 2 X 4 FRAMED STUD WALL 11" LVL OR LSL RIM BOARDON TOP OF STUD WALL LSC STRINGER TO RIM BOARD 1 3/4" X 11 7/8" LVL 1.9ESTRINGERS. 4 TOTAL, 16" O.C. MAX SCALE: 1/4" = 1'-0" SECTION A SCALE: 1/4" = 1'-0" SECTION B 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-401DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellFOUNDATIONPLAN8 0F 21 SHEETS1'-0"3" (TYP)3" (TYP) 1'-9" PER PLAN 12" Ø X 12" HIGH CIP PIER FOOTING PER PLAN SIMPSON PBS44Z 4 X 4 PTDF POST25" MIN LAP3" MIN CLR FOOTING A 18" WIDE 18" EMBEDMENT 12" THICK 2- #4 REBAR AT BOTTOM OF FOOTING AMVIC ICF WALL W/ #4 REBAR @ 16" HORIZONTAL AND 18" VERTICAL (TYP) #4 REBAR W/ 6" HOOK @ 18" O.C. (TYP) XPS FOAM OR FELT THERMAL BREAK 4" CONCRETE SLAB W/ #3 REBAR @ 24" O.C.E.W. MIN 6 MIL VAPOR BARRIER MIN 4" COMPACTED GRAVEL BASE 24" FOOTING SCHEDULE FOOTING #WIDTH LONGITUDINAL REBAR (4)- #4A B DEPTH (2)- #412"12" 18" (1)- #4 LONGITUDINAL 2 X 4 PTDF SILL W/ 1/2" X 3" TITEN HD@ 48" O.C. MAX AT INTERIOR SHEAR WALLS. 2 X 4 @ 16" O.C. #3 REBAR @ 24" O.C.E.W. 4" CONCRETE SLAB OVER MIN 6 MIL MOISTURE BARRIER OVER 4" GRAVEL 16-0x5-0 3-0x6-84-0x6-8 4-0x6-8 3-0x6-8 100'-0"68'-3"7'-7"24'-2"17'-4"16'-4"16'-4"16'-4"16'-4"17'-4"11'-9"15'-3"10'-11"10'-11"32'-11" 70'-0" 70'-0" 6'-4"53'-5"7'-6"2'-8"5'-3"14'-4"14'-4"18'-1"4'-0"1'-0"11'-0"8'-0"3'-6"1'-6" 27'-0" 8'-0"1'-0"9'-0"52'-0"3'-6"3'-6"3'-6"3'-6" 6'-0"1'-3"7'-7"1'-3"12'-0" #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) #5 VERTICAL TRIMBAR @ EACH SIDE OFDOOR OPENING(SEE 10/S502) S-401 1 FOOTING A24" WIDE18" THICK18" EMBEDMENT 4" CONCRETE SLAB ONGRADE W/ #3 @ 18" O.C.E.W.OVER MOISTURE BARRIEROVER 4" OF CRUSHED ROCK FOOTING A24" WIDE18" THICK18" EMBEDMENT S-502 5 S-401 4 FOOTING A24" WIDE18" THICK18" EMBEDMENT FOOTING A24" WIDE18" THICK18" EMBEDMENT FOOTING A24" WIDE18" THICK18" EMBEDMENT FOOTING A24" WIDE18" THICK18" EMBEDMENT FOOTING A24" WIDE18" THICK18" EMBEDMENT 4" CONCRETE SLAB ONGRADE W/ #3 @ 18" O.C.E.W.OVER MOISTURE BARRIEROVER 4" OF CRUSHED ROCK 12" SQ X 12"THICK FTGW/ 2- #4 E.W. 72" SQ X 30"THICK FTGW/ 7- #5 E.W. @TOP OF FTG & 7-#5 E.W. @BOTTOM OF FTG(TYP FOR 10) FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING A24" WIDE18" THICK18" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT FOOTING B12" WIDE12" THICK12" EMBEDMENT S-502 10 S-502 6,7,8 S-401 3 S-502 10 S-401 2 S-503 1 24" SQUARE FTG. 12" DEEP W/ 3-#4 E.W., TYP OF 2. 36" SQUARE FTG. 12" DEEP W/ 5-#4 E.W. 36" SQUARE FTG. 12" DEEPW/ 4-#4 E.W., TYP OF 2.36" SQUARE FTG. 12" DEEPW/ 4-#4 E.W., TYP OF 2. 36" SQUARE FTG. 24" DEEPW/ 4-#4 E.W. AT TOP AND BOTTOM,TYP OF 2. 36" SQUARE FTG. 24" DEEPW/ 4-#4 E.W. AT TOP AND BOTTOM,TYP OF 2. 24" SQUARE FTG. 12" DEEP W/ 3-#4 E.W., TYP OF 3. HSS 4" X 4" X 3/16" STEEL POSTW/ 4- 5/8" X 12" AB'SPER DETAIL 9/S-503 TYP U.N.O.18" WIDE X 12" THICK STRIP FOOTING AT BASE OF STAIRSW/ 3-#4 LONGITUDINAL BARS.ANCHORS PER STAIR MANUFACTURERS SPECIFICATIONS. 21" SQUARE FTG. 12" DEEPW/ 3-#4 E.W., TYP OF 2. 21" SQUARE FTG. 12" DEEPW/ 3-#4 E.W., TYP OF 2. CBSQ POST BASETYP @ ALL EXTERIOR PORCHPOSTS CBSQ POST BASETYP @ ALL EXTERIOR PORCHPOSTS CBSQ POST BASETYP @ ALL EXTERIOR PORCHPOSTS CBSQ POST BASETYP @ ALL EXTERIOR PORCHPOSTS TYP ALLCORNERS TYP ALL DOORS TYP ALL DOORS TYP ALL PIERS TYP ALL COLUMNS BA-301 AA-301 AA-301 BA-301 LANDING @BOTTOM OFSTAIRS LANDING @DOOR LANDING @DOOR SCALE: 3/4" = 1'-0" 3 TYPICAL PIER DETAIL SCALE: 1/2" = 1'-0" 1 TYPICAL FOUNDATION AT SLAB DETAIL SCALE: 3/4" = 1'-0" 2 INTERIOR FOOTING DETAIL FOUNDATION PLAN (1) 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-402DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy