HomeMy WebLinkAboutFAI15-0039 056-030-030 FS 2022 Inspection, Testing, and Maintenance Cover Sheet
NFPA25 as amended by CCR, Title 19
Property Information:
Name: Occupancy/Use:
Youth with a Mission Main Building 1y
Address: 15850 Richardson Springs Rd Construction Type: �4 ��gC",p0�l1
City: Chico No. Stories: 6 od�„ F
a
ZIP: 95973 Year Constructed: I/c\ %r,�
Contact: �t+ t'`'igF MPS'
Telephone:
Contractor Information: Number of System Risers
Name: Foothill Fire Protection, Inc. Copy sent to:
Address: 170 Erma Court ❑✓ Owner Date: 12-01-2022
City: Chico ❑J Fire AHJ Date: 12-01-2022
State: California ❑ Contractor Date:
NOTES:
Telephone:
(530)826-3013 1)For specific inspection,testing,and maintenance
CA License requirements and information,see NFPA 25,2011
#: 783132 edition as amended by California Code of
Job#: Regulations,Title 19,§901 to§906
27333774
Performed 2)Inspection items may be performed by the owner
by: Stephen Rampenthal in accordance with California Code of Regulations,
Title 19,§904.1(a)
Check box for each system inspected and enter the number of forms used for inspection.
Check boxes (Fail or Pass)to indicate status of inspected system at end of inspection.
Forms included with this Report Chapter Number of Forms NI' Pass
❑✓ Automatic Sprinkler System 5 4 ❑ ❑ ❑✓
❑ Standpipe and Hose System 6 0 ❑✓ ❑ ❑
❑ Private Water Supply System 7 0 ❑✓ ❑ ❑
❑ Fire Pump 8 0 Q ❑ ❑
❑ Water Storage Tank 9 0 Q ❑ ❑
n Water Spray System 10 0 ❑✓ ❑ ❑
❑ Foam Water Sprinkler System 11 0 ❑✓ ❑ ❑
❑ Water Mist System 12 0 0 ❑ ❑
Concerns that are Not Deficiencies(i.e. Non-Sprinklered Areas) ❑ Yes ❑./ No
*See"Deficiencies and Comments"section at end of each respective form.
Wet Pipe California Code of Regulations—Title 19 Quarterly and 2 of 4
Fire Sprinkler System Inspection,Testing and Maintenance Annual Report
Property Information o �4 f. Contractor or Licensed Owner Information
at:."`
Building Name: Youth with a Mission Main Building I7 fa Name: Foothill Fire Protection, Inc
Address: 15850 Richardson Springs Rd � Address: 170 Erma Court
EIO
City: Chico St: CA Zip:95928
City: Chico License#:783132 Phone: (530)826-3013
Contact Person: 0 SFM Job#: 27333774
Phone: ❑✓ CSLB C-16 Misc.
RiInformation
Riser Riser Main Drain Initial Residual Final Static
No. Location Diameter Diameter Static Pressure Pressure P,F,N/A
Pressure
1 South East Exterior Riser 2 2 75 60 75 P
❑ This building has more than 5 risers.See additional AES 2.9 form attached. Number of AES 2.9 forms attached:
5-Year INSPECTION,TESTING AND MAINTENANCE
Includes ALL Quarterly and Annual Inspections,Tests,and Maintenance
I= Inspection T=Test M =Maintenance P=Pass F=Fail N/A =Not Applicable
NFPA 25 CA
Item Description ed. Date iiii Comments Only P,F,N/A
Reference
1.1 I Control Valves—Identification Sign 13.3.1 12-01-2022 N/A P
1.2 I Control Valves—Inspection 13.3.2 12-01-2022 N/A P
1.3 I Waterflow Alarm Devices 5.2.5 12-01-2022 N/A P
1.4 I Supervisory Devices 5.2.5 12-01-2022 N/A P
1.5 I Gauges(Wet Pipe Systems) 5.2.4.1 12-01-2022 N/A P
1.6 I Hydraulic Design Information Sign 5.2.6 12 01 2022 N/A P
(For hydraulically designed systems)
1.7 I Enter Water Supply Pressure Below Riser Check 5.2.4.1 12-01-2022 psi N/A
1.8 I Enter Water Supply Pressure Above Riser Check 5.2.4.1 12-01-2022 psi N/A
1.9 I Pressure Readings Acceptable 5.2.4.1 12-01-2022 N/A P
General Information Sign
1.10 I (not required for system prior to 2007 Edition NFPA 5.2.8 12-01-2022 N/A N/A
13)
1.11 I Heat Tape 5.2.7 12-01-2022 N/A N/A
1.12 I Spare Sprinklers 5.2.1.4 12-01-2022 N/A P
1.13 I Fire Department Connections 13.7 12-01-2022 N/A P
1.14 I Alarm Valves—Exterior Inspection 13.4.1 12-01-2022 N/A P
1.15 I Pressure Reducing Valves 13.5.1.1 12-01-2022 N/A P
1.16 I Backflow Preventers 13.6.1 12 01 N/A N/A
2022
Wet Pipe California Code of Regulations -Title 19 5 Year 3 of 4
Fire Sprinkler System Inspection,Testing, and Maintenance Report
Property Information Contractor or Licensed Owner Information
