HomeMy WebLinkAboutFAI23-0002 040-310-093 Truroots29 Fire Alarm System Drawing 6-19-23 (2) Equipment Locations Point to Point Diagram11) TrurootsLLCZ Q op 29 Speedway Avenue (1) cy Cell Communicator o °;� .�o o di S, : o Chico, CA 95928 cz 1\ \ located next to FACPweat (2nd Floor) 3�5 i �WA� > > • •••• Occu anc : F-2 S-2, B .3 p YCZ 5 �i i2 # of Levels: Office: 2 Warehouse: 1 Q 1 \ 0 0 AES & ° 1p FullySprinklered liti _— 770 7P-88-ULP-M Q) o 00 Enclosure ] for I wen' • .= Q TransformerlI Adopted Codes: a) ■ I I - W � � ' i = 2022 CFC Class II 9 Transformer - Q 7794 16.5V4C40UA Guidelines: NFPA 72 (2022) U T R T, II A11111111 o i�i�i�i�i��i 7794 o NFPA 70 (2020) \ _________— : . . . NO NC C NQ NC C IoorEr ':G V- Aliiir F!! 110 1 N -\ , . 1 1 L. N/r , . .. Battery M N 12v 12AHszZ HISTORY: co This project has an existing Bosch D7412GV4 Fire Control Panel. Q) S W H 11 Existing Fire Alarm System: Manual and Automatic,Sprinkler Supervisory System CD w U SCOPE: J Q ��� Eagle will install an AES mesh network radio for CO (/)cI v. communication on an existing Fire Alarm Control Z Unit. No other additions. 0 t B // No changes will be made to the existing fire alarm O\ii ________---- / OSCI 1 \ system's battery calculations as the AES Communicator is powered independently and has its own back-up u, iz �✓ H 1 ' • • _ o D7412GV4 (+) O battery. The AES simulates dial tone /voltage required 0 DATA A O DE ® SI D 2 for the FACU. Specifically, Eagle will install a LL o o cc — I o , AC DATA 0 7707p-88-ULP-M AES Radio and connect it to the cc N co E AC EXISTING Bosch D7412GV4 UL FACU via phone Ines between _p •Lam' Aux (+) the FACU onboard DACT and the AES IntelliPro for - _,�� o ° I� �• ° • _ Bat (-) F'4C U (+) ° /, signal reporting. The FACP is addressable and will — (J _, I Bat (+) SI D DATA A O report via SIA, all Zones by Point to the Central Station. I- O I Relay A DATA B The communicator transformer power wire shall be running w 1-- 1 �� W H , 3 Relay e (-) Relay C OUT 1 O through the required conduit from the communicator O j`/ LCOM IN 1 O enclosure to the manufacturer supplied transformer cover. 0 m � ] 70:1 GRD J OUT 2 O The transformer cover will encapsulate an unswitched �\ D928 power outlet. All wire and groundingshall be installedper o 0 A— / IN 2 O ,p .2 . I O O O p (+) 0 manufacturer specs and shall be tested for integrity & ° ti w -N of rn N co COM O supervision between the AES and FACU. All wire connections Z q2r IN ° Q ° i, between FACU and AES shall be in conduit. _ T8 7 a J L OO1oO1O1O10oo010101 � _ � � `� 3 i —T, WH The AES communicator is an RF mesh network radio that meets 2 -° - 2 If the requirements for One Way Private Radio in NFPA 72, O (13 z 'i -C a) n I I 2022-26.6.5.2 and listed NFPA 72 2022- Table A 26.6.1 V a (13 co r ��. e 26.6.5.2- Monitor the quality of signal and indicate at the ° Q. .Q _ -ac) ° supervising station if it falls below the minimum. Test from every Q transmitter every 24 hours. -` 26.6.5.2.1(8), Shall have minimum two independent RF paths S D e e d w a y Ave L, e simultaneously employed (NetCom 5). N Area Map One Line Diagram NETCOM <5 Standby Battery Calculation co in 1 co � rn 1 QQ CZ M Q) ° o Communicator o U "' 0 AES N 7707P-88-ULP-M — Transformer 16vac 40VA 7794 1 i — Battery I12v 12AH KEYPAD 1D1255 1 PH 1 PH2 I D928 Smoke Detector (4) Horn/Strobe (3) Manual Station (2) Strobe (2) EXISTING Waterflow (5) Curtis F. Toon FACP Valve Tamper (7) NICET Level IV Fire Alarm Systems Certification# 107227 I (Conventional) Expires:Feb. 1 2024 NAC POWER Bosch EXTENDER D7412GV4 Rev Date D9142F AES 7707P-88-ULP-M Communicator I 1D 192C 1 Primary Power - 16VAC 40VA Class II Transformer SHEET NO I *Backup Power - 12AH Battery Battery *Battery Calculation: 10.3AH (12AH provided) I 110VAC 2ea, 12v(AH as calculated)