Bunnell2ND FLOORFRAMING PLAN9 0F 21 SHEETS3-0x6-85-0x5-06-0x6-810-0x7-06-0x6-83-0x4-63-0x4-64-0x4-6 4-0x4-6 4-0x4-6 3-0x6-8 3-0x6-83-0x6-8 3-0x4-63-0x4-6 3-0x4-6 5-0x6-8 3-0x6-8 3-0x6-8 3-0x6-83-0x6-83-0x6-8 4-0x4-6 3-0x6-84-0x6-8 3-0x6-8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1234567891011121314151617181234567891011121314151617184 X 4 DF #2 POSTW/ PCZ4 POST CAP& ABU44Z BASE MOUNTEDTO CONCRETE W/ 1/2" ø X 4" TITEN BOLT 3.5" X 11 7/8" PSL 1.8E FLUSH BEAM 1 3/4" X 11 7/8" LVL 1.8E RIMBOARD 3.5" X 11 7/8" PSL 1.8E FLUSH BEAM 1 3/4" X 11 7/8" LVL 1.9E STRINGERS@ 16" O.C. MAX1 3/4" X 11 7/8" LVL 1.9E STRINGERS@ 16" O.C. MAX1 3/4" X 11 7/8" LVL 1.9E STRINGERS@ 16" O.C. MAX1 3/4" X 11 7/8" LVL 1.9E STRINGERS@ 16" O.C. MAX 1 3/4" X 117/8"LVL1.8E LEDGER TO ICF WALL.USE ICFVL & ICFVL-CW FROM LEDGER TO ICF WALLSPACED @ 48" ON THIS WALL LINE. 1 3/4" X 117/8"LVL1.8E LEDGER TO ICF WALL.USE ICFVL & ICFVL-CW FROM LEDGER TO ICF WALL SPACED @ 36" ON THIS WALL LINE. ITS1.81/11.88 HANGER ON LEDGER & FLUSH BEAMS(TYP EACH END OF EACH TJI 110 JOIST) ITS3.56/11.88 HANGER ON LEDGER(TYP EACH TJI 560 JOIST) 3/4" T & G OSB OR CDX W/ 8d NAILS @ 6" O.C. EDGES & 12" FIELD S-402 1 S-402 1 PREFAB STEEL STAIRS ANDCONCRETE TREADS BY MANUFACTURER ATTACH PREFAB STAIRS TO RETURN BEAMPER MANUFACTURER HSS 6 X 4 X 1/4 RETURN BEAMFOR STAIR CONNECTION DETAIL 11/S-503 HSS 6 X 4 X 1/4 STEEL BEAM L3 X 3 X 5/16" LEDGER TO CONCRETEW/ 5/8" X 8" (MIN 4" EMBEDMENT) HDGAB'S @ 48" O.C. PER LEDGER CONNECTION DETAIL 10/S-503 HSS 4 X 4 X 3/16 STEEL POSTTYP OF 3PER DETAIL 9/S-503 ASC 2WH-36 X 22 GA COMPOSITE METAL DECKW/ 4"O.C. NW 3500 PSI CONCRETEW/ 6 X 6 W 1.4 GALV WIRE MESH IN UPPER SLAB.ATTACH DECK TO BEAM ANDLEDGER USING ASC 36/4 PATTERN WITH EITHER PUDDLE WELDS OR #12 GALV TEK SCREWS 3.5" X 16" PSL 2.2E HEADERW/ 2- 2 X 4 TRIMMERS EACH END 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 8 DF #2 HEADER 4 X 4 DF #2 HEADER 11 7 /8 " TJI 560 @ 16 " O .C .11 7/8" TJI 110 @ 19.2" O.C.BA-301 BA-301 AA-301 AA-301 4 X 4 DF #2 HEADER4"4"12"7 1/2"10" FINISH DECKING (EXTERIOR) OR SUBFLOOR MATERIAL (INTERIOR) 4 X 8 PTDF JOIST (EXTERIOR) OR LVL RIMBOARD (INTERIOR) SIMPSON LSU26 HANGER (NOTCH STRINGER FOR HANGER) (4)-1 3/4" X 11 7/8" LVL 1.9E STRINGERS 1- SIMPSON A-35 @ EACH STRINGER TO SILL 6-1/4" X 3 1/4" TAPCONS EACH 2 X 6 PTDF SILL 7 3/4 " MAX RISE 10" MIN RUN SCALE: 1/8" = 1'-0" FLOOR FRAME PLAN SCALE: 3/4" = 1'-0" 1 STAIR DETAIL 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-403DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellROOF FRAMINGPLAN10 0F 21 SHEETS 5-0x5-05-0x5-0 6-0x6-83-0x6-85-0x6-8 3-0x6-8 3-0x4-63-0x4-61 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1234567891011121314151617181234567891011121314151617183:12 SLOPE3:12 SLOPE2'-0"CANTILEVER 2'-0"OVERHANG1'-0"11'-0"8'-0"EAVE STRUT PER DETAIL 6/S-503 KINGSPAN KING RIB 3, 6" THICK,SCREW TO EAVE STRUT W/ (4) 1/4" -14 SCREWS (2 EACH VALLEY)AND TO EACH PURLIN @ HIGH RIBS S-503 1,2 S-503 6 S-503 5 S-503 7 S-503 3,4 S-503 8 2 X 6 DF #2 RAFTERS @ 24" O.C. W/ H3 @ BEAM. HANGER ON LEDGERW/ U26 HANGERS USING SD9 SCREWS 6 X 6 DF#2 POST W/ BC6 TO POST(TYP OF 2) 6 X 8 DF#1 BEAM FULL HEIGHT BLOCKING BETWEEN BEAMS 2 X 6 DF #1 LEDGERW/ 5/8" ø X 10" (MIN 6" EMBED) HDGAB@ 36" O.C. @ MIDHEIGHT OF LEDGER2 X 8 DF #2 RAFTERS @ 24" O.C. W/ H3 @ BEAM. HANGER ON LEDGERW/ U26 HANGERS USING SD9 SCREWS 6 X 6 DF#2 POST W/ BC6 TO POST(TYP OF 3) 6 X 8 DF#1 BEAM FULL HEIGHT BLOCKING BETWEEN BEAMS 2 X 8 DF #1 LEDGERW/ 5/8" ø X 10" (MIN 6" EMBED) HDGAB@ 24" O.C., STAGGER