RFI23-0203 Hoag Residence Plan for Setback Determination
60"x60" TUBW/ TILE SURROUND TOILET1.28G/FL WHGARAGE DOOR OPENER SHALL BE LISTED W/ U.L.325; CRC SEC 309.4 WITH BATTERYBACK-UP THAT FUNCTIONS DURING ELECTRICALOUTAGE. HEALTH & SAFETY CODE 19892GARAGE DOOR OPENER SHALL BE LISTED W/ U.L.325; CRC SEC 309.4 WITH BATTERYBACK-UP THAT FUNCTIONS DURING ELECTRICALOUTAGE. HEALTH & SAFETY CODE 19892ELECTRICDRYERVENT TO O.S. AIRWASHER TUB & SHOWERW/ +72" TILE SURROUND& S. G. ENCLOSURE1.8 GPM @ 80 PSI2"x8" BACK'G BETWEEN32" & 39 1/4" PLUSWITHIN 6" OF TUB TOP TOILET 1.28G/FL 2"x8" BACKING BETWEEN32"&39 1/4" TOILET 1.28G/FLDOUBLE SINK1.8 GPM@80PSI4040RS 2020AW 4040RS 28682868 2868 2868 2630LS 30801808018080 8068 3030LS 3068 6040RS4020LS6040LS6040LS6040LS 70806040LS60682868286828686068406828682868306830686040LS 9'-6"9'-6"9'-6"9'-6"3'-0"2'-4"2'-4"2'-0" 5'-4"4'-4"4'-0"19'-0"4'-0"19'-0"4'-0"7'-1"7'-7"8'-0"12'-8"2'-8"3'-8" 9'-8"50'-0"14'-8"23'-4"3'-8"15'-8"3'-0"10'-0"14'-2"18'-8"6'-0"5'-0"24'-6"24'-2"24'-8"29'-6"2'-0"2'-0"7'-7"7'-1"6'-3"5'-9"3'-10"2'-6"6'-3"6'-5"9'-4"2'-8"12'-8"8'-0"14'-8"12'-0"6'-4"12'-8"78'-4"2'-0"2'-0"2'-0"2'-4" 12'-4"4'-0"25'-4"36'-0"10'-10"4'-4"8'-6" 101'-4"78'-4"101'-4"SAFETY GLASSSAFETY GLASSTOILETRM.SEATSHOWER S.G. ENCL.S.G. ENCL. BARRIER FREEBARRIER FREE DRAIN +2" BELOW FLOOR. CPC 408.5. TILETILE +72" W.I. CLOSET W.I. CLOSET MASTER BATH PROVIDE KEYLESSPROVIDE KEYLESS ENTRY TOUCH PADENTRY TOUCH PAD CONCRETE SLAB FLOOR SHEETROCK WALLS & CLG. SEE NOTESNOTES, GARAGE, INCLUDING GARAGE TO DWELLING DOORS. GAS WATER HEATER NOTES:GAS WATER HEATER NOTES: PROVIDE 30"x30"x7' TALL SPACE SUITABLE FOR FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH). SEE NOTES, WATER HEATER.50gWHMASTER BEDROOM SAFETY GLASSSAFETY GLASS LAUNDRYSINK UPPER ENERGY STORAGE SYSTEMS (ESS) READYENERGY STORAGE SYSTEMS (ESS) READY. CEnC 150.0.S. ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE (CEC): 1.) AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A.)ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS & A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR B.)A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN ONE INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOADSUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITSCIRCUITS..” 2.) A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED & HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, & AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. 3.) THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. 4.) SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD & THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. HEAT PUMP SPACE HEATER READY:HEAT PUMP SPACE HEATER READY: CEnC 150.0.T. SYSTEMS USING GAS OR PROPANE FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.)A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE FURNACE & ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. 2.)THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE HEAT PUMP SPACE HEATER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USEFOR FUTURE 240V USE..” ELECTRIC COOKTOP READYELECTRIC COOKTOP READY:: CEnC150.0.U. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.)A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE COOKTOP & ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC. 2.)THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USEFOR FUTURE 240V USE..” ELECTRIC CLOTHES DRYER READYELECTRIC CLOTHES DRYER READY:: CEnC 150.0.V. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.)A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION & ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC. 2.)THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USEFOR FUTURE 240V USE.” WATER HEATING SYSTEMWATER HEATING SYSTEM: : CEnC 150.0.N. 1.) SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT LEAST 30” BY 30” WIDE AND 7’ TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH) BY MEETING EITHER A OR B BELOW. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC: A.) IF THE DESIGNATED SPACE IS WITHIN 3’ FROM THE WATER HEATER, THEN THIS SPACE SHALL INCLUDE THE FOLLOWING: I.) A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3’ FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS; AND II). BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD “SPARE” AND BE ELECTRICALLY ISOLATED; AND III). A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH CIRCUIT IN A ABOVE AND LABELED WITH THE WORDS “FUTURE 240V USE”; AND IV). A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, & ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. B.) IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER, THEN THIS SPACE SHALL INCLUDE THE FOLLOWING: I.) A DEDICATED 240 VOLT BRANCH CIRCUIT SHALL BE INSTALLED WITHIN 3’ FROM THE DESIGNATED SPACE. THE BRANCH CIRCUIT SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY”; AND II.) THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE HPWH INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE”; AND III.) EITHER A DEDICATED COLD WATER SUPPLY, OR THE COLD WATER SUPPLY SHALL PASS THROUGH THE DESIGNATED HPWH LOCATION JUST BEFORE REACHING THE GAS OR PROPANE WATER HEATER; AND IV). THE HOT WATER SUPPLY PIPE COMING OUT OF THE GAS OR PROPANE WATER HEATER SHALL BE ROUTED FIRST THROUGH THE DESIGNATED HPWH LOCATION BEFORE SERVING ANY FIXTURES; AND V). THE HOT AND COLD WATER PIPING AT THE DESIGNATED HPWH LOCATION SHALL BE EXPOSED AND READILY ACCESSIBLE FOR FUTURE INSTALLATION OF AN HPWH; AND VI.) A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, & ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. BEDROOM #2 BEDROOM #3CLOSETHALL TOP AT 8'-0"TOP AT 8'-0"BATH HALFBATH PANTRY CLOSET HALL LAUNDRY HALL MUD ROOM UPPER GARAGE - 4 CAR COVERED PORCH COVERED PORCH SEE CPC, SECTION 909. FLOOR VERTICAL FIXTURE DRAIN 2" 1 1/2" NEAREST WALL 1 1/2" VENT THROUGH ROOF OR CONNECT TO OTHER VENTS 1/4" / FOOT GRADE 1 1/2" FOOT VENT LESS THAN 20' IN LENGTHVERTICAL FIXTURE VENT 2" A B A & B ARE WYE-BRANCH FITTINGS COUNTER TOP ISLAND VENTING SCALE: 1/4" = 1'-0" CLEANOUT 3/16/2023 1/4 BEND 1/8 BENDSINK CLEANOUT NO OTHER FIXTURE DRAIN MAY BE