Loading...
HomeMy WebLinkAboutFAI20-0033 FA 2022ACCULARM SECURITY SYSTEMS 1-800-7-ACCULARM (7220852)  2348 Baldwin Avenue  Chico /  Oroville, CA 95966 Burglar & Fire Alarms (530) 895-0335  (530) 532-0385 ' www.accularm.com / Paradise (530) 872-5311 /Fax (530) 534-1889  742781 INSPECTION & TESTING FORM CALIF. STATE LICENSE # CIO-742781 ACO 849 AC0849  -2 Z Time: 0  [Date: Date of last service perfo/rmed: Battery last replaced:/      /   SERVICE ORGANIZATION PROPERTY NAME (USER) / Name: Accu!arm Security Systems Name: GRACE LUTHERAN CHURCH  Address: 2348 Baldwin Ave, Orovilie, CA 95960 Address: 150 FORD AVE. GRIDLEY, CA 95948  Representative: Owner Contact: 530-846-4736  License No.: / Contact:  Telephone: (530) 53&0885 Telephone:  TYPE OF TRANSMISSION DIGITAL SERVICE: / PANEL TYPE: HONEYWELL MODEL: 128FB ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity of Devices Installed Quantity of Devices Tested Type of Device   3 Pull Stations    Ion Detectors     Photo Detectors    Duct Detectors    Heat Detectors    Water Flow Switches    Supervisory Switches    Other (Specify)   Alarm verification is disabled: enabled: / Dry Cell  Lead- Acid   Nickel-Cadmium  ealed Lead- Acid /   Other (specify):    / ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION Quantity of Appliances Installed Quantity of Appliances Tested Type of Appliance    Bells  3 3 Horns E    Chimes    Strobes    Speakers    Other (specify):  SYSTEM POWER SUPPLIES Primary ( Main): Nominal Voltage: i 2 D Amps: 20 Over Current Protection: Type: Location (of Primary Panel Supply Board): Disconnecting Means Location: Secondary (Stanby): Storage Battery: Amp-Hr Rating / 6 Engine- driven generator dedicated to fire alarm system: Location of fuel storage:/ TYPE OF BATTERY/ (c) Emergency or standby system used as a backup to primary power supply, instead of using a Secondary power supply:/ Emergency system described in NFPA 70, Article 700 / / Legally required standby described in NFPA 70.Article 701 / Optional standby system described in NFPA 70, Article 702, which meets the Performance requirements of Article 700 or 701 PRIOR TO ANY TESTING NOTiFiCATiONS Yes No Who  Time  Monitoring Entity   cc e Sccu    Building Occupants       Building Management     /   Other (Specify)       AHJ Notified of Any Impairments       SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS  Control Unit     Lamps/LEDs     Fuses /    Primary Power Supply / /   Trouble Signals     Disconnect Switches     Ground- Fault Monitoring     SECONDARY POWER TYPE VISUAL FUNCTIONAL COMMENTS  Battery Condition     Load Voltage     Discharge Test     Charger Test     Transient Suppressors      Remote Annunciators     Notification Appliances     Audible     Visible     Speakers     EMERGENCY COMMUNICATIONS EQUIPMENT TYPE VISUAL FUNCTIONAL COMMENTS  Phone Jacks     System Performance     TYPE YES NO WHO TIME  Building Management   30s   Monitoring Agency   /    Other (Specify)      Voice Clarity     COMBINATION SYSTEMS TYPE: VISUAL FUNCTIONAL COMMENTS  Carbon Monoxide Detector/System (Specify)     Special Procedures:        Comments:        SUPERVISORY STATION MONITORING TYPE YES NO COMMENTS  Alarm Signal     Alarm Restoration     Trouble Signal     Trouble Signal Restoration     Supervisory Signal     Supervisory Signal Restoration     NOTIFICATION THAT TESTING IS COMPLETE The Following did not operate correctly: /-Cf±ö /         System was restored to normal operation: Date: // — /Time: 1 S / THIS TESTING WAS PERFORMED {N ACCORDANCE WiTfri APPLiCABLE NFPA STANDARDS /