INSPECTION & TESTING FORM
CALIF. STATE LICENSE # CIO-742781
ACO 849
AC0849
-2 Z
Time:
0
[Date:
Date of last service perfo/rmed:
Battery last replaced:/
/
SERVICE ORGANIZATION PROPERTY NAME (USER)
/
Name: Accu!arm Security Systems
Name: GRACE LUTHERAN CHURCH
Address: 2348 Baldwin Ave, Orovilie, CA 95960
Address: 150 FORD AVE. GRIDLEY, CA 95948
Representative:
Owner Contact: 530-846-4736
License No.:
/
Contact:
Telephone: (530) 53&0885
Telephone:
TYPE OF TRANSMISSION DIGITAL
SERVICE:
/
PANEL TYPE: HONEYWELL MODEL: 128FB
ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION
Quantity of Devices Installed
Quantity of Devices Tested
Type of Device
3
Pull Stations
Ion Detectors
Photo Detectors
Duct Detectors
Heat Detectors
Water Flow Switches
Supervisory Switches
Other (Specify)
Alarm verification is disabled: enabled:
/
Dry Cell
Lead- Acid
Nickel-Cadmium
ealed Lead- Acid /
Other (specify):
/ ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION
Quantity of Appliances Installed
Quantity of Appliances Tested
Type of Appliance
Bells
3
3
Horns E
Chimes
Strobes
Speakers
Other (specify):
SYSTEM POWER SUPPLIES
Primary ( Main): Nominal Voltage: i 2 D Amps: 20 Over Current Protection: Type:
Location (of Primary Panel Supply Board): Disconnecting Means Location:
Secondary (Stanby):
Storage Battery: Amp-Hr Rating / 6 Engine- driven generator dedicated to fire alarm system: Location of fuel storage:/
TYPE OF BATTERY/
(c) Emergency or standby system used as a backup to primary power supply, instead of using a Secondary power supply:/
Emergency system described in NFPA 70, Article 700
/
/ Legally required standby described in NFPA 70.Article 701
/ Optional standby system described in NFPA 70, Article 702, which meets the Performance requirements of Article 700 or 701
PRIOR TO ANY TESTING
NOTiFiCATiONS
Yes
No
Who
Time
Monitoring Entity
cc e
Sccu
Building Occupants
Building Management
/
Other (Specify)
AHJ Notified of
Any Impairments
SYSTEM TESTS AND INSPECTIONS
TYPE
VISUAL
FUNCTIONAL
COMMENTS
Control Unit
Lamps/LEDs
Fuses
/
Primary Power Supply
/
/
Trouble Signals
Disconnect Switches
Ground- Fault Monitoring
SECONDARY POWER
TYPE
VISUAL
FUNCTIONAL
COMMENTS
Battery Condition
Load Voltage
Discharge Test
Charger Test
Transient Suppressors
Remote Annunciators
Notification Appliances
Audible
Visible
Speakers
EMERGENCY COMMUNICATIONS EQUIPMENT
TYPE
VISUAL
FUNCTIONAL
COMMENTS
Phone Jacks
System Performance
TYPE
YES
NO
WHO
TIME
Building Management
30s
Monitoring Agency
/
Other (Specify)
Voice Clarity
COMBINATION SYSTEMS
TYPE:
VISUAL
FUNCTIONAL
COMMENTS
Carbon Monoxide Detector/System
(Specify)
Special Procedures:
Comments:
SUPERVISORY STATION MONITORING
TYPE
YES
NO
COMMENTS
Alarm Signal
Alarm Restoration
Trouble Signal
Trouble Signal Restoration
Supervisory Signal
Supervisory Signal Restoration
NOTIFICATION THAT TESTING IS COMPLETE
The Following did not operate correctly:
/-Cf±ö /
System was restored to normal operation: Date: // — /Time: 1 S
/
THIS TESTING WAS PERFORMED {N ACCORDANCE WiTfri APPLiCABLE NFPA STANDARDS
/