HomeMy WebLinkAboutB22-4218 THE RIDGE LOT 108 PLAN 4R RevisedBASE CORE, LLC0 LARIAT LOOPAPN: 069-640-036§ 1276.01. Building and Parcel Siting and Setbacks. Setback for Structure Defensible Space(a) All parcels shall provide a minimum thirty (30) foot setback for all buildings from allproperty lines and/or the center of a road, except as provided for in subsection (b).(b) A reduction in the minimum setback shall be based upon When a thirty (30) foot setback isnot possible for practical reasons, which may include but are not limited to, parceldimensions or size; topographic limitations; development density requirements or otherdevelopment patterns that promote low-carbon emission outcomes; sensitive habitat; or othersite constraints easements, and shall provide for an alternative method to reduceStructure-to-Structure ignition by incorporating features such as, but not limited to:Same practical effect options may include, but are not limited to:(1) non-combustible block walls or fences; or(2) five (5) feet of non-combustible material extending five (5) feet horizontally from thefurthest extent of the building; or(3) installing hardscape landscaping or reducing a reduction of exposed windows on the sideof the structure with a less than thirty (30) foot setback; or(4) exceeds the requirements in the California Building Code,California Code of Regulations Title 24, Part 2, Chapter 7A, requested by the AHJ. Note: Authority cited: Section 4290, Public Resources Code. Reference: Sections 4290 and 4291,Public Resources Code.Applicant will install a method as mentioned in the California Code of Regulations Section1276.01 that meet the same practical effect for setback variance.