Loading...
HomeMy WebLinkAboutB22-4214 THE RIDGE LOT 103 PLAN 1 RevisedBASE CORE, LLC0 THUNDER ROCK RDAPN: 069-640-031§ 1276.01. Building and Parcel Siting and Setbacks. Setback for StructureDefensible Space(a) All parcels shall provide a minimum thirty (30) foot setback for all buildingsfrom all property lines and/or the center of a road, except as provided for insubsection (b).(b) A reduction in the minimum setback shall be based upon When a thirty (30)foot setback is not possible for practical reasons, which may include but arenot limited to, parcel dimensions or size; topographic limitations; development density requirements or other development patterns that promote low-carbonemission outcomes; sensitive habitat; or other site constraints easements, andshall provide for an alternative method to reduce Structure-to-Structure ignitionby incorporating features such as, but not limited to:Same practical effect options may include, but are not limited to:(1) non-combustible block walls or fences; or(2) five (5) feet of non-combustible material extending five (5) feet horizontallyfrom the furthest extent of the building; or(3) installing hardscape landscaping or reducing a reduction of exposedwindows on the side of the structure with a less than thirty (30) foot setback; or(4) exceeds the requirements in the California Building Code,California Code of Regulations Title 24, Part 2, Chapter 7A, requested by theAHJ. Note: Authority cited: Section 4290, Public Resources Code. Reference:Sections 4290 and 4291, Public Resources Code.Applicant will install a method as mentioned in the California Code ofRegulations Section 1276.01 that meet the same practical effect for setbackvariance. Window Abbreviations FX - Fix Window TS - Above Transom OX - Hoz. Slide Window SH - Single Hung Type CS - Casement Type AW- Awning Type FLOOR PLAN SCALE 1/4" = 1'-0" PROPOSED 2313 SF ChestNight StandNight StandFull Bed2480248028803080 TEMP.28808080 GARAGE DOOR16080 GARAGE DOOR288024802880 2480 LAUNDRY 10' CEILING BATH 10' CEILING BEDROOM 2 10' CEILING BEDROOM 3 10' CEILING DINING 10' CEILING GREAT ROOM 10' CEILING BATH 2 10' CEILING 2020 FX2020 FX 2020 FX TEMP. 3050 SH3050 SH 2020 FX2020 FX TEMP. 3050 SH 3050 SH2020 FX3-CAR GARAGE 10' CEILING ENTRY 10' CEILING 2880 3'-51 2"4"1'-6"1'-8" 10'-51 2"2'-10"4'-10"7'-0" 1'-6" 6'-0" 1'-6" 3'-2" 8'-91 2"5'-41 2"13'-21 2" 1'-11"3'-6"4" 74'-111 2"20'-0"13'-9"1'-812"1'-812"12'-0"2'-0"2'-0"6" 2'-0" 2'-0" 3040 SH 36" stove800 cfm fanDWREF.KITCHEN 10' CEILING King BedChest Night StandNight StandBEDROOM 1 10' CEILING MS BATH 10' CEILING MS W.I.C.-2 10' CEILING MS W.I.C.-1 10' CEILING 3050 FX 3050 SH3050 SH (MASTER SUITE) 1'-81 2"1'-81 2"2'-512"17'-112"10'-0"6'-1012"2'-0"3'-1014"3'-111 2"34'-0"34'-0" 8080 S.D. temp.5'-0"18'-0" 51 2"512"3'-112"1'-1012"5050 FX 5050 OX28802480 2480248024802480 2'-0"6'-0"9'-1012"5050 FX PANTRY 10' CEILING 5'-0" 16'-0" 16'-31 2"2'-8"3'-11"8'-7" 16'-9"2020 FX2020 FX2020 FX2020 CS TEMP.2020 TS2040 SH 93 4"3'-13 4"9" 1 1 1 2 2 2 33 3 44 4 555 66 6 7 7 7 88 8 MAIN PANEL A/C P A D 11 11 12 13 14 15 16 1616 16 22x30 Attic 19 20 21 23 23 24 24 25 2525 26 26 26 27 27 27 28 28 28 29 30 30 30 5'-0"9'-1012"48'-1012"74'-111 2"45'-9"22'-8"29'-101 2" 6'-51 2"4'-10"7'-4"11'-3"3'-8"6'-6"3'-9"6'-6" 16'-9"6'-734"3'-112"32'-0"3'-1112"8'-312"10'-51 2"2'-8"12'-0"6'-0"9'-912"3'-1112"1'-6"8'-312"3'-1112"5'-6"4'-312"3'-6"17'-1114"5'-6"2'-012"3'-6"2'-812"2'-4"27'-912"38'-412"4'-10"7'-4"14'-11"6'-6"3'-9"6'-6"1'-6"6'-012"1'-6"4'-10" 