HomeMy WebLinkAboutFAI19-0007 CF FA 2022 1-8O0-7-ACCU LAR LARM 1T TEMS (722-2852) Chico 2348 Baldwin Avenue Oroville, CA 95966 Burglar & Fire Alarms (530) 895-0885 (530) 532-0885 •www.accularm.com • Paradise (530) 872-5311 Fax (530) 534-1889 742781 AC0849 INSPECTION & TESTING FORM CALIF. STATE LICENSE # C10-742781 ACO 849 Date: Ft.__j 2. I Time: to 0 0 SERVICE ORGANIZATION PROPERTY NAME (USER) Name: Accularm Security Systems I Name: Pizza Round Up Address: 2348 Baldwin Ave, Oroville, CA 95966 Address: 2 B St. Biggs, CA Representative: Owner Contact: Kim Hobbs License No.: Contact: Telephone: (530) 532-0885 Telephone: 530-701-0828 TYPE OF TRANSMISSION IS DIGITAL SERVICE: Weekly Monthly Quarterly I Semi-annually X Annually Other (Specify): PANEL TYPE: Lc, X, MODEL: Date of last service performed: Battery last replaced: 4/29/19 NFPA 72(P. OF ) ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity of Devices Installed I Quantity of Devices Tested I Type of Device Pull Stations Ion Detectors ( I Photo Detectors Duct Detectors Heat Detectors ( Water Flow Switches r I I Supervisory Switches Other (Specify) Alarm verification is disabled: enabled: ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION Quantity of Appliances Installed Quantity of Appliances Tested Type of Appliance ( Bells Horns Chimes Strobes Speakers Other(specify): SYSTEM POWER SUPPLIES (a) Primary ( Main): Nominal Voltage: /L' Amps: 2 C9 Over Current Protection: Type: l C 4 / Amps: _ Location (of Primary Panel Supply Board): orictC . Disconnecting Means Location: (b) Secondary (Stanby): Storage Battery: Amp-Hr Rating Engine- driven generator dedicated to fire alarm system: Location of fuel storage: TYPE OF BATTERY Dry Cell Lead- Acid Nickel-Cadmium K. I Sealed Lead- Acid Other (specify): NFPA 72(P. OF ) (c) Emergency or standby system used as a backup to primary power supply, instead of using a Secondary power supply: Emergency system described in NFPA 70, Article 700 Legally required standby described in NFPA 70.Article 701 Optional standby system described in NFPA 70, Article 702, which meets the Performance requirements of Article 700 or 701 PRIOR TO ANY TESTING NOTIFICATIONS Yes No Who Time Monitoring Entity ,/" Building Occupants ( , Building Management Other (Specify) AHJ Notified of Any Impairments SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS Control Unit Lamps/LEDs A Fuses Primary Power Supply Trouble Signals Disconnect Switches Ground- Fault Monitoring SECONDARY POWER TYPE VISUAL FUNCTIONAL COMMENTS Battery Condition S Load Voltage Discharge Test Charger Test Transient Suppressors Remote Annunciators Notification Appliances Audible Visible Speakers NFPA 72(P. OF ) Voice Clarity EMERGENCY COMMUNICATIONS EQUIPMENT TYPE VISUAL FUNCTIONAL COMMENTS Phone Jacks System Performance COMBINATION SYSTEMS TYPE: VISUAL FUNCTIONAL COMMENTS Carbon Monoxide Detector/System (Specify) Special Procedures: Comments: SUPERVISORY STATION MONITORING TYPE YES NO COMMENTS Alarm Signal Alarm Restoration Trouble Signal Trouble Signal Restoration Supervisory Signal Supervisory Signal Restoration NOTIFICATION THAT TESTING IS COMPLETE TYPE YES LNO WHO TIME Building Management r-A Ai.� �4 Monitoring Agency Other (Specify) NFPA 72(P. OF ) The Following did not operate correctly: Fire:. 3 AT rc c e.f f‘ Th C;) C System was restored to normal operation: Date: /J I t7-- 2°21' Time: i THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS Name of Inspector: Date: Time: AjA,f- fr< 4,AA S7 /4 it- 0 - 2_012- (0', L4 Signaturb: 1 ,k NAme of Owner or RAresentative: Date: Time K.C‘01,04 rz- r,t7 Signatufe: 1(s f-) ./\/‘ P"\. NFPA 72(P. OF )