Loading...
HomeMy WebLinkAboutFAI20-0025 010-210-026 CF FA 2023-08-18 Gridley-High-School Fire Alarm and Life Safety System Inspection Certificate For Gridley High School 300 East Spruce Street Gridley, CA 95948 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Aug 18, 2023 Building: Gridley High School Company:Hue&Cry,Inc. Contact:Jordan Reeves Contact: Chyna Reed Title: Superintendent Title:Inspector Fire Alarm Testing Report Executive Summary Generated by:BuildingReports.com Building Information Building: Gridley High School Contact: Jordan Reeves Address: 300 East Spruce Street Phone: 1-530-846-4721 Address: Fax: City/State/ZIP Code: Gridley, CA 95948 Mobile: Country: United States of America Email:jreeves@gusd.org Inspection Performed By Company: Hue&Cry, Inc. Inspector: Chyna Reed Address: 1751 Bruce Drive Phone: 530-356-7007 Address: Fax: City/State/ZIP Code:Anderson, California 96007 Mobile: Country: United States of America Email: c.reed@hueandcry.com System Control Unit Manufacturer: Fire-Lite Inspection Date: 08/18/2023 IDC Style: B Model Number: MS-10US Install Date: 07/21/2010 SLC Style: Software Version: Version Date: 07/21/2010 NAC Style: Y Location: Office Conference Room Current Protection: Breaker Disconnect Location: Office Conference Room Type: Breaker Hue&Cry,Inc. Page 2 of 12 Download Date:08/21/2023 Executive Summary Inspection Summary Total Items Serviced Passed Failed/Other Category: Qty % Qty % Qty % Qty % Control 8 16.33% 8 100.00% 8 100.00% 0 0.00% Indicating 19 38.78% 19 100.00% 11 57.89% 8 42.11% Initiating 22 44.90% 22 100.00% 17 77.27% 5 22.73% Totals 49 100% 49 100.00% 36 73.47% 13 26.53% Certification Company: Hue&Cry, Inc. Building: Gridley High School Inspector: Chyna Reed Contact: Jordan Reeves Signed: Aug 18, 2023 Signed:Aug 18, 2023 Hue&Cry,Inc. Page 3 of 12 Download Date:08/21/2023 Executive Summary Discrepancy Report Generated by:BuildingReports.com Building: Gridley High School Control Panel: 1 - Fire-Lite MS-10US The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience.Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. Device Type Manufacturer ModelNumber Date Qty Items listed for Recall or Replacement/Upgrade Pull Station Fire-Lite BG-10 04/01/2013 1 ScaniD Location Problem Address Reference Indicating Horn 2 13975291 400 Wing West Side Failed 1 NFPA72 14.2.2.2.2 Annunciation 1 13975997 Boys Locker Room Special Note 1 NFPA72 14.2.2.2.2 1 13975285 Floral shop Special Note 1 NFPA72 14.2.2.2.2 1 13975993 Girls Locker Room Special Note 1 NFPA72 14.2.2.2.2 1 13975995 Outside Locker Room North Special Note 1 NFPA72 14.2.2.2.2 1 13975283 Wood Shop Special Note 1 NFPA72 14.2.2.2.2 1 13975272 portable 603 Special Note 1 NFPA72 14.2.2.2.2 Horn/Strobe 1 13975287 N/E Portable Special Note 1 NFPA72 14.2.2.2.2 Initiating Pull Station 1 13975996 Boys Locker Room Special Note 1 NFPA72 14.2.2.2.2 1 60670342 Floral shop Special Note 1 NFPA72 14.2.2.2.2 1 13975994 Girls Locker Room Special Note 1 NFPA72 14.2.2.2.2 1 13975288 N/E Portable Room 603 Special Note 1 NFPA72 14.2.2.2.2 1 13975284 Wood Shop Special Note 1 NFPA72 14.2.2.2.2 Code References NFPA72 14.2.2.2.2 System deficiencies shall be corrected. Hue&Cry,Inc. Page 4 of 12 Download Date:08/21/2023 Discrepancy Report Proposed Solutions Report Generated by:BuildingReports.com Building: Gridley High School Control Panel: 1 - Fire-Lite MS-10US The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report.Items listed as T/M are available for repair on a Time and Materials basis. ScaniD Location Solution Model# Cost Fix Indicating Horn 13975291 400 Wing West Side Investigate SC806A1004 T/M ❑ 13975997 Boys Locker Room See notes 4040 T/M ❑ /recommendations 13975285 Floral shop See notes SC806A1004 T/M ❑ /recommendations 13975993 Girls Locker Room See notes 4040 T/M ❑ /recommendations 13975995 Outside Locker Room North See notes 31T-115 T/M ❑ /recommendations 13975283 Wood Shop See notes SC806A1004 T/M ❑ /recommendations 13975272 portable 603 See notes MT-24R T/M ❑ /recommendations Horn/Strobe 13975287 N/E Portable See notes NS-24MCW T/M ❑ /recommendations Initiating Pull Station 13975996 Boys Locker Room See notes 4251-1 125v T/M ❑ /recommendations 60670342 Floral shop See notes S46A1045 T/M ❑ /recommendations 13975994 Girls Locker Room See notes 4251-1 125v T/M ❑ /recommendations 13975288 N/E Portable Room 603 See notes 2099-9101 T/M ❑ /recommendations 13975284 Wood Shop See notes S46A1045 T/M ❑ /recommendations PO#: (none) T/M Hue&Cry,Inc. Page 5 of 12 Download Date:08/21/2023 Proposed Solutions Report Notes & Recommendations Generated by:BuildingReports.com Building: Gridley High School The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection.Notes are grouped by Category. General Note Pull station &Horns in the 600, 700&locker room buildings are disconnected due to construction Horn 400 W Wing did not sound Hue&Cry,Inc. Page 6 of 12 Download Date:08/21/2023 Notes&Recommendations Inspection & Testing Generated by:BuildingReports.com Building: Gridley High School Control Panel: 1 - Fire-Lite MS-10US The Inspection& Testing section lists all of the items inspected in your building.Items are grouped by Passed or Failed/Other.Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. Device Type Location Service Time Date Passed Control Battery 10th Below Connector Cell Room 211 Annual 8:19:54 AM 08/18/2023 Power Supply Battery FACP Annual 8:14:48 AM 08/18/2023 Battery FACP Left Batt Annual 8:13:21 AM 08/18/2023 Battery Room 211 Power Supply Annual 8:19:45 AM 08/18/2023 Control Panel Office Conference Room Annual 8:44:56 AM 08/18/2023 Disconnect Room 211 #14A Annual 8:24:15 AM 08/18/2023 Disconnect Staff Break Room Hall -C/B A2#2 Annual 9:53:21 AM 08/18/2023 Power Supply Room 211 above Ceiling Tile Annual 8:44:44 AM 08/18/2023 Indicating Bell Office Hall Annual 9:53:24 AM 08/18/2023 Horn 200 Wing East Annual 9:51:17 AM 08/18/2023 Horn 200 Wing West Annual 9:51:20 AM 08/18/2023 Horn 300 Wing Annual 9:51:24 AM 08/18/2023 Horn 400 Wing North Side Annual 9:51:41 AM 08/18/2023 Horn Leadership Bldg Annual 9:50:18 AM 08/18/2023 Horn Library Hall Annual 9:51:27 AM 08/18/2023 Horn Room 209 Outside Annual 9:53:01 AM 08/18/2023 Horn Team Room Annual 9:51:14 AM 08/18/2023 Horn/Strobe Room 209 Annual 9:49:41 AM 08/18/2023 Horn/Strobe Room 211 Annual 9:49:37 AM 08/18/2023 Initiating Pull Station 100 Wing Outside Annual 8:53:07 AM 08/18/2023 Pull Station 200 Wing East Annual 8:51:54 AM 08/18/2023 Pull Station 200 Wing West Annual 8:49:01 AM 08/18/2023 Pull Station 300 Wing Annual 9:21:13 AM 08/18/2023 Pull Station 400 Wing East Annual 9:02:37 AM 08/18/2023 Pull Station 400 Wing West Annual 9:47:01 AM 08/18/2023 Pull Station Leadership Bldg Annual 9:31:20 AM 08/18/2023 Hue&Cry,Inc. Page 7 of 12 Download Date:08/21/2023 Inspection&Testing Device Type Location Service Time Date Passed Pull Station Library Hall East Annual 9:00:03 AM 08/18/2023 Pull Station Library Hall West Annual 9:37:43 AM 08/18/2023 Pull Station Office Hall Annual 9:25:29 AM 08/18/2023 Pull Station Room 209 Annual 8:44:37 AM 08/18/2023 Pull Station Room 211 Annual 8:29:56 AM 08/18/2023 Pull Station Team Room Annual 9:49:11 AM 08/18/2023 Smoke Detector Room 209 Annual 8:44:24 AM 08/18/2023 Smoke Detector Room 209 Annual 8:44:28 AM 08/18/2023 Smoke Detector Room 211 Annual 8:31:12 AM 08/18/2023 Smoke Detector Room 211 Annual 8:44:18 AM 08/18/2023 Device Type Location Service Time Date Failed/Other Indicating 2 Horn 400 Wing West Side Annual 9:52:23 AM 08/18/2023 1 Horn Boys Locker Room