TOP TO BOTTOMW/ 2" EDGE CLEARANCE OF LEDGER 15/32 OSB ORIENTED AS SHOWN W/ 8d @ 6" O.C. EDGES AND 12" FIELD 6 X 6 DF#2 POST W/ BC6 TO POST(TYP OF 2) 6 X 8 DF#1 BEAM FULL HEIGHT BLOCKING BETWEEN BEAMS 15/32 OSB ORIENTED AS SHOWNW/ 8d @ 6" O.C. EDGES AND 12" FIELD 6 X 6 DF#2 POST W/ CCQ TO POST(TYP OF 4) FULL HEIGHT BLOCKING BETWEEN BEAMS 15/32 OSB ORIENTED AS SHOWNW/ 8d @ 6" O.C. EDGES AND 12" FIELD 6 X 8 DF#1 BEAM 6 X 8 DF#1 BEAM 6 X 8 DF#1 BEAM MANUFACTURED TRUSSES @ 24" O.C.W/ SIMPSON H3'S TO BEAM AT EACH END OF TRUSS MANUFACTURED TRUSSES @ 24" O.C.W/ SIMPSON H3'S TO BEAM AT EACH END OF EVERY OTHER TRUSS HUC68 W/ TITEN 2 SCREWS TO CONCRETE HUC68 W/ TITEN 2SCREWS TO CONCRETE4 X 6 DF #2 POST IN WOOD WALL UNDER BEAMW/ 2 X 4 EACH SIDE OF BEAM FOR POCKET OVERBUILD TRUSSES BY TRUSS MANUFACTURER COMP OR METAL ROOFING 6 X 8 DF#1 BEAM GABLE OVERHANG BRACKET SPACED @ 5'-0" O.CSTARTING AT EAVE EDGE OF WALLPER OVERHANG BRACKET DETAIL 7/S-503 15/32 OSB ORIENTED AS SHOWNW/ 8d @ 6" O.C. EDGES AND 12" FIELD PURLIN TO ICF GABLE END WALLPER OVERHANG BRACKET DETAIL 5/S-503 8 ZS 2 .75 X 085 PURLIN S @ 5 ' O .C . (TYP )8 ZS 2 .75 X 085 PURLIN S @ 5 ' O .C . (TYP ) W21 X 62STEEL BEAM W21 X 62STEEL BEAM W21 X 62STEEL BEAM W21 X 62STEEL BEAM W21 X 62STEEL BEAMRIDGE TYP ALL COLUMNS TYP ALL EAVESAT ICF WALLS SCALE: 1/8" = 1'-0" ROOF FRAME PLAN 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-501DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellSTRUCTURALNOTES11 0F 21 SHEETS CONCRETE 1. STRUCTURAL CONCRETE SHALL ATTAIN 28 DAY COMPRESSIVE STRENGTH AS REQUIRED IN THIS SCHEDULE: 2. CONCRETE MIX DESIGNS SHALL BE PREPARED BY A READY MIX COMPANY. 3. CEMENT SHALL CONFORM TO ASTM C-150 TYPE I OR II. 4. CONCRETE AGGREGATES SHAL CONFORN TO ASTM C-33 FOR NORMAL WEIGHT CONCRETE. 5. NON-SHRINK GROUT OR DRYPACK SHALL CONSIST OF A PREMIXED NONMETALLIC FORMULA. 6. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60 FOR #4 AND LARGER, AND ASTM A-615 GRADE 40 FOR #3 AND SMALLER. 7. REINFORCING STEEL SHALL BE FABRICATED ACCORDING TO "MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION". 6. DIMENSIONS IN THE FOLLOWING SCHEDULE ARE SHOWN FOR LOCATION OF REINFORCING TO THE FACE OF MAIN BARS AND DENOTE CLEAR COVERAGE REQUIRED. 7. PROVIDE HOOKS AT ENDS OF ALL REINFORCING AT ENDS, CORNERS AND INTERSECTIONS UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD HOOKS UNLESS OTHERWISE SHOWN OR NOTED. 8. REMOVE ALL DEBRIS FROM FORMS BEFORE CASTING ANY CONCRETE. 9. REINFORCING DOWLES, ANCHORS, SLEEVER, ETC., TO BE EMBEDDED IN CONCRETE SHALL BE SECURELY POSITIONED BEFORE PLACING CONCRETE. 10. ANCHOR BOLTS CAST IN CONCRETE SHALL BE J-BOLTS WITH CUT THREADS CONFORMING TO ASTM A307, ASTM A36, OR ASTM A572 GR.50 AS INDICATED ON PLANS 11. WALLS SHALL BE CAST IN HORIZONTAL LAYERS OF 4'-0" MAX DEPTH. 12. DOWEL ALL VERTICAL REINFORCING IN WALLS AND COLUMNS FROM FOUNDATION WITH THE SAME SIZE BAR. 13. CONSOLIDATE CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT SUPPLEMENTED BY HAND-SPADING, RODDING OR TAMPING. USE EQUIPMENT AND PROCEDURES FOR CONSOLIDATION OF CONCRETEIN ACCORDANCE WITH THE RECOMMENDED PRACTICESOF ACI 309 TO SUIT THE TYPE OF CONCETE AND PROJECT CONDITIONS. 14. PROVIDE 2- #5 X 4'-0" DIAGONAL REINFORCING AT MID-DEPTH OF SLAB AT ALL RE=ENTRANT CORNERS (TYPICAL) 15. ALL SAW CUTTING SHALL BE DONE AFTER INITIAL SET HAS OCCURRED TO AVOID TEARING OR DAMAGE BY THE SAW BLADE, BUT BEFORE INITIAL SHRINKAGE HAS OCCURRED. 