2'-6"5'-0"6'-012"3'-812"4'-10"4'-8"5'-0"4'-0"5'-0"9'-0"17'-112"10'-0"6'-1012"4'-3"2'-712"3'-6"6'-112"4'-21 2"2'-31 2" 3'-9"2'-71 2"6'-7"10'-312"16'-1012"17'-112"33'-61 2"25'-11 2" 25'-11 2"18'-10"8'-2"3'-7"13'-312"7'-612"3'-812"2'-012"9'-91 2"12'-51 2" 3'-0" 4"2'-71 2"4"30'-7"2'-113 4"6" 10'-10"2'-0"2'-0"9'-0" 12'-0"512"512"2'-2"5'-9"FRONT PORCH 10' CEILING 1'-6"Access REAR PORCH 10' CEILING PROVIDE 58" TYPE X GYP. BOARD @ WALLS & CEILING OF GARAGE, WHERE BACKING SUPPORT OF STUD @ 16" O.C., (TAPE, TEXTURE, & PAINT) - WALL TYP. GARAGE NOTE 43'-1012"3" Dia. x 36" high min. post with filled concrete for HW protection of vehicle impaction W.H. HYBRID HEAT-PUMP WATER HEATER PER T24 31 23 3 INCHES FEET WINDOW SIZE ABBREVIATIONS HEIGHT WIDTH 2 30 Concrete landings or finish at the required egress door shall not be more than 1.5" lower that the top of the threshold (Exception: 7.75" max if door does not swing over landing or floor) per CRC section R311.3.1. Tempered glass doors/ cover for shower and bath tub 12 Plumbing wall with 2x6 stud wall11 15 Combustion air from exterior for gas HW 17 9 10 3 2 KEY NOTES 1 22 19 16 20 Hot mop or sheet membrane system under 11 2" mortar bed with reinforcing, and 1 2" thick tile (hard surface) in shower. 21 23 Hot mop or sheet membrane system under 11 2" mortar bed with reinforcing, and finishing with thick layer of light concrete (hard surface) at balcony with stucco finish @ ceiling. Min 2% slope. 24 Provide 5'x8' pad in attic for HVAC with min clearance of 30" head room and 5'-0" wide. Switch and light is provided near by. Provide 24" cat walk from HVAC to the nearest access from min of 20'-0" away. Permanent electric outlet and lighting fixture control by a switch located at the attic access, and near by the furnace are required. Cooling unit should have the 2nd watertight pan installed beneath the unit 3" min. step of finish framing floor between living and balcony typical. 1-3/8" solid core door, or 20 minutes fire proof door (self closing) Required 24" flat from catwalk to FAU (not to exceed 20 ft) with light and switch near by access. Min. of 30" headroom req'd Hot water gas exhaust to the exterior provide PRV drain pipe from HW to the exterior Smooth metal duct for dryer exhaust extending to outside with back draft damper this duct shall not exceed a total combined horizontal and vertical length of 14' including two 90° elbows. Two feet shall be deducted for each 90° elbow in excess of two A minimum of 22"x30" readily accessible attic access with a minimum of 30" headroom above for each separate attic area. No shelving below attic access. Attic must be readily accessible Provide a fire resistive separation between garage and dwelling All porch ceilings with stucco finish are to be sheathed with 58" OSB and ring sinker nails for stucco support typ. If there is no gal. metal sheet layer provided. Direct vent gas fire place by MONTIGO or equal. Model C34-DV, or equal. 6 Glazing in enclosures for or walls facing hot tubs, whirlpools, saunas, showers, steam rooms and bathtubs where bottom edge of glazing is less than 60" measured vertically above any standing or walking surface shall be tempered. CRC R308.4 18 Gas vents shall terminate not less than 2' above the highest point where they pass through the roof and at least 2 feet higher than any portion of a building within 10'. Gas vents smaller than 12" in diameter may terminate at least 1' above the roofs up to a 6:12 pitch and at least 8' from any portion of the building. For higher roof pitches refer to Figure 8-2. CMC 802.6.2 Vents for fuel burning appliances other than direct-vent appliances shall terminate at least 4' below, 4' horizontally from, or 1' above any door, operable window, or gravity air inlet into the building. The bottom of the vent shall be located at least 12" above the grade. CMC 802.8.2 Clothes dry vent shall be vented to the outdoors.13 25 Egress windows with min of 5.7 sf opening, min. of 24" height clear, and 20" wide clear is required. max. of 44" from finish floor to the opening bottom of windows 26 Minimum 36" deep landing outside the main exterior egress door, the landing shall not be more than 7.75" lower than the threshold for the main entrance in-swing door, (1-1/2" for out swinging) 7 Toilets shall not be installed closer than 15" from center to any finish wall or obstruction and also with a minimum of 24" clear floor space in front of the toilet. 4 Showers and tub shower combinations that a pressure balance or thermostatic type mixing valve shall be provide to deliver a maximum water temperature of 120 degrees at the fixture. 5 Non adsorben surface at tub walls should continue to a height of 6ft above finished floor. 14 Provide Door with min 10"x14" louver or vent to make up air in laundry area. per CMC sec. 504.3.1 8 SHOWER: water-resistant gypsum board shall not be installed in a shower or tub compartment and shall not be used where there will be direct exposure to water, or in areas subject to continuous high humidity per CRC Sec. R 702.3.8 & R702.3.8.1. Landing shall have MAX. 2% slope away from foundation - typ. 28 7-34" maximum vertical change in elevation at the new exterior doors CRC R311.3.2 27 Min 2% slope @ garage finish. It shall be sloped to facilitate the movement of liquids to an approve drain or toward the main vehicle door 29 Shower compartment regardless of shape, having a minimum of interior floor area of 1,024 square in, and also capable of encompassing 30 in circle -Opening shower access should not be less than 22" -Provide with pressure balance or thermostatic mixing valve controls. -Wall should have a smooth, hard, nonabsorbent surface (e.g.., ceramic tile) over an approved moisture resistant underlayment or Hardi Backer Fibercement board Layer, height to be 72" above the drain inlet 31 HOT WATER TANK seat on 18" high flat form. See TiTLE 24 for size specification, and type. NOT USED NOT USED WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. Contractors and home owner builders shall verify and be responsible for dimensions and conditions of the project. Fineline Drafting services must be notified of any variation from the dimensions, conditions and specification appearing on this plan.DRAFTING INC.FinelineOWNER / CONTRACTOR NOTE: ALL OF THE VERIFYING PLUS / MINUS DIMENSIONS ON THE PLANS ARE TO BE DISCUSSED WITH THE DESIGNER OR ENGINEER BEFORE THE CONSTRUCTION BY THE CONTRACTOR AND OWNER. DATE PROJECT 21-201-1 Sheet Icon Partners LLCContact: Vlad K.OWNER- CONTACTMASTER PLAN 1THE RIDGE SUBDIVISIONOROVILLE, CA STAMP DESIGNER GOPH (916) 332 2282 5777 Madison Ave suite 520, Sacramento, CA 95841fineline300@Comcast.netwww.finelinedraftinginc.comSHEET TITLEPROJECT NAMEACLIF RONIA G 4 Fineline rp NFIT -2 D Co AR NI 84 62 4 .C 12/07/2022 ALTERNATE PLUMBING MATERIAL P.E.X PLASTIC IS PROPOSED TO BE USED IN THIS BUILDING. SEE page A1.2 & AG1 for Building Code requirements F L O O R P L A NA3