Annual 9:50:43 AM 08/18/2023 1 Horn Floral shop Annual 9:52:39 AM 08/18/2023 1 Horn Girls Locker Room Annual 9:53:48 AM 08/18/2023 1 Horn Outside Locker Room North Annual 9:51:09 AM 08/18/2023 1 Horn Wood Shop Annual 9:52:53 AM 08/18/2023 1 Horn portable 603 Annual 9:53:15 AM 08/18/2023 1 Horn/Strobe N/E Portable Annual 9:49:59 AM 08/18/2023 Initiating 1 Pull Station Boys Locker Room Annual 9:33:25 AM 08/18/2023 1 Pull Station Floral shop Annual 9:33:42 AM 08/18/2023 1 Pull Station Girls Locker Room Annual 9:34:00 AM 08/18/2023 1 Pull Station N/E Portable Room 603 Annual 9:34:38 AM 08/18/2023 1 Pull Station Wood Shop Annual 9:34:23 AM 08/18/2023 Hue&Cry,Inc. Page 8 of 12 Download Date:08/21/2023 Inspection&Testing Service Summary Generated by:BuildingReports.com Building: Gridley High School The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity Failed/Other Horn/Strobe Annual 1 Horn Annual 7 Pull Station Annual 5 Total 13 Passed Battery Annual 4 Bell Annual 1 Control Panel Annual 1 Disconnect Annual 2 Horn/Strobe Annual 2 Horn Annual 8 Power Supply Annual 1 Pull Station Annual 13 Smoke Detector Annual 4 Total 36 Grand Total 49 Hue&Cry,Inc. Page 9 of 12 Download Date:08/21/2023 Service Summary Battery & Power Supply Testing Generated by:BuildingReports.com Building: Gridley High School Control Panel: 1 - Fire-Lite MS-10US The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems.Items are grouped by Passed or Failed/Other. Rated Rated Post Type Location Ah Volts Pre Test Test Min Ah Tested Ah Battery Passed Sealed Lead Acid 10th Below Connector Cell 7 12 13.04 4.55 7.8 Room 211 Power Supply Sealed Lead Acid FACP 18 12 12.97 7.80 19 Sealed Lead Acid FACP Left Batt 18 12 12.97 7.80 24 Sealed Lead Acid Room 211 Power Supply 7 12 13.16 4.55 7.8 Hue&Cry,Inc. Page 10 of 12 Download Date:08/21/2023 Battery&Power Supply Testing Inventory & Warranty Report Generated by:BuildingReports.com Building: Gridley High School Control Panel: 1 - Fire-Lite MS-10US The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided.Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Type Catego %of Inventory Quantity Battery Control 8.16% 4 Bell Indicating 2.04% 1 Control Panel Control 2.04% 1 Disconnect Control 4.08% 2 Horn Indicating 30.61% 15 Horn/Strobe Indicating 6.12% 3 Power Supply Control 2.04% 1 Pull Station Initiating 36.73% 18 Smoke Detector Initiating 8.16% 4 Type Qty Model# Description Install Date In Service - 90 Days - 1 Year Ultra Tech Battery 1 PS-1270F1 Sealed Lead Acid 02/21/2023 In Service- 3 Years to 5 Years Power-Sonic Battery 2 PS-12180NB Sealed Lead Acid 04/20/2020 In Service - 5 Years to 10 Years Power-Sonic Battery 1 PS-1270F1 Sealed Lead Acid 10/21/2014 In Service- 10 Years to 15 Years Altronix Power Supply 1 AL3000LXR 07/21/2010 Detection Systems Smoke Detector 4 DS282 Photoelectric 07/21/2010 Fire Lite Pull Station 1 BG-12L0 Single Action 07/21/2010 Fire-Lite Control Panel 1 MS-10US 07/21/2010 Pull Station 1 BG-10 Dual Action 07/21/2010 Pull Station 3 BG-12 Dual Action 07/21/2010 Honeywell Horn 8 SC806A1004 07/21/2010 Pull Station 6 S464A1045 Single Action 07/21/2010 Hue&Cry,Inc. Page 11 of 12 Download Date:08/21/2023 Inventory&Warranty Report Pull Station 3 S46A1045 Single Action 07/21/2010 Modtech Disconnect 1 15amp Breaker 07/21/2010 SimplexGrinnell Horn 3 4040 07/21/2010 Pull Station 1 2099-9101 Single Action 07/21/2010 Pull Station 3 4251-1 125v Single Action 07/21/2010 Square D Disconnect 1 20amp Breaker 07/21/2010 System Sensor Horn 1 H12/24K 07/21/2010 Horn/Strobe 2 P2R 07/21/2010 Unknown Bell 1 12" 07/21/2010 Wheelock Horn 1 31T-115 07/21/2010 Horn 1 34-24 07/21/2010 Horn 1 MT-24R 07/21/2010 Horn/Strobe 1 NS-24MCW 07/21/2010 Hue&Cry,Inc. Page 12 of 12 Download Date:08/21/2023 Inventory&Warranty Report