16. PROVIDE LAP SPLICES PER THE FOLLOWING SCHEDULE. THIS SCHEDULE APPLIES TO UNCOATED, GRADE 60 REINFORCING STEEL AND NORMAL WEIGHT CONCRETE W/ fc"= 3000 PSI. LOCATION f'c @ 28 DAYS MAX AGGREGATE SIZE SLABS ON GRADE/ FOOTINGS 2500 PSI 1" SLABS OVER PAN DECK 3000 PSI 1"1" SLABS OVER AMDECK 3000 PSI 1"1" ICF WALLS 3000 PSI 3/8" LOCATION MIN COVERAGE CONCRETE DEPOSITED DIRECTLY AGAINST GROUND (EXCEPT SLABS)3" 2"CONCRETE EXPOSED TO GROUND BUT PLACED IN FORMS 2"CONCRETE EXPOSED TO GROUND (TOP BARS CLEARANCE TO TOP UNO) TIED COLUMNS (MAIN BARS)2" BEAMS (TOP BARS)1 1/2" 2" WALLS (EXTERIOR FACE) 3/4" SLABS (ON FORMS (AMDECK OR PAN DECK)) 2" 1 1/2" BEAMS (ALL OTHER REINFORCING) WALLS (INTERIOR FACE) 3/4" SLABS (ON GROUND (CLEARANCE FROM TOP UNO)) REINFORCEMENT LOCATION #3 TOP 28" OTHER #4 #5 37"47" 22"29"36" #6 GENERAL NOTES 1. THE INTENT OF THESE DRAWINGS IS TO SHOW ALL NECESSARY ITEMS TO COMPLETE THIS STRUCTURE. TYPICAL DETAILS AND NOTES WITHIN THESE DRAWINGS APPLY TO SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. ALL WORK AND CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES, REGULATIONS, AND SAFETY REGULATIONS. FOR ITEMS, METHODS, AND/ OR MATERIALS NOT SHOWN, THE MINIMUM REQUIREMENTS OF THE CURRENT (2019) CALIFORNIA BUILDING CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA ELECTRICAL CODE, 2019 CRC, CGBSC AND ENERGY CODE, ASCE7-16, ACI318-14, AND ALL OTHER LOCAL STATE AND MUNICIPAL CODES AND ORDINANCES SHALL GOVERN. 2. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY REGULATIONS. 3. THE CONTRACTOR SHALL HOLD HARMLESS, INDEMNIFY AND DEFEND THE OWNER, DESIGNER, ENGINEER, AND HIS CONSULTANTS, AND EACH OF THEIR OFFICERS AND EMPLOYEES FROM ALL LIABILITY CLAIMS, LOSSES, OR DAMAGES ARISING OR SAID TO ARISE FROM THE PERFORMANCE OF WORK DESCRIBED HEREIN. 4. WHILE EVERY ATTEMPT HAS BEEN MADE TO AVOID MISTAKES IN THE PREPARATION OF THESE PLANS, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR, THEREFORE, THE DIMENSIONS AND SPECIFICATIONS OF THESE PLANS SHALL BE VERIFIED BY THE OWNER/ CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, AND ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER AND/OR THE ENGINEER OF RECORD. 5. THESE PLANS HAVE BEEN DRAWN TO COMPLY WITH THE CLIENTS SPECIFICATIONS, AND ANY CHANGES MADE TO THEM AFTER PRINTS ARE MADE SHALL BE DONE AT THE CLIENTS EXPENSE. 6. SHOULD AN ERROR APPEAR IN THE WORKING DETAILS OR SPECIFICATIONS OR IN WORK DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE DESIGNER AND/OR THE ENGINEER OF RECORD AT ONCE AND IN WRITING. IF THE CONTRACTOR PROCEEDS WITH THE WORK SO AFFECTED WITHOUT HAVING GIVEN SUCH WRITTEN NOTICE AND WITHOUT RECEIVING THE NECESSARY APPROVAL, DECISION OR INSTRUCTIONS IN WRITING FROM THE OWNER, THEN HE SHALL HAVE NO VALID CLAIM AGAINST THE OWNER FOR THE COST OF SO PROCEEDING. 7. THE CONTRACTOR SHALL NOTIFY THE DESIGNER AND/OR ENGINEER OF RECORD WHERE A CONFLICT OR DISCREPANCY OCCURS BETWEEN THE STRUCTURAL DRAWINGS AND ANY OTHER PORTION OF THE CONTRACT DOCUMENTS OR EXISTING FIELD CONDITIONS. IN CASE OF A CONFLICT BETWEEN STRUCTURAL DRAWINGS AND SPECIFICATIONS THE MORE RESTRICTIVE CONDITION SHALL TAKE PRECEDENCE UNLESS WRITTEN APPROVAL HAS BEEN GIVEN FOR THE LEAST RESTRICTIVE. 8. ANY SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE, OR DETAILS SHALL BE REVIEWED BY THE DESIGNER AND THE STRUCTURAL ENGINEER PRIOR TO PROCEEDING. SUCH REVIEW WILL BE ON A TIME AND MATERIAL BASIS TO THE GENERAL CONTRACTOR WITH NO GUARANTEE THAT THE SUBSTITUTION WILL BE ALLOWED. 9. DO NOT SCALE DRAWINGS. CONTACT THE DESIGNER OR ENGINEER OF RECORD FOR ANY DIMENSIONS NOT SHOWN. 