Loading...
HomeMy WebLinkAboutFAI19-0007 CF FS 5 YR 2022 Inspection, Testing, and Maintenance Cover Sheet NFPA25 as amended by CCR, Title 19 Property Information: riir Name: Pizza Roundup Occupancy/Use: Address: 2 B Street Construction Type: ��tiaf CAL/A-%1(E iz � ` 1) 10 City: Biggs No. Stories: 1 y I 1l( _, , ZIP: 95917 Year Constructed: 2002 f` ,% \ ��P s el Contact: Kim �„.4E _ .�, --- Telephone: Contractor Information: Number of System Risers Name: Foothill Fire Protection, Inc. Copy sent to: Address: 170 Erma Court IIIOwner Date: 09/28/22 City: Chico E Fire AHJ Date: 09/28/22 State: CA ❑Contractor Date: (530)826-3013 NOTES: Telephone: 1) For specific inspection,testing,and maintenance 783132 requirements and information,see NFPA 25,2011 CA License#: edition as amended by California Code of Regulations, Title 19, §901 to§906. Job#: 26309070 2)Inspection items may be performed by the owner in Performed b Stephen Rampenthal accordance with California Code of Regulations,Title 19, Y: §904.1(a) Check box for each system inspected and enter the number of forms used for inspection. Check boxes (Fail or Pass)to indicate status of inspected system at end of inspection. I Forms Included with Fail* Pass Hill, Ill ❑./ Automatic Sprinkler System 5 E ❑ ❑ Standpipe and Hose System 6 ❑ ❑ 1 ❑ ❑ Private Water Supply System 7 ❑ ❑ ❑ El Fire Pump 8 ❑ ❑ ❑ ❑ Water Storage Tank 9 ❑ ❑ ❑ ❑ Water Spray System 10 ❑ ❑ ❑ Foam Water Sprinkler System 11 ❑ 0 1 ❑ ❑ Water Mist System 12 0 ❑ 0 1 ❑ ❑Concerns that are Not Deficiencies(i.e. Non-Sprinklered Areas) ❑ Yes 1 El No *See "Deficiencies and Comments" section at end of each respective form. AES 1 September 3,2013 Wet Pipe California Code of Regulations -Title 19 5-Year 1 of 3 Fire Sprinkler System Inspection, Testing, and Maintenance Report of CA(`�� Property Information ( - 7fiQ '' Contractor or Licensed Owner Information Building Name is I Name Foothill Fire Protection, Inc. Pizza Roundup •4�'� 11 Address 170 Erma Court (Address 2 B Street ti.iliE.� _ City Chico St. CA Zip 95928 (License# 783132 (Phone(530)826-3013 City Biggs I 0 SFM (Job#26309070 Contact Person Kim I ❑ CSLB 'Misc. III i Riser Location Riser Main Drain Initial Static Residual Final Static P,F, N/A No. Diameter Diameter Pressure Pressure Pressure 1 Southwest exterior riser 4 2 60 30 60 P I I I I I I I I I I I I I I I I I I I I I I I I ❑ This building has more than 5 risers. See additional AES 2.9 form attached. Number of AES 2.9 forms attached: 5-Year INSPECTION, TESTING,AND MAINTENANCE Includes ALL Quarterly and Annual Inspections, Tests,and Maintenance Items =Inspection T=Test M=Maintenance P=Pass F=Fail N/A=Not Applicable NFPA 25 CA Item Description ed. Date Comments Only P, F, N/A Reference 1.1 I Control Valves-Identification Sign 13.3.1 09/28/22 P 1.2 I Control Valves-Inspection 13.3.2 09/28/22 P 1.3 I Waterflow Alarm Devices 5.2.5 09/28/22 P 1.4 I Supervisory Devices 5.2.5 09/28/22 P 1.5 I Gauges (Wet Pipe Systems) 5.2.4.1 09/28/22 F 1.6 I Hydraulic Design Information Sign 5.2.6 09/28/22 F (For Hydraulically Designed Systems) 1.7 I Enter Water Supply Pressure Below Riser Check 5.2.4.1 09/28/22 psi NA 1.8 I Enter Water Supply Pressure Above Riser Check 5.2.4.1 09/28/22 psi P 1.9 I Pressure Readings Acceptable 5.2.4.1 09/28/22 P 1.10 I General Information Sign 5.2.8 09/28/22 NA (Not Required for System Prior to 2007 Edition NFPA 13) 1.11 I Heat Tape 5.2.7 09/28/22 NA 1.12 I Spare Sprinklers 5.2.1.4 09/28/22 P 1.13 I Fire Department Connections 13.7 09/28/22 P 1.14 I Alarm Valves-Exterior Inspection 13.4.1 09/28/22 P 1.15 I Pressure Reducing Valves 13.5.1.1 09/28/22 P 1.16 I Backflow Preventers 13.6.1 09/28/22 NA Form AES 2.2 Sept.3,2013 Wet Pipe California Code of Regulations -Title 19 5 Year 2 of 3 Fire Sprinkler System Inspection, Testing, and Maintenance Report Property Information ``,,, Contractor or Licensed Owner Information ofc A(��it (Building Name Pizza Roundup I ;"{ )5;r Name Foothill Fire Protection, Inc. (Address 2 B Street 1 +'';\ Q�,� Job# 26309070 1 (city Biggs I `;. E Mp, ANNUAL INSPECTION, TESTING, AND MAINTENANCE Include ALL Quarterly Inspections(See AES 2.1) I =Inspection T =Test M=Maintenance P=Pass F=Fail N/A=Not