Loading...
HomeMy WebLinkAboutFAI22-0003 010-051-001 CF FA 8-21-2023_McKinley-Elementary-School Fire Alarm and Life Safety System Inspection Certificate For McKinley Elementary School 1045 Sycamore Street Gridley, CA 95948 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Aug 21, 2023 Building:McKinley Elementary School Company:Hue&Cry,Inc. Contact: Jordan Reeves Contact: Chyna Reed Title: Superintendent Title: Inspector Fire Alarm Testing Report Executive Summary Generated by:BuildingReports.com Building Information Building: McKinley Elementary School Contact: Jordan Reeves Address: 1045 Sycamore Street Phone: 1-530-846-4721 Address: Fax: City/State/ZIP Code: Gridley, CA 95948 Mobile: Country: United States of America Email:jreeves@gusd.org Inspection Performed By Company: Hue&Cry, Inc. Inspector: Chyna Reed Address: 1751 Bruce Drive Phone: 530-356-7007 Address: Fax: City/State/ZIP Code:Anderson, California 96007 Mobile: Country: United States of America Email: c.reed@hueandcry.com System Control Unit Manufacturer: Silent Knight Inspection Date: 08/21/2023 IDC Style: B Model Number: 5820XL Install Date: 01/31/2005 SLC Style:4 Software Version: 9.08 Version Date: 05/11/2007 NAC Style: Y Location: Rear Electrical Room in Electric Box Current Protection: Breaker Disconnect Location: Rear Electrical Room in Electric Box Type: Breaker Hue&Cry,Inc. Page 2 of 13 Download Date:08/22/2023 Executive Summary Inspection Summary Total Items Serviced Passed Failed/Other Category: Qty % Qty % Qty % Qty % Auxiliary 1 1.54% 1 100.00% 1 100.00% 0 0.00% Control 8 12.31% 8 100.00% 8 100.00% 0 0.00% Indicating 17 26.15% 17 100.00% 17 100.00% 0 0.00% Initiating 38 58.46% 38 100.00% 38 100.00% 0 0.00% Monitor 1 1.54% 1 100.00% 1 100.00% 0 0.00% Totals 65 100% 65 100.00% 65 100.00% 0 0.00% Certification Company: Hue&Cry, Inc. Building: McKinley Elementary School Inspector: Chyna Reed Contact: Jordan Reeves (_,-' 1 -AU-74-- Signed: Aug 21, 2023 Signed:Aug 21, 2023 Hue&Cry,Inc. Page 3 of 13 Download Date:08/22/2023 Executive Summary Notes & Recommendations Generated by:BuildingReports.com Building: McKinley Elementary School The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection.Notes are grouped by Category. General Note Battery is room 3 power supply replaced&approved by Adrianna Hue&Cry,Inc. Page 4 of 13 Download Date:08/22/2023 Notes&Recommendations Inspection & Testing Generated by:BuildingReports.com Building: McKinley Elementary School Control Panel: 1 - Silent Knight 5820XL The Inspection& Testing section lists all of the items inspected in your building.Items are grouped by Passed or Failed/Other.Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. Device Type Location Service Time Date Passed Auxiliary Lighting Control Room 12 Above Tile North End Annual 1:27:49 PM 08/21/2023 Control Annunciator Main Hall East by Custodian Room Annual 1:09:53 PM 08/21/2023 Battery FACP Annual 11:57:19 AM 08/21/2023 Battery FACP Annual 11:57:44 AM 08/21/2023 Battery Room 3 Replaced 1:18:45 PM 08/21/2023 Battery Room 3 Replaced 1:18:51 PM 08/21/2023 Control Panel Rear Electrical Room in Electric Box Annual 11:58:40 AM 08/21/2023 Disconnect Rear Electrical Room in Electric Box Annual 11:59:02 AM 08/21/2023 Voice Evacuation Room 3 Annual 12:10:01 PM 08/21/2023 Indicating Horn East Playground Annual 1:10:25 PM 08/21/2023 Horn South Outside Electrical Room Annual 1:10:30 PM 08/21/2023 Horn West Playground Annual 1:10:21 PM 08/21/2023 Horn Room 2 Annual 1:10:18 PM 08/21/2023 Horn/Strobe Main Hall East Annual 1:06:41 PM 08/21/2023 Horn/Strobe Main Hall West Annual 1:06:47 PM 08/21/2023 Horn/Strobe Room 12 Annual 1:07:02 PM 08/21/2023 Horn/Strobe Room 14 Annual 1:06:58 PM 08/21/2023 Horn/Strobe Room 15 Annual 1:06:54 PM 08/21/2023 Horn/Strobe Room 16 ELO2 4.7k resistor 25.7v Annual 1:06:50 PM 08/21/2023 Speaker/Strobe Restroom 1 Annual 12:32:34 PM 08/21/2023 Speaker/Strobe Room 2 Annual 12:50:37 PM 08/21/2023 Speaker/Strobe Room 3 Annual 12:50:44 PM 08/21/2023 Speaker/Strobe Room1 Annual 12:50:41 PM 08/21/2023 Speaker/Strobe Women Restroom Annual 12:28:14 PM 08/21/2023 Speaker/Strobe Work Room Annual 12:50:34 PM 08/21/2023 Strobe Room 3 Bathroom Annual 12:50:48 PM 08/21/2023 Initiating Hue&Cry,Inc. Page 5 of 13 Download Date:08/22/2023 Inspection&Testing Device Type Location Service Time Date Passed Heat Detector Portable restroom above ceiling Annual 1:07:57 PM 08/21/2023 Heat Detector Room 1 Above Tile Annual 1:07:07 PM 08/21/2023 Heat Detector Room 12 Above Tile South End Annual 1:09:17 PM 08/21/2023 Heat Detector Room 14 Above Tile North End Annual 1:09:40 PM 08/21/2023 Heat Detector Room 14 Above Tile South End Annual 1:09:20 PM 08/21/2023 Heat Detector Room 15 Above Tile North End Annual 1:09:36 PM 08/21/2023 Heat Detector Room 15 Above Tile South End Annual 1:09:23 PM 08/21/2023 Heat Detector Room 16 Above Tile North End Annual 1:09:32 PM 08/21/2023 Heat Detector Room 16 Above Tile South End Annual 1:09:29 PM 08/21/2023 Heat Detector Room 2 Above Tile Annual 1:07:11 PM 08/21/2023 Heat Detector Room 3 Above Tile Annual 1:07:14 PM 08/21/2023 Heat Detector Work Room @rooml Annual 1:08:00 PM 08/21/2023 Pull Station Main Hall East by Room 8 Annual 1:26:50 PM 08/21/2023 Pull Station Main Hall West by Room 6 Annual 1:26:47 PM 08/21/2023 Pull Station Room 1 Annual 1:05:52 PM 08/21/2023 Pull Station Room 2 Annual 1:05:57 PM 08/21/2023 Pull Station Room 3 Annual 1:05:55 PM 08/21/2023 Pull Station West Playground Annual 12:22:30 PM 08/21/2023 Pull Station Work Room @rooml Annual 1:06:01 PM 08/21/2023 Smoke Detector Restroom Annual 12:31:45 PM 08/21/2023 Smoke Detector Room 1 Annual 12:47:37 PM 08/21/2023 Smoke Detector Room 1 Annual 12:47:40 PM 08/21/2023 Smoke Detector Room 12 West Annual 1:05:43 PM 08/21/2023 Smoke Detector Room 14 East Annual 1:02:45 PM 08/21/2023 Smoke Detector Room 14 West Annual 1:02:41 PM 08/21/2023 Smoke Detector Room 15 East Annual 12:57:45 PM 08/21/2023 Smoke Detector Room 15 West Annual 12:57:48 PM 08/21/2023 Smoke Detector Room 16 East Annual 12:57:41 PM 08/21/2023 Smoke Detector Room 16 West Annual 12:57:38 PM 08/21/2023 Smoke Detector Room 2 Annual 12:47:43 PM 08/21/2023 Smoke Detector Room 2 Annual 12:47:46 PM 08/21/2023 Smoke Detector Room 3 Annual 12:47:51 PM 08/21/2023 Smoke Detector Room 3 Annual 12:47:53 PM 08/21/2023 Smoke Detector Women Restroom Annual 12:28:03 PM 08/21/2023 Smoke Detector Work Room @rooml Annual 12:50:26 PM 08/21/2023 Smoke Detector Work Room @rooml Annual 12:50:29 PM 08/21/2023 Smoke Detector Room 12 East Annual 1:05:46 PM 08/21/2023 Hue&Cry,Inc. Page 6 of 13 Download Date:08/22/2023 