10. FIRE, VANDALISM, AND THEFT INSURANCE ARE TO BE PROVIDED BY OWNER. PUBLIC LIABILITY AND WORKER'S COMPENSATION INSURANCE, IF APPLICABLE, ARE TO BE PROVIDED BY CONTRACTOR. 11. THE JOB SHALL BE LEFT BROOM CLEAN, WITH WINDOWS AND FIXTURES WASHED, AND ALL DEBRIS REMOVED BY CONTRACTOR. 12. THE CONTRACTOR SHALL GIVE THE DESIGNER 48 HOURS NOTICE MINIMUM WHEN SITE OBSERVATIONS ARE NECESSARY. 13. ANY AND ALL SURVEY AND SITE ENGINEERING WORK REQUIRED IN CONNECTION WITH THIS PROJECT SHALL BE BY SEPERATE CONTRACT BETWEEN OWNER / CONTRACTOR AND SURVEYOR OR ENGINEER OF CHOICE. 14. WHEN DISCREPANCIES ARISE BETWEEN ENGINEERING SPECIFICATIONS AND ARCHITECTURAL SPECIFICATIONS, THE ENGINEERS SPECIFICATIONS SHALL GOVERN. 15. THESE PLANS, SPECIFICATIONS, DETAILS, AND DESIGNS ARE THE SOLE PROPERTY OF RANDY W. BUNNELL CO. CONSTRUCTION IS LIMITED TO A ONE TIME USE ON THE PROPERTY NAMED HEREIN. THESE PAGES MAY NOT BE DISPLAYED, COPIED, OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF RANDY W. BUNNELL CO. 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-502DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellICF WALLSTRUCTURALDETAILS12 0F 21 SHEETS 18" MIN EMBEDMENT #4 REBAR AT TOP AND BOTTOM OF FOOTING #4 REBAR AT TOP AND BOTTOM OF FOOTING STEP FOUNDATION TO MEET GRADE STEP FOUNDATION TO MEET GRADE GRADE AMVIC ICF BLOCKS VERTICAL REBAR @ 18" O.C. OR AS REQUIRED FOR RETAINING WALL (SEE SCHEDULE ON FOUNDATION PLAN SHEET S4.1) 3 1 4 2 EMBED 12" INTO FOOTING OR 24" INTO WALL BELOW 1 2 3 4 OPENING OPENING AT ALL WINDOW AND DOOR OPENINGS PLACE 1- #5 REBAR AT TOP, BOTTOM AND SIDES OF OPENINGS. EXTEND REBAR 24" BEYOND THE OPENING. 24" 24" 24" 24" 1 1/2" CLR (TYP)SINGLE #5 REBAR HORIZONTAL AT TOP OF OPENING (AKA LINTLE BOTTOM STEEL) 1 SINGLE #5 REBAR VERTICALLY AT EACH SIDE OF OPENING 2 SINGLE TOP LINTLE STEEL (SEE LINTLE SCHEDULE FOR SIZE AND QUANTITY) 3 #3 STIRRUPS (SEE LINTLE SCHEDULE FOR SIZE, SPACING, AND PLACEMENT) 4 11"2 1/2"6"2 1/2"1'-0"1'-0"6"11"2 1/2"6"2 1/2"2 1/2"6"2 1/2"1 1/2" MIN1 1/2" MIN11" 6"2 1/2"1 1/2" MIN2 1/2"1 1/2" MIN11"6"9" VYCOR FLASHING Amvic ICF WALL Amvic ICF WALL WINDOW FLANGE WINDOW FLANGE BUCK MATERIAL MDF SILL APRON BUCK MATERIAL EXTERIOR DOOR HARDIPLANK SIDING INTERIOR DRYWALL SILL EXTENSION COMBO SILL EXTERIOR DOOR RABETED JAMB LP "SMARTRIM" EXTENSION LP "SMARTRIM" Amvic ICF WALL 9" VYCOR FLASHING INTERIOR DRYWALL STUCCO HORIZONTAL REBAR @ 16" O.C. #4 VERTICAL REBAR @ 18" O.C. (1) #5 HORIZONTAL REBAR TRIMBAR UNDER EACH SILL #4 VERTICAL REBAR @ 18" O.C. INTERIOR DRYWALL (1)- #5 VERTICAL REBAR TRIM BAR #4 VERTICAL REBAR @ 12" O.C.#4 HORIZONTAL REBAR @ 16" O.C. AMVIC ICF WALL AMVIC WEBS @ 6" O.C. 25" MIN LAP #4 VERTICAL REBAR @ 18" O.C. #4 (60 KSI) OR #5 (40 KSI) HORIZONTAL REBAR @ 16" O.C. AMVIC ICF WALL AMVIC WEBS @ 6" O.C. 25" MIN LAP Amvic ICF WALL STIRRUPS SIZED AND SPACED PER LINTEL SCHEDULE (ALTERNATE STIRRUP HOOKS TO BOTTOM STEEL IF APPLICABLE) LINTEL TOP STEEL QUANITY & SIZE PER LINTEL SCHEDULE LINTEL BOTTOM STEEL QUANITY & SIZE PER LINTEL SCHEDULE WINDOW FLANGE 9" VYCOR FLASHING FOAM BUCK CONCRETE STEMWALL EPS OR XPS THERMAL BREAK CONCRETE SLAB FINISH FLOOR Amvic ICF WALL STIRRUPS SIZED AND SPACED PER LINTEL SCHEDULE (ALTERNATE STIRRUP HOOKS TO BOTTOM STEEL IF APPLICABLE) LINTEL TOP STEEL QUANITY & SIZE PER LINTEL SCHEDULE LINTEL BOTTOM STEEL QUANITY & SIZE PER LINTEL SCHEDULE FOAM BUCK JAMB HEAD DOOR (1)- #5 VERTICAL REBAR TRIM BAR BUCK MATERIAL .. . . 1 WINDOW LINTEL DETAIL 6 DOOR LINTEL DETAIL 10 OPENING REINFORCEMENT DETAIL 2 WINDOW SILL DETAIL 3 WINDOW JAMB DETAIL 5 ICF CORNER REINFORCEMENT DETAIL 7 DOOR SILL DETAIL 8 DOOR JAMB DETAIL 4 ICF TEE REINFORCEMENT DETAIL 9 STEPPED FOOTING DETAILLINTEL HEIGHTPERSCHEDULE. . .STIRRUPHEIGHT PERSCHEDULE. .LINTEL HEIGHTPERSCHEDULESTIRRUPHEIGHT PERSCHEDULE24" NOT APPLICABLE TO THIS PROJECT NOT APPLICABLE TO THIS PROJECT . 