Building Name:Youth with a Mission Main Building , .,k-y v Name:
Address: 15850 Richardson Springs Rd Job#:27333774
City: Chico
ANNUAL INSPECTION,TESTING,AND MAINTENANCE
Include ALL Quarterly Inspections(See Previous Page)
I=Inspection T=Test M=Maintenance P=Pass F=Fail N/A =Not Applicable
Item Description It
NFPA 25 CA Date Comments Only P,F,N/A
ed.Reference
1.17 I Small Hose Connections-Hose Valve* 5.1.6, 13.5.2 12-01-2022 N/A N/A
13.5.5.1
1.18 I PRV—Fire Sprinkler Systems 13.5.1.1 12-01-2022 N/A N/A
1.19 I Buildings(Freeze Protection) 4.1.1.1 12-01-2022 Owner's Responsibility P
1.20 I Sprinklers 5.2.1 12-01-2022 N/A P
1.21 I Sprinklers-Accessible Concealed Space 5.2.1.1.6 12-01-2022 N/A P
1.22 I Pipe and Fittings 5.2.2 12-01-2022 N/A P
1.23 I Pipe and Fittings-Accessible Concealed Space 5.2.2.3 12-01-2022 N/A P
1.24 I Hangers 5.2.3 12-01-2022 N/A P
1.25 I Hangers-Accessible Concealed Space 5.2.3.3 12-01-2022 N/A P
1.26 I Seismic Braces 5.2.3 12-01-2022 N/A P
1.27 I Seismic Braces-Accessible Concealed Space 5.2.3.3 12-01-2022 N/A P
1.28 I Unsprinklered Areas CFC 901.4 12-01-2022 ❑Yes ONo
2.1 T Field Service Test Required 5.3.1 12-01-2022 If REQUIRED,Enter"F"until N/A
Send Report to Fire Code Official results are returned from Lab
2 2 T Recalled Sprinklers Title 19 12-01-2022 N/A P
If not present=Pass; If present=Fail 904.1(c)
2.3 T Water Flow Alarm Devices 5.3.3 12-01-2022 30 sec P
90 secs max. Enter time 13.2.6
2.4 T Main Drain Test 13.2.5 12-01-2022 N/A P
(Enter data on Page 1 of this form) 13.3.3.4
2.5 T Control Valve-Position 13.3.3.2 12-01-2022 N/A N/A
2.6 T Control Valve—Operation 13.3.3.1 12-01-2022 N/A P
2.7 T Supervisory Devices 13.3.3.5 12-01-2022 N/A P
2.8 T Backflow Preventer Assemblies 13.6.2 12-01-2022 N/A N/A
2 9 T Small Hose Connections* 13.5.2.3 12-01-2022 N/A N/A
w/PRV Hose Valves—Partial Flow Test 13.5.3.3
2.10 T PRV—Fire Sprinkler Systems 13.5.1.3 12-01-2022 N/A N/A
2.11 T Pressure Gauges-Calibration 5.3.2 12-01-2022 N/A P
2.12 T Small Hose Connections* 13.5.6.2.2 12-01-2022 N/A N/A
*Small hose connections are hose valves and optional hose supplied by the fire sprinkler system.They do not include Class I, II,or III standpipe
systems.
Wet Pipe California Code of Regulations -Title 19 Quarterly and 4 of 4
Fire Sprinkler System inspection,Testing,and Maintenance Annual Report
Property Information `off Alt Contractor or Licensed Owner Information
Budding Youth with a Mission Main Building ;�[ 5,0 Name: Foothill Fire Protection,Inc
Name: .
I Address: 15850 Richardson Springs Rd tj Ji 4 I Job# 27333774
I City: Chico \, F---
ANNUAL INSPECTION,TESTING,AND MAINTENANCE
Include ALL Quarterly Inspections(See Previous Page)
I=Inspection T=Test M=Maintenance P=Pass F=Fail N/A=Not Applicable
Item escrip ion dFReference a e P,F,N/A
3.1 M Check Valves-Internal inspection 13.4.2 12-01-2022 N/A N/A
3.2 M Control Valves 13.3.4 12-01-2022 N/A P
3.3 M FDC-Backflush 14.3.2.3 12-01-2022 N/A P
14.3.2.4
Internal Pipe Inspection
3.4 M If"Yes"-See Deficiencies and Comments Section for 14.2 12-01-2022 yes
Results.
Obstruction Investigation Required.
3.5 M If"Yes"-See Deficiencies and Comments Section for 14.3 12-01-2022 no
Results.
3.6 M System Returned to Service 4.5.3 12-01-2022 yes
D = Deficienc C= Comment Indicate t •e
Deficiencies and Comments
Indicate all equipment,devices and parts that were repaired or replaced
❑ Check here if additional Deficiencies and Comments are listed on Form AES 9. Number attached:
❑ See Correction Form AES 10 for corrected deficiencies. Number attached:
I hereby certify that the fire protection equipment listed above has been fully inspected,tested,and maintained on this date
by
the company indicated above, in accordance with CCR,Title 19, Sections 901 to 906 and that the equipment is fully operable
except as noted in the"Deficiencies and Comments"section of this form.
Print Name I Stephen Rampenthal
Signature Date 12-01-2022