Inspection&Testing Device Type Location Service Time Date Passed Smoke Detector Room 3 restroom Annual 12:34:47 PM 08/21/2023 Monitor Monitor Device Room 3 Annual 12:10:21 PM 08/21/2023 Hue&Cry,Inc. Page 7 of 13 Download Date:08/22/2023 Inspection&Testing Service Summary Generated by:BuildingReports.com Building: McKinley Elementary School The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity Passed Annunciator Annual 1 Battery Annual 2 Battery Replaced 2 Control Panel Annual 1 Disconnect Annual 1 Heat Detector Annual 12 Horn/Strobe Annual 6 Horn Annual 4 Lighting Control Annual 1 Monitor Device Annual 1 Pull Station Annual 7 Smoke Detector Annual 19 Speaker/Strobe Annual 6 Strobe Annual 1 Voice Evacuation Annual 1 Total 65 Grand Total 65 Hue&Cry,Inc. Page 8 of 13 Download Date:08/22/2023 Service Summary Auxiliary Functions Testing Generated by:BuildingReports.com Building: McKinley Elementary School Control Panel: 1 - Silent Knight 5820XL The Auxiliary Functions Testing section lists each of the ancillary items, systems, and emergency equipment that are controlled by the system control unit.Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. Type Location Comment ScaniD Simulated Passed Lighting Control Room 12 Above Tile North End Passed 11531210 ❑ Smoke Detector Smoke Compartment Restroom Passed 51368394 Smoke Compartment Room 1 Passed 46435456 Smoke Compartment Room 1 Passed 46435455 Smoke Compartment Room 12 West Passed 11531212 Smoke Compartment Room 14 East Passed 11531215 Smoke Compartment Room 14 West Passed 11531217 Smoke Compartment Room 15 East Passed 11531219 Smoke Compartment Room 15 West Passed 11531218 Smoke Compartment Room 16 East Passed 11531224 Smoke Compartment Room 16 West Passed 11531225 Smoke Compartment Room 2 Passed 46435453 Smoke Compartment Room 2 Passed 46435452 Smoke Compartment Women Restroom Passed 51368393 Smoke Compartment Work Room @rooml Passed 51368403 Smoke Compartment Work Room @rooml Passed 51368402 Smoke Compartment Room 12 East Passed 11531211 Smoke Compartment Room 3 restroom Passed 51368401 Hue&Cry,Inc. Page 9 of 13 Download Date:08/22/2023 Auxiliary Functions Testing Battery & Power Supply Testing Generated by:BuildingReports.com Building: McKinley Elementary School Control Panel: 1 - Silent Knight 582OXL The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems.Items are grouped by Passed or Failed/Other. Rated Rated Post Type Location Ah Volts Pre Test Test Min Ah Tested Ah Battery Passed Sealed Lead Acid FACP 7 12 12.66 4.55 11 Sealed Lead Acid FACP 7.0 12 12.66 4.55 11 Sealed Lead Acid Room 3 8 12 12.66 4.55 4.6 Sealed Lead Acid Room 3 8 12 12.62 4.55 4.2 Hue&Cry,Inc. Page 10 of 13 Download Date:08/22/2023 Battery&Power Supply Testing Inventory & Warranty Report Generated by:BuildingReports.com Building: McKinley Elementary School Control Panel: 1 - Silent Knight 5820XL The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided.Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Type Catego %of Inventory Quantity Annunciator Control 1.54% 1 Battery Control 6.15% 4 Control Panel Control 1.54% 1 Disconnect Control 1.54% 1 Heat Detector Initiating 18.46% 12 Horn Indicating 6.15% 4 Horn/Strobe Indicating 9.23% 6 Lighting Control Auxiliary 1.54% 1 Monitor Device Monitor 1.54% 1 Pull Station Initiating 10.77% 7 Smoke Detector Initiating 29.23% 19 Speaker/Strobe Indicating 9.23% 6 Strobe Indicating 1.54% 1 Voice Evacuation Control 1.54% 1 Type Qty Model# Description Install Date In Service - 2 Years to 3 Years Duracell Battery 2 12-8F2 Sealed Lead Acid 01/04/2021 In Service - 3 Years to 5 Years Power-Sonic Battery 2 PS 1270-F1 Sealed Lead Acid 11/19/2018 In Service - 5 Years to 10 Years Fire-Lite Pull Station 1 BG-12LO/SD500- Dual Action 11/13/2014 MIM In Service- 15 Years to 25 Years Cutler/Hammer Disconnect 1 20amp Breaker 01/31/2005 Silent Knight Annunciator 1 5860 01/31/2005 Control Panel 1 5820XL 01/31/2005 Monitor Device 1 SD500-ARM Relay 01/31/2005 Pull Station 6 SD500-PS Single Action 01/31/2005 Smoke Detector 8 SD505-APS Photoelectric 01/31/2005 Hue&Cry,Inc. Page 11 of 13 Download Date:08/22/2023 Inventory&Warranty Report Smoke Detector 2 SD505-PHOTO 01/31/2005 Smoke Detector 9 SD505-PHOTO Photoelectric 01/31/2005 System Sensor Heat Detector 12 5602 Combination 01/31/2005 Lighting Control 1 5602 01/31/2005 Wheelock Horn 1 01/31/2005 Horn 3 AH-24WP 01/31/2005 Horn/Strobe 6 AS24-MCW 01/31/2005 Speaker/Strobe 6 LSPSTR 01/31/2005 Strobe 1 LSPSTR 01/31/2005 Voice Evacuation 1 SP40S 01/31/2005 Hue&Cry,Inc. Page 12 of 13 Download Date:08/22/2023 Inventory&Warranty Report Zone Address Report Generated by:BuildingReports.com Building: McKinley Elementary School Control Panel: 1 - Silent Knight 5820XL The Zone Address Report lists all of the devices and items that have an individual address, or are grouped together under a common zone. The device type, location, and description are included for your reference. Address Device Type Location Type ScaniD Zone/Circuit: 01- 1 Heat Detector Room 12 Above Tile South End Combination 16404062 Zone/Circuit: 02- 1 Lighting Control Room 12 Above Tile North End 11531210 1 Heat Detector Room 14 Above Tile North End Combination 11531214 2 Heat Detector Portable restroom above ceiling Combination 56777923 2 Heat Detector Room 1 Above Tile Combination 56777930 2 Heat Detector Room 14 Above Tile South End Combination 16404061 2 Heat Detector Room 2 Above Tile Combination 56777929 2 Heat Detector Room 3 Above Tile Combination 56777928 2 Heat Detector Work Room @rooml Combination 56777921 Zone/Circuit: 03- 1 Heat Detector Room 15 Above Tile South End Combination 16404060 2 Heat Detector Room 15 Above Tile North End Combination 11531221 3 Heat Detector Room 16 Above Tile North End Combination 11531222 4 Heat Detector Room 16 Above Tile South End Combination 16404059 Zone/Circuit: 05- Smoke Detector Room 12 West Photoelectric 11531212 Zone/Circuit: 06- Smoke Detector Work Room @rooml Photoelectric 51368402 Smoke Detector Work Room @rooml Photoelectric 51368403 Smoke Detector Room 12 East Photoelectric 11531211 Smoke Detector Room 3 restroom Photoelectric 51368401 Zone/Circuit: M33 P015 Pull Station West Playground Dual Action 32021985 07 Smoke Detector Room 14 West Photoelectric 11531217 08 Smoke Detector Room 14 East Photoelectric 11531215 09 Smoke Detector Room 15 East Photoelectric 11531219 10 Smoke Detector Room 15 West Photoelectric 11531218 11 Smoke Detector Room 16 West Photoelectric 11531225 12 Smoke Detector Room 16 East Photoelectric 11531224 Hue&Cry,Inc. Page 13 of 13 Download Date:08/22/2023 Zone Address Report