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBS-503DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellSTEELSTRUCTURALDETAILS13 0F 21 SHEETS1'-6"SQUARE1 1/2" CLR1 1/2" CLR (12) #8 VERTICAL BARS EVENLY SPACED #4 HOOPS @ 6" O.C. #4 VERTICAL BARS @ 12" O.C AMVIC ICF WALL CAST IN PLACE CONCRETE COLUMN SPACED PER PLAN RUN HORIZONTAL #4 REBAR AT 16" O.C. CONTINUOUS FROM ICF WALL THRU COLUMN 4 1/2"SPACING 1'-6"SQ COLUMN PL 1/2" END PLATE PL 1/2" PLATE STIFFENERS EACH SIDE IN LINE WITH COLUMN W21 X 62 PAB6 X 30" EMBED (TYP OF 4 @ EACH COLUMN) PAB6 X 30" EMBED (TYP OF 4 @ EACH COLUMN) (12) #8 VERTICAL BARS PER COLUMN SPACED PER DETAIL 1 S-503 #4 HOOPS @ 6" O.C. ANGLE TOP HOOP WEDGE WASHERS (TYP)WEDGE WASHERS (TYP) 1 1/2" CLEAR BEAM TO TOP HOOP D PLATED PLATE W21 X 62 PAB6 X 30" EMBED (TYP OF 4 @ EACH COLUMN) 1/4 4 1/2"SPACING SIDE VIEW END VIEW 2'MAX KINGSPAN KINGRIB 3 ICF WALL (2) 1/4" ø SCREWS PER VALLEY & (1) 1/4" ø SCREW PER EACH RIB (2) 1/4" ø SCREWS PER VALLEY & (1) 1/4" ø SCREW PER EACH RIB (2) 1/4" ø SCREWS PER VALLEY & (1) 1/4" ø SCREW PER EACH RIB HSS 3 X 2 X 1/8 (4) 3/8" ø X 2" EMBED TITEN HD(4) 3/8" ø X 2" EMBED TITEN HD PL 1/8 PL 1/4 D PLATE1/8 1"6"1"1 1/2"4 1/2"1"2'-6"2'-6"1 1/2"1 1/2"1 1/2" W21 X 62 (4) 5/16" ø A307 BOLTS (2) 5/16" ø A307 BOLTS@ ENDS OF LAP, (TYP) LAP PURLINS 5'-0" @ BEAM OR RUN PURLIN CONTINUOUS OVER TOP OF BEAM D PLATE PL 7 x 8 x 1/4 PLATETO BEAM AT 5'-0"FOR PURLINSUPPORT 1/8 1"2"8ZS 2.75 X 085 PURLIN @ 5'-0" O.C. 3/8" ø A307 BOLT L 2 X 2 X 1/4 W21 X 62 3- #12 TEK SCREWS3- #12 TEK SCREWS3- #12 TEK SCREWS PL 1/4 X 4 X 4 D PLATE2"1"45° 1/8 1" 2"2"1 1/2"4"1 1/2"7"4"7" 1 1/2"4"1 1/2"1 1/2"4"1 1/2"(4) 3/8" ø x 2.5" EMBED TITEN HD (2) 1/2" ø A307(2) 1/2" ø A307 9/16" ø HOLES 7/16" ø HOLES ICF GABLE D PLATED PLATE PURLIN P 7 X 7 X 1/4" P 7 X 4 X 1/4" 1/81/8 L L KINGSPAN KINGRIB 3 (2) 1/4" ø SCREWS PER VALLEY & (1) 1/4" ø SCREW PER EACH RIB 3/8" ø X 2 1/2" EMBED TITEN @ 18" O.C. EAVE STRUT ICF WALL MATCH 3:12 ROOF PITCH 12 3 2 1/2" 2 1/2" 6" 1" 1" 14 GAUGEEAVE STRUT 1'-0" 2"8"2"2'-4"2"2'-0"2"3 1/2"1'-9"3 1/2"W21 X 62 PL 1 1/2" X 12" X 28" D PLATE D PLATE MATING PLATE P 1/8" STIFFENER PLATEIN LINE W/ WEB P 1/8" STIFFENER PLATEIN LINE W/ WEB P 1 1/2" X 12" X 28" MATING PLATES D PLATE D PLATE 1 5/16" ø HOLES FOR1 1/4" ø A325(N) BOLTS(TYP FOR FOUR) KINGSPAN KING RIB 3 ROOFING 5/16 1/4 1/4STIFFENER TO BEAM(TYP) L L L 5/16BEAM TO PLATE(TYP)1 1/2"3"2"1 1/2"3"1 1/2" P 1/4" X 6" X 6.5" 0 7 /16" ø HOLES HSS 3 X 2 X 1/8" 1/8" L HSS 6 X 4X 1/4" BEAM HSS 4 X 4X 3/16" BEAM P 1/8" COVER PLATE @ END OF BEAMP 1/8" COVER PLATE @ END OF BEAM P 10 X 10 X 1/4"BASEPLATE #Hotlink and Element ID#Hotlink and Element ID #Hotlink and Element ID L L 1/8"3/16" 3/16" 1 1/2"7"1 1/2"1 1/2"7"1 1/2"0 3/4" ø HOLES FOR5/8" ø X 12" HDGAB'S P 1/4" X 10" X 10" HSS 4 X 4 X 3/16" 3/16" L 4"MIN ICF WALL 3" ø HOLE IN ICF WALL @BOLTSO THAT CONCRETE CAN FILL BEHIND LEDGER. CENTER BOLT IN HOLE. ASC METAL PAN DECK CONCRETE DECK ATTACH DECK TO HORIZONTAL LEGOF LEDGER USING 36/4 PATTERN L 3 X 3 X 5/16 LEDGER DOUBLE NUT 5/8" ø HDGAB @ 48" O.C. PLACED AT CENTERLINE OFVERTICAL LEG OF LEDGER 1 1/2"7"1 1/2"1 1/2"9"1 1/2"0 3/4" ø HOLES FOR 5/8" ø X 12" HDGAB'S P 1/4" X 12" X 10" HSS 6 X 4 X 1/4" 1/4" L 4"MIN ICF WALL 5/8" ø HDGAB.USE EITHER AB'SOR F1554 GR 36 THREADED ROD SET IN SIMPSON SET-3G EPOXY CUT AWAY FOAM AT PLATE RETURN DECK