CONNECTED TO THE 2" DRAIN LINE UPSTREAM OF THE POINT WHERE THE ISLAND SINK RETURNED VENT CONNECTS TO THE HORIZONTAL WASTE LINE. FIXTURE DRAINS FROM OTHER FIXTURES MAY CONNECT DOWNSTREAM FROM THE RETURNED VENT TIE-IN TO THE 2" SINK DRAIN. LONG TURN 1/4 BEND 1 THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THIS ENGINEER FOR EACH UNIQUE BUILD. SHOWN 4/14/2023 SCALE: DATE: THESE PLANS HAVE BEEN REVIEWED ONLY FOR COMPLIANCE WITH ATTACHED STRUCTURAL CALCULATIONS.A THREE BEDROOM RESIDENCE for:ARCH E1 30"x42"NICK HOAG - CONTRACTORNICK HOAGNICK HOAG812 WESTGATE COURT, CHICO, CALIFORNIA 95926ASSESSORS PARCEL # 042 - 650 - 012LIVABLE: XXXX SqFt TOTALXXXX SqFt TOTAL GARAGE: XXXX SqFt TOTALXXXX SqFt TOTAL COVERED PATIO: XXX SqFt FRONT XXX SqFt REAR XXX SqFt TOTALXXX SqFt TOTAL NICK HOAG GENERAL CONTRACTOR (530) 521-2563 NHoag1@Yahoo.com © COPYRIGHT 2023 SHEET XXXX SUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com 1 STORY WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CANNOT GUARANTEEAGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net C:/Users/Lynn/Documents/Chief X15 Plans/Nick Hoag/Hoag Residence.layoutOWNER: NICK HOAG(530) 521-2563 CELLEMAIL ADDRESS: NHoag1@Yahoo.com 2023NICK HOAG - GENERAL CONTRACTOR(530) 521-2563 CELLEMAIL ADDRESS: NHoag1@Yahoo.com PLPLPLPL72.00'N0° 0' 45"WPLPLPLPLPLPL132.47' N89° 59' 15"E PLPLPLPLPLPLPLPLPLPLPL 31.74'S0° 2' 7"EPLPL106.31'S19° 41' 11"WPLPLPLPLPLPLPLPLPL4 0 .8 1 'r =5 0 .0 0 'PLPLPL1 7 .4 5 'r =2 0 .0 0 'PL9.93' N88° 46' 27"W PL 17.45' r=20.00'PL1 4.1 7' r= 5 0.0 0'PL18.02'r=20.00'PLC / LC / LC / LC / LC / LC / LC / LC / LC / LC / LC / LC / LEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTP.U.E. P.U.E. P.U.E.P.U.E.P.U.E. P .U.E .P.U .E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.P.U.E.EASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTEASEMENTP.U.E. PLPLPLPLPLEG SSEWER WWH50gWH S.B .L.S .B .L .S.B.L. 3'-0" 3'-0" 25'-0"10'-0"10'-0"10'-6"5'-2" 6' P.U.E. & PVT. STORM DRAIN EASEMENT C / L W E S T G A T E C O U R TSUBJECT CHICO SUBJECT 6 THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THIS ENGINEER FOR EACH UNIQUE BUILD. SHOWN 4/14/2023 SCALE: DATE: THESE PLANS HAVE BEEN REVIEWED ONLY FOR COMPLIANCE WITH ATTACHED STRUCTURAL CALCULATIONS.A THREE BEDROOM RESIDENCE for:ARCH E1 30"x42"NICK HOAG - CONTRACTORNICK HOAGNICK HOAG812 WESTGATE COURT, CHICO, CALIFORNIA 95926ASSESSORS PARCEL # 042 - 650 - 012LIVABLE: XXXX SqFt TOTALXXXX SqFt TOTAL GARAGE: XXXX SqFt TOTALXXXX SqFt TOTAL COVERED PATIO: XXX SqFt FRONT XXX SqFt REAR XXX SqFt TOTALXXX SqFt TOTAL NICK HOAG GENERAL CONTRACTOR (530) 521-2563 NHoag1@Yahoo.com © COPYRIGHT 2023 SHEET XXXX SUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com 1 STORY WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CANNOT GUARANTEEAGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net C:/Users/Lynn/Documents/Chief X15 Plans/Nick Hoag/Hoag Residence.layoutOWNER: NICK HOAG(530) 521-2563 CELLEMAIL ADDRESS: NHoag1@Yahoo.com 2023NICK HOAG - GENERAL CONTRACTOR(530) 521-2563 CELLEMAIL ADDRESS: NHoag1@Yahoo.com