Loading...
HomeMy WebLinkAboutFAI23-0002 040-310-093 ROC 37 SPEEDWAY 2023 Form Completion Date: 06-21-2023  Supplemental Pages Attached: SHEET A   1. PROPERTY INFORMATION Name of property: TRUROOTS  Address: 37 SPEEDWAY AVE CHICO CA 95928  Description of property:        Name of property representative:        Address:        Phone:       Fax:       E-mail:        2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: EAGLE SECURITY  Address: 2700 HEGAN LANE CHICO CA 95928  Phone: 800-841-0830 Fax:       E-mail:        Service organization: EAGLE SECURITY  Address: 2700 HEGAN LANE CHICO CA 95928  Phone: 800-841-0830 Fax:       E-mail:        Testing organization: EAGLE SECURITY  Address: 2700 HEGAN LANE CHICO CA 95928  Phone: 800-841-0830 Fax:       E-mail:        Effective date for test and inspection contract:        Monitoring organization: VYANET OPERATING GROUP  Address: 410 SW COLUMBIA BEND OR 97702  Phone: 541-241-1800 Fax:       E-mail:        Account number: 317/318-C009 Phone line 1: AES Phone line 2: AES  Means of transmission: AES RADIO  Entity to which alarms are retransmitted:       Phone:        3. DOCUMENTATION On-site location of the required record documents and site-specific software:        4. DESCRIPTION OF SYSTEM OR SERVICE This is a:  New system  Modification to existing system Permit number: NO PERMIT  NFPA 72 edition: 2022    4.1 Control Unit  Manufacturer: BOSCH Model number: FPA-1000    4.2 Software and Firmware  Firmware revision number: 2.01    4.3 Alarm Verification  This system does not incorporate alarm verification.  Number of devices subject to alarm verification:        Alarm verification set for       seconds   5. SYSTEM POWER 5.1 Control Unit  5.1.1 Primary Power  Input voltage of control panel: 120  Control panel amps: 50  Overcurrent protection: Type: CIRCUIT BREAKER  Amps: 20  Branch circuit disconnecting means location: IT ROOM  Number: D1F2B    5.1.2 Secondary Power  Type of secondary power: SEALSE LEAD ACID BATTERY  Location, if remote from the plant:        Calculated capacity of secondary power to drive the system:  In standby mode (hours):        In alarm mode (minutes):          5.2 Control Unit   This system does not have power extender panels   Power extender panels are listed on supplementary sheet A  6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level  Signaling Line             B        Device Power             B        Initiating Device             B        Notification Appliance             B        Other (specify):                                     7. REMOTE ANNUNCIATORS Type Location  BOSCH FMR 1000 RECEPTION AREA  BOSCH FMR 1000 BREAK ROOM  8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology  Manual Pull Stations 4 ADDRESSABLE ALARM        Smoke Detectors 28 ADDRESSABLE ALARM        Duct Smoke Detectors 6 ADDRESSABLE ALARM        Heat Detectors 133 ADDRESSABLE ALARM        Gas Detectors 0                    Waterflow Switches 2 ADDRESSABLE ALARM        Tamper Switches 3 ADDRESABLE SUPERVISORY         9. NOTIFICATION APPLIANCES Type Quantity Description  Audible 20 HORN  Visible 3 STROBE  Combination Audible and Visible 2 HORN STROBE  10. SYSTEM CONTROL FUNCTIONS Type Quantity  Hold-Open Door Releasing Devices        HVAC Shutdown        Fire/Smoke Dampers        Door Unlocking        Elevator Recall        Elevator Shunt Trip                                  11. INTERCONNECTED SYSTEMS  This system does not have interconnected systems.   Interconnected systems are listed on supplementary sheet       .  12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor  This system as specified herein has been installed according to all NFPA standards cited herein.  Signed:       Printed name: BRAD REID Date: 06/21/2023  Organization: VYANET Title: TECHNICIAN Phone: 909-261-5715    12.2 System Operational Test  This system as specified herein has tested according to all NFPA standards cited herein.  Signed:       Printed name: BRAD REID Date: 06/21/2023  Organization: VYANET Title: TECHNICIAN Phone: 909-261-5715    12.3 Acceptance Test  Date and time of acceptance test:        Installing contractor representative:        Testing contractor representative:        Property representative:        AHJ representative: