Loading...
HomeMy WebLinkAboutFAI18-0010 FA 2022 ALARM AND DETECTION REPORT Page 1 of 5 VOLTAGE' pEaAum a c+o+CutLicense MOM rorner-Voltsesapecialtuts.comet Inspection# ALARM &DETECTION EQUIPMENT TEST REPORT Type of Inspection:Annual Date: 2/18/22 Customer Nord Country School Site: Nord Country School Street: 554 California St. Contact: Ed Johnson City/State: Nord CA Phone#: 530-518-0280 Fax#: 530-891-3273 1. Before Test Notify Proper Authorities: Name Phone# A Owner or Owners Rep Ed Johnson 530-518-0280 B. Fire Department Cal Are C. Central Station GSM 1800-722-0364 D. Central Station Acct# 40 8 2. Control Panel Status Yes No Note# A Is the system monitored by Central Station? X On Test Time: 720 Return to Service Time: 11700 B. Is the Power Light on? X C. Does the Panel indicate Normal conditions? X D. Are all indicating Lamp Bulbs in Operator order? X E. Does the Trouble Light operate? X F. Does the Silence Switch Operate? X G. Battery AH.8 Date Batteries Installed 8/16/17 H. Does the Panel have Non-Operational Zones? A I. Does the Panel have Battery Backup? X J. Do the batteries iidcate they are Properly Charged? X Condition of Batteries: Good Meet; Battery Voltage with AC Power. 27.13 Battery Voltage without AC Power 25.68 K. List any trouble conditions on panel before test: Note# Note# Comments: Nate# Note# 3. FACP Manufacturer: Silent Knight Model#5820XL-EVS System Type: Addressable Location of Annunciators: N/A Location of Primary Power Source:Switch Gear Panel# Breaker Comments: Note# Breaker is ahead of main breaker Note# FCPS: Manufacturer: Went Knight Model# 5t995 Paretneadier# Location:Room 6 Battery Voltage with NC Power. 27.36 w/o NC Power 2735 Date: 8/16/17 FCPS: Manufacturer Wheelock Model# Panela eaimr# Location:Room 11 Battery Voltage with A/C Power. 27.33 wlo A/C Power ?za1 Date: 6119/19 FCPS: Manufacturer: Silent knight Model# EVS-50W wreaker# Location:Above main FAI Battery Voltage with NC Power. 27.31 wlo A/C Power 7424 Date: 8/13119 Owner/Rep: Phone#: Date: Inspector Mat Machado Phone#: 530-362-2609 Date:2/18/22 Ali V IAA Oh( ALARM AND DETECTION REPORT Page 2 of 5 Property Site: Nord Country School operational *Tested This Equipment I Total* I Report I Yes NIA !Note* 4. Remote Annunciators 5. Zones 6. Manual Stations(Pull) Hardwire 11 11 11 Addressable 7. Detectors Photoelectric 23 23 23 Ionization Heats I Fixed or R of R 30 30 30 Flame Dud(See#15) 1 1 1 8. Hom I Strobe 7 7 7 Strobe Only 8 8 8 Bell Speakers 3 3 3 Horn 13 13 13 Speaker strobe 7 7 7 9. Wed laves a®! 1 1 X 10. Automatic Door Release 11. Water Flow switches Did WIF Ring Outside Bell? Did W/F Activate Alarm Panel? 12_ Tamper Switches 1 1 X 13. PIV OS&Y 14. 15. Did test of Duct Detectors shut down air handling units? 16. Did the Monitoring Center(Fire Dept,Central Station, Lease Line)receive signal? 17. Is system reset for normal conditions? 18. 1s system restored to operational service? 19. Have Proper Authonties(see#1)been notified system is back in service? List Proper Authorities:Central Station 20. Indicate%of equipment tested this report 25% 50% 75% 100% 21. Indicate%of equipment tested YTD 259E 50% 799E 100% Comments for any"no"answers or explanations(Note#): 4/1 P/99 00( ALARM AND DETECTION REPORT Page 3 of 5 Property Site: Nord Country School DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL r PS Room 9 X 33 11-1 PS Room 10 X 33 12-1 PS Cafeteria west X 5 1 PS Outside office X 3 1 PS Room 2 X 3 2 PS Room 3 X 4 1 PS Room 4 X 4 2 I PS Room 5 X 4 8 PS Room 6 X 33 01 PS Room 7 X 33 4-1 PS Room 8 X 33 9-1 PSD Room 5 ELD office X 4 3 PSD Room 5 ESP office X 4 4 PSD Room 5 classroom X 4 5 PSD Room 6 X 33 2-1 PSD Room 6 X 33 2-2 PSD Room 7 X 33 5-1 PSD Room 7 X 33 5-2 PSD Room 8 X 33 8-1 PSD Room 8 X 33 8-2 PSD Room 9 X 33 10-1 PSD Room 9 X 33 10-2 PSD Room 10 X 33 13-1 PSD Room 10 X 33 13-2 PSD Room 11 X 33 1 7-1 PSD Room 11 X 33 1 7-4 PSD Room 12 X 33 7-5 PSD Room 12 X 33 7-8 PSD Boys restroom X 33 17-9/\ of M 0 lrfn 1/ ALARM AND DETECTION REPORT Nord Country School Page 4 of 5 DEVICE etczone °f DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# mama s PSD Staff restroom X 33 7-19 PSD Girls restroom X 33 7-21 PSD Room 13 X 33 7-11 PSD Room 13 X 33 7-14 PSD Room 14 X 33 7-15 PSD Room 14 X 33 7-18 HD AC Room 5 X 4 6 HD AC Room 5 X 4 7 HD AC Room 6 X 33 3-1 HD AC Room 6 X 33 3-2 HD AC Room 7 X 33 6-1 HD AC Room 7 X 33 6-2 HD AC Room 8 X 33 8-1 HD AC Room 8 X 33 8-2 HD AC Room 9 X 33 10-3 HD AC Room 9 X 33 10-4 HD AC Room 10 X 33 14-1 HD AC Room 10 X 33 14-2 HD AC Room 11 X 33 7-2 HD AC Room 11 X 33 7-3 HD AC Room 12 X 33 7-6 HD AC Room 12 X 33 7-7 HD AC Room 13 X 33 7-12 HD AC Room 13 X 33 7-13 HD AC Room 14 X 33 7-16 HD AC Room 14 X 33 7-17 HD Boys restroom portable at MP X 6 4 HD Girls restroom portable at MP X 6 2 HD Unisex restroom portable at MP X 6 3 HD AC restroom portable at MP X 6 1 HD AC restroom portable at MP X 6 5 HD AC boys restroom X 33 7-10 n 14ninn DX ALARM AND DETECTION REPORT Nord Country School Page 5 of DEVICE Zone DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL • HD AC Girls restroom X 33 7-22 HD AC staff restroom X 33 7-20 HD Restroom plumbing Chase X 33 7-23 HD Restroom plumbing Chase X 33 7-24 TS Water tank shut off valve tamper switch X 33 21 FV Water tank low level X 33 20 DD HVAC outside MP X 33 19 LEGEND P50—Photoelectric Smoke Detector BD—Beam Detector H—Horn V—Visual ISO—Iota80n Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch ADD—Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime W —Water Flow Switch IDD—len Duct Smoke Detector HT—Fired Temp Hest Detector CV—Clime Ward DH—Door Helder DHS—Door Holder&Smoke Detector FD—Flame Detector S—Speaker OSY—Outside Stem&Yoke Tamper Valve SFD—Sigral Siatim cnnkerImPctor R—Rnii AV—Audahle Muni GrV—Arta ir ator valve Cur-Elevator Curtains FRD-Fee Robldown Door SDC Smoke Detector&Door Holder Combo CO-Carbon Monoxide Detector FV---Water tank float valve NOTE# COMMENT 9/1 R/99 DX