BEAMMAIN DECK BEAM 0 01/4"1/4" 1 COLUMN SECTION DETAIL SCALE: 1/2"=1'-0" 2 BEAM TO COLUMN DETAIL SCALE: 3/8"=1'-0" 3 PURLIN TO BEAM DETAIL @ LAPS SCALE: 3/4"=1'-0" 4 BOTTOM FLANGE BRACE DETAIL SCALE: 3/4"=1'-0" 5 PURLIN TO ICF GABLE END DETAIL SCALE: 3/4"=1'-0" 6 EAVE STRUT DETAIL SCALE: 3/4"=1'-0" 7 GABLE OVERHANG DETAIL SCALE: 3/4"=1'-0" 8 RIDGE DETAIL SCALE: 1/2"=1'-0" 9 STEEL POST DETAIL SCALE: 3/4"=1'-0" 10 DECK LEDGER DETAIL SCALE: 3/4"=1'-0" 11 DECK RETURN BEAM DETAIL SCALE: 3/4"=1'-0" 10/26/2022, 8:45:27 AM CONSULTANTS REVISED BY:CHK'D BY: RWBM-601DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellPLUMBING PLAN14 0F 21 SHEETS 5-0x5-04-0x3-0 5-0x5-0 5-0x5-05-0x5-05-0x5-05-0x5-0 3-0x6-8 3-0x6-83-0x6-8 3-0x6-8 5-0x5-05-0x5-05-0x5-05-0x5-05-0x5-03-0x6-83-0x4-63-0x4-6 3-0x4-6 6-0x6-85-0x5-06-0x6-810-0x7-03-0x6-86-0x6-816-0x5-0 3-0x6-84-0x6-8 4-0x6-8 3-0x6-8 3-0x6-8 3-0x4-63-0x4-64-0x4-6 4-0x4-6 4-0x4-6 3-0x6-8 3-0x6-83-0x6-8 10-0x7-03-0x4-63-0x4-6 3-0x4-6 5-0x6-8 3-0x6-8 3-0x6-8 3-0x6-83-0x6-83-0x6-8 3-0x6-8 4-0x4-6 3-0x6-84-0x6-8 3-0x6-8 4-0x6-8 5-0x5-04-0x3-0 5-0x5-0 5-0x5-05-0x5-05-0x5-05-0x5-0 3-0x6-8 3-0x6-83-0x6-8 3-0x6-8 5-0x5-05-0x5-05-0x5-05-0x5-05-0x5-03-0x6-83-0x4-63-0x4-6 3-0x4-6 6-0x6-85-0x5-06-0x6-810-0x7-03-0x6-86-0x6-83-0x6-85-0x6-8 3-0x6-8 3-0x6-83-0x6-8 3-0x6-8 4-0x4-6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 123456789101112131415161718123456789101112131415161718RG FFDW DW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 123456789101112131415161718123456789101112131415161718PLUMBING PLAN (1)PLUMBING NOTES: SHOWERS: 1. ALL SHOWER COMPARTMENTS (REGARDLESS OF SHAPE) SHALL HAVE A MINIMUM INTERIOR FLOOR AREA OF 1,024 SQUARE INCHES AND BE CAPABLE OF ENCOMPASSING A 30" CIRCLE. THE FINISHED FLOOR OF THE RECEPTOR SHALL SLOPE UNIFORMLY FROM THE SIDES TOWARD THE DRAIN NOT LESS THAN 1/4" PER FOOT NOR MORE THAN 1/2" PER FOOT. 2. SHOWER DOORS SHALL BE SIZED TO MAINTAIN NOT LESS THAN A 22" UNOBSTRUCTED OPENING IN THE OPEN POSITION. 3. SHOWERS AND TUB/ SHOWER COMBINATIONS ARE TO BE PROVIDED WITH A PRESSURE BALANCE OR THERMOSTATIC MIXING VALVECONTROL WHICH LIMITS THE TEMPERATURE OF THE WATER DISCHARGED TO 120° F. 4. SHOWERS AND TUB/SHOWER COMBINATION WALLS ARE TO HAVE A SMOOTH, HARD, NON ABSORBENT SURFACE OVER AN APPROVED MOISTURE RESISTANT UNDERLAYMENT TO A HEIGHT OF 72" MINIMUM ABOVE THE DRAIN INLET. PIPING: 1. ALL PLASTIC PIPING AND FITTINGS, OTHER THAN THOSE USED FOR GAS, SHALL CONFORM WITH THE REQUIREMENTS OF THE NATIONALSANITATION FOUNDATION 61. 2. ALL PIPE, TUBE, FITTINGS, SOLVENT, CEMENT, THREAD SEALANT, SOLDER AND FLUX USED IN THE POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER SHALL CONFORM WITH THE REQUIREMENTS OF THE NATIONAL SANITATION FOUNDATION 61. 3. UNDERFLOOR CLEANOUTS SHALL NOT BE MORE THAN 5 FEET FROM AND UNDERFLOOR ACCESS, ACCESS DOOR OR TRAP DOOR. (CPC707.9) 4. ABS PIPING SHALL NOT BE EXPOSED TO DIRECT SUNLIGHT UNLESS PROTECTED BY WATER BASED SYNTHETIC LATEX PAINT. (CPC312.13) 5. PVC PIPING SHALL NOT BE EXPOSED TO DIRECT SUNLIGHT UNLESS PROTECTED BY WATER BASED SYNTHETIC LATEX PAINT, .04" THICK WRAP OR OTHERWISE PROTECTED FROM UV DEGRADITION. (CPC312.14) 6. DOMESTIC HOT WATER LINES SHALL BE INSULATED. INSULATION SHALL BE THE THICKNESS OF THE PIPE DIAMETER UP TO 2" IN SIZE. (CPC 609-11) 7. PROVIDE ANTI-SIPHON VALVES ON ALL HOSE BIBS. (CPC 603.5.7) FLOW RATES: 1. THE MAIXIMUM FLOW RATES SHALL BE: (CGBSC 4.303.1) ° WATER CLOSETS: 1.28 gpf ° URINALS: .125 gpf ° KITCHEN FAUCETS: 1.8 gpm @ 60 psi ° LAVATORY FAUCETS: 1.2 gpm @ 60 psi ° SHOWER HEADS 2 gpm