Applicable NFPA 25 CA ed. Item Description Reference Date Comments Only P,F,N/A 1.17 I Small Hose Connections-Hose Valve* 5.1.6, 13.5.2 09/28/22 N/A 13.5.5.1 1.18 I PRV—Fire Sprinkler Systems 13.5.1.1 09/28/22 P 1.19 I Buildings (Freeze Protection) 4.1.1.1 09/28/22 Owner's Responsibility P 1.20 I Sprinklers 5.2.1 09/28/22 F 1.21 I Sprinklers-Accessible Concealed Space 5.2.1.1.6 09/28/22 P 1.22 I Pipe and Fittings 5.2.2 09/28/22 P 1.23 I Pipe and Fittings-Accessible Concealed Space 5.2.2.3 09/28/22 P 1.24 I Hangers 5.2.3 09/28/22 P 1.25 I Hangers-Accessible Concealed Space 5.2.3.3 09/28/22 P 1.26 I Seismic Braces 5.2.3 09/28/22 P 1.27 I Seismic Braces-Accessible Concealed Space 5.2.3.3 09/28/22 P 1.28 I Unsprinklered Areas CFC 901.4 09/28/22 Yes Q No 2.1 T Field Service Test Required 5.3.1 09/28/22 If REQUIRED, Enter'F'until F Send Report to Fire Code Official results are returned from Lab 2 2 T Recalled Sprinklers Title 19 09/28/22 P If not present=Pass; If present=Fail 904.1(c) 2.3 T Water Flow Alarm Devices 5.3.3 09/28/22 30 sec. F 90 secs max. Enter time 13.2.6 2.4 T Main Drain Test 13.2.5 09/28/22 P (Enter data on Page 1 of this form) 13.3.3.4 2.5 T Control Valve-Position 13.3.3.2 09/28/22 N/A 2.6 T Control Valve—Operation 13.3.3.1 09/28/22 P 2.7 T Supervisory Devices 13.3.3.5 09/28/22 P 2.8 T Backflow Preventer Assemblies 13.6.2 09/28/22 N/A 2 9 T Small Hose Connections* 13.5.2.3 09/28/22 N/A w/PRV Hose Valves—Partial Flow Test 13.5.3.3 2.10 T PRV—Fire Sprinkler Systems 13.5.1.3 09/28/22 N/A 2.11 T Pressure Gauges-Calibration 5.3.2 09/28/22 P 2.12 T Small Hose Connections* 13.5.6.2.2 09/28/22 N/A *Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III standpipe systems. Form AES 2.2 Sept.3,2013 Wet Pipe California Code of Regulations -Title 19 Year Fire Sprinkler System Inspection, Testing, and Maintenance epo 3 of 3 Property Information .....--of CaC,,�h Contractor or Licensed Owner Information I 45-/ 41I //P 'Building Name Pizza Roundup f o ,-. . v Name Foothill Fire Protection, Inc. (Address 2 B Street I'+,`�1 ' ‘,�Ij Job# 26309070 (City Biggs �� E mP � ANNUAL INSPECTION, TESTING, AND MAINTENANCE Include ALL Quarterly Inspections(See AES 2.1) I =Inspection T =Test M=Maintenance P=Pass F=Fail N/A=Not Applicable Item I I Description I N References Date Comments Only I P,F,N/A 3.1 I (Check Valves- Internal inspection I 13.4.2 I 09/28/22 I I N/A 3.2 I (Control Valves I 13.3.4 I 09/28/22 I I P 3.3 I IFDC Backflush I 14.3.2.4 I 09/28/22 I I P 3.4 I 'Internal Pipe Inspection See Deficiencies and I 14.2 I 09/28/22 I ❑✓ Yes IP Comments Section for Results. ri No 3.5 I I Obstruction Investigation Required. If"Yes", See I 14.3 I 09/28/22 I 1N/A Deficiencies and Comments Section for Results 3.6 I (System Returned to Service I 4.5.3 I 09/28/22 I III Nos I P D=Deficiency C=Comment (Indicate type) Item I Date I Riser I D I C I Deficiencies and Comments Indicate all equipment,devices and parts that were repaired or replaced FAILED ITEMS THAT SHALL BE CORRECTED FOR PASSING REPORT: 1.5 9/28/22 1 x (1) Outdated gauge(2015) 1.6 9/28/22 1 X Missing hydraulic design information Sign. 1.20 9/28/22 1 X (7) Sprinklers loaded/damaged with grease in kitchen CH,QR, 155, CH-401 1.20 9/28/22 1 X Dry pendant sprinklers dated (2003) (6) Side wall CH,QR, 200 TY-3336, (1) CH,SR 200 Pendant 2.1 9/28/22 1 X Field service test required sprinklers dated 2001/2002: Brass QR,200 Uprights, CH,QR,155 CH-401 2.3 9/28/22 1 X Panel received a signal at 30 sec, no signal from bell during inspection. NOTES: Notes 9/28/22 1 X key pad would lock up during testing had to power system down to do full rest. ❑Check here if additional Deficiencies and Comments are listed on Form AES 9. Number attached: ❑ See Correction Form AES 10 for corrected deficiencies. Number attached: I hereby certify that the fire protection equipment listed above has been fully inspected, tested,and maintained on this date by the company indicated above,in accordance with CCR, Title 19,Sections 901 to 906 and that the equipment is fully operable except as noted in the"Deficiencies and Comments"section of this form. Print Name I Stephen Rampenthal Signature I Date 09/28/22 Form AES 2.2 Sept.3,2013