HomeMy WebLinkAboutFAI23-0002 040-310-093 Truroots29 Fire Alarm System Drawing 6-19-23 Equipment Locations Point to Point Diagram izu Truroots LLC z z co 29 SpeedwayAvenue q) NI Cell Communicator o ; � � S,� o Chico, CA 95928 I \ located next to FACP �aQ (2nd Floor) ,� ,� � � M ® ®®•® Occupancy: F-2, S-2, B ° # of Levels: Office: 2, Warehouse: 1 Q I �' o ® O ; AES a e Fully Sprinklered U 1� 770 7P-88-ULP-M OO OO Enclosure O for WW �j I-I i I ® Transformer Adopted Codes: q .V " c O Class II 2022 CFC _ Transformer 16 - 7794 .5 VAC 40U4 Guidelines: NFPA 72 (2022) U 1011111111 I 111 I 111 _ 2®®e ®® 7794 ° NFPA 70 (2020) CZ • • • COO ••,A••' a" m a IW 0 NO NC C N( NC C E T G V+ + Ilk p \-----------------------------------------------------------------------------------" . N Battery N 12v 12AH M 1. /................. HISTORY: co i This project has an existing Bosch D7412GV4 Fire Control Panel. Q) 1 'S0N, ,' \V✓ I I Existing Fire Alarm System: Manual and Automatic,Sprinkler c H i 11 Supervisory System z (1),. SCOPE: J U Q \ \ Eagle will install an AES mesh network radio for U) ■ communication on an existing Fire Alarm Control .,� Unit. No other additions. 0 �, O ,! I / BOSCH yNo changes will be made to the existing fire alarm system's battery calculations as the AES Communicator 111 " is powered independently and has its own back-up L tilo \ H � 1 �ii o D7412GV4 + �— �� ( ) O battery. The AES simulates dial tone / voltage required J �° USID 2DATAAO for the FACU. Specifically, Eagle will install a �� ooviu- ��.s,� AC DATA B 0 7707p-88-ULP-M AES Radio and connect it to the _ al AC (-) O Bosch D7412GV4 UL FACU via phone lines between (Ni NEM EXISTING '‘111%111 II fig7. VI-L 1� �� �oi� ��.:� Aux (+) the FACU onboard DACT and the AES IntelliPro for Jj III ° Bat (-) FA C U (+) 0 signal reporting. The FACP is addressable and will Lt ��� ii Bat (+) sin DATA A 0 report via SIA, all Zones by Point to the Central Station. �- I - ��� Relay A DATA B 0 0 N , The communicator transformer power wire shall be running w �- M+I Relay B (-) 0 W 3 ��.:� Relay C OUT 1 0 through the required conduit from the communicator O 0 ■ • i+I COM IN 1 O enclosure to the manufacturer supplied transformer cover. m �` _0', GRD J OUT 2 0 The transformer cover will encapsulate an unswitched \\ D928 IN 2 O power outlet. All wire and grounding shall be installed per o �, , TI- n n n n + 0 manufacturers specs and shall be tested for integrity & o O O O O ( ) p 9 Y 1— oo (S tv w 4, rn COM 0 supervision between the AES and FACU. All wire connections 2 �- C� ° c Y between FACU and AES shall be in conduit. _ co..-----------------------a----------------r \II 000000 000000 .1t # `;, T 1- \ / H � L00 "C _, W The AES communicator is an RF mesh network radio that meets a .� g Ithe requirements for One Way Private Radio in NFPA 72, 0 o .i o _ } I El 2022-26.6.5.2 and listed NFPA 72 2022 — Table A 26.6.1 V cz Q) r , /-\ a e f'' -' 26.6.5.2- Monitor the quality of signal and indicate at the a 0 .Q tz w supervising station if it falls below the minimum. Test from every Q 1 o transmitter every 24 hours. 26.6.5.2.1(B), Shall have minimum two independent RF paths Speedway A v e n L e simultaneously employed (NetCom 5). N Area Map One Line Diagram NETCOM <5 Standby Battery Calculation * co 1 � rn co ca U •M Q) o Communicator o U ' 0 AES N 7707P-88-ULP-M Transformer 16vac 40VA 7794 Battery 12v 12AH KEYPAD D 1255 PHI PH2 3 D928 Smoke Detector (4) Horn/Strobe ( ) Manual Station (2) Strobe (2) EXISTING Waterflow (5) Curtis F. Toon FACP Valve Tamper (7) NICET Level IV Fire Alarm Systems Certification# 107227 (Conventional) Expires:Feb. 1 2024 NAC POWER Bosch EXTENDER D7412GV4 Rev Date D9142F AES 7707P-88-ULP-M Communicator 1D192C1 Primary Power - 16VAC 40VA Class II Transformer SHEET NO *Backup Power - 12AH Battery Battery *Battery Calculation: 10.3AH (12AH provided) I 110VAC 2ea, 12v(AH as calculated)