CONSULTANTS REVISED BY:CHK'D BY: RWBM-602DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellELECTRICALPLAN15 0F 21 SHEETS 4-0x3-05-0x5-05-0x5-0 5-0x5-05-0x5-05-0x5-03-0x6-83-0x4-63-0x4-6 3-0x4-6 6-0x6-85-0x5-06-0x6-810-0x7-06-0x6-816-0x5-0 3-0x6-84-0x6-8 4-0x6-8 3-0x6-8 3-0x6-8 3-0x4-63-0x4-64-0x4-6 4-0x4-6 4-0x4-6 3-0x6-8 3-0x6-83-0x6-8 10-0x7-03-0x4-63-0x4-6 3-0x4-6 5-0x6-8 3-0x6-8 3-0x6-8 3-0x6-83-0x6-83-0x6-8 3-0x6-8 4-0x4-6 3-0x6-84-0x6-8 3-0x6-8 4-0x6-8 5-0x5-04-0x3-0 5-0x5-0 5-0x5-05-0x5-05-0x5-05-0x5-0 3-0x6-8 3-0x6-83-0x6-8 3-0x6-8 5-0x5-05-0x5-05-0x5-05-0x5-05-0x5-03-0x6-83-0x4-63-0x4-6 3-0x4-6 6-0x6-85-0x5-06-0x6-810-0x7-03-0x6-86-0x6-83-0x6-85-0x6-8 3-0x6-8 3-0x6-83-0x6-8 3-0x6-8 4-0x4-6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 123456789101112131415161718123456789101112131415161718RG FFDW DW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 123456789101112131415161718123456789101112131415161718220220AC CONDENSOR AC CONDENSOR DISCONNECT AC CONDENSOR 200 AMPELECTRICAL SUBPANEL UFER GROUND LOCATIONPROJECTED TO SERVICE PANEL LOCATION DUCTLESS MINI SPLITHVAC DUCTLESS MINI SPLITHVAC DUCTLESS MINI SPLITHVACDUCTLESS MINI SPLITHVAC HVAC REGISTER GFCI outlets are required: for all kitchen receptacles that aredesigned to serve countertop surfaces, dishwashers,bathrooms, in under-floor spaces or below grade level, inunfinished basements, crawl space lighting outlets, in exterioroutlets, within 6’ of a laundry/utility/wet bar sinks, laundryareas, and in all garage outlets including outlets dedicated to asingle device or garage door opener. (CEC 210.8) Work surfaces and similar areas counter outlets must beinstalled in every counter space 12” inches or wider, notgreater than 4’ o.c., within 24” inches of the end of anycounter space and not higher than 20” above counter.(CEC 210.52 (C)) SEWINGSTORAGE (N) WOMEN (N) MEN (N) STORAGE (N) KITCHEN (N) CLASSROOM (N) GYM ELECTRICAL PLAN CONSULTANTS REVISED BY:CHK'D BY: RWBDRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellM-2.1MECHANICALPLAN LOWERFLOOR16 0F 21 SHEETS16 0F 21 SHEETS CONSULTANTS REVISED BY:CHK'D BY: RWBM-2.2DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellMECHANICALPLAN UPPERFLOOR17 0F 21 SHEETS17 0F 21 SHEETS CONSULTANTS REVISED BY:CHK'D BY: RWBDRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellT-24.118 0F 21 SHEETS 18 0F 21 SHEETS CONSULTANTS REVISED BY:CHK'D BY: RWBDRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellT-24.219 0F 21 SHEETS 19 0F 21 SHEETS CONSULTANTS REVISED BY:CHK'D BY: RWBDRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellT-24.320 0F 21 SHEETS 20 0F 21 SHEETS CONSULTANTS REVISED BY:CHK'D BY: RWBP-701DRAWN BY:CHK'D BY:REVISED BY:SIGNED BY:COPYRIGHT:DATE:DATE:DATE:DATE:DATE:DATE:DATE: 7/11/20 RWB 3/606/2175 LOS VERJELES ROADBANGOR, CALIF 95914MARANATHA FELLOWSHIPAPN: 028-260-070-000SCL#330645Residential Design and Building ServicesSPECIALIST IN ICF CONSTRUCTION530-277-447414314 Wrangell Ct.Penn Valley, CA 95946BunnellCowww.bunnellco.comA PROPOSED ADDITION FORALL CONSTRUCTION AND PROCEEDURES SHALL COMPLYWITH THE 2019 CBC, CRC, CMC, CEC, CPC, CENC, CGBSC,CHAPTER 7A OF THE 2016 CALIFORNIA BUILDING CODEWILDLAND URBAN INTERFACE (WUI) BUILDING STANDARDSAS WELL AS APPLICABLE LOCAL ORDINANCES.ALL MATERIALS USED SHALL COMPLY WITH CRC SECTIONR337 REQUIREMENTS FOR EXPOSURE TO WILDFIRERandy BunnellSITE PLAN21 0F 21 SHEETS N NE EL E V SW EL E V S E ELEVNW ELEV 800 810 790 780 770 +/- 150' WELL (E) LEACHFIELD (E) SEPTICTANK CREEK (E)PARKING 720'530' 478'617301 ' 16' LO S VE R J E L E S RD .40'SITE PLAN